메뉴 건너뛰기




Volumn 3, Issue 3, 2015, Pages 335-349.e5

Using Electronic Monitoring Devices to Measure Inhaler Adherence: A Practical Guide for Clinicians

Author keywords

Adherence; Electronic devices; Electronics; Equipment and supplies; Materials testing; Medication adherence; Quality control; Remote sensing technology

Indexed keywords

ARTICLE; CLINICAL PRACTICE; COST EFFECTIVENESS ANALYSIS; DEVICE APPROVAL; DEVICE FAILURE; DEVICE MAINTENANCE; ELECTRONIC MONITORING DEVICE; GLOBAL POSITIONING SYSTEM; INHALER; INSURANCE; MEDICAL DEVICE REGULATION; MONITOR; PATIENT COMPLIANCE; PRACTICE GUIDELINE; QUALITY CONTROL PROCEDURES; SENSOR; DEVICES; DRUG ADMINISTRATION; EQUIPMENT DESIGN; FOOD AND DRUG ADMINISTRATION; HUMAN; INHALATIONAL DRUG ADMINISTRATION; MEDICATION COMPLIANCE; NEBULIZER; REMOTE SENSING; REPRODUCIBILITY; SIGNAL PROCESSING; STANDARDS; TIME FACTOR; UNITED STATES;

EID: 84943451972     PISSN: 22132198     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jaip.2015.01.024     Document Type: Article
Times cited : (94)

References (78)
  • 1
    • 79952202732 scopus 로고    scopus 로고
    • Improving adherence with inhaler therapy in COPD
    • Lareau S., Yawn B. Improving adherence with inhaler therapy in COPD. Int J Chron Obstruct Pulmon Dis 2010, 5:401-406.
    • (2010) Int J Chron Obstruct Pulmon Dis , vol.5 , pp. 401-406
    • Lareau, S.1    Yawn, B.2
  • 3
    • 0141886534 scopus 로고    scopus 로고
    • Inhaled corticosteroids for asthma therapy: patient compliance, devices, and inhalation technique
    • Cochrane M.G., Bala M.V., Downs K.E., Mauskopf J., Ben-Joseph R.H. Inhaled corticosteroids for asthma therapy: patient compliance, devices, and inhalation technique. Chest 2000, 117:542-550.
    • (2000) Chest , vol.117 , pp. 542-550
    • Cochrane, M.G.1    Bala, M.V.2    Downs, K.E.3    Mauskopf, J.4    Ben-Joseph, R.H.5
  • 4
    • 71949106729 scopus 로고    scopus 로고
    • Medication adherence feedback to improve asthma outcomes among inner-city children: a randomized controlled trial
    • Otsuki M., Eakin M.N., Rand C.S., Butz A.M., Hsu V.D., Zuckerman I.H., et al. Medication adherence feedback to improve asthma outcomes among inner-city children: a randomized controlled trial. Pediatrics 2009, 124:1513-1521.
    • (2009) Pediatrics , vol.124 , pp. 1513-1521
    • Otsuki, M.1    Eakin, M.N.2    Rand, C.S.3    Butz, A.M.4    Hsu, V.D.5    Zuckerman, I.H.6
  • 5
    • 9644291519 scopus 로고    scopus 로고
    • Relationship between adherence to inhaled corticosteroids and poor outcomes among adults with asthma
    • Williams L.K., Pladevall M., Xi H., Peterson E.L., Joseph C., Lafata J.E., et al. Relationship between adherence to inhaled corticosteroids and poor outcomes among adults with asthma. J Allergy Clin Immunol 2004, 114:1288-1293.
    • (2004) J Allergy Clin Immunol , vol.114 , pp. 1288-1293
    • Williams, L.K.1    Pladevall, M.2    Xi, H.3    Peterson, E.L.4    Joseph, C.5    Lafata, J.E.6
  • 7
    • 0034601431 scopus 로고    scopus 로고
    • Low-dose inhaled corticosteroids and the prevention of death from asthma
    • Suissa S., Ernst P., Benayoun S., Baltzan M., Cai B. Low-dose inhaled corticosteroids and the prevention of death from asthma. N Engl J Med 2000, 343:332-336.
