Volumn 8, Issue 9, 2015, Pages 1218-1228

Inverse Relationship between Membranous Septal Length and the Risk of Atrioventricular Block in Patients Undergoing Transcatheter Aortic Valve Implantation

Author keywords

atrioventricular block; CT; implantation depth; membranous septum; permanent pacemaker; TAVI

Indexed keywords

AGED; AORTA STENOSIS; ATRIOVENTRICULAR MEMBRANOUS SEPTUM; CARDIAC IMAGING; CARDIOVASCULAR RISK; COMPUTER ASSISTED TOMOGRAPHY; CONTRAST ENHANCEMENT; FEMALE; HEART VENTRICLE SEPTUM; HUMAN; MAJOR CLINICAL STUDY; MALE; PACEMAKER IMPLANTATION; PRIORITY JOURNAL; PROGNOSIS; REVIEW; SECOND DEGREE ATRIOVENTRICULAR BLOCK; TRANSCATHETER AORTIC VALVE IMPLANTATION; ADVERSE EFFECTS; AORTA VALVE; AORTIC VALVE STENOSIS; ATRIOVENTRICULAR BLOCK; DEVICES; HEART CATHETERIZATION; HEART PACING; HEART SEPTUM; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; MULTIDETECTOR COMPUTED TOMOGRAPHY; MULTIVARIATE ANALYSIS; ODDS RATIO; PATHOPHYSIOLOGY; PREDICTIVE VALUE; RADIOGRAPHY; RISK ASSESSMENT; RISK FACTOR; SEVERITY OF ILLNESS INDEX; STATISTICAL MODEL; TREATMENT OUTCOME; VERY ELDERLY;

EID: 84939474780     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2015.05.010     Document Type: Article
Times cited : (187)

