메뉴 건너뛰기




Volumn 223, Issue , 2016, Pages 226-233

Ion transfer stripping voltammetry for the detection of nanomolar levels of fluoxetine, citalopram, and sertraline in tap and river water samples

Author keywords

Citalopram; Double polymer modified pencil lead electrode; Fluoxetine; Ion selective electrodes (ISEs); Ion transfer stripping voltammetry (ITSV); Lipophilicity of drugs; Selective serotonin reuptake inhibitors (SSRIs); Sertraline

Indexed keywords

CHEMICAL DETECTION; COATED WIRE ELECTRODES; ELECTRODES; GRAPHITE; IONS; PLASTIC COATINGS; POLYVINYL CHLORIDES; POTABLE WATER; RIVERS; VOLTAMMETRY; WATER; WATER RESOURCES;

EID: 84944104850     PISSN: 09254005     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.snb.2015.09.048     Document Type: Article
Times cited : (52)

References (46)
  • 1
    • 77952973979 scopus 로고    scopus 로고
    • Principles of applications of polarography and voltammetry in the analysis of drugs
    • P. Zuman Principles of applications of polarography and voltammetry in the analysis of drugs FABAD J. Pharm. Sci. 31 2006 97 115
    • (2006) FABAD J. Pharm. Sci. , vol.31 , pp. 97-115
    • Zuman, P.1
  • 2
    • 84914106854 scopus 로고    scopus 로고
    • An electrochemical sensor based on graphene/polyaniline/polystyrene nanoporous fibers modified electrode for simultaneous determination of lead and cadmium
    • N. Promphet, P. Rattanarat, R. Rangkupan, O. Chailapakul, and N. Rodthongkum An electrochemical sensor based on graphene/polyaniline/polystyrene nanoporous fibers modified electrode for simultaneous determination of lead and cadmium Sens. Actuators B: Chem. 207 2015 526 534
    • (2015) Sens. Actuators B: Chem. , vol.207 , pp. 526-534
    • Promphet, N.1    Rattanarat, P.2    Rangkupan, R.3    Chailapakul, O.4    Rodthongkum, N.5
  • 3
    • 84947649756 scopus 로고    scopus 로고
    • An electrochemical analyzer for in situ flow determination of Pb(II) and Cd(II) in lake water with on-line data transmission and a global positioning system
    • V.B. dos Santos, E. Luiz Fava, N.S. Miranda Curi, R. Censi Faria, T.B. Guerreiro, and O. Fatibello-Filho An electrochemical analyzer for in situ flow determination of Pb(II) and Cd(II) in lake water with on-line data transmission and a global positioning system Anal. Methods 2015 10.1039/C5AY00012B
    • (2015) Anal. Methods
    • Dos Santos, V.B.1    Luiz Fava, E.2    Miranda Curi, N.S.3    Censi Faria, R.4    Guerreiro, T.B.5    Fatibello-Filho, O.6
  • 5
    • 84896508187 scopus 로고    scopus 로고
    • 2+ in different real samples based on immobilization of novel unsymmetrical tetradentate Schiff base within PVC membrane
    • 2+ in different real samples based on immobilization of novel unsymmetrical tetradentate Schiff base within PVC membrane Sens. Actuators B: Chem. 197 2014 155 163
    • (2014) Sens. Actuators B: Chem. , vol.197 , pp. 155-163
    • Abdel Aziza, A.A.1    Sedab, S.H.2
  • 6
    • 84903179922 scopus 로고    scopus 로고
    • A novel electrochemical noise sensor applied to detect food safety
    • D.H. Xia, H.H. Wang, K. Wang, C.W. Fu, and J.H. Wang A novel electrochemical noise sensor applied to detect food safety Russ. J. Electrochem. 50 2014 599 602
    • (2014) Russ. J. Electrochem. , vol.50 , pp. 599-602
    • Xia, D.H.1    Wang, H.H.2    Wang, K.3    Fu, C.W.4    Wang, J.H.5
  • 7
    • 84894742523 scopus 로고    scopus 로고
    • Fabrication of magneto-controlled moveable architecture to develop reusable electrochemical biosensors
    • X. Zhu, C. Feng, Z. Ye, Y. Chen, and G. Li Fabrication of magneto-controlled moveable architecture to develop reusable electrochemical biosensors Sci. Rep. 4 2014 4169
