메뉴 건너뛰기




Volumn 23, Issue 4, 2016, Pages 680-689

Outcomes after inappropriate nuclear myocardial perfusion imaging: A meta-analysis

Author keywords

ischemia; myocardial; Myocardial perfusion imaging; PET; SPECT

Indexed keywords

AREA UNDER THE CURVE; ARTICLE; HEART CATHETERIZATION; HEART INFARCTION; HEART MUSCLE ISCHEMIA; HEART MUSCLE REVASCULARIZATION; HUMAN; META ANALYSIS; MORTALITY; MYOCARDIAL PERFUSION IMAGING; OUTCOME ASSESSMENT; PRIORITY JOURNAL; AGED; CLINICAL TRIAL; DIAGNOSTIC ERROR; FEMALE; MALE; MEDLINE; MIDDLE AGED; MULTICENTER STUDY; PREVALENCE; PREVENTION AND CONTROL; REPRODUCIBILITY; RISK FACTOR; SENSITIVITY AND SPECIFICITY; SINGLE PHOTON EMISSION COMPUTED TOMOGRAPHY; STATISTICS AND NUMERICAL DATA; TRENDS; UNNECESSARY PROCEDURE; UTILIZATION; UTILIZATION REVIEW;

EID: 84938809367     PISSN: 10713581     EISSN: 15326551     Source Type: Journal    
DOI: 10.1007/s12350-015-0240-2     Document Type: Article
Times cited : (27)

References (53)
  • 1
    • 70350492038 scopus 로고    scopus 로고
    • Noninvasive assessment of myocardial perfusion
    • PID: 19808630
    • Salerno M, Beller GA. Noninvasive assessment of myocardial perfusion. Circ Cardiovasc Imaging 2009;2:412-24.
    • (2009) Circ Cardiovasc Imaging , vol.2 , pp. 412-424
    • Salerno, M.1    Beller, G.A.2
  • 2
    • 3242892147 scopus 로고    scopus 로고
    • Diagnosis of coronary artery disease by radionuclide myocardial perfusion imaging
    • PID: 15254003
    • Loong CY, Anagnostopoulos C. Diagnosis of coronary artery disease by radionuclide myocardial perfusion imaging. Heart 2004;90:v2-9.
    • (2004) Heart , vol.90 , pp. v2-v9
    • Loong, C.Y.1    Anagnostopoulos, C.2
  • 3
    • 65949094604 scopus 로고    scopus 로고
    • Recent payment and utilization trends in radionuclide myocardial perfusion imaging: Comparison between self-referral and referral to radiologists
    • PID: 19467490
    • Levin DC, Rao VM, Parker L, Frangos AJ, Intenzo CM. Recent payment and utilization trends in radionuclide myocardial perfusion imaging: Comparison between self-referral and referral to radiologists. J Am Coll Radiol 2009;6:437-41.
    • (2009) J Am Coll Radiol , vol.6 , pp. 437-441
    • Levin, D.C.1    Rao, V.M.2    Parker, L.3    Frangos, A.J.4    Intenzo, C.M.5
  • 4
    • 33644857761 scopus 로고    scopus 로고
    • Temporal trends in the utilization of diagnostic testing and treatments for cardiovascular disease in the United States, 1993-2001
    • COI: 1:STN:280:DC%2BD28%2Fkt1yksA%3D%3D, PID: 16432068
    • Lucas FL, DeLorenzo MA, Siewers AE, Wennberg DE. Temporal trends in the utilization of diagnostic testing and treatments for cardiovascular disease in the United States, 1993-2001. Circulation 2006;113:374-9.
    • (2006) Circulation , vol.113 , pp. 374-379
    • Lucas, F.L.1    DeLorenzo, M.A.2    Siewers, A.E.3    Wennberg, D.E.4
  • 5
    • 84896626691 scopus 로고    scopus 로고
    • Population trends from 2000-2011 in nuclear myocardial perfusion imaging use
    • COI: 1:CAS:528:DC%2BC2cXlvVeqsbw%3D, PID: 24668108
    • McNulty EJ, Hung Y, Almers LM, Go AS, Yeh RW. Population trends from 2000-2011 in nuclear myocardial perfusion imaging use. JAMA 2014;311:1248-9.
