메뉴 건너뛰기




Volumn 16, Issue 4, 2015, Pages 410-416

Normal reference values of left ventricular strain using three-dimensional speckle tracking echocardiography: Results from amulticentre study

Author keywords

Echocardiography; Left ventricular function; Speckle tracking; Three dimensional imaging

Indexed keywords

ACCURACY; ADULT; AGED; ARTICLE; ECHOCARDIOGRAPH; FEMALE; HEART LEFT VENTRICLE EJECTION FRACTION; HEART LEFT VENTRICLE FUNCTION; HEART LEFT VENTRICLE MASS; HEART LEFT VENTRICLE VOLUME; HUMAN; HUMAN EXPERIMENT; INTERRATER RELIABILITY; INTRARATER RELIABILITY; MALE; MULTICENTER STUDY; NORMAL HUMAN; PRIORITY JOURNAL; REFERENCE VALUE; SPECKLE TRACKING ECHOCARDIOGRAPHY; THREE DIMENSIONAL ECHOCARDIOGRAPHY; CLINICAL TRIAL; ECHOGRAPHY; EUROPEAN UNION; HEART VENTRICLE; MIDDLE AGED; PREDICTIVE VALUE; PROCEDURES; PROSPECTIVE STUDY; REPRODUCIBILITY; SENSITIVITY AND SPECIFICITY; UNITED STATES; VERY ELDERLY;

EID: 84940382084     PISSN: 20472404     EISSN: 20472412     Source Type: Journal    
DOI: 10.1093/ehjci/jeu213     Document Type: Article
Times cited : (84)

