메뉴 건너뛰기




Volumn 103, Issue , 2015, Pages 1031-1039

A new procedure for estimating the cell temperature of a high concentrator photovoltaic grid connected system based on atmospheric parameters

Author keywords

Atmospheric parameters; Cell temperature at maximum power; High concentrator photovoltaic systems; Mathematical methods

Indexed keywords

ARTIFICIAL INTELLIGENCE; CELLS; CONCENTRATION (PROCESS); CYTOLOGY; ELECTRIC INVERTERS; ERRORS; ESTIMATION; MEAN SQUARE ERROR; OPEN CIRCUIT VOLTAGE; PARAMETER ESTIMATION; PHOTOVOLTAIC CELLS;

EID: 84938367305     PISSN: 01968904     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enconman.2015.07.034     Document Type: Article
Times cited : (24)

References (47)
  • 1
    • 33746080913 scopus 로고    scopus 로고
    • Photovoltaic concentration at the onset of its commercial deployment
    • A. Luque, G. Sala, and I. Luque-Heredia Photovoltaic concentration at the onset of its commercial deployment Prog Photovoltaics Res Appl 14 5 2006 413 428
    • (2006) Prog Photovoltaics Res Appl , vol.14 , Issue.5 , pp. 413-428
    • Luque, A.1    Sala, G.2    Luque-Heredia, I.3
  • 2
    • 68749091091 scopus 로고    scopus 로고
    • High concentration photovoltaic systems applying III-V cells
    • G. Zubi, J. Bernal-Agustín, and G. Fracastoro High concentration photovoltaic systems applying III-V cells Renew Sustain Energy Rev 13 9 2009 2645 2652
    • (2009) Renew Sustain Energy Rev , vol.13 , Issue.9 , pp. 2645-2652
    • Zubi, G.1    Bernal-Agustín, J.2    Fracastoro, G.3
  • 4
    • 79955490293 scopus 로고    scopus 로고
    • Concentrated solar energy applications using Fresnel lenses: A review
    • W. Xie, Y. Dai, R. Wang, and K. Sumathy Concentrated solar energy applications using Fresnel lenses: a review Renew Sustain Energy Rev 15 6 2011 2588 2606
    • (2011) Renew Sustain Energy Rev , vol.15 , Issue.6 , pp. 2588-2606
    • Xie, W.1    Dai, Y.2    Wang, R.3    Sumathy, K.4
  • 5
    • 65149095633 scopus 로고    scopus 로고
    • Comparative analysis of different secondary optical elements for aspheric primary lenses
    • M. Victoria, C. Doḿinguez, I. Anton, and G. Sala Comparative analysis of different secondary optical elements for aspheric primary lenses Opt Express 17 9 2009 6487 6492
    • (2009) Opt Express , vol.17 , Issue.9 , pp. 6487-6492
    • Victoria, M.1    Doḿinguez, C.2    Anton, I.3    Sala, G.4
  • 6
    • 84878192388 scopus 로고    scopus 로고
    • Outdoor evaluation of concentrator photovoltaic systems modules from different manufacturers: First results and steps
    • E. Fernández, P. Pérez-Higueras, A. García Loureiro, and P. Vidal Outdoor evaluation of concentrator photovoltaic systems modules from different manufacturers: first results and steps Prog Photovoltaics Res Appl 21 4 2013 693 701
    • (2013) Prog Photovoltaics Res Appl , vol.21 , Issue.4 , pp. 693-701
    • Fernández, E.1    Pérez-Higueras, P.2    García Loureiro, A.3    Vidal, P.4
  • 8
    • 84906247362 scopus 로고    scopus 로고
    • Power conversion in concentrating photovoltaic systems: Central, string, and micro-inverters
    • Y. Kim, and R. Winston Power conversion in concentrating photovoltaic systems: central, string, and micro-inverters Prog Photovoltaics Res Appl 22 9 2014 984 992
    • (2014) Prog Photovoltaics Res Appl , vol.22 , Issue.9 , pp. 984-992
    • Kim, Y.1    Winston, R.2
  • 10
    • 84928537310 scopus 로고    scopus 로고
