메뉴 건너뛰기




Volumn 10, Issue 9, 2015, Pages 1371-1381

A multi-vertebrae CT to US registration of the lumbar spine in clinical data

Author keywords

Lumbar spine; Multi vertebrae; Registration; Spinal interventions; Ultrasound

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; CLINICAL ARTICLE; CLINICAL STUDY; COMPUTER ASSISTED TOMOGRAPHY; EPIDURAL DRUG ADMINISTRATION; FEMALE; HUMAN; IMAGE QUALITY; INFORMATION PROCESSING; LUMBAR VERTEBRA; MALE; ORTHODONTIC SPRING; PATHOLOGICAL ANATOMY; PRIORITY JOURNAL; RADIATION HAZARD; REAL TIME ULTRASOUND SCANNER; SPINAL NEEDLE; ULTRASOUND; ULTRASOUND TRANSDUCER; ALGORITHM; DEVICES; ECHOGRAPHY; EQUIPMENT DESIGN; IMAGE PROCESSING; INTRASPINAL DRUG ADMINISTRATION; IONIZING RADIATION; MIDDLE AGED; MULTIMODAL IMAGING; NEEDLE; PROCEDURES; RADIOGRAPHY; REPRODUCIBILITY; STATISTICAL MODEL; VERY ELDERLY;

EID: 84941335952     PISSN: 18616410     EISSN: 18616429     Source Type: Journal    
DOI: 10.1007/s11548-015-1247-5     Document Type: Article
Times cited : (29)