References (27)
  • 1
    • 63549106065 scopus 로고    scopus 로고
    • Three-dimensional-wall motion tracking: A new and faster tool for myocardial strain assessment: Comparison with two-dimensional-wall motion tracking
    • Pérez de Isla L, Balcones DV, Fernández-Golfín C, Marcos-Alberca P, Almería C, Rodrigo JL et al. Three-dimensional-wall motion tracking: a new and faster tool for myocardial strain assessment: comparison with two-dimensional-wall motion tracking. J Am Soc Echocardiogr 2009;22:325-30.
    • (2009) J Am Soc Echocardiogr , vol.22 , pp. 325-330
    • De Isla, L.P.1    Balcones, D.V.2    Fernández-Golfín, C.3    Marcos-Alberca, P.4    Almería, C.5    Rodrigo, J.L.6
  • 2
    • 67650045051 scopus 로고    scopus 로고
    • Quantification of left ventricular volumes using three-dimensional echocardiographic speckle tracking: Comparison with MRI
    • Nesser HJ, Mor-Avi V, Gorissen W, Weinert L, Steringer-Mascherbauer R, Niel J et al. Quantification of left ventricular volumes using three-dimensional echocardiographic speckle tracking: comparison with MRI. Eur Heart J 2009;30:1565-73.
    • (2009) Eur Heart J , vol.30 , pp. 1565-1573
    • Nesser, H.J.1    Mor-Avi, V.2    Gorissen, W.3    Weinert, L.4    Steringer-Mascherbauer, R.5    Niel, J.6
  • 3
    • 70749115657 scopus 로고    scopus 로고
    • Quantitative evaluation of regional left ventricular function using threedimensional speckle tracking echocardiography in patients with and without heart disease
    • Maffessanti F, Nesser HJ, Weinert L, Steringer-Mascherbauer R, Niel J, GorissenW et al. Quantitative evaluation of regional left ventricular function using threedimensional speckle tracking echocardiography in patients with and without heart disease. Am J Cardiol 2009;104:1755-62.
    • (2009) Am J Cardiol , vol.104 , pp. 1755-1762
    • Maffessanti, F.1    Nesser, H.J.2    Weinert, L.3    Steringer-Mascherbauer, R.4    Niel Gorissen, J.W.5
  • 4
    • 69449098950 scopus 로고    scopus 로고
    • Comprehensive evaluation of left ventricular strain using speckle tracking echocardiography in normal adults: Comparison of three-dimensional and two-dimensional approaches
    • Saito K, Okura H, Watanabe N, Hayashida A, Obase K, Imai K et al. Comprehensive evaluation of left ventricular strain using speckle tracking echocardiography in normal adults: comparison of three-dimensional and two-dimensional approaches. J Am Soc Echocardiogr 2009;22:1025-30.
    • (2009) J Am Soc Echocardiogr , vol.22 , pp. 1025-1030
    • Saito, K.1    Okura, H.2    Watanabe, N.3    Hayashida, A.4    Obase, K.5    Imai, K.6
  • 5
    • 79951916465 scopus 로고    scopus 로고
    • Three-dimensional speckle tracking echocardiography for automatic assessment of global and regional left ventricular function based on area strain
    • Kleijn SA, Aly MF, Terwee CB, van RossumAC, Kamp O. Three-dimensional speckle tracking echocardiography for automatic assessment of global and regional left ventricular function based on area strain. J Am Soc Echocardiogr 2011;24:314-21.
    • (2011) J Am Soc Echocardiogr , vol.24 , pp. 314-321
    • Kleijn, S.A.1    Aly, M.F.2    Terwee, C.B.3    Van Rossumac Kamp, O.4
  • 6
    • 79954524790 scopus 로고    scopus 로고
    • Endocardial surface area tracking for assessment of regional LV wall deformation with 3D speckle tracking imaging
    • SeoY, IshizuT, EnomotoY, Sugimori H, AonumaK. Endocardial surface area tracking for assessment of regional LV wall deformation with 3D speckle tracking imaging. JACC Cardiovasc Imaging 2011;4:358-65.
    • (2011) JACC Cardiovasc Imaging , vol.4 , pp. 358-365
    • Seo, Y.1    Ishizu, T.2    Enomoto, Y.3    Sugimori, H.4    Aonuma, K.5
  • 7
    • 84863856142 scopus 로고    scopus 로고
    • Reliability of left ventricular volumes and function measurements using three-dimensional speckle tracking echocardiography
    • Kleijn SA, Aly MF, Terwee CB, van RossumAC, Kamp O. Reliability of left ventricular volumes and function measurements using three-dimensional speckle tracking echocardiography. Eur Heart J Cardiovasc Imaging 2012;13:159-68.
