메뉴 건너뛰기




Volumn 17, Issue 6, 2015, Pages 884-890

Subclavian vein pacing and venous pressure waveform measurement for phrenic nerve monitoring during cryoballoon ablation of atrial fibrillation

Author keywords

Atrial fibrillation; Cryoballoon; Phrenic nerve palsy

Indexed keywords

ABLATION THERAPY; ADULT; AGED; ARTICLE; ATRIAL FIBRILLATION; CRYOABLATION; CRYOBALLOON ABLATION; DIAPHRAGM; HUMAN; MAJOR CLINICAL STUDY; NERVE FUNCTION; NERVE STIMULATION; PHRENIC NERVE; PHRENIC NERVE PARALYSIS; PRESSURE MEASUREMENT; PRIORITY JOURNAL; RIGHT SUBCLAVIAN VEIN; SUBCLAVIAN VEIN; SUPERIOR CAVA VEIN; VENOUS PRESSURE; WAVEFORM; ADVERSE EFFECTS; CLINICAL TRIAL; COHORT ANALYSIS; CRYOSURGERY; ELECTROSTIMULATION; FEMORAL VEIN; HEART PACING; INJURIES; INNERVATION; INTRAOPERATIVE MONITORING; MUSCLE CONTRACTION; PERIPHERAL NERVE INJURIES; PHYSIOLOGY; PROCEDURES; PULSE WAVE;

EID: 84939560255     PISSN: 10995129     EISSN: 15322092     Source Type: Journal    
DOI: 10.1093/europace/euu341     Document Type: Article
Times cited : (43)