    • (2000) N Engl J Med , vol.343 , pp. 332-336
    • Suissa, S.1    Ernst, P.2    Benayoun, S.3    Baltzan, M.4    Cai, B.5
  • 8
    • 0033611298 scopus 로고    scopus 로고
    • Treatment patterns among adult patients with asthma: factors associated with overuse of inhaled beta-agonists and underuse of inhaled corticosteroids
    • Diette G.B., Wu A.W., Skinner E.A., Markson L., Clark R.D., McDonald R.C., et al. Treatment patterns among adult patients with asthma: factors associated with overuse of inhaled beta-agonists and underuse of inhaled corticosteroids. Arch Intern Med 1999, 159:2697-2704.
    • (1999) Arch Intern Med , vol.159 , pp. 2697-2704
    • Diette, G.B.1    Wu, A.W.2    Skinner, E.A.3    Markson, L.4    Clark, R.D.5    McDonald, R.C.6
  • 9
    • 84884694448 scopus 로고    scopus 로고
    • Metrics of salbutamol use as predictors of future adverse outcomes in asthma
    • Patel M., Pilcher J., Reddel H.K., Pritchard A., Corin A., Helm C., et al. Metrics of salbutamol use as predictors of future adverse outcomes in asthma. Clin Exp Allergy 2013, 43:1144-1151.
    • (2013) Clin Exp Allergy , vol.43 , pp. 1144-1151
    • Patel, M.1    Pilcher, J.2    Reddel, H.K.3    Pritchard, A.4    Corin, A.5    Helm, C.6
  • 11
    • 0027980288 scopus 로고
    • Patterns of increasing beta-agonist use and the risk of fatal or near-fatal asthma
    • Suissa S., Blais L., Ernst P. Patterns of increasing beta-agonist use and the risk of fatal or near-fatal asthma. Eur Respir J 1994, 7:1602-1609.
    • (1994) Eur Respir J , vol.7 , pp. 1602-1609
    • Suissa, S.1    Blais, L.2    Ernst, P.3
  • 12
    • 30844443967 scopus 로고    scopus 로고
    • Inappropriate use of inhaled short acting beta-agonists and its association with patient health status
    • Hee Hong S., Sanders B.H., West D. Inappropriate use of inhaled short acting beta-agonists and its association with patient health status. Curr Med Res Opin 2006, 22:33-40.
    • (2006) Curr Med Res Opin , vol.22 , pp. 33-40
    • Hee Hong, S.1    Sanders, B.H.2    West, D.3
  • 13
    • 0033645783 scopus 로고    scopus 로고
    • Measurement of children's asthma medication adherence by self report, mother report, canister weight, and Doser CT
    • Bender B., Wamboldt F.S., O'Connor S.L., Rand C., Szefler S., Milgrom H., et al. Measurement of children's asthma medication adherence by self report, mother report, canister weight, and Doser CT. Ann Allergy Asthma Immunol 2000, 85:416-421.
    • (2000) Ann Allergy Asthma Immunol , vol.85 , pp. 416-421
    • Bender, B.1    Wamboldt, F.S.2    O'Connor, S.L.3    Rand, C.4    Szefler, S.5    Milgrom, H.6
  • 14
    • 70349200852 scopus 로고    scopus 로고
    • Monitoring adherence to beclomethasone in asthmatic children and adolescents through four different methods
    • Jentzsch N.S., Camargos P.A., Colosimo E.A., Bousquet J. Monitoring adherence to beclomethasone in asthmatic children and adolescents through four different methods. Allergy 2009, 64:1458-1462.
    • (2009) Allergy , vol.64 , pp. 1458-1462
    • Jentzsch, N.S.1    Camargos, P.A.2    Colosimo, E.A.3    Bousquet, J.4
  • 15
    • 44249118118 scopus 로고    scopus 로고
    • Assessing adherence and factors associated with adherence in young children with asthma
    • Burgess S.W., Sly P.D., Morawska A., Devadason S.G. Assessing adherence and factors associated with adherence in young children with asthma. Respirology 2008, 13:559-563.
