-
1
-
-
0037138743
-
Nonsteroidal anti-inflammatory drugs as anticancer agents: Mechanistic, pharmacologic, and clinical issues
-
1:CAS:528:DC%2BD38Xit1ygtb8%3D
-
Thun MJ, Henley SJ, Patrono C (2002) Nonsteroidal anti-inflammatory drugs as anticancer agents: mechanistic, pharmacologic, and clinical issues. J Natl Cancer Inst 94:252-266
-
(2002)
J Natl Cancer Inst
, vol.94
, pp. 252-266
-
-
Thun, M.J.1
Henley, S.J.2
Patrono, C.3
-
2
-
-
0000892101
-
Analgesic-antipyretic and anti-inflammatory agents and drugs employed in the treatment of gout
-
J.G. Hardman L.E. Limbird A.G. Gilman (eds) 10 McGraw-Hill New York
-
Roberts LJ, Morrow JD (2011) Analgesic-antipyretic and anti-inflammatory agents and drugs employed in the treatment of gout. In: Hardman JG, Limbird LE, Gilman AG (eds) Goodman & Gilman's the pharmacological basis of therapeutics, 10th edn. McGraw-Hill, New York, pp 703-705
-
(2011)
Goodman & Gilman's the Pharmacological Basis of Therapeutics
, pp. 703-705
-
-
Roberts, L.J.1
Morrow, J.D.2
-
3
-
-
0015237292
-
Inhibition of prostaglandin synthesis as a mechanism of action for the aspirin-like drugs
-
1:CAS:528:DyaE3MXltVyjur4%3D
-
Vane JR (1971) Inhibition of prostaglandin synthesis as a mechanism of action for the aspirin-like drugs. Nat New Biol 231:232-235
-
(1971)
Nat New Biol
, vol.231
, pp. 232-235
-
-
Vane, J.R.1
-
4
-
-
24644505386
-
Ecotoxicity of naproxen and its phototransformation products
-
1:CAS:528:DC%2BD2MXhtVWhtbvF
-
Isidori M, Lavorgna M, Nardelli A, Parrella A, Previtera L, Rubino M (2005) Ecotoxicity of naproxen and its phototransformation products. Sci Total Environ 348:93-101
-
(2005)
Sci Total Environ
, vol.348
, pp. 93-101
-
-
Isidori, M.1
Lavorgna, M.2
Nardelli, A.3
Parrella, A.4
Previtera, L.5
Rubino, M.6
-
5
-
-
19444369552
-
Determination of non-steroidal anti-inflammatory drug (NSAIDs) residues in water samples
-
1:CAS:528:DC%2BD2MXkslSksr4%3D
-
Kosjek T, Health E, Krbavčič A (2005) Determination of non-steroidal anti-inflammatory drug (NSAIDs) residues in water samples. Environ Int 31:679-685
-
(2005)
Environ Int
, vol.31
, pp. 679-685
-
-
Kosjek, T.1
Health, E.2
Krbavčič, A.3
-
6
-
-
0033551872
-
Glycation of human serum albumin by acylglucuronides of nonsteroidal anti-inflammatory drugs of the series of phenylpropionates
-
Georges H, Jarecki I, Netter P, Magdalou J, Lapicque F (1999) Glycation of human serum albumin by acylglucuronides of nonsteroidal anti-inflammatory drugs of the series of phenylpropionates. Life Sci 65:151-156
-
(1999)
Life Sci
, vol.65
, pp. 151-156
-
-
Georges, H.1
Jarecki, I.2
Netter, P.3
Magdalou, J.4
Lapicque, F.5
-
7
-
-
71649083366
-
Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase dispersion-HPLC
-
1:CAS:528:DC%2BD1MXhsFGhurnM
-
Aguilar-Arteaga K, Rodriguez JA, Miranda JM, Medina J, Barrado E (2010) Determination of non-steroidal anti-inflammatory drugs in wastewaters by magnetic matrix solid phase dispersion-HPLC. Talanta 80:1152-1157
-
(2010)
Talanta
, vol.80
, pp. 1152-1157
-
-
Aguilar-Arteaga, K.1
Rodriguez, J.A.2
Miranda, J.M.3
Medina, J.4
Barrado, E.5
-
8
-
-
79951812156
-
An analytical method for the simultaneous trace determination of acidic pharmaceuticals and phenolic endocrine disrupting chemicals in wastewater and sewage sludge by gas chromatography-mass spectrometry
-
1:CAS:528:DC%2BC3MXntVen
-
Samaras VG, Thomaidis NS, Stasinakis AS, Lekkas TD (2011) An analytical method for the simultaneous trace determination of acidic pharmaceuticals and phenolic endocrine disrupting chemicals in wastewater and sewage sludge by gas chromatography-mass spectrometry. Anal Bioanal Chem 399:2549-2561
-
(2011)
Anal Bioanal Chem
, vol.399
