Volumn 39, Issue 9, 2015, Pages 1689-1693

High incidence of stem loosening in association with periprosthetic femur fractures in previously well-fixed cementless grit-blasted tapered-wedge stems

Author keywords

Cementless grit blasted tapered wedge stem; Loosening; Periprosthetic femur fractures; Total hip arthroplasty

Indexed keywords

TITANIUM; BIOMATERIAL;

EID: 84940461015     PISSN: 03412695     EISSN: 14325195     Source Type: Journal    
DOI: 10.1007/s00264-014-2586-5     Document Type: Article
Times cited : (9)

References (24)
  • 1
    • 0035134757 scopus 로고    scopus 로고
    • Grit-blasted titanium femoral stem in cementless primary total hip arthroplasty: a 5- to 10-year multicenter study
    • COI: 1:STN:280:DC%2BD3M7lsFWrtw%3D%3D
    • Delaunay C, Bonnomet F, North J, Jobard D, Cazeau C, Kempf JF (2001) Grit-blasted titanium femoral stem in cementless primary total hip arthroplasty: a 5- to 10-year multicenter study. J Arthroplast 16(1):47–54
    • (2001) J Arthroplast , vol.16 , Issue.1 , pp. 47-54
    • Delaunay, C.1    Bonnomet, F.2    North, J.3    Jobard, D.4    Cazeau, C.5    Kempf, J.F.6
  • 2
    • 67649890820 scopus 로고    scopus 로고
    • Uncemented grit-blasted straight tapered titanium stems in patients younger than fifty-five years of age. Fifteen to twenty-year results
    • PID: 19487522
    • Aldinger PR, Jung AW, Pritsch M et al (2009) Uncemented grit-blasted straight tapered titanium stems in patients younger than fifty-five years of age. Fifteen to twenty-year results. J Bone Joint Surg Am 91(6):1432–1439
    • (2009) J Bone Joint Surg Am , vol.91 , Issue.6 , pp. 1432-1439
    • Aldinger, P.R.1    Jung, A.W.2    Pritsch, M.3
  • 3
    • 84878635941 scopus 로고    scopus 로고
    • Pooled outcome of total hip arthroplasty with the CementLess Spotorno (CLS) system: a comparative analysis of clinical studies and worldwide arthroplasty register data
    • PID: 23525550
    • Sadoghi P, Janda W, Agreiter M, Rauf R, Leithner A, Labek G (2013) Pooled outcome of total hip arthroplasty with the CementLess Spotorno (CLS) system: a comparative analysis of clinical studies and worldwide arthroplasty register data. Int Orthop 37(6):995–999
    • (2013) Int Orthop , vol.37 , Issue.6 , pp. 995-999
    • Sadoghi, P.1    Janda, W.2    Agreiter, M.3    Rauf, R.4    Leithner, A.5    Labek, G.6
  • 4
    • 0037629037 scopus 로고    scopus 로고
    • Periprosthetic fractures associated with osteolysis: a problem on the rise
    • PID: 12730943
    • Berry DJ (2003) Periprosthetic fractures associated with osteolysis: a problem on the rise. J Arthroplasty 18(3 Suppl 1):107–111
    • (2003) J Arthroplasty , vol.18 , pp. 107-111
    • Berry, D.J.1
  • 5
    • 26844563975 scopus 로고    scopus 로고
    • Periprosthetic femoral fractures classification and demographics of 1049 periprosthetic femoral fractures from the swedish national Hip arthroplasty register
    • Lindahl H, Malchau H, Herberts P, Garellick G (2005) Periprosthetic femoral fractures classification and demographics of 1049 periprosthetic femoral fractures from the swedish national Hip arthroplasty register. J Arthoplast 20(7):857–865
    • (2005) J Arthoplast , vol.20 , Issue.7 , pp. 857-865
    • Lindahl, H.1    Malchau, H.2    Herberts, P.3    Garellick, G.4
  • 7
    • 78651244598 scopus 로고    scopus 로고
    • The risk of peri-prosthetic fracture after primary and revision total hip and knee replacement
    • COI: 1:STN:280:DC%2BC3M%2FotVGhuw%3D%3D, PID: 21196551
    • Meek RM, Norwood T, Smith R, Brenkel IJ, Howie CR (2011) The risk of peri-prosthetic fracture after primary and revision total hip and knee replacement. J Bone Joint Surg Br 93(1):96–101
    • (2011) J Bone Joint Surg Br , vol.93 , Issue.1 , pp. 96-101