    • (2008) Respirology , vol.13 , pp. 559-563
    • Burgess, S.W.1    Sly, P.D.2    Morawska, A.3    Devadason, S.G.4
  • 16
    • 0037032058 scopus 로고    scopus 로고
    • Provider inaccuracy in assessing adherence and outcomes with newly initiated antiretroviral therapy
    • Gross R., Bilker W.B., Friedman H.M., Coyne J.C., Strom B.L. Provider inaccuracy in assessing adherence and outcomes with newly initiated antiretroviral therapy. AIDS 2002, 16:1835-1837.
    • (2002) AIDS , vol.16 , pp. 1835-1837
    • Gross, R.1    Bilker, W.B.2    Friedman, H.M.3    Coyne, J.C.4    Strom, B.L.5
  • 17
    • 55449088648 scopus 로고    scopus 로고
    • Physicians' ability to predict patients' adherence to antihypertensive medication in primary care
    • Zeller A., Taegtmeyer A., Martina B., Battegay E., Tschudi P. Physicians' ability to predict patients' adherence to antihypertensive medication in primary care. Hypertens Res 2008, 31:1765-1771.
    • (2008) Hypertens Res , vol.31 , pp. 1765-1771
    • Zeller, A.1    Taegtmeyer, A.2    Martina, B.3    Battegay, E.4    Tschudi, P.5
  • 18
    • 35648953316 scopus 로고    scopus 로고
    • Patients with asthma who do not fill their inhaled corticosteroids: a study of primary nonadherence
    • Williams L.K., Joseph C.L., Peterson E.L., Wells K., Wang M., Chowdhry V.K., et al. Patients with asthma who do not fill their inhaled corticosteroids: a study of primary nonadherence. J Allergy Clin Immunol 2007, 120:1153-1159.
    • (2007) J Allergy Clin Immunol , vol.120 , pp. 1153-1159
    • Williams, L.K.1    Joseph, C.L.2    Peterson, E.L.3    Wells, K.4    Wang, M.5    Chowdhry, V.K.6
  • 19
    • 53049104692 scopus 로고    scopus 로고
    • Methods of assessing adherence to inhaled corticosteroid therapy in children and adolescents: adherence rates and their implications for clinical practice
    • Jentzsch N.S., Camargos P.A. Methods of assessing adherence to inhaled corticosteroid therapy in children and adolescents: adherence rates and their implications for clinical practice. J Bras Pneumol 2008, 34:614-621.
    • (2008) J Bras Pneumol , vol.34 , pp. 614-621
    • Jentzsch, N.S.1    Camargos, P.A.2
  • 20
    • 84857622088 scopus 로고    scopus 로고
    • Treatment adherence and psychosocial factors in severe asthma
    • European Respiratory Society Monograph, London, UK, K.F. Chung, E. Bel, S. Wenzel (Eds.)
    • Foster J.M., Lavoie K.L., Boulet L. Treatment adherence and psychosocial factors in severe asthma. Difficult-to-Treat Asthma 2011, 28-49. European Respiratory Society Monograph, London, UK. K.F. Chung, E. Bel, S. Wenzel (Eds.).
    • (2011) Difficult-to-Treat Asthma , pp. 28-49
    • Foster, J.M.1    Lavoie, K.L.2    Boulet, L.3
  • 21
    • 43349102209 scopus 로고    scopus 로고
    • Examining assumptions regarding valid electronic monitoring of medication therapy: development of a validation framework and its application on a European sample of kidney transplant patients
    • Denhaerynck K., Schafer-Keller P., Young J., Steiger J., Bock A., De Geest S. Examining assumptions regarding valid electronic monitoring of medication therapy: development of a validation framework and its application on a European sample of kidney transplant patients. BMC Med Res Methodol 2008, 8:5.
    • (2008) BMC Med Res Methodol , vol.8 , pp. 5
    • Denhaerynck, K.1    Schafer-Keller, P.2    Young, J.3    Steiger, J.4    Bock, A.5    De Geest, S.6
  • 22
    • 80052794421 scopus 로고    scopus 로고
    • Electronic measurement of medication adherence in pediatric chronic illness: a review of measures
    • Ingerski L.M., Hente E.A., Modi A.C., Hommel K.A. Electronic measurement of medication adherence in pediatric chronic illness: a review of measures. J Pediatr 2011, 159:528-534.
