메뉴 건너뛰기




Volumn 3, Issue 8, 2015, Pages 578-579

Is glucagon needed in type 1 diabetes?

Author keywords

[No Author keywords available]

Indexed keywords

GLUCAGON; INSULIN;

EID: 84938196545     PISSN: 22138587     EISSN: 22138595     Source Type: Journal    
DOI: 10.1016/S2213-8587(15)00210-7     Document Type: Note
Times cited : (6)

References (12)
  • 1
    • 84881505727 scopus 로고    scopus 로고
    • Severe hypoglycemia and diabetic ketoacidosis in adults with type 1 diabetes: results from the T1D Exchange clinic registry
    • Weinstock RS, Xing D, Maahs DM, et al. Severe hypoglycemia and diabetic ketoacidosis in adults with type 1 diabetes: results from the T1D Exchange clinic registry. J Clin Endocrinol Metab 2013, 98:3411-3419.
    • (2013) J Clin Endocrinol Metab , vol.98 , pp. 3411-3419
    • Weinstock, R.S.1    Xing, D.2    Maahs, D.M.3
  • 2
    • 84926287781 scopus 로고    scopus 로고
    • Outpatient overnight glucose control with dual-hormone artificial pancreas, single-hormone artificial pancreas, or conventional insulin pump therapy in children and adolescents with type 1 diabetes: an open-label, randomised controlled trial
    • published online June 9.
    • Haidar A, Legault L, Matteau-Pelletier L Outpatient overnight glucose control with dual-hormone artificial pancreas, single-hormone artificial pancreas, or conventional insulin pump therapy in children and adolescents with type 1 diabetes: an open-label, randomised controlled trial. Lancet Diabetes Endocrinol 2015, published online June 9. http://dx.doi.org/10.1016/S2213-8587(15)00141-2.
    • (2015) Lancet Diabetes Endocrinol
    • Haidar, A.1    Legault, L.2    Matteau-Pelletier, L.3
  • 3
    • 77956071742 scopus 로고    scopus 로고
    • Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes
    • Castle JR, Engle JM, El Youssef J, et al. Novel use of glucagon in a closed-loop system for prevention of hypoglycemia in type 1 diabetes. Diabetes Care 2010, 33:1282-1287.
    • (2010) Diabetes Care , vol.33 , pp. 1282-1287
    • Castle, J.R.1    Engle, J.M.2    El Youssef, J.3
  • 4
    • 84907469976 scopus 로고    scopus 로고
    • Automated control of an adaptive bihormonal, dual-sensor artificial pancreas and evaluation during inpatient studies
    • Jacobs PG, El Youssef J, Castle J, et al. Automated control of an adaptive bihormonal, dual-sensor artificial pancreas and evaluation during inpatient studies. IEEE Trans Biomed Eng 2014, 61:2569-2581.
    • (2014) IEEE Trans Biomed Eng , vol.61 , pp. 2569-2581
    • Jacobs, P.G.1    El Youssef, J.2    Castle, J.3
  • 5
    • 84926287781 scopus 로고    scopus 로고
    • Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial
    • Haidar A, Legault L, Messier V, Mitre TM, Leroux C, Rabasa-Lhoret R Comparison of dual-hormone artificial pancreas, single-hormone artificial pancreas, and conventional insulin pump therapy for glycaemic control in patients with type 1 diabetes: an open-label randomised controlled crossover trial. Lancet Diabetes Endocrinol 2015, 3:17-26.
    • (2015) Lancet Diabetes Endocrinol , vol.3 , pp. 17-26
    • Haidar, A.1    Legault, L.2    Messier, V.3    Mitre, T.M.4    Leroux, C.5    Rabasa-Lhoret, R.6
  • 6
    • 84896888057 scopus 로고    scopus 로고
    • Feasibility of a portable bihormonal closed-loop system to control glucose excursions at home under free-living conditions for 48 hours
    • Van Bon AC, Luijf YM, Koebrugge R, Koops R, Hoekstra JB, DeVries JH Feasibility of a portable bihormonal closed-loop system to control glucose excursions at home under free-living conditions for 48 hours. Diabetes Technol Ther 2014, 16:131-136.
    • (2014) Diabetes Technol Ther , vol.16 , pp. 131-136
    • Van Bon, A.C.1    Luijf, Y.M.2    Koebrugge, R.3    Koops, R.4    Hoekstra, J.B.5    DeVries, J.H.6
  • 7
    • 84904574791 scopus 로고    scopus 로고
    • Outpatient glycemic control with a bionic pancreas in type 1 diabetes
    • Russell SJ, El-Khatib FH, Sinha M, et al. Outpatient glycemic control with a bionic pancreas in type 1 diabetes. N Engl J Med 2014, 371:313-325.
    • (2014) N Engl J Med , vol.371 , pp. 313-325
    • Russell, S.J.1    El-Khatib, F.H.2    Sinha, M.3
  • 8
    • 0031784896 scopus 로고    scopus 로고
    • Variability of the metabolic effect of soluble insulin and the rapid-acting insulin analog insulin aspart
    • Heinemann L, Weyer C, Rauhaus M, Heinrichs S, Heise T Variability of the metabolic effect of soluble insulin and the rapid-acting insulin analog insulin aspart. Diabetes Care 1998, 21:1910-1914.
    • (1998) Diabetes Care , vol.21 , pp. 1910-1914
    • Heinemann, L.1    Weyer, C.2    Rauhaus, M.3    Heinrichs, S.4    Heise, T.5
  • 9
    • 84898444019 scopus 로고    scopus 로고
    • The artificial pancreas: current status and future prospects in the management of diabetes
    • Peyser T, Dassau E, Breton M, Skyler JS The artificial pancreas: current status and future prospects in the management of diabetes. Ann N Y Acad Sci 2014, 1311:102-123.
    • (2014) Ann N Y Acad Sci , vol.1311 , pp. 102-123
    • Peyser, T.1    Dassau, E.2    Breton, M.3    Skyler, J.S.4
  • 10
    • 84903551043 scopus 로고    scopus 로고
    • Safety of outpatient closed-loop control: first randomized crossover trials of a wearable artificial pancreas
    • Kovatchev BP, Renard E, Cobelli C, et al. Safety of outpatient closed-loop control: first randomized crossover trials of a wearable artificial pancreas. Diabetes Care 2014, 37:1789-1796.
    • (2014) Diabetes Care , vol.37 , pp. 1789-1796
    • Kovatchev, B.P.1    Renard, E.2    Cobelli, C.3
  • 11
    • 84903547471 scopus 로고    scopus 로고
    • Day and night home closed-loop insulin delivery in adults with type 1 diabetes: three-center randomized crossover study
    • Leelarathna L, Dellweg S, Mader JK, et al. Day and night home closed-loop insulin delivery in adults with type 1 diabetes: three-center randomized crossover study. Diabetes Care 2014, 37:1931-1937.
    • (2014) Diabetes Care , vol.37 , pp. 1931-1937
    • Leelarathna, L.1    Dellweg, S.2    Mader, J.K.3
  • 12
    • 84910135134 scopus 로고    scopus 로고
    • MD-Logic overnight control for 6 weeks of home use in patients with type 1 diabetes: randomized crossover trial
    • Nimri R, Muller I, Atlas E, et al. MD-Logic overnight control for 6 weeks of home use in patients with type 1 diabetes: randomized crossover trial. Diabetes Care 2014, 37:3025-3032.
    • (2014) Diabetes Care , vol.37 , pp. 3025-3032
    • Nimri, R.1    Muller, I.2    Atlas, E.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.