메뉴 건너뛰기




Volumn 21, Issue 10, 2015, Pages 785-791

Left ventricular decompression during speed optimization ramps in patients supported by continuous-flow left ventricular assist devices: Device-specific performance characteristics and impact on diagnostic algorithms

Author keywords

LVAD; LVEDD slope; Ramp; unloading

Indexed keywords

ADULT; AGED; ALGORITHM; AORTA VALVE; AORTA VALVE DISEASE; ARTICLE; CONTINUOUS FLOW LEFT VENTRICULAR ASSIST DEVICE; DECOMPRESSION; DIAGNOSTIC ALGORITHM; DIAGNOSTIC TEST; ECHOCARDIOGRAPHIC RAMP TEST; ECHOCARDIOGRAPHY; FEMALE; HEART LEFT VENTRICLE ENDDIASTOLIC PRESSURE; HOSPITAL DISCHARGE; HOSPITALIZATION; HUMAN; LEFT VENTRICULAR DECOMPRESSION; MAJOR CLINICAL STUDY; MALE; PRIORITY JOURNAL; PROSPECTIVE STUDY; VELOCITY; VITAL SIGN; COHORT ANALYSIS; HEART ASSIST DEVICE; HEART FAILURE; HEART LEFT VENTRICLE FUNCTION; MIDDLE AGED; PATHOPHYSIOLOGY; PHYSIOLOGY; STANDARDS; TIME FACTOR;

EID: 84942586344     PISSN: 10719164     EISSN: 15328414     Source Type: Journal    
DOI: 10.1016/j.cardfail.2015.06.010     Document Type: Article
Times cited : (62)

