메뉴 건너뛰기




Volumn 1, Issue 3, 2015, Pages 161-163

Ablation for persistent atrial fibrillation: Pulmonary vein isolation plus what?

Author keywords

atrial fibrillation; catheter ablation; left atrial appendage; ligation

Indexed keywords

ANTICOAGULANT THERAPY; BLOOD CLOTTING; CATHETER ABLATION; COMPUTER ASSISTED TOMOGRAPHY; HEART ATRIUM APPENDAGE; HEART ELECTROPHYSIOLOGY; HEART SURGERY; HUMAN; NOTE; PERICARDIAL EFFUSION; PERSISTENT ATRIAL FIBRILLATION; PRIORITY JOURNAL; PULMONARY VEIN ISOLATION; RADIOFREQUENCY ABLATION; SUTURE DELIVERY DEVICE;

EID: 84942114002     PISSN: 2405500X     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.jacep.2015.04.008     Document Type: Editorial
Times cited : (1)

References (18)
  • 1
    • 0037022841 scopus 로고    scopus 로고
    • Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation
    • H. Oral, B.P. Knight, H. Tada, and et al. Pulmonary vein isolation for paroxysmal and persistent atrial fibrillation Circulation 105 2002 1077 1081
    • (2002) Circulation , vol.105 , pp. 1077-1081
    • Oral, H.1    Knight, B.P.2    Tada, H.3
  • 2
    • 67651183609 scopus 로고    scopus 로고
    • Approaches to ablation of persistent atrial fibrillation
    • M.P. Smelley, and B.P. Knight Approaches to ablation of persistent atrial fibrillation Heart Rhythm J 6 Suppl 2009 S33 S38
    • (2009) Heart Rhythm J , vol.6 , pp. S33-S38
    • Smelley, M.P.1    Knight, B.P.2
  • 3
    • 33644792337 scopus 로고    scopus 로고
    • Catheter ablation of long-lasting persistent atrial fibrillation: Critical structures for termination
    • M. Haissaguerre, P. Sanders, M. Hocini, and et al. Catheter ablation of long-lasting persistent atrial fibrillation: critical structures for termination J Cardiovasc Electrophysiol 16 2005 1125 1137
    • (2005) J Cardiovasc Electrophysiol , vol.16 , pp. 1125-1137
    • Haissaguerre, M.1    Sanders, P.2    Hocini, M.3
  • 4
    • 84928975016 scopus 로고    scopus 로고
    • Approaches to catheter ablation for persistent atrial fibrillation
    • A. Verma, C. Jiang, T.R. Betts, and et al. Approaches to catheter ablation for persistent atrial fibrillation N Engl J Med 372 2015 1812 1822
    • (2015) N Engl J Med , vol.372 , pp. 1812-1822
    • Verma, A.1    Jiang, C.2    Betts, T.R.3
  • 5
    • 84932182197 scopus 로고    scopus 로고
    • Five-year follow-up after catheter ablation of persistent atrial fibrillation using the "stepwise approach" and prognostic factors for success
    • D. Schreiber, T. Rostock, M. Frohlich, and et al. Five-year follow-up after catheter ablation of persistent atrial fibrillation using the "stepwise approach" and prognostic factors for success Circ Arrhythm Electrophysiol 8 2015 308 317
    • (2015) Circ Arrhythm Electrophysiol , vol.8 , pp. 308-317
    • Schreiber, D.1    Rostock, T.2    Frohlich, M.3
  • 6
    • 84899635276 scopus 로고    scopus 로고
    • Ablation of rotor and focal sources reduces late recurrence of atrial fibrillation compared with trigger ablation alone: Extended follow-up of the CONFIRM trial (Conventional Ablation for Atrial Fibrillation with or Without Focal Impulse and Rotor Modulation)
    • S.M. Narayan, T. Baykaner, P. Clopton, and et al. Ablation of rotor and focal sources reduces late recurrence of atrial fibrillation compared with trigger ablation alone: extended follow-up of the CONFIRM trial (Conventional Ablation for Atrial Fibrillation With or Without Focal Impulse and Rotor Modulation) J Am Coll Cardiol 63 2014 1761 1768
    • (2014) J Am Coll Cardiol , vol.63 , pp. 1761-1768
    • Narayan, S.M.1    Baykaner, T.2    Clopton, P.3
  • 7
    • 84878573448 scopus 로고    scopus 로고
    • Noninvasive panoramic mapping of human atrial fibrillation mechanisms: A feasibility report
    • M. Haissaguerre, M. Hocini, A.J. Shah, and et al. Noninvasive panoramic mapping of human atrial fibrillation mechanisms: a feasibility report J Cardiovasc Electrophysiol 24 2013 711 717
    • (2013) J Cardiovasc Electrophysiol , vol.24 , pp. 711-717
    • Haissaguerre, M.1    Hocini, M.2    Shah, A.J.3
  • 8
    • 75749148830 scopus 로고    scopus 로고
    • Magnetic resonance imaging-confirmed ablative debulking of the left atrial posterior wall and septum for treatment of persistent atrial fibrillation: Rationale and initial experience
    • N.M. Segerson, M. Daccarett, T.J. Badger, and et al. Magnetic resonance imaging-confirmed ablative debulking of the left atrial posterior wall and septum for treatment of persistent atrial fibrillation: rationale and initial experience J Cardiovasc Electrophysiol 21 2010 126 132
    • (2010) J Cardiovasc Electrophysiol , vol.21 , pp. 126-132
    • Segerson, N.M.1    Daccarett, M.2    Badger, T.J.3
  • 9
    • 70349387790 scopus 로고    scopus 로고
    • Ablation of persistent atrial fibrillation using multielectrode catheters and duty-cycled radiofrequency energy