    • (2014) Sci. Rep. , vol.4 , pp. 4169
    • Zhu, X.1    Feng, C.2    Ye, Z.3    Chen, Y.4    Li, G.5
  • 8
    • 33750446703 scopus 로고    scopus 로고
    • Platinum electrode coated with a bentonite-carbon composite as an environmental sensor for detection of lead
    • A. Abbaspour, and A. Izadyar Platinum electrode coated with a bentonite-carbon composite as an environmental sensor for detection of lead Anal. Bioanal. Chem. 386 2006 1559 1565
    • (2006) Anal. Bioanal. Chem. , vol.386 , pp. 1559-1565
    • Abbaspour, A.1    Izadyar, A.2
  • 10
    • 84866380366 scopus 로고    scopus 로고
    • Stripping voltammetry of nanomolar potassium and ammonium ions using a valinomycin-doped double-polymer electrode
    • B. Kabagambe, A. Izadyar, and S. Amemiya Stripping voltammetry of nanomolar potassium and ammonium ions using a valinomycin-doped double-polymer electrode Anal. Chem. 84 2012 7979 7986
    • (2012) Anal. Chem. , vol.84 , pp. 7979-7986
    • Kabagambe, B.1    Izadyar, A.2    Amemiya, S.3
  • 11
    • 84894243046 scopus 로고    scopus 로고
    • Ion permeability of the nuclear pore complex and ion-induced macromolecular permeation as studied by scanning electrochemical and fluorescence microscopy
    • J. Kim, A. Izadyar, M. Shen, R. Ishimatsu, and S. Amemiya Ion permeability of the nuclear pore complex and ion-induced macromolecular permeation as studied by scanning electrochemical and fluorescence microscopy Anal. Chem. 86 2014 2090 2098
    • (2014) Anal. Chem. , vol.86 , pp. 2090-2098
    • Kim, J.1    Izadyar, A.2    Shen, M.3    Ishimatsu, R.4    Amemiya, S.5
  • 12
    • 84888287000 scopus 로고    scopus 로고
    • Electrochemical sensing and imaging based on ion transfer at liquid/liquid interfaces
    • S. Amemiya, J. Kim, A. Izadyar, B. Kabagambe, M. Shen, and R. Ishimatsu Electrochemical sensing and imaging based on ion transfer at liquid/liquid interfaces Electrochim. Acta 110 2013 836 845
    • (2013) Electrochim. Acta , vol.110 , pp. 836-845
    • Amemiya, S.1    Kim, J.2    Izadyar, A.3    Kabagambe, B.4    Shen, M.5    Ishimatsu, R.6
  • 13
    • 84873664721 scopus 로고    scopus 로고
    • Nanoscale mechanism of molecular transport through the nuclear pore complex as studied by scanning electrochemical microscopy
    • J. Kim, A. Izadyar, N. Nioradze, and S. Amemiya Nanoscale mechanism of molecular transport through the nuclear pore complex as studied by scanning electrochemical microscopy J. Am. Chem. Soc. 135 2013 2321 2329
    • (2013) J. Am. Chem. Soc. , vol.135 , pp. 2321-2329
    • Kim, J.1    Izadyar, A.2    Nioradze, N.3    Amemiya, S.4
  • 14
    • 84866149206 scopus 로고    scopus 로고
    • Double-polymer-modified pencil lead for stripping voltammetry of perchlorate in drinking water
    • A. Izadyar, Y. Kim, M.M. Ward Muscatello, and S. Amemiya Double-polymer-modified pencil lead for stripping voltammetry of perchlorate in drinking water J. Chem. Educ. 89 2013 1323 1326
    • (2013) J. Chem. Educ. , vol.89 , pp. 1323-1326
    • Izadyar, A.1    Kim, Y.2    Ward Muscatello, M.M.3    Amemiya, S.4
  • 15
    • 80053522054 scopus 로고    scopus 로고
    • Electrochemical mechanism of ion-ionophore recognition at plasticized polymer membrane/water interfaces
    • R. Ishimatsu, A. Izadyar, B. Kabagambe, Y. Kim, J. Kim, and S. Amemiya Electrochemical mechanism of ion-ionophore recognition at plasticized polymer membrane/water interfaces J. Am. Chem. Soc. 133 2011 16300 16308
    • (2011) J. Am. Chem. Soc. , vol.133 , pp. 16300-16308
    • Ishimatsu, R.1    Izadyar, A.2    Kabagambe, B.3    Kim, Y.4    Kim, J.5    Amemiya, S.6