    • (2014) JAMA , vol.311 , pp. 1248-1249
    • McNulty, E.J.1    Hung, Y.2    Almers, L.M.3    Go, A.S.4    Yeh, R.W.5
  • 6
    • 41449107506 scopus 로고    scopus 로고
    • Utilization management of cardiovascular imaging: Pre-certification and appropriateness
    • PID: 19356433
    • Hendel RC. Utilization management of cardiovascular imaging: Pre-certification and appropriateness. JACC Cardiovasc Imaging 2008;1:241-8.
    • (2008) JACC Cardiovasc Imaging , vol.1 , pp. 241-248
    • Hendel, R.C.1
  • 7
    • 61849144428 scopus 로고    scopus 로고
    • The new era of medical imaging—progress and pitfalls
    • COI: 1:CAS:528:DC%2BD1MXislygsrw%3D, PID: 19264694
    • Iglehart JK. The new era of medical imaging—progress and pitfalls. N Engl J Med 2009;360:1030-7.
    • (2009) N Engl J Med , vol.360 , pp. 1030-1037
    • Iglehart, J.K.1
  • 8
    • 26844552946 scopus 로고    scopus 로고
    • ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association
    • PID: 16226194
    • Brindis RG, Douglas PS, Hendel RC, Peterson ED, Wolk MJ, Allen JM, et al. ACCF/ASNC appropriateness criteria for single-photon emission computed tomography myocardial perfusion imaging (SPECT MPI): A report of the American College of Cardiology Foundation Quality Strategic Directions Committee Appropriateness Criteria Working Group and the American Society of Nuclear Cardiology endorsed by the American Heart Association. J Am Coll Cardiol 2005;46:1587-605.
    • (2005) J Am Coll Cardiol , vol.46 , pp. 1587-1605
    • Brindis, R.G.1    Douglas, P.S.2    Hendel, R.C.3    Peterson, E.D.4    Wolk, M.J.5    Allen, J.M.6
  • 9
    • 67649619857 scopus 로고    scopus 로고
    • ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine
    • PID: 19451357
    • Hendel RC, Berman DS, Di Carli MF, Heidenreich PA, Henkin RE, Pellikka PA, et al. ACCF/ASNC/ACR/AHA/ASE/SCCT/SCMR/SNM 2009 appropriate use criteria for cardiac radionuclide imaging: A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, the American Society of Nuclear Cardiology, the American College of Radiology, the American Heart Association, the American Society of Echocardiography, the Society of Cardiovascular Computed Tomography, the Society for Cardiovascular Magnetic Resonance, and the Society of Nuclear Medicine. Circulation 2009;119:e561-87.
    • (2009) Circulation , vol.119 , pp. e561-e587
    • Hendel, R.C.1    Berman, D.S.2    Di Carli, M.F.3    Heidenreich, P.A.4    Henkin, R.E.5    Pellikka, P.A.6
  • 10
    • 84925481766 scopus 로고    scopus 로고
    • Myocardial perfusion imaging determination using an appropriate use smartphone application
    • PID: 25273671
    • Mahajan A, Bal S, Hahn H. Myocardial perfusion imaging determination using an appropriate use smartphone application. J Nucl Cardiol 2015;22:66-71.
    • (2015) J Nucl Cardiol , vol.22 , pp. 66-71
    • Mahajan, A.1    Bal, S.2    Hahn, H.3
  • 12
    • 84901651035 scopus 로고    scopus 로고
    • Clinician-dependent variations in inappropriate use of myocardial perfusion imaging: Training, specialty, and location
    • PID: 24671699
    • Winchester DE, Hymas J, Meral R, Nguyen D, Dusaj R, Shaw LJ, et al. Clinician-dependent variations in inappropriate use of myocardial perfusion imaging: Training, specialty, and location. J Nucl Cardiol 2014;21:598-604.
    • (2014) J Nucl Cardiol , vol.21 , pp. 598-604
    • Winchester, D.E.1    Hymas, J.2    Meral, R.3    Nguyen, D.4    Dusaj, R.5    Shaw, L.J.6
  • 13
    • 84901666925 scopus 로고    scopus 로고
    • Inappropriate utilization of SPECT myocardial perfusion imaging on the USA-Mexico border
    • PID: 24627346
    • Lalude OO, Gutarra MF, Pollono EN, Lee S, Tarwater PM. Inappropriate utilization of SPECT myocardial perfusion imaging on the USA-Mexico border. J Nucl Cardiol 2014;21:544-52.
