메뉴 건너뛰기




Volumn BME-34, Issue 2, 1987, Pages 98-105

Spatial Filtering of Noninvasive Multielectrode EMG: Part I—Introduction to Measuring Technique and Applications

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL EQUIPMENT; SIGNAL FILTERING AND PREDICTION; SIGNAL PROCESSING;

EID: 84939033845     PISSN: 00189294     EISSN: 15582531     Source Type: Journal    
DOI: 10.1109/TBME.1987.326034     Document Type: Article
Times cited : (135)

References (29)
  • 2
    • 0014871809 scopus 로고
    • Muscular fatigue and action potential conduction velocity changes studied with frequency analysis of EMG signals
    • L. Lindstrom, R. Magnusson, and I. Petersen, “Muscular fatigue and action potential conduction velocity changes studied with frequency analysis of EMG signals,” Electromyogr., vol. 10, pp. 341–356, 1970.
    • (1970) Electromyogr. , vol.10 , pp. 341-356
    • Lindstrom, L.1    Magnusson, R.2    Petersen, I.3
  • 3
    • 0020569691 scopus 로고
    • The propagation of motor unit action potential and the location of neuromuscular junction investigated by surface electrode arrays
    • T. Masuda, H. Miyano, and T. Sadoyama, “The propagation of motor unit action potential and the location of neuromuscular junction investigated by surface electrode arrays,” Electroenceph. Clin. Neurophysiol, vol. 55, pp. 594–600, 1983.
    • (1983) Electroenceph. Clin. Neurophysiol , vol.55 , pp. 594-600
    • Masuda, T.1    Miyano, H.2    Sadoyama, T.3
  • 4
    • 0021352037 scopus 로고
    • Normal and myopathic propagation of surface motor unit action potentials
    • P. Hilfiker and M. Meyer, “Normal and myopathic propagation of surface motor unit action potentials,” Electroenceph. Clin. Neurophysiol., vol. 57, pp. 21–31, 1984.
    • (1984) Electroenceph. Clin. Neurophysiol. , vol.57 , pp. 21-31
    • Hilfiker, P.1    Meyer, M.2
  • 6
    • 0022270423 scopus 로고
    • A microprocessor-based polarity correlator for the on-line measurement of muscle fiber conduction velocity
    • Dec.
    • M. I. A. Harba and A. K. Naief, “A microprocessor-based polarity correlator for the on-line measurement of muscle fiber conduction velocity,” IEEE Trans. Biomed. Eng., vol. BME-32, pp. 1071–1077, Dec. 1985.
    • (1985) IEEE Trans. Biomed. Eng. , vol.BME-32 , pp. 1071-1077
    • Harba, M.I.A.1    Naief, A.K.2
  • 7
    • 0021890397 scopus 로고
    • A note on the noninvasive estimation of muscle fiber conduction velocity
    • May
    • H. Broman, G. Bilotto, and C. J. De Luca, “A note on the noninvasive estimation of muscle fiber conduction velocity,” IEEE Trans. Biomed. Eng., vol. BME-32, pp. 341–344, May 1985.
    • (1985) IEEE Trans. Biomed. Eng. , vol.BME-32 , pp. 341-344
    • Broman, H.1    Bilotto, G.2    De Luca, C.J.3
  • 8
    • 0019999705 scopus 로고
    • A procedure for decomposing the myoelectric signal into its constituent action potentials—Part I: Technique, theory and implementation
    • R. S. LeFever and C. J. De Luca, “A procedure for decomposing the myoelectric signal into its constituent action potentials—Part I: Technique, theory and implementation,” IEEE Trans. Biomed. Eng., vol. BME-29, pp. 149–157, 1982.
    • (1982) IEEE Trans. Biomed. Eng. , vol.BME-29 , pp. 149-157
    • LeFever, R.S.1    De Luca, C.J.2
  • 9
    • 0017096701 scopus 로고
    • Techniques for improving the selectivity of electromyographic recordings
    • Nov.
    • I. Gath and E. V. Stalberg, “Techniques for improving the selectivity of electromyographic recordings,” IEEE Trans. Biomed. Eng., vol. BME-23, pp. 467–472, Nov. 1976.
    • (1976) IEEE Trans. Biomed. Eng. , vol.BME-23 , pp. 467-472
    • Gath, I.1    Stalberg, E.V.2
  • 10
    • 84946966312 scopus 로고
    • Experiments and models explaining the similarity in the shape of different muscle potentials
    • Munich, Germany, 1983, Electroenceph. Clin. Neurophysiol., Sept.
    • A. Gydikov, L. Gerilovski, N. Radicheva, and N. Trayanova, “Experiments and models explaining the similarity in the shape of different muscle potentials,” in Proc. 7th Int. Cong. EMG, Munich, Germany, 1983, Electroenceph. Clin. Neurophysiol., vol. 56, p. S94, Sept. 1983.