    • (2012) Eur Heart J Cardiovasc Imaging , vol.13 , pp. 159-168
    • Kleijn, S.A.1    Aly, M.F.2    Terwee, C.B.3    van RossumAC4    Kamp, O.5
  • 8
    • 84863305574 scopus 로고    scopus 로고
    • Comparison between three-dimensional speckle-tracking echocardiography and cardiac magnetic resonance imaging for quantification of left ventricular volumes and function
    • Kleijn SA, Brouwer WP, Aly MF, Russel IK, de Roest GJ, Beek AM et al. Comparison between three-dimensional speckle-tracking echocardiography and cardiac magnetic resonance imaging for quantification of left ventricular volumes and function. Eur Heart J Cardiovasc Imaging 2012;13:834-9.
    • (2012) Eur Heart J Cardiovasc Imaging , vol.13 , pp. 834-839
    • Kleijn, S.A.1    Brouwer, W.P.2    Aly, M.F.3    Russel, I.K.4    De Roest, G.J.5    Beek, A.M.6
  • 10
    • 84864282119 scopus 로고    scopus 로고
    • Threedimensional speckle-tracking analysis of left ventricular function after transcatheter aortic valve implantation
    • Schueler R, Sinning JM, Momcilovic D, Weber M, Ghanem A, WernerN et al. Threedimensional speckle-tracking analysis of left ventricular function after transcatheter aortic valve implantation. J Am Soc Echocardiogr 2012;25:827-34.
    • (2012) J Am Soc Echocardiogr , vol.25 , pp. 827-834
    • Schueler, R.1    Sinning, J.M.2    Momcilovic Dweber, M.3    Ghanem, A.4    Werner, N.5
  • 11
    • 84155165134 scopus 로고    scopus 로고
    • Evaluation of global left ventricular systolic function using three-dimensional echocardiography speckletracking strain parameters
    • Reant P, Barbot L, Touche C, Dijos M, Arsac F, Pillois X et al. Evaluation of global left ventricular systolic function using three-dimensional echocardiography speckletracking strain parameters. J Am Soc Echocardiogr 2012;25:68-79.
    • (2012) J Am Soc Echocardiogr , vol.25 , pp. 68-79
    • Reant, P.1    Barbot, L.2    Touche, C.3    Dijos, M.4    Arsac, F.5    Pillois, X.6
  • 12
    • 84885022905 scopus 로고    scopus 로고
    • Evaluation of myocardial mechanics with three-dimensional speckle tracking echocardiography in heart transplant recipients: Comparison with two-dimensional speckle tracking and relationship with clinical variables
    • Urbano-Moral JA, Arias-Godinez JA, Ahmad R, Malik R, Kiernan MS, DenofrioD et al. Evaluation of myocardial mechanics with three-dimensional speckle tracking echocardiography in heart transplant recipients: comparison with two-dimensional speckle tracking and relationship with clinical variables. Eur Heart J Cardiovasc Imaging 2013;14:1167-73.
    • (2013) Eur Heart J Cardiovasc Imaging , vol.14 , pp. 1167-1173
    • Urbano-Moral, J.A.1    Arias-Godinez, J.A.2    Ahmad, R.3    Malik, R.4    Kiernan, M.S.5    Denofrio, D.6
  • 13
    • 0034999429 scopus 로고    scopus 로고
    • Regional nonuniformity of normal adult human left ventricle
    • Bogaert J, Rademakers FE. Regional nonuniformity of normal adult human left ventricle. Am J Physiol Heart Circ Physiol 2001;280:H610-20.
    • (2001) Am J Physiol Heart Circ Physiol , vol.280 , pp. H610-H620
    • Bogaert, J.1    Rademakers, F.E.2
  • 14
    • 58149339679 scopus 로고    scopus 로고
    • Myocardial strain measurement with 2-dimensional speckle-tracking echocardiography: Definition of normal range
    • Marwick TH, Leano RL, Brown J, Sun JP, Hoffmann R, Lysyansky P et al. Myocardial strain measurement with 2-dimensional speckle-tracking echocardiography: definition of normal range. JACC Cardiovasc Imaging 2009;2:80-4.
    • (2009) JACC Cardiovasc Imaging , vol.2 , pp. 80-84
    • Marwick, T.H.1    Leano, R.L.2    Brown, J.3    Sun, J.P.4    Hoffmann, R.5    Lysyansky, P.6
  • 15
    • 29244432482 scopus 로고    scopus 로고
    • Recommendations for chamber quantification: A report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology
