메뉴 건너뛰기




Volumn 51, Issue , 2015, Pages 850-853

3D quantitative evaluation system for integral photography based 3D autostereoscopic medical display

Author keywords

3D medical display; 3D quantitative evaluation; Integral Photography

Indexed keywords

BIOMEDICAL ENGINEERING; DISPLAY DEVICES; HARDWARE; IMAGE ACQUISITION; MEDICAL IMAGING; MEDICINE; PHOTOGRAPHY; STEREO IMAGE PROCESSING; THREE DIMENSIONAL COMPUTER GRAPHICS;

EID: 84944311416     PISSN: 16800737     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1007/978-3-319-19387-8_208     Document Type: Conference Paper
Times cited : (4)

References (6)
  • 1
    • 0001652127 scopus 로고    scopus 로고
    • Analysis of resolution limitation of integral photography
    • H. Hoshino et al, “Analysis of resolution limitation of integral photography,” JOSA A, vol. 15, pp. 2059-2065, 1998.
    • (1998) JOSA A , vol.15 , pp. 2059-2065
    • Hoshino, H.1
  • 2
    • 34247230256 scopus 로고    scopus 로고
    • Improved Viewing Resolution of Integral Videography by use of Rotated Prism Sheets
    • April
    • H. Liao et al, “Improved Viewing Resolution of Integral Videography by use of Rotated Prism Sheets,” Optics Express, Vol. 15, No. 8, pp. 4814-4822, April 2007.
    • (2007) Optics Express , vol.15 , Issue.8 , pp. 4814-4822
    • Liao, H.1
  • 3
    • 20344395357 scopus 로고    scopus 로고
    • High Quality Autostereoscopic Surgical Display of Integral Videography Imaging; Medical Image Computing and Computer-Assisted Intervention
    • Lecture Notes in Computer Science, LNCS, Saint- Malo, France, September
    • H. Liao, et al, “High Quality Autostereoscopic Surgical Display of Integral Videography Imaging; Medical Image Computing and Computer-Assisted Intervention,” MICCAI 2004, Lecture Notes in Computer Science, LNCS 3217, pp. 462-469, Saint- Malo, France, September 2004.
    • (2004) MICCAI 2004 , vol.3217 , pp. 462-469
    • Liao, H.1
  • 4
    • 77952554970 scopus 로고    scopus 로고
    • 3-D augmented reality for MRI-guided surgery using integral videography autostereoscopic image overlay. Biomedical Engineering
    • H. Liao, et al. “3-D augmented reality for MRI-guided surgery using integral videography autostereoscopic image overlay. Biomedical Engineering”, IEEE Transactions on 57.6, 1476-1486. 2010.
    • (2010) IEEE Transactions on 57.6 , pp. 1476-1486
    • Liao, H.1
  • 5
    • 79960357065 scopus 로고    scopus 로고
    • Variable Reference Phase in Diffractive Antennas: Review, Applications, New Results
    • Apr
    • G. W. Webb et al, “Variable Reference Phase in Diffractive Antennas: Review, Applications, New Results,” IEEE Antennas and Propagation Magazine, vol. 53, pp. 77-94, Apr 2011.
    • (2011) IEEE Antennas and Propagation Magazine , vol.53 , pp. 77-94
    • Webb, G.W.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.