References (16)
  • 3
    • 44949088496 scopus 로고    scopus 로고
    • Early and persistent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve
    • N. Piazza, Y. Onuma, E. Jesserun, and et al. Early and persistent intraventricular conduction abnormalities and requirements for pacemaking after percutaneous replacement of the aortic valve J Am Coll Cardiol Intv 1 2008 310 316
    • (2008) J Am Coll Cardiol Intv , vol.1 , pp. 310-316
    • Piazza, N.1    Onuma, Y.2    Jesserun, E.3
  • 4
    • 84864285945 scopus 로고    scopus 로고
    • New conduction abnormalities after TAVI-frequency and causes
    • R.M. Van der Boon, R.J. Nuis, N.M. Van Mieghem, and et al. New conduction abnormalities after TAVI-frequency and causes Nat Rev Cardiol 9 2012 454 463
    • (2012) Nat Rev Cardiol , vol.9 , pp. 454-463
    • Van Der Boon, R.M.1    Nuis, R.J.2    Van Mieghem, N.M.3
  • 5
    • 77955617014 scopus 로고    scopus 로고
    • Predictors for new-onset complete heart block after transcatheter aortic valve implantation
    • S. Bleiziffer, H. Ruge, J. Hörer, and et al. Predictors for new-onset complete heart block after transcatheter aortic valve implantation J Am Coll Cardiol Intv 3 2010 524 530
    • (2010) J Am Coll Cardiol Intv , vol.3 , pp. 524-530
    • Bleiziffer, S.1    Ruge, H.2    Hörer, J.3
  • 6
    • 84855403987 scopus 로고    scopus 로고
    • Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: Insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy
    • A. Hamdan, V. Guetta, E. Konen, and et al. Deformation dynamics and mechanical properties of the aortic annulus by 4-dimensional computed tomography: insights into the functional anatomy of the aortic valve complex and implications for transcatheter aortic valve therapy J Am Coll Cardiol 59 2012 119 127
    • (2012) J Am Coll Cardiol , vol.59 , pp. 119-127
    • Hamdan, A.1    Guetta, V.2    Konen, E.3
  • 7
    • 79952200980 scopus 로고    scopus 로고
    • The use of MSCT for the evaluation of the aortic root before transcutaneous aortic valve implantation: The Rotterdam approach
    • C. Schultz, A. Moelker, A. Tzikas, and et al. The use of MSCT for the evaluation of the aortic root before transcutaneous aortic valve implantation: the Rotterdam approach EuroIntervention 6 2010 505 511
    • (2010) EuroIntervention , vol.6 , pp. 505-511
    • Schultz, C.1    Moelker, A.2    Tzikas, A.3
  • 8
    • 84870743337 scopus 로고    scopus 로고
    • J SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR)
    • S. Achenbach, V. Delgado, J. Hausleiter, P. Schoenhagen, J.K. Min, and J.A. Leipsic J SCCT expert consensus document on computed tomography imaging before transcatheter aortic valve implantation (TAVI)/transcatheter aortic valve replacement (TAVR) Cardiovasc Comput Tomogr 6 2012 366 380
    • (2012) Cardiovasc Comput Tomogr , vol.6 , pp. 366-380
    • Achenbach, S.1    Delgado, V.2    Hausleiter, J.3    Schoenhagen, P.4    Min, J.K.5    Leipsic, J.A.6
  • 9
    • 84867839502 scopus 로고    scopus 로고
    • Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve
    • M. Urena, M. Mok, V. Serra, and et al. Predictive factors and long-term clinical consequences of persistent left bundle branch block following transcatheter aortic valve implantation with a balloon-expandable valve J Am Coll Cardiol 60 2012 1743 1752
    • (2012) J Am Coll Cardiol , vol.60 , pp. 1743-1752
    • Urena, M.1    Mok, M.2    Serra, V.3
  • 10
    • 0032525017 scopus 로고    scopus 로고
    • Maximum likelihood estimation of receiver operating characteristic (ROC) curve from continuously distributed data
    • C.E. Metz, B.A. Herman, and J.H. Shen Maximum likelihood estimation of receiver operating characteristic (ROC) curve from continuously distributed data Stat Med 17 1998 1033 1053
    • (1998) Stat Med , vol.17 , pp. 1033-1053
    • Metz, C.E.1    Herman, B.A.2    Shen, J.H.3
  • 11
    • 79958084913 scopus 로고    scopus 로고
    • Receiver operating characteristic (ROC) curve for medical researchers
    • R. Kumar, and A. Indrayan Receiver operating characteristic (ROC) curve for medical researchers Indian Pediatr 48 2011 277 287
    • (2011) Indian Pediatr , vol.48 , pp. 277-287
    • Kumar, R.1    Indrayan, A.2
  • 12
    • 44949107393 scopus 로고    scopus 로고
    • Atrioventricular block after transcatheter balloon expandable aortic valve implantation
    • A. Sinhal, L. Altwegg, S. Pasupati, and et al. Atrioventricular block after transcatheter balloon expandable aortic valve implantation J Am Coll Cardiol Intv 1 2008 305 309
    • (2008) J Am Coll Cardiol Intv , vol.1 , pp. 305-309
    • Sinhal, A.1    Altwegg, L.2    Pasupati, S.3
  • 13
    • 60949086687 scopus 로고    scopus 로고
    • Early conduction disorders following percutaneous aortic valve replacement
    • V. Calvi, E. Puzzangara, G.P. Pruiti, and et al. Early conduction disorders following percutaneous aortic valve replacement Pacing Clin Electrophysiol 32 Suppl 1 2009 S126 S130
    • (2009) Pacing Clin Electrophysiol , vol.32 , pp. S126-S130
    • Calvi, V.1    Puzzangara, E.2    Pruiti, G.P.3
  • 14
    • 80955163682 scopus 로고    scopus 로고
    • Predictors and course of high-degree atrioventricular block after transcatheter aortic valve implantation using the CoreValve Revalving System
    • V. Guetta, G. Goldenberg, A. Segev, and et al. Predictors and course of high-degree atrioventricular block after transcatheter aortic valve implantation using the CoreValve Revalving System Am J Cardiol 108 2011 1600 1605
    • (2011) Am J Cardiol , vol.108 , pp. 1600-1605
    • Guetta, V.1    Goldenberg, G.2    Segev, A.3
  • 15
    • 84908228604 scopus 로고    scopus 로고
    • Depth of valve implantation, conduction disturbances and pacemaker implantation with CoreValve and CoreValve Accutrak system for Transcatheter Aortic Valve Implantation, a multi-center study
    • G.D. Lenders, V. Collas, J.M. Hernandez, and et al. Depth of valve implantation, conduction disturbances and pacemaker implantation with CoreValve and CoreValve Accutrak system for Transcatheter Aortic Valve Implantation, a multi-center study Int J Cardiol 176 2014 771 775
    • (2014) Int J Cardiol , vol.176 , pp. 771-775
    • Lenders, G.D.1    Collas, V.2    Hernandez, J.M.3
  • 16
    • 84881257640 scopus 로고    scopus 로고
    • 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: The Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA)
    • M. Brignole, A. Auricchio, G. Baron-Esquivias, and et al. 2013 ESC Guidelines on cardiac pacing and cardiac resynchronization therapy: the Task Force on cardiac pacing and resynchronization therapy of the European Society of Cardiology (ESC). Developed in collaboration with the European Heart Rhythm Association (EHRA) Eur Heart J 34 2013 2281 2329
    • (2013) Eur Heart J , vol.34 , pp. 2281-2329
    • Brignole, M.1    Auricchio, A.2    Baron-Esquivias, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.