    • (2014) J Nucl Cardiol , vol.21 , pp. 544-552
    • Lalude, O.O.1    Gutarra, M.F.2    Pollono, E.N.3    Lee, S.4    Tarwater, P.M.5
  • 14
    • 84893967705 scopus 로고    scopus 로고
    • Utilization patterns of single-photon emission cardiac tomography myocardial perfusion imaging studies in a rural tertiary care setting
    • PID: 24399332
    • Singh M, Babayan Z, Harjai KJ, Dedhia P, Sattur S, Jagasia DH. Utilization patterns of single-photon emission cardiac tomography myocardial perfusion imaging studies in a rural tertiary care setting. Clin Cardiol. 2014;37:67-72.
    • (2014) Clin Cardiol , vol.37 , pp. 67-72
    • Singh, M.1    Babayan, Z.2    Harjai, K.J.3    Dedhia, P.4    Sattur, S.5    Jagasia, D.H.6
  • 15
    • 84883785650 scopus 로고    scopus 로고
    • Appropriate test selection for single-photon emission computed tomography imaging: Association with clinical risk, posttest management, and outcomes
    • PID: 24016510
    • Aldweib N, Negishi K, Seicean S, Jaber WA, Hachamovitch R, Cerqueira M, et al. Appropriate test selection for single-photon emission computed tomography imaging: Association with clinical risk, posttest management, and outcomes. Am Heart J 2013;166:581-8.
    • (2013) Am Heart J , vol.166 , pp. 581-588
    • Aldweib, N.1    Negishi, K.2    Seicean, S.3    Jaber, W.A.4    Hachamovitch, R.5    Cerqueira, M.6
  • 16
    • 80052486435 scopus 로고    scopus 로고
    • Gender disparity and the appropriateness of myocardial perfusion imaging
    • PID: 21516377
    • Gupta A, Tsiaras SV, Dunsiger SI, Tilkemeier PL. Gender disparity and the appropriateness of myocardial perfusion imaging. J Nucl Cardiol 2011;18:588-94.
    • (2011) J Nucl Cardiol , vol.18 , pp. 588-594
    • Gupta, A.1    Tsiaras, S.V.2    Dunsiger, S.I.3    Tilkemeier, P.L.4
  • 17
    • 79958228220 scopus 로고    scopus 로고
    • Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging in an Asian tertiary cardiac center
    • PID: 21107927
    • Koh AS, Flores JL, Keng FY, Tan RS, Chua TS. Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging in an Asian tertiary cardiac center. J Nucl Cardiol 2011;18:324-30.
    • (2011) J Nucl Cardiol , vol.18 , pp. 324-330
    • Koh, A.S.1    Flores, J.L.2    Keng, F.Y.3    Tan, R.S.4    Chua, T.S.5
  • 18
    • 44149086854 scopus 로고    scopus 로고
    • Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging
    • PID: 18513640
    • Mehta R, Ward RP, Chandra S, Agarwal R, Williams KA. Evaluation of the American College of Cardiology Foundation/American Society of Nuclear Cardiology appropriateness criteria for SPECT myocardial perfusion imaging. J Nucl Cardiol 2008;15:337-44.
    • (2008) J Nucl Cardiol , vol.15 , pp. 337-344
    • Mehta, R.1    Ward, R.P.2    Chandra, S.3    Agarwal, R.4    Williams, K.A.5
  • 19
    • 40849096343 scopus 로고    scopus 로고
    • Application of appropriateness criteria to stress single-photon emission computed tomography sestamibi studies and stress echocardiograms in an academic medical center
    • PID: 18371560
    • Gibbons RJ, Miller TD, Hodge D, Urban L, Araoz PA, Pellikka P, et al. Application of appropriateness criteria to stress single-photon emission computed tomography sestamibi studies and stress echocardiograms in an academic medical center. J Am Coll Cardiol 2008;51:1283-9.
    • (2008) J Am Coll Cardiol , vol.51 , pp. 1283-1289
    • Gibbons, R.J.1    Miller, T.D.2    Hodge, D.3    Urban, L.4    Araoz, P.A.5    Pellikka, P.6
  • 20
    • 84885834370 scopus 로고    scopus 로고
    • Impact of appropriate use on the prognostic value of single-photon emission computed tomography myocardial perfusion imaging
    • PID: 24021779
    • Doukky R, Hayes K, Frogge N, Balakrishnan G, Dontaraju VS, Rangel MO, et al. Impact of appropriate use on the prognostic value of single-photon emission computed tomography myocardial perfusion imaging. Circulation 2013;128:1634-43.