    • (2011) J Pediatr , vol.159 , pp. 528-534
    • Ingerski, L.M.1    Hente, E.A.2    Modi, A.C.3    Hommel, K.A.4
  • 23
    • 84907614254 scopus 로고    scopus 로고
    • Remote patient monitoring: how mobile devices will curb chronic conditions
    • Morrissey J. Remote patient monitoring: how mobile devices will curb chronic conditions. Med Econ July 8, 2014.
    • (2014) Med Econ
    • Morrissey, J.1
  • 26
    • 52749084914 scopus 로고    scopus 로고
    • Cost comparison between telemonitoring and usual care of heart failure: a systematic review
    • Seto E. Cost comparison between telemonitoring and usual care of heart failure: a systematic review. Telemed J E Health 2008, 14:679-686.
    • (2008) Telemed J E Health , vol.14 , pp. 679-686
    • Seto, E.1
  • 27
    • 15344346886 scopus 로고    scopus 로고
    • The current state of telemonitoring: a comment on the literature
    • Meystre S. The current state of telemonitoring: a comment on the literature. Telemed J E Health 2005, 11:63-69.
    • (2005) Telemed J E Health , vol.11 , pp. 63-69
    • Meystre, S.1
  • 29
    • 84883503739 scopus 로고    scopus 로고
    • An official American Thoracic Society statement: continuous positive airway pressure adherence tracking systems. The optimal monitoring strategies and outcome measures in adults
    • ATS Subcommittee on CPAP Adherence Tracking Systems
    • Schwab R.J., Badr S.M., Epstein L.J., Gay P.C., Gozal D., Kohler M., et al. An official American Thoracic Society statement: continuous positive airway pressure adherence tracking systems. The optimal monitoring strategies and outcome measures in adults. Am J Respir Crit Care Med 2013, 188:613-620. ATS Subcommittee on CPAP Adherence Tracking Systems.
    • (2013) Am J Respir Crit Care Med , vol.188 , pp. 613-620
    • Schwab, R.J.1    Badr, S.M.2    Epstein, L.J.3    Gay, P.C.4    Gozal, D.5    Kohler, M.6
  • 31
    • 84863923721 scopus 로고    scopus 로고
    • The reliability and patient acceptability of the SmartTrack device: a new electronic monitor and reminder device for metered dose inhalers
    • Foster J.M., Smith L., Usherwood T., Sawyer S.M., Rand C.S., Reddel H.K. The reliability and patient acceptability of the SmartTrack device: a new electronic monitor and reminder device for metered dose inhalers. J Asthma 2012, 49:657-662.
    • (2012) J Asthma , vol.49 , pp. 657-662
    • Foster, J.M.1    Smith, L.2    Usherwood, T.3    Sawyer, S.M.4    Rand, C.S.5    Reddel, H.K.6
  • 36
    • 84870291047 scopus 로고    scopus 로고
    • Six-month in vitro validation of a metered-dose inhaler electronic monitoring device: implications for asthma clinical trial use
    • Patel M., Pilcher J., Chan A., Perrin K., Black P., Beasley R. Six-month in vitro validation of a metered-dose inhaler electronic monitoring device: implications for asthma clinical trial use. J Allergy Clin Immunol 2012, 130:1420-1422.
    • (2012) J Allergy Clin Immunol , vol.130 , pp. 1420-1422
    • Patel, M.1    Pilcher, J.2    Chan, A.3    Perrin, K.4    Black, P.5    Beasley, R.6
  • 37
    • 4944231978 scopus 로고    scopus 로고
    • Adherence logger for a dry powder inhaler: a new device for medical adherence research
    • Bogen D., Apter A.J. Adherence logger for a dry powder inhaler: a new device for medical adherence research. J Allergy Clin Immunol 2004, 114:863-868.
    • (2004) J Allergy Clin Immunol , vol.114 , pp. 863-868
    • Bogen, D.1    Apter, A.J.2
  • 38
    • 84877018717 scopus 로고    scopus 로고
    • Advancing the science of adherence measurement: implications for the clinician
    • Bender B.G. Advancing the science of adherence measurement: implications for the clinician. J Allergy Clin Immunol Pract 2013, 1:92-93.
    • (2013) J Allergy Clin Immunol Pract , vol.1 , pp. 92-93
    • Bender, B.G.1
  • 39
    • 80053929592 scopus 로고    scopus 로고
    • How to test electronic adherence monitoring devices for use in daily life: a conceptual framework
    • De Bleser L.J., De Geest S., Vincke B., Ruppar T., Vanhaecke J., Dobbels F. How to test electronic adherence monitoring devices for use in daily life: a conceptual framework. Comput Inform Nurs 2011, 29:489-495.