    • C. Scharf, L. Boersma, W. Davies, and et al. Ablation of persistent atrial fibrillation using multielectrode catheters and duty-cycled radiofrequency energy J Am Coll Cardiol 54 2009 1450 1456
    • (2009) J Am Coll Cardiol , vol.54 , pp. 1450-1456
    • Scharf, C.1    Boersma, L.2    Davies, W.3
  • 10
    • 79957727183 scopus 로고    scopus 로고
    • Initial experience of sequential surgical epicardial-catheter endocardial ablation for persistent and long-standing persistent atrial fibrillation with long-term follow-up
    • S. Mahapatra, D.J. LaPar, S. Kamath, and et al. Initial experience of sequential surgical epicardial-catheter endocardial ablation for persistent and long-standing persistent atrial fibrillation with long-term follow-up Ann Thorac Surg 91 2011 1890 1898
    • (2011) Ann Thorac Surg , vol.91 , pp. 1890-1898
    • Mahapatra, S.1    LaPar, D.J.2    Kamath, S.3
  • 11
    • 77955899530 scopus 로고    scopus 로고
    • Catheter-based left atrial appendage (LAA) ligation for the prevention of embolic events arising from the LAA: Initial experience in a canine model
    • R.J. Lee, K. Bartus, and S.J. Yakubov Catheter-based left atrial appendage (LAA) ligation for the prevention of embolic events arising from the LAA: initial experience in a canine model Circ Cardiovasc Interv 3 2010 224 229
    • (2010) Circ Cardiovasc Interv , vol.3 , pp. 224-229
    • Lee, R.J.1    Bartus, K.2    Yakubov, S.J.3
  • 12
    • 84898982598 scopus 로고    scopus 로고
    • The effects of LAA ligation on LAA electrical activity
    • F.T. Han, K. Bartus, D. Lakkireddy, and et al. The effects of LAA ligation on LAA electrical activity Heart Rhythm 11 2014 864 870
    • (2014) Heart Rhythm , vol.11 , pp. 864-870
    • Han, F.T.1    Bartus, K.2    Lakkireddy, D.3
  • 13
    • 84920640565 scopus 로고    scopus 로고
    • Impact of left atrial appendage exclusion using an epicardial ligation system (LARIAT) on atrial fibrillation burden in patients with cardiac implantable electronic devices
    • M.R. Afzal, A. Kanmanthareddy, M. Earnest, and et al. Impact of left atrial appendage exclusion using an epicardial ligation system (LARIAT) on atrial fibrillation burden in patients with cardiac implantable electronic devices Heart Rhythm J 12 2015 52 59
    • (2015) Heart Rhythm J , vol.12 , pp. 52-59
    • Afzal, M.R.1    Kanmanthareddy, A.2    Earnest, M.3
  • 14
    • 84939650599 scopus 로고    scopus 로고
    • Left atrial appendage ligation and ablation for persistent atrial fibrillation: The LAALA-AF registry
    • D. Lakkireddy, A.S. Mahankali, A. Kanmanthareddy, and et al. Left atrial appendage ligation and ablation for persistent atrial fibrillation: the LAALA-AF registry J Am Coll Cardiol EP 1 2015 153 160
    • (2015) J Am Coll Cardiol EP , vol.1 , pp. 153-160
    • Lakkireddy, D.1    Mahankali, A.S.2    Kanmanthareddy, A.3
  • 15
    • 84905701209 scopus 로고    scopus 로고
    • Early safety and efficacy of percutaneous left atrial appendage suture ligation: Results from the U.S. Transcatheter LAA ligation consortium
    • M.J. Price, D.N. Gibson, S.J. Yakubov, and et al. Early safety and efficacy of percutaneous left atrial appendage suture ligation: results from the U.S. Transcatheter LAA ligation consortium J Am Coll Cardiol 64 2014 565 572
    • (2014) J Am Coll Cardiol , vol.64 , pp. 565-572
    • Price, M.J.1    Gibson, D.N.2    Yakubov, S.J.3
  • 16
    • 84921692937 scopus 로고    scopus 로고
    • Differences in experience with a new delivery device for LAA ligation among various U.S. Centers
    • (letter)
    • A. Rasekh, S. Kar, H. Nagaraj, and et al. Differences in experience with a new delivery device for LAA ligation among various U.S. centers (letter) J Am Coll Cardiol 65 2015 404 405
    • (2015) J Am Coll Cardiol , vol.65 , pp. 404-405
    • Rasekh, A.1    Kar, S.2    Nagaraj, H.3
  • 17
    • 84921683996 scopus 로고    scopus 로고
    • Reply: Differences in experience with a new delivery device for LAA ligation among various U.S. Centers
    • (letter)
    • M.J. Price, and M. Valderrábano Reply: differences in experience with a new delivery device for LAA ligation among various U.S. centers (letter) J Am Coll Cardiol 65 2015 405 406
    • (2015) J Am Coll Cardiol , vol.65 , pp. 405-406
    • Price, M.J.1    Valderrábano, M.2
  • 18
    • 84939796802 scopus 로고    scopus 로고
    • Quantitative analysis of localized sources identified by focal impulse and rotor modulation mapping in atrial fibrillation
    • [E-pub ahead of print]
    • P. Benharash, E. Buch, P. Frank, and et al. Quantitative analysis of localized sources identified by focal impulse and rotor modulation mapping in atrial fibrillation Circ Arrhythm Electrophysiol 2015 Apr 14 [E-pub ahead of print]
    • (2015) Circ Arrhythm Electrophysiol
    • Benharash, P.1    Buch, E.2    Frank, P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.