    • (1983) Proc. 7th Int. Cong. EMG , vol.56 , pp. S94
    • Gydikov, A.1    Gerilovski, L.2    Radicheva, N.3    Trayanova, N.4
  • 11
    • 0018477835 scopus 로고
    • Direct on-line estimation of muscle fiber conduction velocity by surface electromyography
    • Oct.
    • P. A. Lynn, “Direct on-line estimation of muscle fiber conduction velocity by surface electromyography,” IEEE Trans. Biomed. Eng., vol. BME-26, pp. 564–571, Oct. 1979.
    • (1979) IEEE Trans. Biomed. Eng. , vol.BME-26 , pp. 564-571
    • Lynn, P.A.1
  • 12
    • 0018366967 scopus 로고
    • The estimation of conduction velocity in human skeletal muscle in situ with surface electrodes
    • H. Nishizono, Y. Saito, and M. Miyashita, “The estimation of conduction velocity in human skeletal muscle in situ with surface electrodes,” Electroenceph. Clin. Neurophysiol., vol. 46, pp. 659–664, 1979.
    • (1979) Electroenceph. Clin. Neurophysiol. , vol.46 , pp. 659-664
    • Nishizono, H.1    Saito, Y.2    Miyashita, M.3
  • 13
    • 84946964347 scopus 로고
    • An improved non-invasive method for measurement of neuromuscular latencies
    • Ljubljana, June, in Zdrav Vestn, vol. 51, suppl. I, pp. 165–166.
    • H. Reucher, J. Silny, and G. Rau, “An improved non-invasive method for measurement of neuromuscular latencies,” in Proc. 5th Int. Cong. ISEK, Ljubljana, June 1982; in Zdrav Vestn, vol. 51, suppl. I, pp. 165–166.
    • (1982) Proc. 5th Int. Cong. ISEK
    • Reucher, H.1    Silny, J.2    Rau, G.3
  • 14
    • 84946968798 scopus 로고
    • Improved non-invasive determination of muscular stimulus response latencies
    • Hamburg, Germany
    • “Improved non-invasive determination of muscular stimulus response latencies,” in Proc. World Cong. Med. Phys. Biomed. Eng., Hamburg, Germany, 1982, p. 12.04.
    • (1982) Proc. World Cong. Med. Phys. Biomed. Eng. , pp. 12.04
  • 15
    • 0021321642 scopus 로고
    • Estimation of the spreading velocity and the parameters of the muscle potentials by averaging of the summated electromyogram
    • A. Gydikov, K. Kostov, A. Kossev, and D. Kosarov, “Estimation of the spreading velocity and the parameters of the muscle potentials by averaging of the summated electromyogram,” Electromyogr. Clin. Neurophysiol., vol. 24, pp. 191–212, 1984.
    • (1984) Electromyogr. Clin. Neurophysiol. , vol.24 , pp. 191-212
    • Gydikov, A.1    Kostov, K.2    Kossev, A.3    Kosarov, D.4
  • 16
    • 0342338493 scopus 로고
    • Median frequency of the myoelectric signal as a measure of localized muscular fatigue
    • Boston, MA
    • F. B. Stulen and C. J. De Luca, “Median frequency of the myoelectric signal as a measure of localized muscular fatigue,” in Proc. 4th Cong. ISEK, Boston, MA, 1979, pp. 92–93.
    • (1979) Proc. 4th Cong. ISEK , pp. 92-93
    • Stulen, F.B.1    De Luca, C.J.2
  • 17
    • 0017033138 scopus 로고
    • Volume conducted motor unit potentials in human muscle triceps surae
    • A. Gydikov, L. Gerilovski, and G. V. Dimitrov, “Volume conducted motor unit potentials in human muscle triceps surae,” Electromyogr. Clin. Neurophysiol., vol. 16, pp. 569–586, 1976.
    • (1976) Electromyogr. Clin. Neurophysiol. , vol.16 , pp. 569-586
    • Gydikov, A.1    Gerilovski, L.2    Dimitrov, G.V.3
  • 18
    • 0002535378 scopus 로고
    • Diagnostic value of electrical stimulation of motor nerves
    • suppl.
    • E. H. Lambert, “Diagnostic value of electrical stimulation of motor nerves,” Electroenceph. Clin. Neurophysiol., vol. 22 suppl., pp. 9–16, 1962.
    • (1962) Electroenceph. Clin. Neurophysiol. , vol.22 , pp. 9-16
    • Lambert, E.H.1
  • 20
    • 84944297001 scopus 로고
    • Nicht-invasive messtechnik zur Bestimmung neuromuskularer parameter unter Verwendung von multielektroden
    • Sept., suppl.
    • R. Warnking, J. Silny, and G. Rau, “Nicht-invasive messtechnik zur Bestimmung neuromuskularer parameter unter Verwendung von multielektroden,” Biomed. Technik, vol. 25 suppl., pp. 354–356, Sept. 1980.