    • Meek, R.M.1    Norwood, T.2    Smith, R.3    Brenkel, I.J.4    Howie, C.R.5
  • 8
    • 79551611710 scopus 로고    scopus 로고
    • Late peri-prosthetic femoral fracture as a major mode of failure in uncemented primary hip replacement
    • COI: 1:STN:280:DC%2BC3M7lsl2rtQ%3D%3D, PID: 21282755
    • Streit MR, Merle C, Clarius M, Aldinger PR (2011) Late peri-prosthetic femoral fracture as a major mode of failure in uncemented primary hip replacement. J Bone Joint Surg Br 93(2):178–183
    • (2011) J Bone Joint Surg Br , vol.93 , Issue.2 , pp. 178-183
    • Streit, M.R.1    Merle, C.2    Clarius, M.3    Aldinger, P.R.4
  • 9
    • 31144454517 scopus 로고    scopus 로고
    • Risk factors for failure after treatment of a periprosthetic fracture of the femur
    • COI: 1:STN:280:DC%2BD2MnnslejsQ%3D%3D, PID: 16365115
    • Lindahl H, Malchau H, Odén A, Garellick G (2006) Risk factors for failure after treatment of a periprosthetic fracture of the femur. J Bone Joint Surg Br 88(1):26–30
    • (2006) J Bone Joint Surg Br , vol.88 , Issue.1 , pp. 26-30
    • Lindahl, H.1    Malchau, H.2    Odén, A.3    Garellick, G.4
  • 11
    • 84898923275 scopus 로고    scopus 로고
    • Extracortical plate fixation with new plate inserts and cerclage wires for the treatment of periprosthetic hip fractures
    • PID: 24091416
    • Bastian JD, Butscher A, Bigolin G, Zumstein MA, Nötzli HP (2014) Extracortical plate fixation with new plate inserts and cerclage wires for the treatment of periprosthetic hip fractures. Int Orthop 38(3):489–494
    • (2014) Int Orthop , vol.38 , Issue.3 , pp. 489-494
    • Bastian, J.D.1    Butscher, A.2    Bigolin, G.3    Zumstein, M.A.4    Nötzli, H.P.5
  • 12
    • 0029187931 scopus 로고
    • Fractures of the femur after hip replacement
    • COI: 1:STN:280:DyaK2MzhvVCktA%3D%3D, PID: 7797866
    • Duncan CP, Masri BA (1995) Fractures of the femur after hip replacement. Instr Course Lect 44:293–304
    • (1995) Instr Course Lect , vol.44 , pp. 293-304
    • Duncan, C.P.1    Masri, B.A.2
  • 13
    • 1642504433 scopus 로고    scopus 로고
    • The management of periprosthetic fractures around the femoral stem
    • COI: 1:STN:280:DC%2BD2c%2FmsVOisg%3D%3D, PID: 14765858
    • Learmonth ID (2004) The management of periprosthetic fractures around the femoral stem. J Bone Joint Surg Br 86(1):13–19
    • (2004) J Bone Joint Surg Br , vol.86 , Issue.1 , pp. 13-19
    • Learmonth, I.D.1
  • 14
    • 70350634217 scopus 로고    scopus 로고
    • An algorithm for the surgical treatment of periprosthetic fractures of the femur around a well-fixed femoral component
    • COI: 1:STN:280:DC%2BD1MjjtFajtw%3D%3D, PID: 19880884
    • Corten K, Vanrykel F, Bellemans J, Frederix PR, Simon JP, Broos PL (2009) An algorithm for the surgical treatment of periprosthetic fractures of the femur around a well-fixed femoral component. J Bone Joint Surg Br 91(11):1424–1430
    • (2009) J Bone Joint Surg Br , vol.91 , Issue.11 , pp. 1424-1430
    • Corten, K.1    Vanrykel, F.2    Bellemans, J.3    Frederix, P.R.4    Simon, J.P.5    Broos, P.L.6
  • 15
    • 77950917533 scopus 로고    scopus 로고
    • Management of late periprosthetic femur fractures: a retrospective cohort of 72 patients
    • PID: 19513712
    • Mukundan C, Rayan F, Kheir E, Macdonald D (2010) Management of late periprosthetic femur fractures: a retrospective cohort of 72 patients. Int Orthop 34(4):485–489
    • (2010) Int Orthop , vol.34 , Issue.4 , pp. 485-489
    • Mukundan, C.1    Rayan, F.2    Kheir, E.3    Macdonald, D.4
  • 16
    • 84863775685 scopus 로고    scopus 로고
    • Dorn U (2012) Management of Vancouver B2 and B3 femoral periprosthetic fractures using a modular cementless stem without allografting
    • PID: 21983940