    • (2011) Comput Inform Nurs , vol.29 , pp. 489-495
    • De Bleser, L.J.1    De Geest, S.2    Vincke, B.3    Ruppar, T.4    Vanhaecke, J.5    Dobbels, F.6
  • 40
    • 0036231720 scopus 로고    scopus 로고
    • Electronic monitoring of medication adherence: when is high-tech best?
    • Riekert K.A., Rand C.S. Electronic monitoring of medication adherence: when is high-tech best?. J Clin Psychol Med Sett 2002, 9:25-34.
    • (2002) J Clin Psychol Med Sett , vol.9 , pp. 25-34
    • Riekert, K.A.1    Rand, C.S.2
  • 41
    • 34047191788 scopus 로고    scopus 로고
    • An audiovisual reminder function improves adherence with inhaled corticosteroid therapy in asthma
    • Charles T., Quinn D., Weatherall M., Aldington S., Beasley R., Holt S. An audiovisual reminder function improves adherence with inhaled corticosteroid therapy in asthma. J Allergy Clin Immunol 2007, 119:811-816.
    • (2007) J Allergy Clin Immunol , vol.119 , pp. 811-816
    • Charles, T.1    Quinn, D.2    Weatherall, M.3    Aldington, S.4    Beasley, R.5    Holt, S.6
  • 42
    • 84919840145 scopus 로고    scopus 로고
    • Inhaler reminders improve adherence with controller treatment in primary care patients with asthma
    • Foster J.M., Usherwood T., Smith L., Sawyer S.M., Xuan W., Rand C.S., et al. Inhaler reminders improve adherence with controller treatment in primary care patients with asthma. J Allergy Clin Immunol 2014, 134:1260-1268.
    • (2014) J Allergy Clin Immunol , vol.134 , pp. 1260-1268
    • Foster, J.M.1    Usherwood, T.2    Smith, L.3    Sawyer, S.M.4    Xuan, W.5    Rand, C.S.6
  • 43
    • 85010392731 scopus 로고    scopus 로고
    • Monitoring and improving compliance and asthma control: mapping inhaler use for feedback to patients, physicians and payers
    • Berlin, Germany.
    • Van Sickle D, Maenner M, Barrett M, Marcus J. Monitoring and improving compliance and asthma control: mapping inhaler use for feedback to patients, physicians and payers. Respir Drug Delivery Europe Conference, 2013; Berlin, Germany.
    • (2013) Respir Drug Delivery Europe Conference
    • Van Sickle, D.1    Maenner, M.2    Barrett, M.3    Marcus, J.4
  • 44
    • 84877026665 scopus 로고    scopus 로고
    • Use of metered-dose inhaler electronic monitoring in a real-world asthma randomized controlled trial
    • Patel M., Pilcher J., Travers J., Perrin K., Shaw D., Black P., et al. Use of metered-dose inhaler electronic monitoring in a real-world asthma randomized controlled trial. J Allergy Clin Immunol Pract 2013, 1:83-91.
    • (2013) J Allergy Clin Immunol Pract , vol.1 , pp. 83-91
    • Patel, M.1    Pilcher, J.2    Travers, J.3    Perrin, K.4    Shaw, D.5    Black, P.6
  • 45
    • 0036202243 scopus 로고    scopus 로고
    • Accuracy of three electronic monitors for metered-dose inhalers
    • Julius S.M., Sherman J.M., Hendeles L. Accuracy of three electronic monitors for metered-dose inhalers. Chest 2002, 121:871-876.
    • (2002) Chest , vol.121 , pp. 871-876
    • Julius, S.M.1    Sherman, J.M.2    Hendeles, L.3
  • 46
    • 84857978709 scopus 로고    scopus 로고
    • Feasibility and acceptability of using bronchial hyperresponsiveness to manage asthma in primary care: a pilot study
    • Turtona J.A., Glasgow N.J., Brannan J.D. Feasibility and acceptability of using bronchial hyperresponsiveness to manage asthma in primary care: a pilot study. Prim Care Respir J 2012, 21:28-34.