    • Lang RM, Bierig M, Devereux RB, Flachskampf FA, Foster E, Pellikka PA et al. Recommendations for chamber quantification: a report from the American Society of Echocardiography's Guidelines and Standards Committee and the Chamber Quantification Writing Group, developed in conjunction with the European Association of Echocardiography, a branch of the European Society of Cardiology. J Am Soc Echocardiogr 2005;18:1440-63.
    • (2005) J Am Soc Echocardiogr , vol.18 , pp. 1440-1463
    • Lang, R.M.1    Bierig, M.2    Devereux, R.B.3    Flachskampf, F.A.4    Foster, E.5    Pellikka, P.A.6
  • 17
    • 84865473523 scopus 로고    scopus 로고
    • Comparison of anewmethodology for the assessment of3Dmyocardial strain from volumetric ultrasound with 2D speckle tracking
    • Jasaityte R, Heyde B, FerferievaV, Amundsen B, Barbosa D, LoeckxD et al. Comparison of anewmethodology for the assessment of3Dmyocardial strain from volumetric ultrasound with 2D speckle tracking. Int J Cardiovasc Imaging 2012;28:1049-60.
    • (2012) Int J Cardiovasc Imaging , vol.28 , pp. 1049-1060
    • Jasaityte, R.1    Heyde, B.2    Ferferieva, V.3    Amundsen, B.4    Barbosa, D.5    Loeckx, D.6
  • 20
    • 84871387168 scopus 로고    scopus 로고
    • Current state of three-dimensional myocardial strain estimation using echocardiography
    • Jasaityte R, Heyde B, D'hooge J. Current state of three-dimensional myocardial strain estimation using echocardiography. J Am Soc Echocardiogr 2013;26:15-28.
    • (2013) J Am Soc Echocardiogr , vol.26 , pp. 15-28
    • Jasaityte, R.1    Heyde, B.2    D'Hooge, J.3
  • 23
    • 84878268655 scopus 로고    scopus 로고
    • Comprehensive analysis of left ventricular geometry and function by threedimensional echocardiography in healthy adults
    • Muraru D, Badano LP, Peluso D, Dal Bianco L, Casablanca S, Kocabay G et al. Comprehensive analysis of left ventricular geometry and function by threedimensional echocardiography in healthy adults. J Am Soc Echocardiogr 2013;26: 618-28.
    • (2013) J Am Soc Echocardiogr , vol.26 , pp. 618-628
    • Muraru, D.1    Badano, L.P.2    Peluso, D.3    Dal Bianco, L.4    Casablanca, S.5    Kocabay, G.6
  • 24
    • 79960834392 scopus 로고    scopus 로고
    • Reproducibility and inter-vendor variability of left ventricular deformation measurements by three-dimensional speckle-tracking echocardiography
    • Gayat E, AhmadH, Weinert L, Lang RM, Mor-AviV. Reproducibility and inter-vendor variability of left ventricular deformation measurements by three-dimensional speckle-tracking echocardiography. J Am Soc Echocardiogr 2011;24:878-85.
    • (2011) J Am Soc Echocardiogr , vol.24 , pp. 878-885
    • Gayat, E.1    Ahmad, H.2    Weinert, L.3    Lang, R.M.4    Mor-Avi, V.5
  • 25
    • 84874312763 scopus 로고    scopus 로고
    • Use of three-dimensional speckle tracking to assess left ventricular myocardial mechanics: Inter-vendor consistency and reproducibility of strain measurements
    • Badano LP, Cucchini U, Muraru D, Al Nono O, Sarais C, Iliceto S. Use of three-dimensional speckle tracking to assess left ventricular myocardial mechanics: inter-vendor consistency and reproducibility of strain measurements. Eur Heart J Cardiovasc Imaging 2013;14:285-93.
    • (2013) Eur Heart J Cardiovasc Imaging , vol.14 , pp. 285-293
    • Badano, L.P.1    Cucchini, U.2    Muraru, D.3    Al Nono, O.4    Sarais, C.5    Iliceto, S.6
  • 26
    • 84896545069 scopus 로고    scopus 로고
    • Age-related normal range of left ventricular strain and torsion using three-dimensional speckletracking echocardiography
    • Kaku K, Takeuchi M, TsangW, Takigiku K, Yasukochi S, Patel AR et al. Age-related normal range of left ventricular strain and torsion using three-dimensional speckletracking echocardiography. J Am Soc Echocardiogr 2014;27:55-64.
    • (2014) J Am Soc Echocardiogr , vol.27 , pp. 55-64
    • Kaku, K.1    Takeuchi, M.2    Tsang, W.3    Takigiku, K.4    Yasukochi, S.5    Patel, A.R.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.