메뉴 건너뛰기




Volumn 35, Issue 1, 1988, Pages 717-720

Development of 3-D detector system for positron CT

Author keywords

[No Author keywords available]

Indexed keywords

BIOMEDICAL ENGINEERING - COMPUTERIZED TOMOGRAPHY; COMPUTER SIMULATION; ELECTRON TUBES, PHOTOMULTIPLIER; GAMMA RAYS - ABSORPTION; SCINTILLATION COUNTERS;

EID: 84939007238     PISSN: 00189499     EISSN: 15581578     Source Type: Journal    
DOI: 10.1109/23.12818     Document Type: Article
Times cited : (44)

References (14)
  • 1
    • 0022667267 scopus 로고
    • Initial results from the Donner 600 crystal positron tomograph
    • S. E.Derenzo, R. H.Huesman, J. L.Cahoon, et al.,“Initial results from the Donner 600 crystal positron tomograph,” IEEE Trans Nucl Sci, NS-34(1), 321-325, 1987
    • (1987) IEEE Trans Nucl Sci. , vol.NS-34 , Issue.1 , pp. 321-325
    • Derenzo, S.E.1    Huesman, R.H.2    Cahoon, J.L.3
  • 2
    • 0021370469 scopus 로고
    • Development of a high resolution positron CT for animal studies
    • T. Tomitani, N. Nohara, H. Murayama, et al.,“Development of a high resolution positron CT for animal studies,” IEEE Trans Nucl Sci, NS-32, 822-825, 1985
    • (1985) IEEE Trans Nucl Sci. , vol.NS-32 , pp. 822-825
    • Tomitani, T.1    Nohara, N.2    Murayama, H.3
  • 3
    • 0022014541 scopus 로고
    • A multicrystal two dimensional BGO detector system for positron emission tomography
    • M.E.Cassey, R.Nutt, “A multicrystal two dimensional BGO detector system for positron emission tomography,” IEEE Trans Nucl Sci, NS-33, 460-463, 1966
    • (1966) IEEE Trans Nucl Sci. , vol.NS-33 , pp. 460-463
    • Cassey, M.E.1    Nutt, R.2
  • 5
    • 0020703469 scopus 로고
    • Initial characterization of a BGO-photodiode detector for high resolution positron emission tomography
    • S.E.Derenzo, “Initial characterization of a BGO-photodiode detector for high resolution positron emission tomography,” IEEE Trans Nucl Sci, NS-31, 620-626, 1984
    • (1984) IEEE Trans Nucl Sci. , vol.NS-31 , pp. 620-626
    • Derenzo, S.E.1
  • 6
    • 0142063683 scopus 로고
    • Designing a stratified detection system for PET cameras
    • W. H. Wong, “Designing a stratified detection system for PET cameras,”IEEE Trans Nucl Sci, NS-33, 591-596, 1986
    • (1986) IEEE Trans Nucl Sci. , vol.NS-33 , pp. 591-596
    • Wong, W.H.1
  • 7
    • 0022550290 scopus 로고
    • Design of an efficient position sensitive gamma ray detector for nuclear medicine
    • J.G.Rogers, D.P.Saylor, R.Harrop, et al., “Design of an efficient position sensitive gamma ray detector for nuclear medicine,” Phys Med Biol, Vol.31, 1061-1090, 1986 1090, 1986
    • (1986) Phys Med Biol , vol.31 , pp. 1061-1090
    • Rogers, J.G.1    Saylor, D.P.2    Harrop, R.3
  • 8
    • 0023426484 scopus 로고
    • Determination of depth-of-interaction in scintillation crystals using a temperature gradient
    • J.S.Karp, M.E.Daube-Witherspoon, “Determination of depth-of-interaction in scintillation crystals using a temperature gradient,” Nucl Inst and Meth, A260, 509-517, 1987
    • (1987) Nucl Inst and Meth. , vol.A260 , pp. 509-517
    • Karp, J.S.1    Daube-Witherspoon, M.E.2
  • 9
    • 0021517269 scopus 로고
    • On the use of tapered Bismuth Germanate crystals in positron emission tomography
    • L. R. Lupton, N. A. Keller, C. J. Thompson, L. L. Anderson,” On the use of tapered Bismuth Germanate crystals in positron emission tomography,” Nucl Inst and Meth, 227, 361-368, 1984
    • (1984) Nucl Inst and Meth. , vol.227 , pp. 361-368
    • Lupton, L.R.1    Keller, N.A.2    Thompson, C.J.3    Anderson, L.L.4
  • 10
    • 0000876408 scopus 로고
    • Position sensitive photomultiplier tomultiplier tubes for scintillation imaging
    • H.Kume, S.Muramatsu, M.Iida, “Position sensitive photomultiplier tomultiplier tubes for scintillation imaging,” IEEE Trans Nucl Sci, NS-33, 359-363, 1986
    • (1986) IEEE Trans Nucl Sci. , vol.NS-33 , pp. 359-363
    • Kume, H.1    Muramatsu, S.2    Iida, M.3
  • 12
    • 0019579652 scopus 로고
    • A large position sensitive neutron detector
    • P.Netter, L.Lassen, R.Schreek,“A large position sensitive neutron detector,” Nucl Inst and Meth, 185, 165-174, 1981
    • (1981) Nucl Inst and Meth. , vol.185 , pp. 165-174
    • Netter, P.1    Lassen, L.2    Schreek, R.3
  • 13
    • 0003462953 scopus 로고    scopus 로고
    • Detection, estimation and modulation theory
    • New York: John Wiley and Sons Inc
    • H. L. Van Trees,”Detection, estimation and modulation theory, “New York:John Wiley and Sons Inc.
    • Van Trees, H.L.1
  • 14
    • 0020703335 scopus 로고
    • A modular scintillation camera for use in nuclear medicine
    • T.D.Milster, L.A.Selberg, H.H.Barrett, et al.,“A modular scintillation camera for use in nuclear medicine,” IEEE Trans Nucl Sci, NS-31, 578-560, 1984
    • (1984) IEEE Trans Nucl Sci. , vol.NS-31 , pp. 560-578
    • Milster, T.D.1    Selberg, L.A.2    Barrett, H.H.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.