메뉴 건너뛰기




Volumn 33, Issue 4, 2015, Pages 755-762

Accuracy of self-monitored blood pressure for diagnosing hypertension in primary care

Author keywords

Diagnosis; Hypertension; Primary care; Selfmonitoring; Sensitivity; Specificity

Indexed keywords

ADULT; AGED; BLOOD PRESSURE MONITORING; BLUETOOTH; CONFERENCE PAPER; CROSS-SECTIONAL STUDY; DIAGNOSTIC ACCURACY; GENERAL PRACTITIONER; HUMAN; HYPERTENSION; MAJOR CLINICAL STUDY; PRACTICE GUIDELINE; PREDICTIVE VALUE; PRIMARY MEDICAL CARE; PRIORITY JOURNAL; PROSPECTIVE STUDY; REMOTE SENSING; SELF MONITORING; SENSITIVITY AND SPECIFICITY; SYSTOLIC BLOOD PRESSURE; TELEMONITORING; UNITED KINGDOM; VERY ELDERLY; WIRELESS COMMUNICATION; BLOOD PRESSURE; BLOOD PRESSURE MEASUREMENT; COHORT ANALYSIS; FEMALE; MALE; MIDDLE AGED; PRIMARY HEALTH CARE; SELF CARE; STANDARDS;

EID: 84938920264     PISSN: 02636352     EISSN: 14735598     Source Type: Journal    
DOI: 10.1097/HJH.0000000000000489     Document Type: Conference Paper
Times cited : (24)

References (47)
  • 2
    • 0037079309 scopus 로고    scopus 로고
    • Age-specific relevance of usual blood pressure to vascular mortality: A meta-analysis of individual data for one million adults in 61 prospective studies
    • Lewington S, Clarke R, Qizilbash N, Peto R, Collins R. Age-specific relevance of usual blood pressure to vascular mortality: a meta-analysis of individual data for one million adults in 61 prospective studies. Lancet 2002; 360:1903-1913.
    • (2002) Lancet , vol.360 , pp. 1903-1913
    • Lewington, S.1    Clarke, R.2    Qizilbash, N.3    Peto, R.4    Collins, R.5
  • 4
    • 39849104015 scopus 로고    scopus 로고
    • Attitudes of primary care physicians and their patients about home blood pressure monitoring in Ontario
    • Logan AG, Dunai A, McIsaac WJ, Irvine MJ, Tisler A. Attitudes of primary care physicians and their patients about home blood pressure monitoring in Ontario. J Hypertens 2008; 26:446-452.
    • (2008) J Hypertens , vol.26 , pp. 446-452
    • Logan, A.G.1    Dunai, A.2    McIsaac, W.J.3    Irvine, M.J.4    Tisler, A.5
  • 5
    • 84868267009 scopus 로고    scopus 로고
    • Selfmonitoring of blood pressure in hypertension: A UK primary care survey
    • Baral-Grant S, Haque MS, Nouwen A, Greenfield S, McManus R. Selfmonitoring of blood pressure in hypertension: a UK primary care survey. Int J Hypertens 2012; 2012:582068.
    • (2012) J Hypertens , vol.2012 , pp. 582068
    • Baral-Grant, S.1    Haque, M.S.2    Nouwen, A.3    Greenfield, S.4    McManus, R.5
  • 6
    • 0030744133 scopus 로고    scopus 로고
    • Reproducibility of home blood pressure measurements over a 1-year period
    • Sakuma M, Imai Y, Nagai K, Watanabe N, Sakuma H, Minami N, et al. Reproducibility of home blood pressure measurements over a 1-year period. Am J Hypertens 1997; 10:798-803.
    • (1997) Am J Hypertens , vol.10 , pp. 798-803
    • Sakuma, M.1    Imai, Y.2    Nagai, K.3    Watanabe, N.4    Sakuma, H.5    Minami, N.6
  • 7
    • 80555149883 scopus 로고    scopus 로고
    • Relative effectiveness of clinic and home blood pressure monitoring compared with ambulatory blood pressure monitoring in diagnosis of hypertension: Systematic review
    • Hodgkinson J, Mant J, Martin U, Guo B, Hobbs FD, Deeks JJ, et al. Relative effectiveness of clinic and home blood pressure monitoring compared with ambulatory blood pressure monitoring in diagnosis of hypertension: systematic review. BMJ 2011; 342:d3621.