, pp. 2549-2561
-
-
Samaras, V.G.1
Thomaidis, N.S.2
Stasinakis, A.S.3
Lekkas, T.D.4
-
9
-
-
1342283702
-
-1 concentration range
-
-1 concentration range. Electrophoresis 25:428-436
-
(2004)
Electrophoresis
, vol.25
, pp. 428-436
-
-
Macià A, B.1
-
10
-
-
79958109182
-
Electromembrane extraction (EME) and HPLC determination of non-steroidal anti-inflammatory drugs (NSAIDs) in wastewater samples
-
Payán MR, López MAB, Torres RF, Navarro MV, Mochón MC (2011) Electromembrane extraction (EME) and HPLC determination of non-steroidal anti-inflammatory drugs (NSAIDs) in wastewater samples. Talanta 85:394-399
-
(2011)
Talanta
, vol.85
, pp. 394-399
-
-
Payán, M.R.1
López, M.A.B.2
Torres, R.F.3
Navarro, M.V.4
Mochón, M.C.5
-
11
-
-
9644257157
-
Suitability of hollow fiber liquid-phase microextraction for the determination of acidic pharmaceuticals in wastewater by liquid chromatography-electrospray tandem mass spectrometry without matrix effects
-
Quintana JB, Rodil R, Reemtsma T (2004) Suitability of hollow fiber liquid-phase microextraction for the determination of acidic pharmaceuticals in wastewater by liquid chromatography-electrospray tandem mass spectrometry without matrix effects. J Chromatogr A 1601:19-26
-
(2004)
J Chromatogr A
, vol.1601
, pp. 19-26
-
-
Quintana, J.B.1
Rodil, R.2
Reemtsma, T.3
-
12
-
-
33745948767
-
Determination of non-steroidal anti-inflammatory drugs in natural waters using off-line and on-line SPE followed by LC coupled with DAD-MS
-
1:CAS:528:DC%2BD2sXhslKhsLs%3D
-
Kot-Wasik A, Debska J, Wasik A, Namies̈nik J (2006) Determination of non-steroidal anti-inflammatory drugs in natural waters using off-line and on-line SPE followed by LC coupled with DAD-MS. Chromatographia 64:13-21
-
(2006)
Chromatographia
, vol.64
, pp. 13-21
-
-
Kot-Wasik, A.1
Debska, J.2
Wasik, A.3
Namies̈nik, J.4
-
13
-
-
46549084677
-
Selective trace analysis of diclofenac in surface and wastewater samples using solid-phase extraction with a new molecularly imprinted polymer
-
1:CAS:528:DC%2BD1cXnt1yjsLc%3D
-
Sun Z, Schüssler W, Sengl M, Niessner R, Knopp D (2008) Selective trace analysis of diclofenac in surface and wastewater samples using solid-phase extraction with a new molecularly imprinted polymer. Anal Chim Acta 620:73-81
-
(2008)
Anal Chim Acta
, vol.620
, pp. 73-81
-
-
Sun, Z.1
Schüssler, W.2
Sengl, M.3
Niessner, R.4
Knopp, D.5
-
14
-
-
77956061875
-
Application of a novel solid-phase-extraction sampler and ultra-performance liquid chromatography quadrupole-time-of-flight mass spectrometry for determination of pharmaceutical residues in surface sea water
-
Magnér J, Filipovic M, Alsberg T (2010) Application of a novel solid-phase-extraction sampler and ultra-performance liquid chromatography quadrupole-time-of-flight mass spectrometry for determination of pharmaceutical residues in surface sea water. Chemosphere 80:1255-1260
-
(2010)
Chemosphere
, vol.80
, pp. 1255-1260
-
-
Magnér, J.1
Filipovic, M.2
Alsberg, T.3
-
15
-
-
80051545923
-
Synthesis and characterization of polydimethylsiloxane-cyanopropyltriethoxysilane-derived hybrid coating for stir bar sorptive extraction
-
1:CAS:528:DC%2BC3MXosFait7w%3D
-
Ibrahim WAW, Keyon ASA, Prastomo N, Matsuda A (2011) Synthesis and characterization of polydimethylsiloxane-cyanopropyltriethoxysilane-derived hybrid coating for stir bar sorptive extraction. J Sol-gel Sci Technol 59:128-134
-
(2011)
J Sol-gel Sci Technol
, vol.59
, pp. 128-134
-
-
Ibrahim, W.A.W.1
Keyon, A.S.A.2
Prastomo, N.3
Matsuda, A.4
-
16
-
-
53849146339
-
Advances in stir bar sorptive extraction for the determination of acidic pharmaceuticals in environmental water matrices: Comparison between polyurethane and polydimethylsiloxane polymeric phases