  • 20
    • 84899484575 scopus 로고    scopus 로고
    • Fish on Prozac (and Zoloft): Ten years later
    • B.W. Brooks Fish on Prozac (and Zoloft): ten years later Aquat. Toxicol. 151 2014 61 67
    • (2014) Aquat. Toxicol. , vol.151 , pp. 61-67
    • Brooks, B.W.1
  • 21
  • 22
    • 79955931363 scopus 로고    scopus 로고
    • Impact of fluoxetine on liver damage in rats
    • I. Inkielewicz-Stepniak Impact of fluoxetine on liver damage in rats Pharmacol. Rep. 63 2011 441 447
    • (2011) Pharmacol. Rep. , vol.63 , pp. 441-447
    • Inkielewicz-Stepniak, I.1
  • 23
    • 0344110152 scopus 로고    scopus 로고
    • Pharmacokinetics of selective serotonin reuptake inhibitors
    • C. Hiemke, and S. Härtter Pharmacokinetics of selective serotonin reuptake inhibitors Pharmacol. Ther. 85 2000 11 28
    • (2000) Pharmacol. Ther. , vol.85 , pp. 11-28
    • Hiemke, C.1    Härtter, S.2
  • 24
    • 24144481472 scopus 로고    scopus 로고
    • Fluoxetine (Prozac) interaction with the mitochondrial voltage-dependent anion channel and protection against apoptotic cell death
    • E. Nahon, A. Israelson, S. Abu-Hamad, and V. Shoshan-Barmatz Fluoxetine (Prozac) interaction with the mitochondrial voltage-dependent anion channel and protection against apoptotic cell death FEBS Lett. 579 2005 5105 5110
    • (2005) FEBS Lett. , vol.579 , pp. 5105-5110
    • Nahon, E.1    Israelson, A.2    Abu-Hamad, S.3    Shoshan-Barmatz, V.4
  • 25
    • 77952546621 scopus 로고    scopus 로고
    • Removal of pharmaceutical and personal care products (PPCPs) under nitrifying and denitrifying conditions
    • S. Sonia, J.M. Lema, and F. Omil Removal of pharmaceutical and personal care products (PPCPs) under nitrifying and denitrifying conditions Water Res. 44 2010 3214 3224
    • (2010) Water Res. , vol.44 , pp. 3214-3224
    • Sonia, S.1    Lema, J.M.2    Omil, F.3
  • 26
    • 33745597369 scopus 로고    scopus 로고
    • Electrochemical determination of citalopram by adsorptive stripping voltammetry - Determination in pharmaceutical products
    • H. Nouws, C.D. Matos, and A.A. Barros Electrochemical determination of citalopram by adsorptive stripping voltammetry - determination in pharmaceutical products Anal. Lett. 39 2006 1907 1915
    • (2006) Anal. Lett. , vol.39 , pp. 1907-1915
    • Nouws, H.1    Matos, C.D.2    Barros, A.A.3
  • 27
    • 49749148361 scopus 로고    scopus 로고
    • Static and hydrodynamic monitoring of citalopram based on its electro-oxidation behavior at a glassy-carbon surface
    • H. Nouws, C.D. Matos, A.A. Barros, E. Maesen, S.C.P.A. Moreira, and M.M.P.S. Neves Static and hydrodynamic monitoring of citalopram based on its electro-oxidation behavior at a glassy-carbon surface Anal. Lett. 41 2008 2171 2185
    • (2008) Anal. Lett. , vol.41 , pp. 2171-2185
    • Nouws, H.1    Matos, C.D.2    Barros, A.A.3    Maesen, E.4    Moreira, S.C.P.A.5    Neves, M.M.P.S.6
  • 28
    • 34249015355 scopus 로고    scopus 로고
    • Square-wave adsorptive-stripping voltammetric detection in the quality control of fluoxetine
    • H. Nouws, C.D. Matos, A.A. Barros, and J.A. Rodrigues Square-wave adsorptive-stripping voltammetric detection in the quality control of fluoxetine Anal. Lett. 40 2007 1131 1146
    • (2007) Anal. Lett. , vol.40 , pp. 1131-1146
    • Nouws, H.1    Matos, C.D.2    Barros, A.A.3    Rodrigues, J.A.4
  • 29
    • 33751354780 scopus 로고    scopus 로고
    • Voltammetric quantification of fluoxetine: Application to quality control and quality assurance processes