    • (2011) BMJ , vol.342 , pp. d3621
    • Hodgkinson, J.1    Mant, J.2    Martin, U.3    Guo, B.4    Hobbs, F.D.5    Deeks, J.J.6
  • 8
    • 84869498992 scopus 로고    scopus 로고
    • Home versus ambulatory blood pressure monitoring in the diagnosis of clinic resistant and true resistant hypertension
    • Nasothimiou EG, Tzamouranis D, Roussias LG, Stergiou GS. Home versus ambulatory blood pressure monitoring in the diagnosis of clinic resistant and true resistant hypertension. J Hum Hypertens 2012; 26:696-700.
    • (2012) J Hum Hypertens , vol.26 , pp. 696-700
    • Nasothimiou, E.G.1    Tzamouranis, D.2    Roussias, L.G.3    Stergiou, G.S.4
  • 9
    • 84857056937 scopus 로고    scopus 로고
    • Home measurement of blood pressure and cardiovascular disease: Systematic review and meta-analysis of prospective studies
    • Ward AM, Takahashi O, Stevens R, Heneghan C. Home measurement of blood pressure and cardiovascular disease: systematic review and meta-analysis of prospective studies. J Hypertens 2012; 30:449-456.
    • (2012) J Hypertens , vol.30 , pp. 449-456
    • Ward, A.M.1    Takahashi, O.2    Stevens, R.3    Heneghan, C.4
  • 10
    • 70449851433 scopus 로고    scopus 로고
    • Reappraisal of European guidelines on hypertension management: A European Society of Hypertension Task Force document
    • Mancia G, Laurent S, Agabiti-Rosei E, Ambrosioni E, Burnier M, Caulfield MJ, et al. Reappraisal of European guidelines on hypertension management: a European Society of Hypertension Task Force document. J Hypertens 2009; 27:2121-2158.
    • (2009) J Hypertens , vol.27 , pp. 2121-2158
    • Mancia, G.1    Laurent, S.2    Agabiti-Rosei, E.3    Ambrosioni, E.4    Burnier, M.5    Caulfield, M.J.6
  • 11
    • 77952304034 scopus 로고    scopus 로고
    • The Japanese society of hypertension guidelines for the management of hypertension (jsh 2009)
    • Ogihara T, Kikuchi K, Matsuoka H, Fujita T, Higaki J, Horiuchi M, et al. The Japanese Society of Hypertension Guidelines for the Management of Hypertension (JSH 2009). Hypertens Res 2009; 32:3-107.
    • (2009) Hypertens Res , vol.32 , pp. 3-107
    • Ogihara, T.1    Kikuchi, K.2    Matsuoka, H.3    Fujita, T.4    Higaki, J.5    Horiuchi, M.6
  • 13
    • 80052400714 scopus 로고    scopus 로고
    • The 2011 canadian hypertension education program recommendations for the management of hypertension: Blood pressure measurement, diagnosis, assessment of risk, and therapy
    • e1-2
    • Rabi DM, Daskalopoulou SS, Padwal RS, Khan NA, Grover SA, Hackam DG, et al. The 2011 Canadian Hypertension Education Program recommendations for the management of hypertension: blood pressure measurement, diagnosis, assessment of risk, and therapy. Can J Cardiol 2011; 27:415-433; e1-2.
    • (2011) Can J Cardiol , vol.27 , pp. 415-433
    • Rabi, D.M.1    Daskalopoulou, S.S.2    Padwal, R.S.3    Khan, N.A.4    Grover, S.A.5    Hackam, D.G.6
  • 15
    • 51549098043 scopus 로고    scopus 로고
    • European society of hypertension guidelines for blood pressure monitoring at home: A summary report of the second international consensus conference on home blood pressure monitoring
    • Parati G, Stergiou GS, Asmar R, Bilo G, de Leeuw P, Imai Y, et al. European Society of Hypertension guidelines for blood pressure monitoring at home: a summary report of the Second International Consensus Conference on Home Blood Pressure Monitoring. J Hypertens 2008; 26:1505-1526.
