메뉴 건너뛰기




Volumn 8, Issue 3, 2015, Pages 551-556

Blood Pressure and Adverse Events during Continuous Flow Left Ventricular Assist Device Support

Author keywords

aortic valve insufficiency; blood pressure; cerebral hemorrhage; thrombosis

Indexed keywords

ANGIOTENSIN RECEPTOR ANTAGONIST; DIPEPTIDYL CARBOXYPEPTIDASE INHIBITOR;

EID: 84938521713     PISSN: 19413289     EISSN: 19413297     Source Type: Journal    
DOI: 10.1161/CIRCHEARTFAILURE.114.002000     Document Type: Article
Times cited : (70)

References (12)
  • 2
    • 77950520808 scopus 로고    scopus 로고
    • Ideal methodology to assess systemic blood pressure in patients with continuous-flow left ventricular assist devices
    • Bennett MK, Roberts CA, Dordunoo D, Shah A, Russell SD. Ideal methodology to assess systemic blood pressure in patients with continuous-flow left ventricular assist devices. J Heart Lung Transplant. 2010;29:593-594. doi: 10.1016/j.healun.2009.11.604.
    • (2010) J Heart Lung Transplant , vol.29 , pp. 593-594
    • Bennett, M.K.1    Roberts, C.A.2    Dordunoo, D.3    Shah, A.4    Russell, S.D.5
  • 5
    • 0022895386 scopus 로고
    • Hypertension as a risk factor for spontaneous intracerebral hemorrhage
    • Brott T, Thalinger K, Hertzberg V. Hypertension as a risk factor for spontaneous intracerebral hemorrhage. Stroke. 1986;17:1078-1083.
    • (1986) Stroke , vol.17 , pp. 1078-1083
    • Brott, T.1    Thalinger, K.2    Hertzberg, V.3
  • 7
    • 78650096247 scopus 로고    scopus 로고
    • The development of aortic insufficiency in left ventricular assist devicesupported patients
    • Cowger J, Pagani FD, Haft JW, Romano MA, Aaronson KD, Kolias TJ. The development of aortic insufficiency in left ventricular assist devicesupported patients. Circ Heart Fail. 2010;3:668-674. doi: 10.1161/CIRCHEARTFAILURE.109.917765.
    • (2010) Circ Heart Fail , vol.3 , pp. 668-674
    • Cowger, J.1    Pagani, F.D.2    Haft, J.W.3    Romano, M.A.4    Aaronson, K.D.5    Kolias, T.J.6
  • 8
    • 0035437458 scopus 로고    scopus 로고
    • Insufficiency of the native aortic valve and left ventricular assist system inflow valve after support with an implantable left ventricular assist system: Signs, symptoms, and concerns
    • Samuels LE, Thomas MP, Holmes EC, Narula J, Fitzpatrick J, Wood D, Fyfe B, Wechsler AS. Insufficiency of the native aortic valve and left ventricular assist system inflow valve after support with an implantable left ventricular assist system: signs, symptoms, and concerns. J Thorac Cardiovasc Surg. 2001;122:380-381. doi: 10.1067/mtc.2001.114770.
    • (2001) J Thorac Cardiovasc Surg , vol.122 , pp. 380-381
    • Samuels, L.E.1    Thomas, M.P.2    Holmes, E.C.3    Narula, J.4    Fitzpatrick, J.5    Wood, D.6    Fyfe, B.7    Wechsler, A.S.8
  • 9
    • 64049108554 scopus 로고    scopus 로고
    • Elevated cyclic stretch alters matrix remodeling in aortic valve cusps: Implications for degenerative aortic valve disease
    • Balachandran K, Sucosky P, Jo H, Yoganathan AP. Elevated cyclic stretch alters matrix remodeling in aortic valve cusps: implications for degenerative aortic valve disease. Am J Physiol Heart Circ Physiol. 2009;296:H756-H764. doi: 10.1152/ajpheart.00900.2008.
    • (2009) Am J Physiol Heart Circ Physiol , vol.296 , pp. H756-H764
    • Balachandran, K.1    Sucosky, P.2    Jo, H.3    Yoganathan, A.P.4
  • 10
    • 33744991763 scopus 로고    scopus 로고
    • Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta
    • May-Newman K, Hillen B, Dembitsky W. Effect of left ventricular assist device outflow conduit anastomosis location on flow patterns in the native aorta. ASAIO J. 2006;52:132-139. doi: 10.1097/01. mat.0000201961.97981.e9.
    • (2006) ASAIO J , vol.52 , pp. 132-139
    • May-Newman, K.1    Hillen, B.2    Dembitsky, W.3
  • 12
    • 79952636198 scopus 로고    scopus 로고
    • Response of rotary blood pumps to changes in preload and afterload at a fixed speed setting are unphysiological when compared with the natural heart
    • Salamonsen RF, Mason DG, Ayre PJ. Response of rotary blood pumps to changes in preload and afterload at a fixed speed setting are unphysiological when compared with the natural heart. Artif Organs. 2011;35:E47-E53. doi: 10.1111/j.1525-1594.2010.01168.x.
    • (2011) Artif Organs , vol.35 , pp. E47-E53
    • Salamonsen, R.F.1    Mason, D.G.2    Ayre, P.J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.