    • (2013) Circulation , vol.128 , pp. 1634-1643
    • Doukky, R.1    Hayes, K.2    Frogge, N.3    Balakrishnan, G.4    Dontaraju, V.S.5    Rangel, M.O.6
  • 21
    • 84939874446 scopus 로고    scopus 로고
    • Clinical utility of inappropriate positron emission tomography myocardial perfusion imaging: Test results and cardiovascular events
    • PID: 25084975
    • Winchester DE, Chauffe RJ, Meral R, Nguyen D, Ryals S, Dusaj R, et al. Clinical utility of inappropriate positron emission tomography myocardial perfusion imaging: Test results and cardiovascular events. J Nucl Cardiol 2015;22:9-15.
    • (2015) J Nucl Cardiol , vol.22 , pp. 9-15
    • Winchester, D.E.1    Chauffe, R.J.2    Meral, R.3    Nguyen, D.4    Ryals, S.5    Dusaj, R.6
  • 22
    • 84863497856 scopus 로고    scopus 로고
    • Correlation between clinical outcomes and appropriateness grading for referral to myocardial perfusion imaging for preoperative evaluation prior to non-cardiac surgery
    • PID: 22314553
    • Koh AS, Flores JL, Keng FY, Tan RS, Chua TS. Correlation between clinical outcomes and appropriateness grading for referral to myocardial perfusion imaging for preoperative evaluation prior to non-cardiac surgery. J Nucl Cardiol 2012;19:277-84.
    • (2012) J Nucl Cardiol , vol.19 , pp. 277-284
    • Koh, A.S.1    Flores, J.L.2    Keng, F.Y.3    Tan, R.S.4    Chua, T.S.5
  • 23
  • 24
    • 0022992740 scopus 로고
    • Meta-analysis in clinical trials
    • COI: 1:STN:280:DyaL2s7gsVamtA%3D%3D, PID: 3802833
    • DerSimonian R, Laird N. Meta-analysis in clinical trials. Control Clin Trials 1986;7:177-88.
    • (1986) Control Clin Trials , vol.7 , pp. 177-188
    • DerSimonian, R.1    Laird, N.2
  • 25
    • 0034685429 scopus 로고    scopus 로고
    • Meta-analysis of observational studies in epidemiology: A proposal for reporting
    • COI: 1:STN:280:DC%2BD3c3kvVGgsA%3D%3D, PID: 10789670
    • Stroup DF, Berlin JA, Morton SC, Olkin I, Williamson GD, Rennie D, et al. Meta-analysis of observational studies in epidemiology: A proposal for reporting. JAMA 2000;283:2008-12.
    • (2000) JAMA , vol.283 , pp. 2008-2012
    • Stroup, D.F.1    Berlin, J.A.2    Morton, S.C.3    Olkin, I.4    Williamson, G.D.5    Rennie, D.6
  • 26
    • 84906048315 scopus 로고    scopus 로고
    • Applicability of the appropriate use criteria for SPECT myocardial perfusion imaging in Italy: Preliminary results
    • COI: 1:STN:280:DC%2BC2crktFymtA%3D%3D, PID: 24633473
    • Medolago G, Marcassa C, Alkraisheh A, Campini R, Ghilardi A, Giubbini R. Applicability of the appropriate use criteria for SPECT myocardial perfusion imaging in Italy: Preliminary results. Eur J Nucl Med Mol Imaging 2014;41:1695-700.
    • (2014) Eur J Nucl Med Mol Imaging , vol.41 , pp. 1695-1700
    • Medolago, G.1    Marcassa, C.2    Alkraisheh, A.3    Campini, R.4    Ghilardi, A.5    Giubbini, R.6
  • 27
    • 84903180489 scopus 로고    scopus 로고
    • Improving appropriate use of echocardiography and single-photon emission computed tomographic myocardial perfusion imaging: A continuous quality improvement initiative
    • PID: 24726335
    • Johnson TV, Rose GA, Fenner DJ, Rozario NL. Improving appropriate use of echocardiography and single-photon emission computed tomographic myocardial perfusion imaging: A continuous quality improvement initiative. J Am Soc Echocardiogr 2014;27:749-57.
    • (2014) J Am Soc Echocardiogr , vol.27 , pp. 749-757
    • Johnson, T.V.1    Rose, G.A.2    Fenner, D.J.3    Rozario, N.L.4
  • 28
    • 84890944855 scopus 로고    scopus 로고
    • Downstream clinical implications of abnormal myocardial perfusion single-photon emission computed tomography based on appropriate use criteria
    • PID: 24136363
    • Khawaja FJ, Jouni H, Miller TD, Hodge DO, Gibbons RJ. Downstream clinical implications of abnormal myocardial perfusion single-photon emission computed tomography based on appropriate use criteria. J Nucl Cardiol 2013;20:1041-8.
