메뉴 건너뛰기




Volumn 17, Issue 5, 2015, Pages 844-853

Evaluation of a Novel Cone Beam Computed Tomography Scanner for Bone Density Examinations in Preoperative 3D Reconstructions and Correlation with Primary Implant Stability

Author keywords

Bone density; CBCT; Clinical study; Implant stability; Insertion torque; Resonance frequency

Indexed keywords

TOOTH IMPLANT;

EID: 84943348960     PISSN: 15230899     EISSN: 17088208     Source Type: Journal    
DOI: 10.1111/cid.12193     Document Type: Article
Times cited : (43)

References (24)
  • 1
    • 0032150708 scopus 로고    scopus 로고
    • Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature
    • Sennerby L, Roos J. Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature. Int J Prosthodont 1998; 11:408-420.
    • (1998) Int J Prosthodont , vol.11 , pp. 408-420
    • Sennerby, L.1    Roos, J.2
  • 2
    • 0032151752 scopus 로고    scopus 로고
    • Assessment of implant stability as a prognostic determinant
    • Meredith N. Assessment of implant stability as a prognostic determinant. Int J Prosthodont 1998; 11:491-501.
    • (1998) Int J Prosthodont , vol.11 , pp. 491-501
    • Meredith, N.1
  • 3
    • 42149147336 scopus 로고    scopus 로고
    • Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications
    • Sennerby L, Meredith N. Implant stability measurements using resonance frequency analysis: biological and biomechanical aspects and clinical implications. Periodontol 2000 2008; 47:51-66.
    • (2008) Periodontol 2000 , vol.47 , pp. 51-66
    • Sennerby, L.1    Meredith, N.2
  • 4
    • 0000402785 scopus 로고
    • Assessment of bone quality from cutting resistance during implant surgery
    • Johansson P, Stridh KG. Assessment of bone quality from cutting resistance during implant surgery. Int J Oral Maxillofac Implants 1994; 9:279-288.
    • (1994) Int J Oral Maxillofac Implants , vol.9 , pp. 279-288
    • Johansson, P.1    Stridh, K.G.2
  • 5
    • 0029440426 scopus 로고
    • Identification of bone quality in conjunction with insertion of titanium implants. A pilot study in jaw autopsy specimens
    • Friberg B, Sennerby L, Roos J, Lekholm U. Identification of bone quality in conjunction with insertion of titanium implants. A pilot study in jaw autopsy specimens. Clin Oral Implants Res 1995; 6:213-219.
    • (1995) Clin Oral Implants Res , vol.6 , pp. 213-219
    • Friberg, B.1    Sennerby, L.2    Roos, J.3    Lekholm, U.4
  • 6
    • 0033176199 scopus 로고    scopus 로고
    • A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study
    • Friberg B, Sennerby L, Meredith N, Lekholm U. A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study. Int J Oral Maxillofac Surg 1999; 28:297-303.
    • (1999) Int J Oral Maxillofac Surg , vol.28 , pp. 297-303
    • Friberg, B.1    Sennerby, L.2    Meredith, N.3    Lekholm, U.4
  • 7
    • 33747877743 scopus 로고    scopus 로고
    • A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Brånemark system implants
    • Turkyilmaz I. A comparison between insertion torque and resonance frequency in the assessment of torque capacity and primary stability of Brånemark system implants. J Oral Rehabil 2006; 33:754-759.
    • (2006) J Oral Rehabil , vol.33 , pp. 754-759
    • Turkyilmaz, I.1
  • 9
    • 77449100786 scopus 로고    scopus 로고
    • Computer-aided manufacturing technologies for guided implant placement
    • Neugebauer J, Stachulla G, Ritter L, etal. Computer-aided manufacturing technologies for guided implant placement. Expert Rev Med Devices 2010; 7:113-129.
    • (2010) Expert Rev Med Devices , vol.7 , pp. 113-129
    • Neugebauer, J.1    Stachulla, G.2    Ritter, L.3
  • 10
    • 79960237817 scopus 로고    scopus 로고
    • Ambiguity in bone tissue characteristics as presented in studies on dental implant planning and placement: a systematic review
    • Ribeiro-Rotta RF, Lindh C, Pereira AC, Rohlin M. Ambiguity in bone tissue characteristics as presented in studies on dental implant planning and placement: a systematic review. Clin Oral Implants Res 2011; 22:789-801.
    • (2011) Clin Oral Implants Res , vol.22 , pp. 789-801
    • Ribeiro-Rotta, R.F.1    Lindh, C.2    Pereira, A.C.3    Rohlin, M.4
  • 11
    • 0017665285 scopus 로고
    • A quantitative theory of the Hounsfield unit and its application to dual energy scanning
    • Brooks RA. A quantitative theory of the Hounsfield unit and its application to dual energy scanning. J Comput Assist Tomogr 1977; 1:487-493.
    • (1977) J Comput Assist Tomogr , vol.1 , pp. 487-493
    • Brooks, R.A.1
  • 12
    • 0036082588 scopus 로고    scopus 로고