References (14)
  • 1
    • 84855489815 scopus 로고    scopus 로고
    • Efficacy and safety of cryoballoon ablation for atrial fibrillation: A systematic review of published studies
    • Andrade JG, Khairy P, Guerra PG, Deyell MW, Rivard L, Macle L et al. Efficacy and safety of cryoballoon ablation for atrial fibrillation: A systematic review of published studies. Heart Rhythm 2011;8:1444-51.
    • (2011) Heart Rhythm , vol.8 , pp. 1444-1451
    • Andrade, J.G.1    Khairy, P.2    Guerra, P.G.3    Deyell, M.W.4    Rivard, L.5    MacLe, L.6
  • 3
    • 84876689183 scopus 로고    scopus 로고
    • Immediate balloon deflation for prevention of persistent phrenic nerve palsy during pulmonary vein isolation by balloon cryoablation
    • Ghosh J, Sepahpour A, Chan KH, Singarayar S, McGuire MA. Immediate balloon deflation for prevention of persistent phrenic nerve palsy during pulmonary vein isolation by balloon cryoablation. Heart Rhythm 2013;10:646-52.
    • (2013) Heart Rhythm , vol.10 , pp. 646-652
    • Ghosh, J.1    Sepahpour, A.2    Chan, K.H.3    Singarayar, S.4    McGuire, M.A.5
  • 4
    • 84868666658 scopus 로고    scopus 로고
    • Left phrenic nerve injury during cryoballoon ablation of the left superior pulmonary vein
    • Andrié R, Schrickel JW, Nickenig G, Lickfett L. Left phrenic nerve injury during cryoballoon ablation of the left superior pulmonary vein. Pacing Clin Electrophysiol 2012;35:e334-6.
    • (2012) Pacing Clin Electrophysiol , vol.35 , pp. e334-e336
    • Andrié, R.1    Schrickel, J.W.2    Nickenig, G.3    Lickfett, L.4
  • 5
    • 84875982769 scopus 로고    scopus 로고
    • Left phrenic nerve injury after cryoballoon ablation of the pulmonary veins
    • Hermida J-S, Traullé S, Kubala M. Left phrenic nerve injury after cryoballoon ablation of the pulmonary veins. Europace 2013;15:514.
    • (2013) Europace , vol.15 , pp. 514
    • Hermida, J.-S.1    Traullé, S.2    Kubala, M.3
  • 6
    • 84859509560 scopus 로고    scopus 로고
    • 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design
    • Calkins H, Kuck KH, Cappato R, Brugada J, Camm AJ, Chen SA et al. 2012 HRS/EHRA/ECAS expert consensus statement on catheter and surgical ablation of atrial fibrillation: Recommendations for patient selection, procedural techniques, patient management and follow-up, definitions, endpoints, and research trial design. Europace 2012;14:528-606.
    • (2012) Europace , vol.14 , pp. 528-606
    • Calkins, H.1    Kuck, K.H.2    Cappato, R.3    Brugada, J.4    Camm, A.J.5    Chen, S.A.6
  • 7
    • 84883226667 scopus 로고    scopus 로고
    • Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation
    • Ghosh J, Martin A, Keech AC, Chan KH, Gomes S, Singarayar S et al. Balloon warming time is the strongest predictor of late pulmonary vein electrical reconnection following cryoballoon ablation for atrial fibrillation. Heart Rhythm 2013;10: 1311-7.
    • (2013) Heart Rhythm , vol.10 , pp. 1311-1317
    • Ghosh, J.1    Martin, A.2    Keech, A.C.3    Chan, K.H.4    Gomes, S.5    Singarayar, S.6
  • 9
    • 84866175478 scopus 로고    scopus 로고
    • Electrical isolation of the superior vena cava using upstream phrenic pacing to avoid phrenic nerve injury
    • Kimura T, Takatsuki S, Fukumoto K, Nishiyama N, Sato Y, Aizawa Y et al. Electrical isolation of the superior vena cava using upstream phrenic pacing to avoid phrenic nerve injury. Pacing Clin Electrophysiol 2012;35:1053-60.
    • (2012) Pacing Clin Electrophysiol , vol.35 , pp. 1053-1060
    • Kimura, T.1    Takatsuki, S.2    Fukumoto, K.3    Nishiyama, N.4    Sato, Y.5    Aizawa, Y.6
  • 10
    • 79960021173 scopus 로고    scopus 로고
    • Phrenic nerve monitoring with diaphragmatic electromyography during cryoballoon ablation for atrial fibrillation: The first human application
    • Franceschi F, Dubuc M, Guerra PG, Khairy P. Phrenic nerve monitoring with diaphragmatic electromyography during cryoballoon ablation for atrial fibrillation: The first human application. Heart Rhythm 2011;8:1068-71.
    • (2011) Heart Rhythm , vol.8 , pp. 1068-1071
    • Franceschi, F.1    Dubuc, M.2    Guerra, P.G.3    Khairy, P.4
  • 11
    • 84905920490 scopus 로고    scopus 로고
    • Fluoroscopy of spontaneous breathing is more sensitive than phrenic nerve stimulation for detection of right phrenic nerve injury during cryoballoon ablation of atrial fibrillation
    • Linahart M, Nielson A, Andrie RP, Mittman-Braun EL, Stockigt F, Kreuz J et al. Fluoroscopy of spontaneous breathing is more sensitive than phrenic nerve stimulation for detection of right phrenic nerve injury during cryoballoon ablation of atrial fibrillation. J Cardiovasc Electrophysiol 2014;25:859-65.
    • (2014) J Cardiovasc Electrophysiol , vol.25 , pp. 859-865
    • Linahart, M.1    Nielson, A.2    Andrie, R.P.3    Mittman-Braun, E.L.4    Stockigt, F.5    Kreuz, J.6
  • 12
    • 84894533867 scopus 로고    scopus 로고
    • Safety and efficacy of a second-generation cryoballoon in the ablation of paroxysmal atrial fibrillation
    • Martins RP, Hamon D, Césari O, Behaghel A, Behar N, Sellal J-M et al. Safety and efficacy of a second-generation cryoballoon in the ablation of paroxysmal atrial fibrillation. Heart Rhythm 2014;11:386-93.
    • (2014) Heart Rhythm , vol.11 , pp. 386-393
    • Martins, R.P.1    Hamon, D.2    Césari, O.3    Behaghel, A.4    Behar, N.5    Sellal, J.-M.6
  • 13
    • 84883215266 scopus 로고    scopus 로고
    • Phrenic nerve paralysis during cryoballoon ablation for atrial fibrillation: A comparison between the first- And second-generation balloon
    • Casado-Arroyo R, Chierchia G-B, Conte G, Levinstein M, Sieira J, Rodriguez- Mañero M et al. Phrenic nerve paralysis during cryoballoon ablation for atrial fibrillation: A comparison between the first- And second-generation balloon. Heart Rhythm 2013;10:1318-24.
    • (2013) Heart Rhythm , vol.10 , pp. 1318-1324
    • Casado-Arroyo, R.1    Chierchia, G.-B.2    Conte, G.3    Levinstein, M.4    Sieira, J.5    Rodriguez-, M.M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.