References (19)
  • 2
    • 79952716402 scopus 로고    scopus 로고
    • Echocardiographic predictors of adverse outcomes after continuous left ventricular assist device implantation
    • Y. Topilsky, J.K. Oh, D.K. Shah, B. Boilson, J. Schirger, and S.S. Kushwaha Echocardiographic predictors of adverse outcomes after continuous left ventricular assist device implantation JACC Cardiovasc Imaging 4 2011 211 222
    • (2011) JACC Cardiovasc Imaging , vol.4 , pp. 211-222
    • Topilsky, Y.1    Oh, J.K.2    Shah, D.K.3    Boilson, B.4    Schirger, J.5    Kushwaha, S.S.6
  • 3
    • 84867890273 scopus 로고    scopus 로고
    • Development of a novel echocardiography ramp test for speed optimization and diagnosis of device thrombosis in continuous-flow left ventricular assist devices: The Columbia Ramp Study
    • N. Uriel, K.A. Morrison, A.R. Garan, T.S. Kato, M. Yuzefpolskaya, and F. Latif Development of a novel echocardiography ramp test for speed optimization and diagnosis of device thrombosis in continuous-flow left ventricular assist devices: the Columbia Ramp Study J Am Coll Cardiol 60 2012 1764 1775
    • (2012) J Am Coll Cardiol , vol.60 , pp. 1764-1775
    • Uriel, N.1    Morrison, K.A.2    Garan, A.R.3    Kato, T.S.4    Yuzefpolskaya, M.5    Latif, F.6
  • 4
    • 84886919336 scopus 로고    scopus 로고
    • Loading conditions influence reliability of the echocardiographic ramp test in continuous-flow left ventricular assist devices
    • S. Adatya, C. Masri, R. John, and P. Eckman Loading conditions influence reliability of the echocardiographic ramp test in continuous-flow left ventricular assist devices J Heart Lung Transplant 32 2013 1142 1144
    • (2013) J Heart Lung Transplant , vol.32 , pp. 1142-1144
    • Adatya, S.1    Masri, C.2    John, R.3    Eckman, P.4
  • 5
    • 84863195802 scopus 로고    scopus 로고
    • Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation
    • K.D. Aaronson, M.S. Slaughter, L.W. Miller, E.C. McGee, W.G. Cotts, M.A. Acker, and et al. Use of an intrapericardial, continuous-flow, centrifugal pump in patients awaiting heart transplantation Circulation 125 2012 3191 3200
    • (2012) Circulation , vol.125 , pp. 3191-3200
    • Aaronson, K.D.1    Slaughter, M.S.2    Miller, L.W.3    McGee, E.C.4    Cotts, W.G.5    Acker, M.A.6
  • 7
    • 84879239446 scopus 로고    scopus 로고
    • Pulsatility and the risk of nonsurgical bleeding in patients supported with the continuous-flow left ventricular assist device Heartmate II
    • O. Wever-Pinzon, C.H. Selzman, S.G. Drakos, A. Saidi, G.J. Stoddard, and E.M. Gilbert Pulsatility and the risk of nonsurgical bleeding in patients supported with the continuous-flow left ventricular assist device Heartmate II Circ Heart Fail 6 2013 517 526
    • (2013) Circ Heart Fail , vol.6 , pp. 517-526
    • Wever-Pinzon, O.1    Selzman, C.H.2    Drakos, S.G.3    Saidi, A.4    Stoddard, G.J.5    Gilbert, E.M.6
  • 8
    • 84900004511 scopus 로고    scopus 로고
    • Prevalence, significance, and management of aortic insufficiency in continuous flow left ventricular assist device recipients
    • U.P. Jorde, N. Uriel, N. Nahumi, D. Bejar, J. Gonzalez-Costello, and S.S. Thomas Prevalence, significance, and management of aortic insufficiency in continuous flow left ventricular assist device recipients Circ Heart Fail 7 2014 310 319
    • (2014) Circ Heart Fail , vol.7 , pp. 310-319
    • Jorde, U.P.1    Uriel, N.2    Nahumi, N.3    Bejar, D.4    Gonzalez-Costello, J.5    Thomas, S.S.6
  • 9
    • 77957234680 scopus 로고    scopus 로고
    • Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices
    • S.W. Pak, N. Uriel, H. Takayama, S. Cappleman, R. Song, and P.C. Colombo Prevalence of de novo aortic insufficiency during long-term support with left ventricular assist devices J Heart Lung Transplant 29 2010 1172 1176
    • (2010) J Heart Lung Transplant , vol.29 , pp. 1172-1176
    • Pak, S.W.1    Uriel, N.2    Takayama, H.3    Cappleman, S.4    Song, R.5    Colombo, P.C.6
  • 10
    • 0022673130 scopus 로고
    • Longitudinal data analysis for discrete and continuous outcomes
    • S.L. Zeger, and K.Y. Liang Longitudinal data analysis for discrete and continuous outcomes Biometrics 42 1986 121 130
    • (1986) Biometrics , vol.42 , pp. 121-130
    • Zeger, S.L.1    Liang, K.Y.2
  • 11
    • 84891833672 scopus 로고    scopus 로고
    • Value of serial echo-guided ramp studies in a patient with suspicion of device thrombosis after left ventricular assist device implantation
    • T.S. Kato, P.C. Colombo, N. Nahumi, S. Kitada, H. Takayama, and Y. Naka Value of serial echo-guided ramp studies in a patient with suspicion of device thrombosis after left ventricular assist device implantation Echocardiography 31 2014 E5 E9
    • (2014) Echocardiography , vol.31 , pp. E5-E9
    • Kato, T.S.1    Colombo, P.C.2    Nahumi, N.3    Kitada, S.4    Takayama, H.5    Naka, Y.6
  • 12
    • 84888316207 scopus 로고    scopus 로고
    • Slope calculation for the LVAD ramp test
    • N. Nahumi, U. Jorde, and N. Uriel Slope calculation for the LVAD ramp test J Am Coll Cardiol 62 2013 2149 2150
    • (2013) J Am Coll Cardiol , vol.62 , pp. 2149-2150
    • Nahumi, N.1    Jorde, U.2    Uriel, N.3
  • 14
    • 84926408204 scopus 로고    scopus 로고
    • Echocardiographic ramp test for continuous-flow left ventricular assist devices: Do loading conditions matter?
    • S. Adatya, C.T. Holley, and S.S. Roy Echocardiographic ramp test for continuous-flow left ventricular assist devices: do loading conditions matter? JACC Heart Fail 3 2015 291 299
    • (2015) JACC Heart Fail , vol.3 , pp. 291-299
    • Adatya, S.1    Holley, C.T.2    Roy, S.S.3
  • 15
    • 84879665622 scopus 로고    scopus 로고
    • Heartware ventricular assist system for bridge to transplant: Combined results of the bridge to transplant and continued access protocol trial
    • M.S. Slaughter, F.D. Pagani, E.C. McGee, E.J. Birks, W.G. Cotts, I. Gregoric, and et al. Heartware ventricular assist system for bridge to transplant: combined results of the bridge to transplant and continued access protocol trial J Heart Lung Transplant 32 2013 675 683
    • (2013) J Heart Lung Transplant , vol.32 , pp. 675-683
    • Slaughter, M.S.1    Pagani, F.D.2    McGee, E.C.3    Birks, E.J.4    Cotts, W.G.5    Gregoric, I.6
  • 17
    • 84892177900 scopus 로고    scopus 로고
    • Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the Heartmate II left ventricular assist device
    • J.K. Kirklin, D.C. Naftel, R.L. Kormos, F.D. Pagani, S.L. Myers, and L.W. Stevenson Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the Heartmate II left ventricular assist device J Heart Lung Transplant 33 2014 12 22
    • (2014) J Heart Lung Transplant , vol.33 , pp. 12-22
    • Kirklin, J.K.1    Naftel, D.C.2    Kormos, R.L.3    Pagani, F.D.4    Myers, S.L.5    Stevenson, L.W.6
  • 18
    • 84892141967 scopus 로고    scopus 로고
    • An analysis of pump thrombus events in patients in the Heartware ADVANCE bridge to transplant and continued access protocol trial
    • S.S. Najjar, M.S. Slaughter, F.D. Pagani, R.C. Starling, E.C. McGee, and P. Eckman An analysis of pump thrombus events in patients in the Heartware ADVANCE bridge to transplant and continued access protocol trial J Heart Lung Transplant 33 2014 23 34
    • (2014) J Heart Lung Transplant , vol.33 , pp. 23-34
    • Najjar, S.S.1    Slaughter, M.S.2    Pagani, F.D.3    Starling, R.C.4    McGee, E.C.5    Eckman, P.6
  • 19
    • 84901287457 scopus 로고    scopus 로고
    • A simplified echocardiographic technique for detecting continuous-flow left ventricular assist device malfunction due to pump thrombosis
    • J.D. Estep, R.P. Vivo, A.M. Cordero-Reyes, A. Bhimaraj, B.H. Trachtenberg, and G. Torre-Amione A simplified echocardiographic technique for detecting continuous-flow left ventricular assist device malfunction due to pump thrombosis J Heart Lung Transplant 33 2014 575 586
    • (2014) J Heart Lung Transplant , vol.33 , pp. 575-586
    • Estep, J.D.1    Vivo, R.P.2    Cordero-Reyes, A.M.3    Bhimaraj, A.4    Trachtenberg, B.H.5    Torre-Amione, G.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.