    • (2012) Prim Care Respir J , vol.21 , pp. 28-34
    • Turtona, J.A.1    Glasgow, N.J.2    Brannan, J.D.3
  • 47
    • 84877011440 scopus 로고    scopus 로고
    • Asthma adherence management for the clinician
    • Weinstein A.G. Asthma adherence management for the clinician. J Allergy Clin Immunol Pract 2013, 1:123-128.
    • (2013) J Allergy Clin Immunol Pract , vol.1 , pp. 123-128
    • Weinstein, A.G.1
  • 48
    • 84892766762 scopus 로고    scopus 로고
    • FDA authorization of medical devices
    • Jin J. FDA authorization of medical devices. JAMA 2014, 311:435.
    • (2014) JAMA , vol.311 , pp. 435
    • Jin, J.1
  • 49
    • 84953889901 scopus 로고    scopus 로고
    • Emergo Group, Emergo Consulting, Austin, Texas, Available from:, Accessed January 4, 2014
    • Regulatory Consulting 2014, Emergo Group, Emergo Consulting, Austin, Texas, Available from: http://www.emergogroup.com/services/regulatory-overview?pi_ad_id=48346692501&_kk=medical%20device%20approval&_kt=4a041798-3d65-4c19-bb97-c684c32fe275&gclid=CMODjPWK2cICFRRwvAodm7QA0A. Accessed January 4, 2014.
    • (2014) Regulatory Consulting
  • 50
    • 84887114787 scopus 로고    scopus 로고
    • FDA lays out rules for regulating mobile medical apps
    • Mitka M. FDA lays out rules for regulating mobile medical apps. JAMA 2013, 310:1783-1784.
    • (2013) JAMA , vol.310 , pp. 1783-1784
    • Mitka, M.1
  • 51
    • 84884188665 scopus 로고    scopus 로고
    • The HIPAA conundrum in the era of mobile health and communications
    • Wang C., Huang D.J. The HIPAA conundrum in the era of mobile health and communications. JAMA 2013, 310:1121-1122.
    • (2013) JAMA , vol.310 , pp. 1121-1122
    • Wang, C.1    Huang, D.J.2
  • 52
    • 84857965275 scopus 로고    scopus 로고
    • PricewaterhouseCoopers' Health Research Institute, Pricewaterhouse Coopers: Healthcare Unwired, New York, NY
    • Healthcare Unwired: New Business Models Delivering Care Anywhere 2010, PricewaterhouseCoopers' Health Research Institute, Pricewaterhouse Coopers: Healthcare Unwired, New York, NY.
    • (2010) Healthcare Unwired: New Business Models Delivering Care Anywhere
  • 53
    • 84908124479 scopus 로고    scopus 로고
    • Economic and health effect of full adherence to controller therapy in adults with uncontrolled asthma: a simulation study
    • Zafari Z., Lynd L.D., FitzGerald J.M., Sadatsafavi M. Economic and health effect of full adherence to controller therapy in adults with uncontrolled asthma: a simulation study. J Allergy Clin Immunol 2014, 134:908-915.e3.
    • (2014) J Allergy Clin Immunol , vol.134 , pp. 908-915.e3
    • Zafari, Z.1    Lynd, L.D.2    FitzGerald, J.M.3    Sadatsafavi, M.4
  • 54
    • 84866994229 scopus 로고    scopus 로고
    • Incorporating electronic monitoring feedback into clinical care: a novel and promising adherence promotion approach
    • Herzer M., Ramey C., Rohan J., Cortina S. Incorporating electronic monitoring feedback into clinical care: a novel and promising adherence promotion approach. Clin Child Psychol Psychiatry 2012, 17:505-518.
    • (2012) Clin Child Psychol Psychiatry , vol.17 , pp. 505-518
    • Herzer, M.1    Ramey, C.2    Rohan, J.3    Cortina, S.4
  • 55
    • 67649502327 scopus 로고    scopus 로고
    • Open adherence monitoring using routine data download from an adaptive aerosol delivery nebuliser in children with cystic fibrosis
    • McNamara P.S., McCormack P., McDonald A.J., Heaf L., Southern K.W. Open adherence monitoring using routine data download from an adaptive aerosol delivery nebuliser in children with cystic fibrosis. J Cyst Fibros 2009, 8:258-263.