    • Bone mineral density measurement with dental quantitative CT prior to dental implant placement in cadaver mandibles: pilot study
    • Homolka P, Beer A, Birkfellner W, etal. Bone mineral density measurement with dental quantitative CT prior to dental implant placement in cadaver mandibles: pilot study. Radiology 2002; 224:247-252.
    • (2002) Radiology , vol.224 , pp. 247-252
    • Homolka, P.1    Beer, A.2    Birkfellner, W.3
  • 13
    • 33751351701 scopus 로고    scopus 로고
    • Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement
    • Turkyilmaz I, Tözüm TF, Tumer C, Ozbek EN. Assessment of correlation between computerized tomography values of the bone, and maximum torque and resonance frequency values at dental implant placement. J Oral Rehabil 2006; 33:881-888.
    • (2006) J Oral Rehabil , vol.33 , pp. 881-888
    • Turkyilmaz, I.1    Tözüm, T.F.2    Tumer, C.3    Ozbek, E.N.4
  • 14
    • 34547174147 scopus 로고    scopus 로고
    • Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants
    • Turkyilmaz I, Tumer C, Ozbek EN, Tözüm TF. Relations between the bone density values from computerized tomography, and implant stability parameters: a clinical study of 230 regular platform implants. J Clin Periodontol 2007; 34:716-722.
    • (2007) J Clin Periodontol , vol.34 , pp. 716-722
    • Turkyilmaz, I.1    Tumer, C.2    Ozbek, E.N.3    Tözüm, T.F.4
  • 15
    • 58149330623 scopus 로고    scopus 로고
    • Influence of bone density on implant stability parameters and implant success: a retrospective clinical study
    • Turkyilmaz I, McGlumphy EA. Influence of bone density on implant stability parameters and implant success: a retrospective clinical study. BMC Oral Health 2008; 8:32.
    • (2008) BMC Oral Health , vol.8 , pp. 32
    • Turkyilmaz, I.1    McGlumphy, E.A.2
  • 16
    • 77953271736 scopus 로고    scopus 로고
    • Bone density at implant sites and its relationship to assessment of bone quality and treatment outcome
    • Bergkvist G, Koh KJ, Sahlholm S, Klintström E, Lindh C. Bone density at implant sites and its relationship to assessment of bone quality and treatment outcome. Int J Oral Maxillofac Implants 2010; 25:321-328.
    • (2010) Int J Oral Maxillofac Implants , vol.25 , pp. 321-328
    • Bergkvist, G.1    Koh, K.J.2    Sahlholm, S.3    Klintström, E.4    Lindh, C.5
  • 17
    • 84864517657 scopus 로고    scopus 로고
    • Short communication: use of a diagnostic software to predict bone density and implant stability in preoperative CTs
    • Pagliani L, Motroni A, Nappo A, Sennerby L. Short communication: use of a diagnostic software to predict bone density and implant stability in preoperative CTs. Clin Implant Dent Relat Res 2012; 14:553-557.
    • (2012) Clin Implant Dent Relat Res , vol.14 , pp. 553-557
    • Pagliani, L.1    Motroni, A.2    Nappo, A.3    Sennerby, L.4
  • 19
    • 84873250429 scopus 로고    scopus 로고
    • The relationship between resonance frequency analysis (RFA) and lateral displacement of dental implants: an in vitro study
    • Pagliani L, Sennerby L, Petersson A, Verrocchi D, Volpe S, Andersson P. The relationship between resonance frequency analysis (RFA) and lateral displacement of dental implants: an in vitro study. J Oral Rehabil 2013; 40:221-227.
    • (2013) J Oral Rehabil , vol.40 , pp. 221-227
    • Pagliani, L.1    Sennerby, L.2    Petersson, A.3    Verrocchi, D.4    Volpe, S.5    Andersson, P.6
  • 20
    • 85018214815 scopus 로고    scopus 로고
    • 20 Jahre Erfahrung mit der Rezonanzfrequenzanalyse
    • Sennerby L. 20 Jahre Erfahrung mit der Rezonanzfrequenzanalyse. Implantologie 2013; 21:21-33.
    • (2013) Implantologie , vol.21 , pp. 21-33
    • Sennerby, L.1
  • 22
    • 0034574211 scopus 로고    scopus 로고
    • Measurements comparing the initial stability of five designs of dental implants: a human cadaver study
    • O'Sullivan D, Sennerby L, Meredith N. Measurements comparing the initial stability of five designs of dental implants: a human cadaver study. Clin Implant Dent Relat Res 2000; 2:85-92.
    • (2000) Clin Implant Dent Relat Res , vol.2 , pp. 85-92
    • O'Sullivan, D.1    Sennerby, L.2    Meredith, N.3
  • 24
    • 4644228515 scopus 로고    scopus 로고
    • Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants
    • O'Sullivan D, Sennerby L, Meredith N. Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants. Clin Oral Implants Res 2004; 15:474-480.
    • (2004) Clin Oral Implants Res , vol.15 , pp. 474-480
    • O'Sullivan, D.1    Sennerby, L.2    Meredith, N.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.