    • Levelised cost of electricity in high concentrated photovoltaic grid connected systems: Spatial analysis of Spain
    • D. Talavera, P. Pérez-Higueras, J. Ruíz-Arias, and E. Fernández Levelised cost of electricity in high concentrated photovoltaic grid connected systems: spatial analysis of Spain Appl Energy 151 2015 49 59
    • (2015) Appl Energy , vol.151 , pp. 49-59
    • Talavera, D.1    Pérez-Higueras, P.2    Ruíz-Arias, J.3    Fernández, E.4
  • 11
  • 12
    • 84922586625 scopus 로고    scopus 로고
    • Experimental study of liquid-immersion III-V multi-junction solar cells with dimethyl silicon oil under high concentrations
    • G. Xin, Y. Wang, Y. Sun, Q. Huang, and L. Zhu Experimental study of liquid-immersion III-V multi-junction solar cells with dimethyl silicon oil under high concentrations Energy Convers Manage 94 2015 169 177
    • (2015) Energy Convers Manage , vol.94 , pp. 169-177
    • Xin, G.1    Wang, Y.2    Sun, Y.3    Huang, Q.4    Zhu, L.5
  • 13
    • 84876702149 scopus 로고    scopus 로고
    • A two subcell equivalent solar cell model for III-V triple junction solar cells under spectrum and temperature variations
    • E. Fernández, G. Siefer, F. Almonacid, A. García-Loureiro, and P. Pérez-Higueras A two subcell equivalent solar cell model for III-V triple junction solar cells under spectrum and temperature variations Sol Energy 92 2013 221 229
    • (2013) Sol Energy , vol.92 , pp. 221-229
    • Fernández, E.1    Siefer, G.2    Almonacid, F.3    García-Loureiro, A.4    Pérez-Higueras, P.5
  • 14
    • 84927569869 scopus 로고    scopus 로고
    • Temperature accelerated life test on commercial concentrator III-V triple-junction solar cells and reliability analysis as a function of the operating temperature
    • P. Espinet-González, C. Algora, N. Núñez, V. Orlando, M. Vázquez, J. Bautista, and et al. Temperature accelerated life test on commercial concentrator III-V triple-junction solar cells and reliability analysis as a function of the operating temperature Prog Photovoltaics Res Appl 23 5 2015 559 569
    • (2015) Prog Photovoltaics Res Appl , vol.23 , Issue.5 , pp. 559-569
    • Espinet-González, P.1    Algora, C.2    Núñez, N.3    Orlando, V.4    Vázquez, M.5    Bautista, J.6
  • 15
    • 84873037542 scopus 로고    scopus 로고
    • Opportunities and challenges in micro- and nano-technologies for concentrating photovoltaic cooling: A review
    • L. Micheli, N. Sarmah, X. Luo, K. Reddy, and T. Mallick Opportunities and challenges in micro- and nano-technologies for concentrating photovoltaic cooling: a review Renew Sustain Energy Rev 20 2013 595 610
    • (2013) Renew Sustain Energy Rev , vol.20 , pp. 595-610
    • Micheli, L.1    Sarmah, N.2    Luo, X.3    Reddy, K.4    Mallick, T.5
  • 16
    • 13844316975 scopus 로고    scopus 로고
    • Cooling of photovoltaic cells under concentrated illumination: A critical review
    • A. Royne, C. Dey, and D. Mills Cooling of photovoltaic cells under concentrated illumination: a critical review Sol Energy Mater Sol Cells 86 4 2005 451 483
    • (2005) Sol Energy Mater Sol Cells , vol.86 , Issue.4 , pp. 451-483
    • Royne, A.1    Dey, C.2    Mills, D.3
  • 17
    • 84882296873 scopus 로고    scopus 로고
    • Characterization of the InGaP/InGaAs/Ge triple-junction solar cell with a two-stage dish-style concentration system
    • Z. Wang, H. Zhang, D. Wen, W. Zhao, and Z. Zhou Characterization of the InGaP/InGaAs/Ge triple-junction solar cell with a two-stage dish-style concentration system Energy Convers Manage 76 2013 177 184