    • (2008) J Hypertens , vol.26 , pp. 1505-1526
    • Parati, G.1    Stergiou, G.S.2    Asmar, R.3    Bilo, G.4    De Leeuw, P.5    Imai, Y.6
  • 16
    • 43949091587 scopus 로고    scopus 로고
    • Call to action on use and reimbursement for home blood pressure monitoring: A joint scientific statement from the American Heart Association, american society of hypertension, and preventive cardiovascular nurses association
    • Pickering TG, Miller NH, Ogedegbe G, Krakoff LR, Artinian NT, Goff D. Call to action on use and reimbursement for home blood pressure monitoring: a joint scientific statement from the American Heart Association, American Society Of Hypertension, and Preventive Cardiovascular Nurses Association. Hypertension 2008; 52:10-29.
    • (2008) Hypertension , vol.52 , pp. 10-29
    • Pickering, T.G.1    Miller, N.H.2    Ogedegbe, G.3    Krakoff, L.R.4    Artinian, N.T.5    Goff, D.6
  • 17
    • 84893549987 scopus 로고    scopus 로고
    • Evidence-based guideline for the management of high blood pressure in adults: Report from the panel members appointed to the eighth joint national committee (jnc 8)
    • James PA, Oparil S, Carter BL, Cushman WC, Dennison-Himmelfarb C, Handler J, et al. Evidence-based guideline for the management of high blood pressure in adults: report from the panel members appointed to the Eighth Joint National Committee (JNC 8). JAMA 2014; 311:507-520.
    • (2014) JAMA , vol.311 , pp. 507-520
    • James, P.A.1    Oparil, S.2    Carter, B.L.3    Cushman, W.C.4    Dennison-Himmelfarb, C.5    Handler, J.6
  • 19
    • 84880930315 scopus 로고    scopus 로고
    • 2013 ESH/ESC guidelines for the management of arterial hypertension: The task force for the management of arterial hypertension of the european society of hypertension (ESH) and of the european society of cardiology (ESC)
    • Mancia G, Fagard R, Narkiewicz K, Redon J, Zanchetti A, Bohm M, et al. 2013 ESH/ESC guidelines for the management of arterial hypertension: the Task Force for the Management of Arterial Hypertension of the European Society of Hypertension (ESH) and of the European Society of Cardiology (ESC). Eur Heart J 2013; 34:2159-2219.
    • (2013) Eur Heart J , vol.34 , pp. 2159-2219
    • Mancia, G.1    Fagard, R.2    Narkiewicz, K.3    Redon, J.4    Zanchetti, A.5    Bohm, M.6
  • 20
    • 0031861524 scopus 로고    scopus 로고
    • Self-monitoring of blood pressure at home: How many measurements are needed
    • Stergiou GS, Skeva II, Zourbaki AS, Mountokalakis TD. Self-monitoring of blood pressure at home: how many measurements are needed? J Hypertens 1998; 16:725-731.
    • (1998) J Hypertens , vol.16 , pp. 725-731
    • Stergiou, G.S.1    Skeva, I.I.2    Zourbaki, A.S.3    Mountokalakis, T.D.4
  • 21
    • 0033932377 scopus 로고    scopus 로고
    • User procedure for self-measurement of blood pressure first international consensus conference on self blood pressure measurement
    • Mengden T, Chamontin B, Phong Chau N, Luis Palma Gamiz J, Chanudet X. User procedure for self-measurement of blood pressure. First International Consensus Conference on Self Blood Pressure Measurement. Blood Press Monit 2000; 5:111-129.
    • (2000) Blood Press Monit , vol.5 , pp. 111-129
    • Mengden, T.1    Chamontin, B.2    Phong, C.N.3    Luis, P.G.J.4    Chanudet, X.5
  • 22
    • 0033930905 scopus 로고    scopus 로고
    • Home blood pressure: Accuracy is independent of monitoring schedules
    • Brook RD. Home blood pressure: accuracy is independent of monitoring schedules. Am J Hypertens 2000; 13:625-631.
    • (2000) Am J Hypertens , vol.13 , pp. 625-631
    • Brook, R.D.1
  • 23
  • 24
    • 78650406561 scopus 로고    scopus 로고
    • Role of home blood pressure telemonitoring in hypertension management: An update
    • Parati G, Omboni S. Role of home blood pressure telemonitoring in hypertension management: an update. Blood Press Monit 2010; 15:285-295.