    • (2013) J Nucl Cardiol , vol.20 , pp. 1041-1048
    • Khawaja, F.J.1    Jouni, H.2    Miller, T.D.3    Hodge, D.O.4    Gibbons, R.J.5
  • 29
    • 84880274822 scopus 로고    scopus 로고
    • Impact of an automated multimodality point-of-order decision support tool on rates of appropriate testing and clinical decision making for individuals with suspected coronary artery disease: A prospective multicenter study
    • PID: 23707319
    • Lin FY, Dunning AM, Narula J, Shaw LJ, Gransar H, Berman DS, et al. Impact of an automated multimodality point-of-order decision support tool on rates of appropriate testing and clinical decision making for individuals with suspected coronary artery disease: A prospective multicenter study. J Am Coll Cardiol 2013;62:308-16.
    • (2013) J Am Coll Cardiol , vol.62 , pp. 308-316
    • Lin, F.Y.1    Dunning, A.M.2    Narula, J.3    Shaw, L.J.4    Gransar, H.5    Berman, D.S.6
  • 30
    • 84879499439 scopus 로고    scopus 로고
    • A multicenter evaluation of the appropriate use of single-photon emission tomography myocardial perfusion imaging in Greece
    • PID: 23430360
    • Moralidis E, Papadimitriou N, Stathaki M, Xourgia X, Spyridonidis T, Fotopoulos A, et al. A multicenter evaluation of the appropriate use of single-photon emission tomography myocardial perfusion imaging in Greece. J Nucl Cardiol 2013;20:275-83.
    • (2013) J Nucl Cardiol , vol.20 , pp. 275-283
    • Moralidis, E.1    Papadimitriou, N.2    Stathaki, M.3    Xourgia, X.4    Spyridonidis, T.5    Fotopoulos, A.6
  • 31
    • 84859385729 scopus 로고    scopus 로고
    • Application of appropriate use criteria for stress myocardial perfusion imaging at two academic medical centers: Compliance and association with image findings
    • PID: 22486835
    • Soine LA, Cunningham SL, Motzer SA, Inoue LY, Caldwell JH. Application of appropriate use criteria for stress myocardial perfusion imaging at two academic medical centers: Compliance and association with image findings. J Am Acad Nurse Pract 2012;24:200-8.
    • (2012) J Am Acad Nurse Pract , vol.24 , pp. 200-208
    • Soine, L.A.1    Cunningham, S.L.2    Motzer, S.A.3    Inoue, L.Y.4    Caldwell, J.H.5
  • 32
    • 84861523061 scopus 로고    scopus 로고
    • Utilization of radionuclide myocardial perfusion imaging in two health care systems: Assessment with the 2009 ACCF/ASNC/AHA appropriateness use criteria
    • PID: 22045393
    • Nelson KH, Willens HJ, Hendel RC. Utilization of radionuclide myocardial perfusion imaging in two health care systems: Assessment with the 2009 ACCF/ASNC/AHA appropriateness use criteria. J Nucl Cardiol 2012;19:37-42.
    • (2012) J Nucl Cardiol , vol.19 , pp. 37-42
    • Nelson, K.H.1    Willens, H.J.2    Hendel, R.C.3
  • 33
    • 84655167552 scopus 로고    scopus 로고
    • Appropriateness of referrals for single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) in a developing community: A comparison between 2005 and 2009 versions of ACCF/ASNC appropriateness criteria
    • PID: 21818700
    • Gholamrezanezhad A, Shirafkan A, Mirpour S, Rayatnavaz M, Alborzi A, Mogharrabi M, et al. Appropriateness of referrals for single-photon emission computed tomography myocardial perfusion imaging (SPECT-MPI) in a developing community: A comparison between 2005 and 2009 versions of ACCF/ASNC appropriateness criteria. J Nucl Cardiol 2011;18:1044-52.