    • (2013) Energy Convers Manage , vol.76 , pp. 177-184
    • Wang, Z.1    Zhang, H.2    Wen, D.3    Zhao, W.4    Zhou, Z.5
  • 19
    • 84877122907 scopus 로고    scopus 로고
    • An improved temperature estimation method for solar cells operating at high concentrations
    • X. Ju, A. Vossier, Z. Wang, A. Dollet, and G. Flamant An improved temperature estimation method for solar cells operating at high concentrations Sol Energy 93 2013 80 89
    • (2013) Sol Energy , vol.93 , pp. 80-89
    • Ju, X.1    Vossier, A.2    Wang, Z.3    Dollet, A.4    Flamant, G.5
  • 23
    • 79960564710 scopus 로고    scopus 로고
    • A method for using CPV modules as temperature sensors and its application to rating procedures
    • G. Peharz, J. Ferrer Rodríguez, G. Siefer, and A. Bett A method for using CPV modules as temperature sensors and its application to rating procedures Sol Energy Mater Sol Cells 95 2011 2734 2744
    • (2011) Sol Energy Mater Sol Cells , vol.95 , pp. 2734-2744
    • Peharz, G.1    Ferrer Rodríguez, J.2    Siefer, G.3    Bett, A.4
  • 25
    • 84929582714 scopus 로고    scopus 로고
    • Outdoor performance analysis of a 1090× point-focus Fresnel high concentrator photovoltaic/thermal system with triple-junction solar cells
    • N. Xu, J. Ji, W. Sun, L. Han, H. Chen, and Z. Jin Outdoor performance analysis of a 1090× point-focus Fresnel high concentrator photovoltaic/thermal system with triple-junction solar cells Energy Convers Manage 100 2015 191 200
    • (2015) Energy Convers Manage , vol.100 , pp. 191-200
    • Xu, N.1    Ji, J.2    Sun, W.3    Han, L.4    Chen, H.5    Jin, Z.6
  • 26
  • 27
    • 84894541155 scopus 로고    scopus 로고
    • A method for estimating cell temperature at the maximum power point of a HCPV module under actual operating conditions
    • E. Fernández, P. Rodrigo, F. Almonacid, and P. Pérez-Higueras A method for estimating cell temperature at the maximum power point of a HCPV module under actual operating conditions Sol Energy Mater Sol Cells 124 2014 159 165
    • (2014) Sol Energy Mater Sol Cells , vol.124 , pp. 159-165
    • Fernández, E.1    Rodrigo, P.2    Almonacid, F.3    Pérez-Higueras, P.4
  • 28
    • 84904214731 scopus 로고    scopus 로고
    • Review of methods for the calculation of cell temperature in high concentration photovoltaic modules for electrical characterization
    • P. Rodrigo, E. Fernández, F. Almonacid, and P. Pérez-Higueras Review of methods for the calculation of cell temperature in high concentration photovoltaic modules for electrical characterization Renew Sustain Energy Rev 38 2014 478 488
    • (2014) Renew Sustain Energy Rev , vol.38 , pp. 478-488
    • Rodrigo, P.1    Fernández, E.2    Almonacid, F.3    Pérez-Higueras, P.4
  • 30
    • 84888591771 scopus 로고    scopus 로고
    • Calculation of the cell temperature of a high concentrator photovoltaic (HCPV) module: A study and comparison of different methods
    • E. Fernández, F. Almonacid, P. Rodrigo, and P. Pérez-Higueras Calculation of the cell temperature of a high concentrator photovoltaic (HCPV) module: a study and comparison of different methods Sol Energy Mater Sol Cells 121 2014 144 151
    • (2014) Sol Energy Mater Sol Cells , vol.121 , pp. 144-151
    • Fernández, E.1    Almonacid, F.2    Rodrigo, P.3    Pérez-Higueras, P.4
  • 31
    • 84877095016 scopus 로고    scopus 로고
    • Temperature distribution in 820X CPV module during outdoor operation