    • (2009) J Cyst Fibros , vol.8 , pp. 258-263
    • McNamara, P.S.1    McCormack, P.2    McDonald, A.J.3    Heaf, L.4    Southern, K.W.5
  • 56
    • 18744391652 scopus 로고    scopus 로고
    • Medication compliance during a smoking cessation clinical trial: a brief intervention using MEMS feedback
    • Schmitz J.M., Sayre S.L., Stotts A.L., Rothfleisch J., Mooney M.E. Medication compliance during a smoking cessation clinical trial: a brief intervention using MEMS feedback. J Behav Med 2005, 28:139-147.
    • (2005) J Behav Med , vol.28 , pp. 139-147
    • Schmitz, J.M.1    Sayre, S.L.2    Stotts, A.L.3    Rothfleisch, J.4    Mooney, M.E.5
  • 57
    • 84883443977 scopus 로고    scopus 로고
    • Adherence monitoring and e-health: how clinicians and researchers can use technology to promote inhaler adherence in asthma
    • Chan A.H.Y., Reddel H.K., Apter A., Eakin M., Riekert K., Foster J.M. Adherence monitoring and e-health: how clinicians and researchers can use technology to promote inhaler adherence in asthma. J Allergy Clin Immunol Pract 2013, 1:446-454.
    • (2013) J Allergy Clin Immunol Pract , vol.1 , pp. 446-454
    • Chan, A.H.Y.1    Reddel, H.K.2    Apter, A.3    Eakin, M.4    Riekert, K.5    Foster, J.M.6
  • 59
    • 77955329331 scopus 로고    scopus 로고
    • Electronic monitoring-based counseling to enhance adherence among HIV-infected patients: a randomized controlled trial
    • de Bruin M., Hospers H.J., van Breukelen G.J., Kok G., Koevoets W.M., Prins J.M. Electronic monitoring-based counseling to enhance adherence among HIV-infected patients: a randomized controlled trial. Health Psychol 2010, 29:421-428.
    • (2010) Health Psychol , vol.29 , pp. 421-428
    • de Bruin, M.1    Hospers, H.J.2    van Breukelen, G.J.3    Kok, G.4    Koevoets, W.M.5    Prins, J.M.6
  • 62
    • 0027185144 scopus 로고
    • Improving inhaler adherence in a clinical trial through the use of the nebulizer chronolog
    • Nides M., Tashkin D.P., Simmons M.S., Wise R., Li V.C., Rand C.S. Improving inhaler adherence in a clinical trial through the use of the nebulizer chronolog. Chest 1993, 104:501-507.
    • (1993) Chest , vol.104 , pp. 501-507
    • Nides, M.1    Tashkin, D.P.2    Simmons, M.S.3    Wise, R.4    Li, V.C.5    Rand, C.S.6
  • 63
    • 0035063319 scopus 로고    scopus 로고
    • Testing the reliability of old and new features of a new electronic monitor for metered dose inhalers
    • Apter A.J., Tor M., Feldman H.I. Testing the reliability of old and new features of a new electronic monitor for metered dose inhalers. Ann Allergy Asthma Immunol 2001, 86:421-424.
    • (2001) Ann Allergy Asthma Immunol , vol.86 , pp. 421-424
    • Apter, A.J.1    Tor, M.2    Feldman, H.I.3
  • 64
    • 0028058215 scopus 로고
    • Measuring adherence to asthma medication regimens
    • discussion S77-S78
    • Rand C.S., Wise R.A. Measuring adherence to asthma medication regimens. Am J Respir Crit Care Med 1994, 149:S69-76. discussion S77-S78.
    • (1994) Am J Respir Crit Care Med , vol.149 , pp. S69-76
    • Rand, C.S.1    Wise, R.A.2
  • 65
    • 1042288296 scopus 로고    scopus 로고
    • Medical device regulation: an introduction for the practicing physician
    • Maisel W.H. Medical device regulation: an introduction for the practicing physician. Ann Intern Med 2004, 140:296-302.