    • (2011) J Nucl Cardiol , vol.18 , pp. 1044-1052
    • Gholamrezanezhad, A.1    Shirafkan, A.2    Mirpour, S.3    Rayatnavaz, M.4    Alborzi, A.5    Mogharrabi, M.6
  • 34
    • 84893117521 scopus 로고    scopus 로고
    • Clinical evaluation of the appropriateness use criteria for single-photon emission-computed tomography: Differences by patient population, physician specialty, and patient outcomes
    • PID: 22347656
    • Druz RS, Phillips LM, Sharifova G. Clinical evaluation of the appropriateness use criteria for single-photon emission-computed tomography: Differences by patient population, physician specialty, and patient outcomes. ISRN Cardiol 2011;2011:798318.
    • (2011) ISRN Cardiol , vol.2011 , pp. 798318
    • Druz, R.S.1    Phillips, L.M.2    Sharifova, G.3
  • 35
    • 77955446280 scopus 로고    scopus 로고
    • Application of appropriateness criteria to stress single photon emission computed tomography sestamibi studies: A comparison of the 2009 revised appropriateness criteria to the 2005 original criteria
    • PID: 20691828
    • Carryer DJ, Hodge DO, Miller TD, Askew JW, Gibbons RJ. Application of appropriateness criteria to stress single photon emission computed tomography sestamibi studies: A comparison of the 2009 revised appropriateness criteria to the 2005 original criteria. Am Heart J 2010;160:244-9.
    • (2010) Am Heart J , vol.160 , pp. 244-249
    • Carryer, D.J.1    Hodge, D.O.2    Miller, T.D.3    Askew, J.W.4    Gibbons, R.J.5
  • 36
    • 73049086777 scopus 로고    scopus 로고
    • A multicenter assessment of the use of single-photon emission computed tomography myocardial perfusion imaging with appropriateness criteria
    • PID: 20117384
    • Hendel RC, Cerqueira M, Douglas PS, Caruth KC, Allen JM, Jensen NC, et al. A multicenter assessment of the use of single-photon emission computed tomography myocardial perfusion imaging with appropriateness criteria. J Am Coll Cardiol 2010;55:156-62.
    • (2010) J Am Coll Cardiol , vol.55 , pp. 156-162
    • Hendel, R.C.1    Cerqueira, M.2    Douglas, P.S.3    Caruth, K.C.4    Allen, J.M.5    Jensen, N.C.6
  • 37
    • 84893854578 scopus 로고    scopus 로고
    • ACCF/AHA/ASE/ASNC/HFSA/HRS/SCAI/SCCT/SCMR/STS 2013 multimodality appropriate use criteria for the detection and risk assessment of stable ischemic heart disease: A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, American Heart Association, American Society of Echocardiography, American Society of Nuclear Cardiology, Heart Failure Society of America, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, and Society of Thoracic Surgeons
    • PID: 24374980
    • Ronan G, Wolk MJ, Bailey SR, Doherty JU, Douglas PS, Hendel RC, et al. ACCF/AHA/ASE/ASNC/HFSA/HRS/SCAI/SCCT/SCMR/STS 2013 multimodality appropriate use criteria for the detection and risk assessment of stable ischemic heart disease: A report of the American College of Cardiology Foundation Appropriate Use Criteria Task Force, American Heart Association, American Society of Echocardiography, American Society of Nuclear Cardiology, Heart Failure Society of America, Heart Rhythm Society, Society for Cardiovascular Angiography and Interventions, Society of Cardiovascular Computed Tomography, Society for Cardiovascular Magnetic Resonance, and Society of Thoracic Surgeons. J Nucl Cardiol 2014;21:192-220.
    • (2014) J Nucl Cardiol. , vol.21 , pp. 192-220
    • Ronan, G.1    Wolk, M.J.2    Bailey, S.R.3    Doherty, J.U.4    Douglas, P.S.5    Hendel, R.C.6
  • 38
    • 84979065288 scopus 로고    scopus 로고
    • FOCUS Initiative,. Accessed March 4, 2015
    • FOCUS Initiative, http://www.cardiosource.org/Science-And-Quality/Quality-Programs/Imaging-in-FOCUS/. Accessed March 4, 2015.
  • 39
    • 84890924141 scopus 로고    scopus 로고
    • ASNC ImageGuide™: Cardiovascular imaging data registry
    • PID: 24165754
    • Tilkemeier P, Wang TY, Lytle BL, Denton EA. ASNC ImageGuide™: Cardiovascular imaging data registry. J Nucl Cardiol 2013;20:1186-7.
    • (2013) J Nucl Cardiol , vol.20 , pp. 1186-1187
    • Tilkemeier, P.1    Wang, T.Y.2    Lytle, B.L.3    Denton, E.A.4
  • 40
    • 84906316769 scopus 로고    scopus 로고
    • Are cardiologists truly better at appropriately selecting patients for stress myocardial perfusion imaging?