    • (2010) Blood Press Monit , vol.15 , pp. 285-295
    • Parati, G.1    Omboni, S.2
  • 25
    • 78751640783 scopus 로고    scopus 로고
    • Home blood pressure monitoring in the diagnosis and treatment of hypertension: A systematic review
    • Stergiou GS, Bliziotis IA. Home blood pressure monitoring in the diagnosis and treatment of hypertension: a systematic review. Am J Hypertens 2011; 24:123-134.
    • (2011) Am J Hypertens , vol.24 , pp. 123-134
    • Stergiou, G.S.1    Bliziotis, I.A.2
  • 26
    • 77951065502 scopus 로고    scopus 로고
    • Differences in clinic and ambulatory measurements of blood pressure
    • McManus R, Martin U. Differences in clinic and ambulatory measurements of blood pressure. BMJ 2010; 340:c1782.
    • (2010) BMJ , vol.340 , pp. c1782
    • McManus, R.1    Martin, U.2
  • 27
    • 79960969699 scopus 로고    scopus 로고
    • Home blood pressure management and improved blood pressure control: Results from a randomized controlled trial
    • Bosworth HB, Powers BJ, Olsen MK, McCant F, Grubber J, Smith V, et al. Home blood pressure management and improved blood pressure control: results from a randomized controlled trial. Arch Intern Med 2011; 171:1173-1180.
    • (2011) Arch Intern Med , vol.171 , pp. 1173-1180
    • Bosworth, H.B.1    Powers, B.J.2    Olsen, M.K.3    McCant, F.4    Grubber, J.5    Smith, V.6
  • 28
    • 84865812296 scopus 로고    scopus 로고
    • Effect of home blood pressure telemonitoring with self-care support on uncontrolled systolic hypertension in diabetics
    • Logan AG, Irvine MJ, McIsaac WJ, Tisler A, Rossos PG, Easty A, et al. Effect of home blood pressure telemonitoring with self-care support on uncontrolled systolic hypertension in diabetics. Hypertension 2012; 60:51-57.
    • (2012) Hypertension , vol.60 , pp. 51-57
    • Logan, A.G.1    Irvine, M.J.2    McIsaac, W.J.3    Tisler, A.4    Rossos, P.G.5    Easty, A.6
  • 29
    • 84863795902 scopus 로고    scopus 로고
    • Effect of telehealth on use of secondary care and mortality: Findings from the Whole System Demonstrator cluster randomised trial
    • Steventon A, Bardsley M, Billings J, Dixon J, Hirani S, Cartwright M, et al. Effect of telehealth on use of secondary care and mortality: findings from the Whole System Demonstrator cluster randomised trial. BMJ 2012; 344:e3874.
    • (2012) BMJ , vol.344 , pp. e3874
    • Steventon, A.1    Bardsley, M.2    Billings, J.3    Dixon, J.4    Hirani, S.5    Cartwright, M.6
  • 31
    • 39449107158 scopus 로고    scopus 로고
    • Validation of the Stabil-O-Graph blood pressure self-measurement device
    • Westhoff TH, Schmidt S, Zidek W, van der Giet M. Validation of the Stabil-O-Graph blood pressure self-measurement device. J Hum Hypertens 2008; 22:233-235.
    • (2008) J Hum Hypertens , vol.22 , pp. 233-235
    • Westhoff, T.H.1    Schmidt, S.2    Zidek, W.3    Van Der Giet, M.4
  • 32
    • 0038460302 scopus 로고    scopus 로고
    • The seventh report of the joint national committee on prevention, detection, evaluation, and treatment of high blood pressure: The jnc 7 report
    • Chobanian AV, Bakris GL, Black HR, Cushman WC, Green LA, Izzo JL Jr, et al. The Seventh Report of the Joint National Committee on Prevention, Detection, Evaluation, and Treatment of High Blood Pressure: the JNC 7 report. JAMA 2003; 289:2560-2572.
    • (2003) JAMA , vol.289 , pp. 2560-2572
    • Chobanian, A.V.1    Bakris, G.L.2    Black, H.R.3    Cushman, W.C.4    Green, L.A.5    Izzo, J.L.6
  • 33
    • 1542432170 scopus 로고    scopus 로고
    • Guidelines for management of hypertension: Report of the fourth working party of the British Hypertension Society, 2004-BHS IV
    • Williams B, Poulter NR, Brown MJ, Davis MJ, McInnes GT, Potter JF, et al. Guidelines for management of hypertension: report of the fourth working party of the British Hypertension Society, 2004-BHS IV. J Hum Hypertens 2004; 18:139-185.