    • R. Lencastre, C.D. Matos, J. Garrido, F. Borges, and E.M. Garrido Voltammetric quantification of fluoxetine: application to quality control and quality assurance processes J. Food Drug Anal. 14 2006 242 246
    • (2006) J. Food Drug Anal. , vol.14 , pp. 242-246
    • Lencastre, R.1    Matos, C.D.2    Garrido, J.3    Borges, F.4    Garrido, E.M.5
  • 30
    • 77955642210 scopus 로고    scopus 로고
    • Construction of a fluoxetine ion chemical sensor and its application for the determination of pKa value of fluoxetine conjugated acid, complexation study with β-cyclodextrin and formulations assay
    • E.S. Papas, C.N. Chaldezos, J.J. Atta-Politou, and M.A. Koupparis Construction of a fluoxetine ion chemical sensor and its application for the determination of pKa value of fluoxetine conjugated acid, complexation study with β-cyclodextrin and formulations assay Anal. Lett. 43 2010 2171 2183
    • (2010) Anal. Lett. , vol.43 , pp. 2171-2183
    • Papas, E.S.1    Chaldezos, C.N.2    Atta-Politou, J.J.3    Koupparis, M.A.4
  • 31
    • 84879952284 scopus 로고    scopus 로고
    • Electrochemical detection of fluoxetine using a boron-doped diamond electrode
    • A. Magdalena, M. Florica, and P. Rodica Electrochemical detection of fluoxetine using a boron-doped diamond electrode Int. J. Pharm. Pharm. Sci. 5 2013 318 322
    • (2013) Int. J. Pharm. Pharm. Sci. , vol.5 , pp. 318-322
    • Magdalena, A.1    Florica, M.2    Rodica, P.3
  • 32
    • 49449102377 scopus 로고    scopus 로고
    • Stripping analysis of nanomolar perchlorate in drinking water with a voltammetric ion-selective electrode based on thin-layer liquid membrane
    • Y. Kim, and S. Amemiya Stripping analysis of nanomolar perchlorate in drinking water with a voltammetric ion-selective electrode based on thin-layer liquid membrane Anal. Chem. 80 2008 6056 6065
    • (2008) Anal. Chem. , vol.80 , pp. 6056-6065
    • Kim, Y.1    Amemiya, S.2
  • 33
    • 84922551974 scopus 로고    scopus 로고
    • Ion-transfer voltammetry of perfluoroalkanesulfonates and perfluoroalkanecarboxylates: Picomolar detection limit and high lipophilicity
    • M.B. Garada, B. Kabagambe, Y. Kim, and S. Amemiya Ion-transfer voltammetry of perfluoroalkanesulfonates and perfluoroalkanecarboxylates: picomolar detection limit and high lipophilicity Anal. Chem. 86 2014 11230 11237
    • (2014) Anal. Chem. , vol.86 , pp. 11230-11237
    • Garada, M.B.1    Kabagambe, B.2    Kim, Y.3    Amemiya, S.4
  • 35
    • 64649098325 scopus 로고    scopus 로고
    • Ion-transfer voltammetric determination of the β-blocker propranolol in a physiological matrix at silicon membrane-based liquid/liquid microinterface arrays
    • C.J. Collins, and D.W.M. Arrigan Ion-transfer voltammetric determination of the β-blocker propranolol in a physiological matrix at silicon membrane-based liquid/liquid microinterface arrays Anal. Chem. 81 2009 2344 2349
    • (2009) Anal. Chem. , vol.81 , pp. 2344-2349
    • Collins, C.J.1    Arrigan, D.W.M.2
  • 36
    • 75749133556 scopus 로고    scopus 로고
    • Serum-protein effects on the detection of the β-blocker propranolol by ion-transfer voltammetry at a micro-ITIES array
    • C.J. Collins, C. Lyons, J. Strutwolf, and D.W.M. Arrigan Serum-protein effects on the detection of the β-blocker propranolol by ion-transfer voltammetry at a micro-ITIES array Talanta 80 2010 1993
    • (2010) Talanta , vol.80 , pp. 1993
    • Collins, C.J.1    Lyons, C.2    Strutwolf, J.3    Arrigan, D.W.M.4
  • 37
    • 33749520662 scopus 로고    scopus 로고
    • Metal/polypyrrole quasi-reference electrode for voltammetry in nonaqueous and aqueous solutions