    • Y. Ota, H. Nagai, K. Araki, and K. Nishioka Temperature distribution in 820X CPV module during outdoor operation AIP Conf Proc 1477 2012 364 367
    • (2012) AIP Conf Proc , vol.1477 , pp. 364-367
    • Ota, Y.1    Nagai, H.2    Araki, K.3    Nishioka, K.4
  • 32
    • 84901300707 scopus 로고    scopus 로고
    • Analysis of the spectral variations on the performance of high concentrator photovoltaic modules operating under different real climate conditions
    • E. Fernández, F. Almonacid, J. Ruiz-Arias, and A. Soria-Moya Analysis of the spectral variations on the performance of high concentrator photovoltaic modules operating under different real climate conditions Sol Energy Mater Sol Cells 179-187 2014 127
    • (2014) Sol Energy Mater Sol Cells , vol.179-187 , pp. 127
    • Fernández, E.1    Almonacid, F.2    Ruiz-Arias, J.3    Soria-Moya, A.4
  • 33
    • 84975571774 scopus 로고
    • Revised optical air mass tables and approximation formula
    • F. Kasten, and A.T. Young Revised optical air mass tables and approximation formula Appl Opt 28 22 1989 4735 4738
    • (1989) Appl Opt , vol.28 , Issue.22 , pp. 4735-4738
    • Kasten, F.1    Young, A.T.2
  • 34
    • 84892462018 scopus 로고    scopus 로고
    • Impact of on-site atmospheric water vapor estimation methods on the accuracy of local solar irradiance predictions
    • C. Gueymard Impact of on-site atmospheric water vapor estimation methods on the accuracy of local solar irradiance predictions Sol Energy 101 74-82 2014
    • (2014) Sol Energy , vol.101 , Issue.74-82
    • Gueymard, C.1
  • 35
    • 84883236425 scopus 로고    scopus 로고
    • Model for the prediction of the maximum power of a high concentrator photovoltaic module
    • E. Fernández, F. Almonacid, P. Rodrigo, and P. Pérez-Higueras Model for the prediction of the maximum power of a high concentrator photovoltaic module Sol Energy 97 2013 12 18
    • (2013) Sol Energy , vol.97 , pp. 12-18
    • Fernández, E.1    Almonacid, F.2    Rodrigo, P.3    Pérez-Higueras, P.4
  • 36
    • 0019717697 scopus 로고
    • Simplified method for predicting photovoltaic array output
    • D.L. Evans Simplified method for predicting photovoltaic array output Sol Energy 27 6 1981 555 560
    • (1981) Sol Energy , vol.27 , Issue.6 , pp. 555-560
    • Evans, D.L.1
  • 37
    • 0022777984 scopus 로고
    • Translation of device performance measurements to reference conditions
    • C. Osterwald Translation of device performance measurements to reference conditions Solar Cells 18 3-4 1986 269 279
    • (1986) Solar Cells , vol.18 , Issue.3-4 , pp. 269-279
    • Osterwald, C.1
  • 38
    • 84924561614 scopus 로고    scopus 로고
    • Analytical modelling of high concentrator photovoltaic modules based on atmospheric parameters
    • E. Fernández, F. Almonacid, T. Mallick, and P. Pérez-Higueras Analytical modelling of high concentrator photovoltaic modules based on atmospheric parameters Int J Photoenergy 2015 no. art. no. 872163
    • (2015) Int J Photoenergy
    • Fernández, E.1    Almonacid, F.2    Mallick, T.3    Pérez-Higueras, P.4
  • 39
    • 85006065074 scopus 로고    scopus 로고
    • Performance analysis of the lineal model for estimating the maximum power of a HCPV module in different climate conditions
    • E.F. Fernández, F. Almonacid, N. Sarmah, T. Mallick, I. Sanchez, J.M. Cuadra, and et al. Performance analysis of the lineal model for estimating the maximum power of a HCPV module in different climate conditions AIP Conf Proc 1616 2014 187 190