    • (2004) Ann Intern Med , vol.140 , pp. 296-302
    • Maisel, W.H.1
  • 66
    • 80053929592 scopus 로고    scopus 로고
    • How to test electronic adherence monitoring devices for use in daily life: a conceptual framework
    • De Bleser L.J., De Geest S., Vincke B., Ruppar T., Vanhaecke J., Dobbels F. How to test electronic adherence monitoring devices for use in daily life: a conceptual framework. Comput Inform Nurs 2011, 29:489-495.
    • (2011) Comput Inform Nurs , vol.29 , pp. 489-495
    • De Bleser, L.J.1    De Geest, S.2    Vincke, B.3    Ruppar, T.4    Vanhaecke, J.5    Dobbels, F.6
  • 67
    • 0036231720 scopus 로고    scopus 로고
    • Electronic monitoring of medication adherence: when is high-tech best?
    • Riekert K.A., Rand C.S. Electronic monitoring of medication adherence: when is high-tech best?. J Clin Psychol Med Sett 2002, 9:25-34.
    • (2002) J Clin Psychol Med Sett , vol.9 , pp. 25-34
    • Riekert, K.A.1    Rand, C.S.2
  • 68
    • 0035063319 scopus 로고    scopus 로고
    • Testing the reliability of old and new features of a new electronic monitor for metered dose inhalers
    • Apter A.J., Tor M., Feldman H.I. Testing the reliability of old and new features of a new electronic monitor for metered dose inhalers. Ann Allergy Asthma Immunol 2001, 86:421-424.
    • (2001) Ann Allergy Asthma Immunol , vol.86 , pp. 421-424
    • Apter, A.J.1    Tor, M.2    Feldman, H.I.3
  • 69
    • 0036202243 scopus 로고    scopus 로고
    • Accuracy of three electronic monitors for metered-dose inhalers
    • Julius S.M., Sherman J.M., Hendeles L. Accuracy of three electronic monitors for metered-dose inhalers. Chest 2002, 121:871-876.
    • (2002) Chest , vol.121 , pp. 871-876
    • Julius, S.M.1    Sherman, J.M.2    Hendeles, L.3
  • 71
    • 0033645783 scopus 로고    scopus 로고
    • Measurement of children's asthma medication adherence by self report, mother report, canister weight, and Doser CT
    • Bender B., Wamboldt F.S., O'Connor S.L., Rand C., Szefler S., Milgrom H., et al. Measurement of children's asthma medication adherence by self report, mother report, canister weight, and Doser CT. Ann Allergy Asthma Immunol 2000, 85:416-421.
    • (2000) Ann Allergy Asthma Immunol , vol.85 , pp. 416-421
    • Bender, B.1    Wamboldt, F.S.2    O'Connor, S.L.3    Rand, C.4    Szefler, S.5    Milgrom, H.6
  • 73
    • 4944231978 scopus 로고    scopus 로고
    • Adherence logger for a dry powder inhaler: a new device for medical adherence research
    • Bogen D., Apter A.J. Adherence logger for a dry powder inhaler: a new device for medical adherence research. J Allergy Clin Immunol 2004, 114:863-868.
    • (2004) J Allergy Clin Immunol , vol.114 , pp. 863-868
    • Bogen, D.1    Apter, A.J.2
  • 77
    • 0034601431 scopus 로고    scopus 로고
    • Low-dose inhaled corticosteroids and the prevention of death from asthma
    • Suissa S., Ernst P., Benayoun S., Baltzan M., Cai B. Low-dose inhaled corticosteroids and the prevention of death from asthma. N Engl J Med 2000, 343:332-336.
    • (2000) N Engl J Med , vol.343 , pp. 332-336
    • Suissa, S.1    Ernst, P.2    Benayoun, S.3    Baltzan, M.4    Cai, B.5
  • 78
    • 84863923721 scopus 로고    scopus 로고
    • The reliability and patient acceptability of the SmartTrack device: a new electronic monitor and reminder device for metered dose inhalers
    • Foster J.M., Smith L., Usherwood T., Sawyer S.M., Rand C.S., Reddel H.K. The reliability and patient acceptability of the SmartTrack device: a new electronic monitor and reminder device for metered dose inhalers. J Asthma 2012, 49:657-662.
    • (2012) J Asthma , vol.49 , pp. 657-662
    • Foster, J.M.1    Smith, L.2    Usherwood, T.3    Sawyer, S.M.4    Rand, C.S.5    Reddel, H.K.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.