References (23)
  • 1
    • 66349122938 scopus 로고    scopus 로고
    • Ultrasound imaging of the lumbar spine in the transverse plane: the correlation between estimated and actual depth to the epidural space in obese parturients
    • PID: 19448216
    • Balki M, Lee Y, Halpern S, Carvalho J (2009) Ultrasound imaging of the lumbar spine in the transverse plane: the correlation between estimated and actual depth to the epidural space in obese parturients. Anesth Analg 108(6):1876–1881
    • (2009) Anesth Analg , vol.108 , Issue.6 , pp. 1876-1881
    • Balki, M.1    Lee, Y.2    Halpern, S.3    Carvalho, J.4
  • 2
    • 84873345113 scopus 로고    scopus 로고
    • Real-time ultrasound-guided spinal anaesthesia: a prospective observational study of a new approach
    • COI: 1:STN:280:DC%2BC3szktVSisA%3D%3D
    • Conroy P, Luyet C, McCartney C, McHardy P (2013) Real-time ultrasound-guided spinal anaesthesia: a prospective observational study of a new approach. Anesthesiol Res Pract 2013:525 818–525 824
    • (2013) Anesthesiol Res Pract , vol.2013 , pp. 818-824
    • Conroy, P.1    Luyet, C.2    McCartney, C.3    McHardy, P.4
  • 7
    • 84897571669 scopus 로고    scopus 로고
    • Statistical shape model to 3D ultrasound registration for spine interventions using enhanced local phase features. In: Medical image computing and computer-assisted intervention-MICCAI
    • Hacihaliloglu I, Rasoulian A, Rohling R, Abolmaesumi P (2013) Statistical shape model to 3D ultrasound registration for spine interventions using enhanced local phase features. In: Medical image computing and computer-assisted intervention-MICCAI, pp 361–368
    • (2013) pp 361–368
    • Hacihaliloglu, I.1    Rasoulian, A.2    Rohling, R.3    Abolmaesumi, P.4
  • 8
    • 0032173371 scopus 로고    scopus 로고
    • Surface-based registration of CT images to physical space for image-guided surgery of the spine: a sensitivity study
    • COI: 1:STN:280:DyaK1M%2FovFKqtg%3D%3D, PID: 9874298
    • Herring J, Dawant B, Maurer C, Muratore D, Galloway R Jr, Fitzpatrick J (1998) Surface-based registration of CT images to physical space for image-guided surgery of the spine: a sensitivity study. IEEE Trans Med Imaging 17(5):743–752
    • (1998) IEEE Trans Med Imaging , vol.17 , Issue.5 , pp. 743-752
    • Herring, J.1    Dawant, B.2    Maurer, C.3    Muratore, D.4    Galloway, R.5    Fitzpatrick, J.6
  • 9
    • 77957937325 scopus 로고    scopus 로고
    • Brainsfit: mutual information registrations of whole-brain 3D images, using the insight toolkit
    • Johnson H, Harris G, Williams K (2007) Brainsfit: mutual information registrations of whole-brain 3D images, using the insight toolkit. Insight J
    • (2007) Insight J
    • Johnson, H.1    Harris, G.2    Williams, K.3
  • 12
    • 0038371263 scopus 로고    scopus 로고
    • Three-dimensional image registration of phantom vertebrae for image-guided surgery: a preliminary study
    • PID: 12731097
    • Muratore DM, Russ JH, Dawant BM, Galloway R Jr (2002) Three-dimensional image registration of phantom vertebrae for image-guided surgery: a preliminary study. Comput Aided Surg 7(6):342–352
    • (2002) Comput Aided Surg , vol.7 , Issue.6 , pp. 342-352
    • Muratore, D.M.1    Russ, J.H.2    Dawant, B.M.3    Galloway, R.4
  • 13
    • 78049528457 scopus 로고    scopus 로고
    • Point set registration: coherent point drift
    • Myronenko A, Song X (2010) Point set registration: coherent point drift. IEEE Trans Pattern Anal Mach Intell 32(12):2262–2275
    • (2010) IEEE Trans Pattern Anal Mach Intell , vol.32 , Issue.12 , pp. 2262-2275
    • Myronenko, A.1    Song, X.2
  • 16
    • 33750933707 scopus 로고    scopus 로고
    • The NA-MIC kit: Itk, vtk, pipelines, grids and 3D slicer as an open platform for the medical image computing community
    • Pieper S, Lorensen B, Schroeder W, Kikinis R (2006) The NA-MIC kit: Itk, vtk, pipelines, grids and 3D slicer as an open platform for the medical image computing community. In: IEEE symposium on biomedical imaging: nano to macro 2006, pp 698–701
    • (2006) IEEE symposium on biomedical imaging: nano to macro , vol.2006 , pp. 698-701
    • Pieper, S.1    Lorensen, B.2    Schroeder, W.3    Kikinis, R.4
  • 17
    • 70449331460 scopus 로고    scopus 로고
    • Local-phase based 3D boundary detection using monogenic signal and its application to real-time 3D echocardiography images
    • Rajpoot K, Grau V, Noble JA (2009) Local-phase based 3D boundary detection using monogenic signal and its application to real-time 3D echocardiography images. In: IEEE symposium on biomedical imaging: from nano to macro 2009, pp 783–786
    • (2009) IEEE symposium on biomedical imaging: from nano to macro , vol.2009 , pp. 783-786
    • Rajpoot, K.1    Grau, V.2    Noble, J.A.3
  • 18
    • 84860255216 scopus 로고    scopus 로고
    • Probabilistic registration of an unbiased statistical shape model to ultrasound images of the spine. In: proceedings of SPIE medical imaging, Orlando, Florida, USA
    • Rasoulian A, Rohling R, Abolmaesumi P (2012) Probabilistic registration of an unbiased statistical shape model to ultrasound images of the spine. In: proceedings of SPIE medical imaging, Orlando, Florida, USA, pp 8316:83161P-1-83161P-6
    • (2012) pp 8316:83161P-1-83161P-6
    • Rasoulian, A.1    Rohling, R.2    Abolmaesumi, P.3
  • 19
    • 84863526398 scopus 로고    scopus 로고
    • Feature-based multibody rigid registration of CT and ultrasound images of lumbar spine
    • PID: 22755700
    • Rasoulian A, Abolmaesumi P, Mousavi P (2012) Feature-based multibody rigid registration of CT and ultrasound images of lumbar spine. Med Phys 39(6):3154–3166
    • (2012) Med Phys , vol.39 , Issue.6 , pp. 3154-3166
    • Rasoulian, A.1    Abolmaesumi, P.2    Mousavi, P.3
  • 20
    • 84885136637 scopus 로고    scopus 로고
    • Lumbar spine segmentation using a statistical multi-vertebrae anatomical shape+pose model
    • PID: 23771318
    • Rasoulian A, Rohling R, Abolmaesumi P (2013) Lumbar spine segmentation using a statistical multi-vertebrae anatomical shape+pose model. IEEE Trans Med Imaging 32(10):1890–1900
    • (2013) IEEE Trans Med Imaging , vol.32 , Issue.10 , pp. 1890-1900
    • Rasoulian, A.1    Rohling, R.2    Abolmaesumi, P.3
  • 22
    • 62149104110 scopus 로고    scopus 로고
    • Registration of CT and intraoperative 3D ultrasound images of the spine using evolutionary and gradient-based methods
    • Winter S, Brendel B, Pechlivanis I, Schmieder K, Igel C (2008) Registration of CT and intraoperative 3D ultrasound images of the spine using evolutionary and gradient-based methods. IEEE Trans Evolut Comput 12(3):284–296
    • (2008) IEEE Trans Evolut Comput , vol.12 , Issue.3 , pp. 284-296
    • Winter, S.1    Brendel, B.2    Pechlivanis, I.3    Schmieder, K.4    Igel, C.5
  • 23


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.