    • (2014) AIP Conf Proc , vol.1616 , pp. 187-190
    • Fernández, E.F.1    Almonacid, F.2    Sarmah, N.3    Mallick, T.4    Sanchez, I.5    Cuadra, J.M.6
  • 42
    • 84901355049 scopus 로고    scopus 로고
    • Analysis of high concentrator photovoltaic modules in outdoor conditions: Influence of direct normal irradiance, air temperature, and air mass
    • E. Fernández, P. Rodrigo, J. Fernández, F. Almonacid, P. Pérez-Higueras, A. García-Loureiro, and et al. Analysis of high concentrator photovoltaic modules in outdoor conditions: influence of direct normal irradiance, air temperature, and air mass J Renew Sustain Energy 6 1 2014
    • (2014) J Renew Sustain Energy , vol.6 , Issue.1
    • Fernández, E.1    Rodrigo, P.2    Fernández, J.3    Almonacid, F.4    Pérez-Higueras, P.5    García-Loureiro, A.6
  • 43
    • 84984535915 scopus 로고    scopus 로고
    • Detailed effects of wind on the field performance of a 50 kW CPV demonstration plant
    • Castro M, Domínguez C, Núñez R, Antón I, Sala G, A. K. "Detailed effects of wind on the field performance of a 50 kW CPV demonstration plant". In: AIP conference proceedings, vol. 1556; 2013. pp. 256-60.
    • (2013) AIP Conference Proceedings , vol.1556 , pp. 256-260
    • Castro, M.1    Domínguez, C.2    Núñez, R.3    Antón, I.4    Sala, G.5    A, K.6
  • 44
    • 85006065074 scopus 로고    scopus 로고
    • Comparison of methods for estimating the solar cell temperature and their influence in the calculation of the electrical parameters in a HCPV module
    • E.F. Fernandez, F. Almonacid, L. Micheli, and T. Mallick Comparison of methods for estimating the solar cell temperature and their influence in the calculation of the electrical parameters in a HCPV module AIP Conf Proc 1616 2014 183 186
    • (2014) AIP Conf Proc , vol.1616 , pp. 183-186
    • Fernandez, E.F.1    Almonacid, F.2    Micheli, L.3    Mallick, T.4
  • 45
    • 84876092251 scopus 로고    scopus 로고
    • Estimating the maximum power of a high concentrator photovoltaic (HCPV) module using an artificial neural network
    • F. Almonacid, E.F. Fernández, P. Rodrigo, P. Pérez-Higueras, and C. Rus-Casas Estimating the maximum power of a high concentrator photovoltaic (HCPV) module using an artificial neural network Energy 53 2013 165 172
    • (2013) Energy , vol.53 , pp. 165-172
    • Almonacid, F.1    Fernández, E.F.2    Rodrigo, P.3    Pérez-Higueras, P.4    Rus-Casas, C.5
  • 46
    • 67650178343 scopus 로고    scopus 로고
    • Spectral response and energy output of concentrator multijunction solar cells
    • G. Kinsey, and K. Edmondson Spectral response and energy output of concentrator multijunction solar cells Prog Photovoltaics Res Appl 17 5 2009 279 288
    • (2009) Prog Photovoltaics Res Appl , vol.17 , Issue.5 , pp. 279-288
    • Kinsey, G.1    Edmondson, K.2
  • 47
    • 77949655797 scopus 로고    scopus 로고
    • Energy harvesting efficiency of III-V triple-junction concentrator solar cells under realistic spectral conditions
    • S. Philipps, G. Peharz, R. Hoheisel, T. Hornung, N. Al-Abbadi, and F.B.A. Dimroth Energy harvesting efficiency of III-V triple-junction concentrator solar cells under realistic spectral conditions Sol Energy Mater Sol Cells 94 5 2010 869 877
    • (2010) Sol Energy Mater Sol Cells , vol.94 , Issue.5 , pp. 869-877
    • Philipps, S.1    Peharz, G.2    Hoheisel, R.3    Hornung, T.4    Al-Abbadi, N.5    Dimroth, F.B.A.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.