메뉴 건너뛰기




Volumn 1, Issue 1, 2014, Pages 1-13

Effective dose to adult patients from 338 radiopharmaceuticals estimated using ICRP biokinetic data, ICRP/ICRU computational reference phantoms and ICRP 2007 tissue weighting factors

Author keywords

Diagnostics; ICRP; Internal dosimetry; Nuclear medicine; Radiopharmaceuticals

Indexed keywords


EID: 84939544412     PISSN: None     EISSN: 21977364     Source Type: Journal    
DOI: 10.1186/2197-7364-1-9     Document Type: Article
Times cited : (57)

References (23)
  • 7
    • 0034959155 scopus 로고    scopus 로고
    • The adult male voxel model “Golem” segmented from whole-body CT patient data
    • COI: 1:STN:280:DC%2BD38%2FisFyrtg%3D%3D, PID: 11484787
    • Zankl M, Wittmann A: The adult male voxel model “Golem” segmented from whole-body CT patient data.Radiat Environ Biophys 2001,40(2):153–162. 10.1007/s004110100094
    • (2001) Radiat Environ Biophys , vol.40 , Issue.2 , pp. 153-162
    • Zankl, M.1    Wittmann, A.2
  • 10
    • 84863517907 scopus 로고    scopus 로고
    • Electron specific absorbed fractions for the adult male and female ICRP/ICRU reference computational phantoms
    • PID: 22722546
    • Zankl M, Schlattl H, Petoussi-Henss N, Hoeschen C: Electron specific absorbed fractions for the adult male and female ICRP/ICRU reference computational phantoms.Phys Med Biol 2012,57(14):4501–4526. 10.1088/0031-9155/57/14/4501
    • (2012) Phys Med Biol , vol.57 , Issue.14 , pp. 4501-4526
    • Zankl, M.1    Schlattl, H.2    Petoussi-Henss, N.3    Hoeschen, C.4
  • 11
    • 84928671224 scopus 로고    scopus 로고
    • An internal radiation dosimetry computer program, IDAC2.0, for estimation of patient dose for radiopharmaceuticals
    • doi:10.1093/rpd/nct337
    • Andersson M, Johansson L, Minarik D, Mattsson S, Leide-Svegborn S: An internal radiation dosimetry computer program, IDAC2.0, for estimation of patient dose for radiopharmaceuticals.Radiat Prot Dosimetry 2013. doi:10.1093/rpd/nct337
    • (2013) Radiat Prot Dosimetry
    • Andersson, M.1    Johansson, L.2    Minarik, D.3    Mattsson, S.4    Leide-Svegborn, S.5
  • 12
    • 84883197752 scopus 로고    scopus 로고
    • Evaluation of absorbed and effective doses to patients from radiopharmaceuticals using the ICRP 110 reference computational phantoms and ICRP 103 formulation
    • COI: 1:CAS:528:DC%2BC3sXhtleksbjO, PID: 23525914
    • Hadid L, Gardumi A, Desbree A: Evaluation of absorbed and effective doses to patients from radiopharmaceuticals using the ICRP 110 reference computational phantoms and ICRP 103 formulation.Radiat Prot Dosimetry 2013,156(2):141–159. 10.1093/rpd/nct049
    • (2013) Radiat Prot Dosimetry , vol.156 , Issue.2 , pp. 141-159
    • Hadid, L.1    Gardumi, A.2    Desbree, A.3
  • 16
    • 62449175592 scopus 로고    scopus 로고
    • MIRD pamphlet No. 21: a generalized schema for radiopharmaceutical dosimetry–standardization of nomenclature
    • COI: 1:CAS:528:DC%2BD1MXktVyns7k%3D, PID: 19258258
    • Bolch WE, Eckerman KF, Sgouros G, Thomas SR: MIRD pamphlet No. 21: a generalized schema for radiopharmaceutical dosimetry–standardization of nomenclature.J Nucl Med 2009,50(3):477–484. 10.2967/jnumed.108.056036
    • (2009) J Nucl Med , vol.50 , Issue.3 , pp. 477-484
    • Bolch, W.E.1    Eckerman, K.F.2    Sgouros, G.3    Thomas, S.R.4
  • 22
    • 0029047087 scopus 로고
    • A proposed blood circulation model for Reference Man
    • COI: 1:CAS:528:DyaK2MXntFGlsr4%3D, PID: 7622365
    • Leggett RW, Williams LR: A proposed blood circulation model for Reference Man.Health Phys 1995,69(2):187–201. 10.1097/00004032-199508000-00003
    • (1995) Health Phys , vol.69 , Issue.2 , pp. 187-201
    • Leggett, R.W.1    Williams, L.R.2
  • 23
    • 81355142176 scopus 로고    scopus 로고
    • Current activities in the ICRP concerning estimation of radiation doses to patients from radiopharmaceuticals for diagnostic use
    • Mattsson S, Johansson L, Leide-Svegborn S, Liniecki J, Nosske D, Riklund K, Stabin M, Taylor D: Current activities in the ICRP concerning estimation of radiation doses to patients from radiopharmaceuticals for diagnostic use.J Phys Conf Ser 2011, 317: 012008. doi:10.1088/1742–6596/317/1/012008
    • (2011) J Phys Conf Ser , vol.317 , pp. 012008
    • Mattsson, S.1    Johansson, L.2    Leide-Svegborn, S.3    Liniecki, J.4    Nosske, D.5    Riklund, K.6    Stabin, M.7    Taylor, D.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.