    • (2004) J Hum Hypertens , vol.18 , pp. 139-185
    • Williams, B.1    Poulter, N.R.2    Brown, M.J.3    Davis, M.J.4    McInnes, G.T.5    Potter, J.F.6
  • 34
    • 76449093635 scopus 로고    scopus 로고
    • Validation of the microlife watchbp o3 device for clinic, home, and ambulatory blood pressure measurement, according to the international protocol
    • Ragazzo F, Saladini F, Palatini P. Validation of the Microlife WatchBP O3 device for clinic, home, and ambulatory blood pressure measurement, according to the International Protocol. Blood Press Monit 2010; 15:59-62.
    • (2010) Blood Press Monit , vol.15 , pp. 59-62
    • Ragazzo, F.1    Saladini, F.2    Palatini, P.3
  • 35
    • 84860140958 scopus 로고    scopus 로고
    • The NHS Information Centre Prescribing and Primary Care Services Version 1.0, 20 October
    • The NHS Information Centre Prescribing and Primary Care Services. Quality and outcomes framework achievement data 2009/10. Version 1.0, 20 October 2010. http://www.hscic.gov.uk/catalogue/PUB04431/ qof-09-10-rep.pdf.
    • (2010) Quality and Outcomes Framework Achievement Data 2009/10
  • 36
    • 79251524198 scopus 로고    scopus 로고
    • Manual and automated office measurements in relation to awake ambulatory blood pressure monitoring
    • Godwin M, Birtwhistle R, Delva D, Lam M, Casson I, MacDonald S, et al. Manual and automated office measurements in relation to awake ambulatory blood pressure monitoring. Fam Pract 2011; 28:110-117.
    • (2011) Fam Pract , vol.28 , pp. 110-117
    • Godwin, M.1    Birtwhistle, R.2    Delva, D.3    Lam, M.4    Casson, I.5    MacDonald, S.6
  • 37
    • 0023221489 scopus 로고
    • Changing relation between home and clinic blood-pressure measurements: Do home measurements predict clinic hypertension
    • Padfield PL, Lindsay BA, McLaren JA, Pirie A, Rademaker M. Changing relation between home and clinic blood-pressure measurements: do home measurements predict clinic hypertension? Lancet 1987; 2:322-324.
    • (1987) Lancet , vol.2 , pp. 322-324
    • Padfield, P.L.1    Lindsay, B.A.2    McLaren, J.A.3    Pirie, A.4    Rademaker, M.5
  • 38
    • 0041589779 scopus 로고    scopus 로고
    • Accuracy of telemedical home blood pressure measurement in the diagnosis of hypertension
    • Moller DS, Dideriksen A, Sorensen S, Madsen LD, Pederson EB. Accuracy of telemedical home blood pressure measurement in the diagnosis of hypertension. J Hum Hypertens 2003; 17:549-554.
    • (2003) J Hum Hypertens , vol.17 , pp. 549-554
    • Moller, D.S.1    Dideriksen, A.2    Sorensen, S.3    Madsen, L.D.4    Pederson, E.B.5
  • 39
    • 78751640783 scopus 로고    scopus 로고
    • Home blood pressure monitoring in the diagnosis and treatment of hypertension: A systematic review
    • Stergiou GS, Bliziotis IA. Home blood pressure monitoring in the diagnosis and treatment of hypertension: a systematic review. Am J Hypertens 2010; 24:123-134.
    • (2010) Am J Hypertens , vol.24 , pp. 123-134
    • Stergiou, G.S.1    Bliziotis, I.A.2
  • 40
    • 0027725179 scopus 로고
    • Characteristics of a community-based distribution of home blood pressure in Ohasama in northern Japan
    • Imai Y, Satoh H, Nagai K, Sakuma M, Sakuma H, Minami N, et al. Characteristics of a community-based distribution of home blood pressure in Ohasama in northern Japan. J Hypertens 1993; 11:1441-1449.
    • (1993) J Hypertens , vol.11 , pp. 1441-1449
    • Imai, Y.1    Satoh, H.2    Nagai, K.3    Sakuma, M.4    Sakuma, H.5    Minami, N.6
  • 41
    • 0028023031 scopus 로고
    • Home blood pressure: Variability, comparison with office readings and proposal for reference values groupe de la mesure, French society of hypertension
    • de Gaudemaris R, Chau NP, Mallion JM. Home blood pressure: variability, comparison with office readings and proposal for reference values. Groupe de la Mesure, French Society of Hypertension. J Hypertens 1994; 12:831-838.