    • PID: 25042647
    • Doukky R, Hayes K, Frogge N. Are cardiologists truly better at appropriately selecting patients for stress myocardial perfusion imaging? Int J Cardiol 2014;176:285-6.
    • (2014) Int J Cardiol , vol.176 , pp. 285-286
    • Doukky, R.1    Hayes, K.2    Frogge, N.3
  • 41
    • 84863987684 scopus 로고    scopus 로고
    • Cardiologist concordance with the American College of Cardiology appropriate use criteria for cardiac testing in patients with coronary artery disease
    • PID: 22534053
    • Lin FY, Rosenbaum LR, Gebow D, Kim RJ, Wolk MJ, Patel MR, et al. Cardiologist concordance with the American College of Cardiology appropriate use criteria for cardiac testing in patients with coronary artery disease. Am J Cardiol 2012;110:337-44.
    • (2012) Am J Cardiol , vol.110 , pp. 337-344
    • Lin, F.Y.1    Rosenbaum, L.R.2    Gebow, D.3    Kim, R.J.4    Wolk, M.J.5    Patel, M.R.6
  • 42
    • 84937039167 scopus 로고    scopus 로고
    • Effect of evidence-based clinical decision support on the use and yield of CT pulmonary angiographic imaging in hospitalized patients
    • PID: 25686367
    • Dunne RM, Ip IK, Abbett S, Gershanik EF, Raja AS, Hunsaker A, et al. Effect of evidence-based clinical decision support on the use and yield of CT pulmonary angiographic imaging in hospitalized patients. Radiology 2015;276:167-74.
    • (2015) Radiology , vol.276 , pp. 167-174
    • Dunne, R.M.1    Ip, I.K.2    Abbett, S.3    Gershanik, E.F.4    Raja, A.S.5    Hunsaker, A.6
  • 43
    • 84926519922 scopus 로고    scopus 로고
    • The effect of clinical decision support for advanced inpatient imaging
    • PID: 25622766
    • Moriarity AK, Klochko C, O’Brien M, Halabi S. The effect of clinical decision support for advanced inpatient imaging. J Am Coll Radiol 2015;12:358-63.
    • (2015) J Am Coll Radiol , vol.12 , pp. 358-363
    • Moriarity, A.K.1    Klochko, C.2    O’Brien, M.3    Halabi, S.4
  • 44
    • 84926634333 scopus 로고    scopus 로고
    • Effectiveness of interventions designed to reduce the use of imaging for low-back pain: A systematic review
    • PID: 25733741
    • Jenkins HJ, Hancock MJ, French SD, Maher CG, Engel RM, Magnussen JS. Effectiveness of interventions designed to reduce the use of imaging for low-back pain: A systematic review. CMAJ 2015;187:401-8.
    • (2015) CMAJ , vol.187 , pp. 401-408
    • Jenkins, H.J.1    Hancock, M.J.2    French, S.D.3    Maher, C.G.4    Engel, R.M.5    Magnussen, J.S.6
  • 45
    • 84929662688 scopus 로고    scopus 로고
    • Impact of insurance carrier, prior authorization and socioeconomic status on appropriate use of SPECT myocardial perfusion imaging in private community-based office practice
    • PID: 25955195
    • Doukky R, Hayes K, Frogge N, Nazir NT, Collado FM, Williams KA. Impact of insurance carrier, prior authorization and socioeconomic status on appropriate use of SPECT myocardial perfusion imaging in private community-based office practice. Clin Cardiol 2015;38:267-73.
    • (2015) Clin Cardiol , vol.38 , pp. 267-273
    • Doukky, R.1    Hayes, K.2    Frogge, N.3    Nazir, N.T.4    Collado, F.M.5    Williams, K.A.6
  • 46
    • 67649423540 scopus 로고    scopus 로고
    • Applicability of appropriateness criteria for stress imaging: Similarities and differences between stress echocardiography and single-photon emission computed tomography myocardial perfusion imaging criteria
    • PID: 19808595
    • McCully RB, Pellikka PA, Hodge DO, Araoz PA, Miller TD, Gibbons RJ. Applicability of appropriateness criteria for stress imaging: Similarities and differences between stress echocardiography and single-photon emission computed tomography myocardial perfusion imaging criteria. Circ Cardiovasc Imaging 2009;2:213-8.