    • (1980) Biomed. Technik , vol.25 , pp. 354-356
    • Warnking, R.1    Silny, J.2    Rau, G.3
  • 21
    • 84944438432 scopus 로고
    • Zuverlassige Verlaufskontrolle motorischer reizantwort-latenzen und nervenleitgeschwindigkeiten mittels neuer verfahren
    • suppl., Sept.
    • H. Reucher, J. Silny, and G. Rau, “Zuverlassige Verlaufskontrolle motorischer reizantwort-latenzen und nervenleitgeschwindigkeiten mittels neuer verfahren,” Biomed. Technik, vol. 29 suppl., pp. 149–150, Sept. 1984.
    • (1984) Biomed. Technik , vol.29 , pp. 149-150
    • Reucher, H.1    Silny, J.2    Rau, G.3
  • 22
    • 84946967818 scopus 로고
    • Proof of high long-term stability of motor nerve conduction velocity in normals
    • Dusseldorf, Germany, Oct., Electroenceph. Clin. Neurophysiol., vol. 63, p. 10P, 1986.
    • “Proof of high long-term stability of motor nerve conduction velocity in normals,” in Proc. 29th Annu. Meet. Deutsche EEG Gesellschaft, Dusseldorf, Germany, Oct. 1984, Electroenceph. Clin. Neurophysiol., vol. 63, p. 10P, 1986.
    • (1984) Proc. 29th Annu. Meet. Deutsche EEG Gesellschaft
  • 23
    • 0012059365 scopus 로고
    • Muscular activity and surface EMG
    • S. M. Perren and E. Schneider, Eds. The Netherlands: Nijhoff
    • G. Rau and H. Reucher, “Muscular activity and surface EMG,” in Biomechanics: Current Interdisciplinary Research, S. M. Perren and E. Schneider, Eds. The Netherlands: Nijhoff, 1985, pp. 27–35.
    • (1985) Biomechanics: Current Interdisciplinary Research , pp. 27-35
    • Rau, G.1    Reucher, H.2
  • 24
    • 84946968636 scopus 로고
    • Analysis of force tracking and EMG activities as a more detailed diagnostic tool for detecting neuromuscular disorders
    • Hamburg, Germany
    • “Analysis of force tracking and EMG activities as a more detailed diagnostic tool for detecting neuromuscular disorders,” in Proc. World Cong. Med. Phys. Biomed. Eng., Hamburg, Germany, 1982, p. 2.26.
    • (1982) Proc. World Cong. Med. Phys. Biomed. Eng. , pp. 2.26
  • 25
    • 0023289453 scopus 로고    scopus 로고
    • Spatial filtering of noninvasive multielectrode EMG: Part II—Filter performance in theory and modeling
    • this issue
    • H. Reucher, J. Silny, and G. Rau, “Spatial filtering of noninvasive multielectrode EMG: Part II—Filter performance in theory and modeling,” IEEE Trans. Biomed. Eng., this issue pp. 106–113.
    • IEEE Trans. Biomed. Eng. , pp. 106-113
    • Reucher, H.1    Silny, J.2    Rau, G.3
  • 26
    • 0001339236 scopus 로고
    • Surface electromyography in relation to force, muscle length and endurance
    • J. E. Desmedt, Ed. Basel, Switzerland: Karger
    • J. Vredenbregt and G. Rau, “Surface electromyography in relation to force, muscle length and endurance,” in New Developments in EMG and Clinical Neurophysiology, Vol. I, J. E. Desmedt, Ed. Basel, Switzerland: Karger 1973, pp. 607–622.
    • (1973) New Developments in EMG and Clinical Neurophysiology , vol.I , pp. 607-622
    • Vredenbregt, J.1    Rau, G.2
  • 28
    • 0018910685 scopus 로고
    • A system for the rapid acquisition of surface potential maps of human skeletal muscle motor units
    • Feb.
    • A. W. Monster, J. Pittore, and W. Barrie, “A system for the rapid acquisition of surface potential maps of human skeletal muscle motor units,” IEEE Trans. Biomed. Eng., vol. BME-27, pp. 110–112, Feb. 1980.
    • (1980) IEEE Trans. Biomed. Eng. , vol.BME-27 , pp. 110-112
    • Monster, A.W.1    Pittore, J.2    Barrie, W.3
  • 29
    • 0021892188 scopus 로고
    • The position of innervation zones in the biceps brachii investigated by surface electromyography
    • Jan.
    • T. Masuda, H. Miyano, and T. Sadoyama, “The position of innervation zones in the biceps brachii investigated by surface electromyography,” IEEE Trans. Biomed. Eng., vol. BME-32, pp. 36–42, Jan. 1985.
    • (1985) IEEE Trans. Biomed. Eng. , vol.BME-32 , pp. 36-42
    • Masuda, T.1    Miyano, H.2    Sadoyama, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.