메뉴 건너뛰기




Volumn 2014-May, Issue , 2014, Pages

Battery optimization in smartphones for remote health monitoring systems to enhance user adherence

Author keywords

Power optimization; Remote health monitoring; User adherence

Indexed keywords

ELECTRIC BATTERIES; MHEALTH; SMARTPHONES;

EID: 84939222628     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1145/2674396.2674407     Document Type: Conference Paper
Times cited : (13)

References (13)
  • 2
    • 84884610323 scopus 로고    scopus 로고
    • Robust human intensity-varying activity recognition using stochastic approximation in wearable sensors
    • N. Alshurafa, W. Xu, J. J. Liu, M.-C. Huang, B. Mortazavi, M. Sarrafzadeh, and C. K. Roberts. Robust human intensity-varying activity recognition using stochastic approximation in wearable sensors. In BSN'13, pages 1-6, 2013.
    • (2013) BSN'13 , pp. 1-6
    • Alshurafa, N.1    Xu, W.2    Liu, J.J.3    Huang, M.-C.4    Mortazavi, B.5    Sarrafzadeh, M.6    Roberts, C.K.7
  • 4
    • 36048973531 scopus 로고    scopus 로고
    • Randomized trial of Telemonitoring to Improve Heart Failure Outcomes (Tele-HF): Study design
    • Nov
    • S. I. Chaudhry, B. Barton, J. Mattera, J. Spertus, and H. M. Krumholz. Randomized trial of Telemonitoring to Improve Heart Failure Outcomes (Tele-HF): study design. J. Card. Fail., 13(9):709-714, Nov 2007.
    • (2007) J. Card. Fail , vol.13 , Issue.9 , pp. 709-714
    • Chaudhry, S.I.1    Barton, B.2    Mattera, J.3    Spertus, J.4    Krumholz, H.M.5
  • 5
    • 77956427591 scopus 로고    scopus 로고
    • Medially: A provenance-aware remote health monitoring middleware
    • A. R. Chowdhury, B. Falchuk, and A. Misra. Medially: A provenance-aware remote health monitoring middleware. In PerCom'10, pages 125-134, 2010.
    • (2010) PerCom'10 , pp. 125-134
    • Chowdhury, A.R.1    Falchuk, B.2    Misra, A.3
  • 6
    • 78649812846 scopus 로고    scopus 로고
    • Connecting the circle from home to heart-failure disease management
    • Dec
    • A. S. Desai and L. W. Stevenson. Connecting the circle from home to heart-failure disease management. N. Engl. J. Med., 363(24):2364-2367, Dec 2010.
    • (2010) N. Engl. J. Med , vol.363 , Issue.24 , pp. 2364-2367
    • Desai, A.S.1    Stevenson, L.W.2
  • 7
    • 84871558065 scopus 로고    scopus 로고
    • Opportunistic hierarchical classification for power optimization in wearable movement monitoring systems
    • IEEE
    • F. Fraternali, M. Rofouei, N. Alshurafa, H. Ghasemzadeh, L. Benini, and M. Sarrafzadeh. Opportunistic hierarchical classification for power optimization in wearable movement monitoring systems. In SIES, pages 102-111. IEEE, 2012.
    • (2012) SIES , pp. 102-111
    • Fraternali, F.1    Rofouei, M.2    Alshurafa, N.3    Ghasemzadeh, H.4    Benini, L.5    Sarrafzadeh, M.6
  • 9
    • 77953155714 scopus 로고    scopus 로고
    • A wearable smartphone-based platform for real-time cardiovascular disease detection via electrocardiogram processing
    • May
    • J. J. Oresko, H. Duschl, and A. C. Cheng. A wearable smartphone-based platform for real-time cardiovascular disease detection via electrocardiogram processing. IEEE Trans Inf Technol Biomed, 14(3):734-740, May 2010.
    • (2010) IEEE Trans Inf Technol Biomed , vol.14 , Issue.3 , pp. 734-740
    • Oresko, J.J.1    Duschl, H.2    Cheng, A.C.3
  • 12
    • 79951785219 scopus 로고    scopus 로고
    • Development and feasibility of a smartphone, ecg and GPS based system for remotely monitoring exercise in cardiac rehabilitation
    • C. Worringham, A. Rojek, and I. Stewart. Development and feasibility of a smartphone, ecg and gps based system for remotely monitoring exercise in cardiac rehabilitation. PLoS ONE, 6, 02 2011.
    • (2011) PLoS ONE , vol.6 , pp. 02
    • Worringham, C.1    Rojek, A.2    Stewart, I.3
  • 13
    • 58549086936 scopus 로고    scopus 로고
    • Light-intensity activities are important for estimating physical activity energy expenditure using uniaxial and triaxial accelerometers
    • Jan
    • Y. Yamada, K. Yokoyama, R. Noriyasu, T. Osaki, T. Adachi, A. Itoi, Y. Naito, T. Morimoto, M. Kimura, and S. Oda. Light-intensity activities are important for estimating physical activity energy expenditure using uniaxial and triaxial accelerometers. Eur. J. Appl. Physiol., 105(1):141-152, Jan 2009.
    • (2009) Eur. J. Appl. Physiol , vol.105 , Issue.1 , pp. 141-152
    • Yamada, Y.1    Yokoyama, K.2    Noriyasu, R.3    Osaki, T.4    Adachi, T.5    Itoi, A.6    Naito, Y.7    Morimoto, T.8    Kimura, M.9    Oda, S.10


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.