    • (2009) Circ Cardiovasc Imaging , vol.2 , pp. 213-218
    • McCully, R.B.1    Pellikka, P.A.2    Hodge, D.O.3    Araoz, P.A.4    Miller, T.D.5    Gibbons, R.J.6
  • 47
    • 84927672541 scopus 로고    scopus 로고
    • Can physicians identify inappropriate nuclear stress tests? An examination of inter-rater reliability for the 2009 appropriate use criteria for radionuclide imaging
    • PID: 25563660
    • Ye S, Rabbani LE, Kelly CR, Kelly MR, Lewis M, Paz Y, et al. Can physicians identify inappropriate nuclear stress tests? An examination of inter-rater reliability for the 2009 appropriate use criteria for radionuclide imaging. Circ Cardiovasc Qual Outcomes 2015;8:23-9.
    • (2015) Circ Cardiovasc Qual Outcomes , vol.8 , pp. 23-29
    • Ye, S.1    Rabbani, L.E.2    Kelly, C.R.3    Kelly, M.R.4    Lewis, M.5    Paz, Y.6
  • 49
    • 84880670629 scopus 로고    scopus 로고
    • Appropriate use of myocardial perfusion imaging in a veteran population: Profit motives and professional liability concerns
    • PID: 23752899
    • Winchester DE, Meral R, Ryals S, Beyth RJ, Shaw LJ. Appropriate use of myocardial perfusion imaging in a veteran population: Profit motives and professional liability concerns. JAMA Intern Med 2013;173:1381-3.
    • (2013) JAMA Intern Med , vol.173 , pp. 1381-1383
    • Winchester, D.E.1    Meral, R.2    Ryals, S.3    Beyth, R.J.4    Shaw, L.J.5
  • 50
    • 79951670176 scopus 로고    scopus 로고
    • Appropriate use criteria for stress single-photon emission computed tomography sestamibi studies: A quality improvement project
    • PID: 21262995
    • Gibbons RJ, Askew JW, Hodge D, Kaping B, Carryer DJ, Miller T. Appropriate use criteria for stress single-photon emission computed tomography sestamibi studies: A quality improvement project. Circulation 2011;123:499-503.
    • (2011) Circulation , vol.123 , pp. 499-503
    • Gibbons, R.J.1    Askew, J.W.2    Hodge, D.3    Kaping, B.4    Carryer, D.J.5    Miller, T.6
  • 51
    • 77649244399 scopus 로고    scopus 로고
    • Temporal trends in compliance with appropriateness criteria for stress single-photon emission computed tomography sestamibi studies in an academic medical center
    • PID: 20211313
    • Gibbons RJ, Askew JW, Hodge D, Miller TD. Temporal trends in compliance with appropriateness criteria for stress single-photon emission computed tomography sestamibi studies in an academic medical center. Am Heart J 2010;159:484-9.
    • (2010) Am Heart J , vol.159 , pp. 484-489
    • Gibbons, R.J.1    Askew, J.W.2    Hodge, D.3    Miller, T.D.4
  • 52
    • 84922682734 scopus 로고    scopus 로고
    • Application of appropriate use criteria to cardiac stress testing in the hospital setting: Limitations of the criteria and areas for improved practice
    • PID: 25336343
    • Gertz ZM, O’Donnell W, Raina A, Litwack AJ, Balderston JR, Goldberg LR. Application of appropriate use criteria to cardiac stress testing in the hospital setting: Limitations of the criteria and areas for improved practice. Clin Cardiol 2015;38:8-12.
    • (2015) Clin Cardiol , vol.38 , pp. 8-12
    • Gertz, Z.M.1    O’Donnell, W.2    Raina, A.3    Litwack, A.J.4    Balderston, J.R.5    Goldberg, L.R.6
  • 53
    • 84928096685 scopus 로고    scopus 로고
    • Comparison of recent utilization trends in radionuclide myocardial perfusion imaging among radiologists and cardiologists
    • PID: 17411941
    • Levin DC, Intenzo CM, Rao VM, Frangos AJ, Parker L, Sunshine JH. Comparison of recent utilization trends in radionuclide myocardial perfusion imaging among radiologists and cardiologists. J Am Coll Radiol 2005;2:821-4.
    • (2005) J Am Coll Radiol , vol.2 , pp. 821-824
    • Levin, D.C.1    Intenzo, C.M.2    Rao, V.M.3    Frangos, A.J.4    Parker, L.5    Sunshine, J.H.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.