    • J. Ghilane, P. Hapiot, and A. Bard Metal/polypyrrole quasi-reference electrode for voltammetry in nonaqueous and aqueous solutions Anal. Chem. 78 2006 6868 6872
    • (2006) Anal. Chem. , vol.78 , pp. 6868-6872
    • Ghilane, J.1    Hapiot, P.2    Bard, A.3
  • 38
    • 84874297756 scopus 로고    scopus 로고
    • Selective serotonin reuptake inhibitors (SSRIs) inhibit insulin secretion and action in pancreatic β cells
    • R. Isaac, S. Boura-Halfon, D. Gurevitch, A. Shainskaya, Y. Levkovitz, and Y. Zick Selective serotonin reuptake inhibitors (SSRIs) inhibit insulin secretion and action in pancreatic β cells J. Biol. Chem. 228 2013 5682 5693
    • (2013) J. Biol. Chem. , vol.228 , pp. 5682-5693
    • Isaac, R.1    Boura-Halfon, S.2    Gurevitch, D.3    Shainskaya, A.4    Levkovitz, Y.5    Zick, Y.6
  • 39
    • 0344110152 scopus 로고    scopus 로고
    • Pharmacokinetics of selective serotonin reuptake inhibitors
    • C. Hiemke, and S. Hartter Pharmacokinetics of selective serotonin reuptake inhibitors Pharmacol. Ther. 85 2000 11 28
    • (2000) Pharmacol. Ther. , vol.85 , pp. 11-28
    • Hiemke, C.1    Hartter, S.2
  • 40
    • 0029826781 scopus 로고    scopus 로고
    • Pharmacokinetic-pharmacodynamic relationship of the selective serotonin reuptake inhibitors
    • P. Baumann Pharmacokinetic-pharmacodynamic relationship of the selective serotonin reuptake inhibitors Clin. Pharmacokinet. 31 1996 444 469
    • (1996) Clin. Pharmacokinet. , vol.31 , pp. 444-469
    • Baumann, P.1
  • 41
    • 33749468977 scopus 로고    scopus 로고
    • Voltammetric heparin-selective electrode based on thin liquid membrane with conducting polymer-modified solid support
    • J. Guo, and S. Amemiya Voltammetric heparin-selective electrode based on thin liquid membrane with conducting polymer-modified solid support Anal. Chem. 78 2006 6893 6902
    • (2006) Anal. Chem. , vol.78 , pp. 6893-6902
    • Guo, J.1    Amemiya, S.2
  • 42
    • 84873338257 scopus 로고    scopus 로고
    • Electrochemical study of the anticancer drug daunorubicin at a water/oil interface: Drug lipophilicity and quantification
    • J.A. Ribeiro, F. Silva, and C.M. Pereira Electrochemical study of the anticancer drug daunorubicin at a water/oil interface: drug lipophilicity and quantification Anal. Chem. 85 2013 1582 1590
    • (2013) Anal. Chem. , vol.85 , pp. 1582-1590
    • Ribeiro, J.A.1    Silva, F.2    Pereira, C.M.3
  • 43
    • 44949192012 scopus 로고    scopus 로고
    • Electrochemical recognition of synthetic heparin mimetic at liquid/liquid microinterfaces
    • P.J. Rodgers, P. Jing, Y. Kim, and S. Amemiya Electrochemical recognition of synthetic heparin mimetic at liquid/liquid microinterfaces J. Am. Chem. Soc. 130 2008 7436 7442
    • (2008) J. Am. Chem. Soc. , vol.130 , pp. 7436-7442
    • Rodgers, P.J.1    Jing, P.2    Kim, Y.3    Amemiya, S.4
  • 44
  • 45
    • 84865066380 scopus 로고    scopus 로고
    • Using ion-selective electrodes to study the drug release from porous cellulose matrices
    • H. Vakili, N. Genina, H. Ehlers, J. Bobacka, and N. Sandler Using ion-selective electrodes to study the drug release from porous cellulose matrices Pharmaceutics 4 2012 366 376
    • (2012) Pharmaceutics , vol.4 , pp. 366-376
    • Vakili, H.1    Genina, N.2    Ehlers, H.3    Bobacka, J.4    Sandler, N.5
  • 46
    • 84892990405 scopus 로고    scopus 로고
    • Pencil drawn strain gauges and chemiresistors on paper
    • C.W. Lin, Z. Zhao, J. Kim, and J. Huang Pencil drawn strain gauges and chemiresistors on paper Sci. Rep. 4 2014 1 6
    • (2014) Sci. Rep. , vol.4 , pp. 1-6
    • Lin, C.W.1    Zhao, Z.2    Kim, J.3    Huang, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.