    • Neumann D, Thaler C (2012) Dorn U (2012) Management of Vancouver B2 and B3 femoral periprosthetic fractures using a modular cementless stem without allografting. Int Orthop 36(5):1045–1050
    • (2012) Int Orthop , vol.36 , Issue.5 , pp. 1045-1050
    • Neumann, D.1    Thaler, C.2
  • 18
    • 0027230459 scopus 로고
    • Structural and cellular assessment of bone quality of proximal femur
    • COI: 1:STN:280:DyaK3szntFyltQ%3D%3D, PID: 8363862
    • Dorr LD, Faugere MC, Mackel AM, Gruen TA, Bognar B, Malluche HH (1993) Structural and cellular assessment of bone quality of proximal femur. Bone 14(3):231–242
    • (1993) Bone , vol.14 , Issue.3 , pp. 231-242
    • Dorr, L.D.1    Faugere, M.C.2    Mackel, A.M.3    Gruen, T.A.4    Bognar, B.5    Malluche, H.H.6
  • 19
    • 40849139523 scopus 로고    scopus 로고
    • The effect of stem alignment on results of total hip arthroplasty with a cementless tapered-wedge femoral component
    • PID: 18358382
    • Min BW, Song KS, Bae KC, Cho CH, Kang CH, Kim SY (2008) The effect of stem alignment on results of total hip arthroplasty with a cementless tapered-wedge femoral component. J Arthroplasty 23(3):418–423
    • (2008) J Arthroplasty , vol.23 , Issue.3 , pp. 418-423
    • Min, B.W.1    Song, K.S.2    Bae, K.C.3    Cho, C.H.4    Kang, C.H.5    Kim, S.Y.6
  • 20
    • 0025179416 scopus 로고
    • Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components
    • PID: 2199114
    • Engh CA, Massin P, Suthers KE (1990) Roentgenographic assessment of the biologic fixation of porous-surfaced femoral components. Clin Orthop Relat Res 257:107–128
    • (1990) Clin Orthop Relat Res , vol.257 , pp. 107-128
    • Engh, C.A.1    Massin, P.2    Suthers, K.E.3
  • 21
    • 77956011162 scopus 로고    scopus 로고
    • Early post-operative periprosthetic femur fracture in the presence of a non-cemented tapered wedge femoral stem
    • PID: 21886528
    • Cooper HJ, Rodriguez JA (2010) Early post-operative periprosthetic femur fracture in the presence of a non-cemented tapered wedge femoral stem. HSS J 6(2):150–154
    • (2010) HSS J , vol.6 , Issue.2 , pp. 150-154
    • Cooper, H.J.1    Rodriguez, J.A.2
  • 22
    • 84875867519 scopus 로고    scopus 로고
    • Fracture load for periprosthetic femoral fractures in cemented versus uncemented hip stems: an experimental in vitro study
    • PID: 19292385
    • Thomsen MN, Jakubowitz E, Seeger JB, Lee C, Kretzer JP, Clarius M (2008) Fracture load for periprosthetic femoral fractures in cemented versus uncemented hip stems: an experimental in vitro study. Orthopedics 31(7):653
    • (2008) Orthopedics , vol.31 , Issue.7 , pp. 653
    • Thomsen, M.N.1    Jakubowitz, E.2    Seeger, J.B.3    Lee, C.4    Kretzer, J.P.5    Clarius, M.6
  • 23
    • 0022818102 scopus 로고
    • Threaded versus porous-surfaced designs for implant stabilization in bone-endodontic implant model
    • COI: 1:STN:280:DyaL2s%2FlslCktA%3D%3D, PID: 3782184
    • Maniatopoulos C, Pilliar RM, Smith DC (1986) Threaded versus porous-surfaced designs for implant stabilization in bone-endodontic implant model. J Biomed Mater Res 20(9):1309–1333
    • (1986) J Biomed Mater Res , vol.20 , Issue.9 , pp. 1309-1333
    • Maniatopoulos, C.1    Pilliar, R.M.2    Smith, D.C.3
  • 24
    • 0030152505 scopus 로고    scopus 로고
    • Influence of biomaterial surface texture on bone ingrowth in the rabbit femur
    • COI: 1:STN:280:DyaK283ot1Ggug%3D%3D, PID: 8676259
    • Friedman RJ, An YH, Ming J, Draughn RA, Bauer TW (1996) Influence of biomaterial surface texture on bone ingrowth in the rabbit femur. J Orthop Res 14(3):455–464
    • (1996) J Orthop Res , vol.14 , Issue.3 , pp. 455-464
    • Friedman, R.J.1    An, Y.H.2    Ming, J.3    Draughn, R.A.4    Bauer, T.W.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.