    • (1994) J Hypertens , vol.12 , pp. 831-838
    • De Gaudemaris, R.1    Chau, N.P.2    Mallion, J.M.3
  • 42
    • 0033664125 scopus 로고    scopus 로고
    • Diagnosis of hypertension using home or ambulatory blood pressure monitoring: Comparison with the conventional strategy based on repeated clinic blood pressure measurements
    • Stergiou GS, Skeva II, Baibas NM, Kalkana CB, Roussias LG, Mountokalakis TD. Diagnosis of hypertension using home or ambulatory blood pressure monitoring: comparison with the conventional strategy based on repeated clinic blood pressure measurements. J Hypertens 2000; 18:1745-1751.
    • (2000) J Hypertens , vol.18 , pp. 1745-1751
    • Stergiou, G.S.1    Skeva, I.I.2    Baibas, N.M.3    Kalkana, C.B.4    Roussias, L.G.5    Mountokalakis, T.D.6
  • 43
    • 84874937193 scopus 로고    scopus 로고
    • Improved diagnostic accuracy of a 3-day protocol of home blood pressure monitoring for the diagnosis of arterial hypertension
    • Almeida AE, Stein R, Gus M, Nascimento JA, Arevalo JR, Fuchs FD, et al. Improved diagnostic accuracy of a 3-day protocol of home blood pressure monitoring for the diagnosis of arterial hypertension. Blood Press Monit 2013; 18:119-126.
    • (2013) Blood Press Monit , vol.18 , pp. 119-126
    • Almeida, A.E.1    Stein, R.2    Gus, M.3    Nascimento, J.A.4    Arevalo, J.R.5    Fuchs, F.D.6
  • 44
    • 0032874699 scopus 로고    scopus 로고
    • Guidelines for management of hypertension: Report of the third working party of the British Hypertension Society
    • Ramsay L, Williams B, Johnston G, MacGregor GA, Poston L, Potter JF, et al. Guidelines for management of hypertension: report of the third working party of the British Hypertension Society. J Hum Hypertens 1999; 13:569-592.
    • (1999) J Hum Hypertens , vol.13 , pp. 569-592
    • Ramsay, L.1    Williams, B.2    Johnston, G.3    MacGregor, G.A.4    Poston, L.5    Potter, J.F.6
  • 45
    • 68949136922 scopus 로고    scopus 로고
    • Why is out-of-office blood pressure measurement needed? Home blood pressure measurements will increasingly replace ambulatory blood pressure monitoring in the diagnosis and management of hypertension
    • Parati G, Omboni S, Bilo G. Why is out-of-office blood pressure measurement needed? Home blood pressure measurements will increasingly replace ambulatory blood pressure monitoring in the diagnosis and management of hypertension. Hypertension 2009; 54:181-187.
    • (2009) Hypertension , vol.54 , pp. 181-187
    • Parati, G.1    Omboni, S.2    Bilo, G.3
  • 46
    • 84864911830 scopus 로고    scopus 로고
    • Conventional versus automated measurement of blood pressure in the office (CAMBO) trial
    • Myers MG, Godwin M, Dawes M, Kiss A, Tobe SW, Kaczorowski J. Conventional versus automated measurement of blood pressure in the office (CAMBO) trial. Fam Pract 2012; 29:376-382.
    • (2012) Fam Pract , vol.29 , pp. 376-382
    • Myers, M.G.1    Godwin, M.2    Dawes, M.3    Kiss, A.4    Tobe, S.W.5    Kaczorowski, J.6
  • 47
    • 84872579591 scopus 로고    scopus 로고
    • A systematic review of recent clinical practice guidelines on the diagnosis, assessment and management of hypertension
    • Al-Ansary LA, Tricco AC, Adi Y, Bawazeer G, Perrier L, Al-Ghonaim M, et al. A systematic review of recent clinical practice guidelines on the diagnosis, assessment and management of hypertension. PLoS One 2013; 8:e53744.
    • (2013) PLoS One , vol.8 , pp. e53744
    • Al-Ansary, L.A.1    Tricco, A.C.2    Adi, Y.3    Bawazeer, G.4    Perrier, L.5    Al-Ghonaim, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.