메뉴 건너뛰기




Volumn , Issue , 2001, Pages 125-129

Distributed measurement station for the evaluation of the impact of power electronic equipment on the power quality of electrical distribution network

Author keywords

Distortion; Power Quality; Power System Transient; Signal Analysis; Virtual Instrumentation.; Voltage Measurement

Indexed keywords

ANALOG TO DIGITAL CONVERSION; DISTORTION (WAVES); DOMESTIC APPLIANCES; ELECTRIC POWER SYSTEM MEASUREMENT; ELECTRIC POWER SYSTEMS; ELECTRIC VARIABLES MEASUREMENT; ELECTRONIC EQUIPMENT; LIGHTING; OSCILLATORS (ELECTRONIC); POWER CONTROL; QUALITY CONTROL; SIGNAL ANALYSIS; TELEVISION SYSTEMS; VOLTAGE MEASUREMENT;

EID: 84943239450     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: None     Document Type: Conference Paper
Times cited : (3)

References (15)
  • 3
    • 0033365981 scopus 로고    scopus 로고
    • On-line digital measurements for the quality Analysis of Power Systems under Non-Sinusoidal Conditions
    • Aug
    • G. Bucci, C. Landi, "On-Line Digital Measurements for the Quality Analysis of Power Systems Under Non-Sinusoidal Conditions", IEEE Trans. On. I&M. Vol. 48, n. 6, Aug. 1999
    • (1999) IEEE Trans. On. I&M , vol.48 , Issue.6
    • Bucci, G.1    Landi, C.2
  • 4
    • 0034249607 scopus 로고    scopus 로고
    • A multi-dsp based instrument on a vxi c-size Module for Real-Time Measurements
    • April
    • G. Bucci, C. Landi, "A Multi-DSP Based Instrument on a VXI C-size Module for Real-Time Measurements", IEEE Trans. On I&M, Vol. 49, n. 2, April 2000
    • (2000) IEEE Trans. on i&m , vol.49 , Issue.2
    • Bucci, G.1    Landi, C.2
  • 7
    • 0032043032 scopus 로고    scopus 로고
    • Power measurements on high distorted Signals: Experimental Comparison between Two Alternative Developed Device Solutions
    • G. Bucci, C. De Capua, C. Landi, "Power Measurements on High Distorted Signals: Experimental Comparison Between Two Alternative Developed Device Solutions". Measurement, vol. 23, n. 4, 1998
    • (1998) Measurement , vol.23 , Issue.4
    • Bucci, G.1    De Capua, C.2    Landi, C.3
  • 8
    • 0033315079 scopus 로고    scopus 로고
    • Measurement station performance Optimization for Testing on High Efficiency Variable Speed Drives
    • Dec
    • C. De Capua, C. Landi; "Measurement Station Performance Optimization for Testing on High Efficiency Variable Speed Drives". IEEE Tran. on Instr. and Meas., Vol. 48, N. 6, Dec. 1999
    • (1999) IEEE Tran. on Instr. and Meas , vol.48 , Issue.6
    • De Capua, C.1    Landi, C.2
  • 9
    • 0033707573 scopus 로고    scopus 로고
    • Low-cost vxi-based front-end for distributed measurement applications
    • Baltimora May
    • G. Bucci, C. Landi, "Low-Cost VXI-Based Front-End For Distributed Measurement Applications", Proc. IMTC 2000, Baltimora, May 2000
    • (2000) Proc. IMTC 2000
    • Bucci, G.1    Landi, C.2
  • 12
    • 0032181420 scopus 로고    scopus 로고
    • A virtual instrument for measurement of flicker
    • Oct
    • S. Caldara, S. Nuccio, C. Spataro, "A Virtual Instrument for Measurement of Flicker", IEEE Trans. on I&M, Vol. 47, n. 5, Oct. 1998
    • (1998) IEEE Trans. on i&m , vol.47 , Issue.5
    • Caldara, S.1    Nuccio, S.2    Spataro, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.