-
1:CAS:528:DC%2BD1cXht1Kls77E
-
Silva ARM, Portugal FCM, Nogueira JMF (2008) Advances in stir bar sorptive extraction for the determination of acidic pharmaceuticals in environmental water matrices: comparison between polyurethane and polydimethylsiloxane polymeric phases. J Chromatogr A 1209:10-16
-
(2008)
J Chromatogr A
, vol.1209
, pp. 10-16
-
-
Silva, A.R.M.1
Portugal, F.C.M.2
Nogueira, J.M.F.3
-
17
-
-
0040736140
-
Stir bar sorptive extraction (SBSE), a novel extraction technique for aqueous samples: Theory and principles
-
1:CAS:528:DyaK1MXns1ygsL0%3D
-
Baltussen E, Sandra P, David F, Cramers C (1999) Stir bar sorptive extraction (SBSE), a novel extraction technique for aqueous samples: theory and principles. J Microcolumn Sep 11:737-747
-
(1999)
J Microcolumn Sep
, vol.11
, pp. 737-747
-
-
Baltussen, E.1
Sandra, P.2
David, F.3
Cramers, C.4
-
18
-
-
84872373250
-
A sol-gel polydimethylsiloxane/polythiophene coated stir bar sorptive extraction combined with gas chromatography-flame photometric detection for the determination of organophosphorus pesticides in environmental water samples
-
1:CAS:528:DC%2BC3sXntFyntA%3D%3D
-
Hu C, He M, Chen BB, Hu B (2013) A sol-gel polydimethylsiloxane/polythiophene coated stir bar sorptive extraction combined with gas chromatography-flame photometric detection for the determination of organophosphorus pesticides in environmental water samples. J Chromatogr A 1275:25-31
-
(2013)
J Chromatogr A
, vol.1275
, pp. 25-31
-
-
Hu, C.1
He, M.2
Chen, B.B.3
Hu, B.4
-
19
-
-
84869871353
-
Using a novel sol-gel stir bar sorptive extraction method for the analysis of steroid hormones in water by laser diode thermal desorption/atmospheric chemical ionization tandem mass spectrometry
-
Duy SV, Fayad PB, Barbeau B, Prévost M, Sauvé S (2012) Using a novel sol-gel stir bar sorptive extraction method for the analysis of steroid hormones in water by laser diode thermal desorption/atmospheric chemical ionization tandem mass spectrometry. Talanta 101:337-345
-
(2012)
Talanta
, vol.101
, pp. 337-345
-
-
Duy, S.V.1
Fayad, P.B.2
Barbeau, B.3
Prévost, M.4
Sauvé, S.5
-
20
-
-
84886772822
-
Preparation of a polar monolithic coating for stir bar sorptive extraction of emerging contaminants from wastewaters
-
1:CAS:528:DC%2BC3sXnslalsb4%3D
-
Gilart N, Cormack PAG, Marcé RM, Borrull F, Fontanals N (2013) Preparation of a polar monolithic coating for stir bar sorptive extraction of emerging contaminants from wastewaters. J Chromatogr A 1295:42-47
-
(2013)
J Chromatogr A
, vol.1295
, pp. 42-47
-
-
Gilart, N.1
Cormack, P.A.G.2
Marcé, R.M.3
Borrull, F.4
Fontanals, N.5
-
21
-
-
84874985923
-
Sensitive monitoring of penicillin antibiotics in milk and honey treated by stir bar sorptive extraction based on monolith and LC-electrospray MS detection
-
1:CAS:528:DC%2BC3sXhvFWlsbw%3D
-
Huang XJ, Chen LL, Chen M, Yuan DX, Nong SY (2013) Sensitive monitoring of penicillin antibiotics in milk and honey treated by stir bar sorptive extraction based on monolith and LC-electrospray MS detection. J Sep Sci 36:907-915
-
(2013)
J Sep Sci
, vol.36
, pp. 907-915
-
-
Huang, X.J.1
Chen, L.L.2
Chen, M.3
Yuan, D.X.4
Nong, S.Y.5
-
22
-
-
84861163568
-
Highly selective stir bar coated with dummy molecularly imprinted polymers for trace analysis of bisphenol A in milk
-
1:CAS:528:DC%2BC38XmvFCiur0%3D
-
Zhan W, Wei FD, Xu GH, Cai Z, Du SH, Zhou XM, Li F, Hu Q (2012) Highly selective stir bar coated with dummy molecularly imprinted polymers for trace analysis of bisphenol A in milk. J Sep Sci 35:1036-1043
-
(2012)
J Sep Sci
, vol.35
, pp. 1036-1043
-
-
Zhan, W.1
Wei, F.D.2
Xu, G.H.3
Cai, Z.4
Du, S.H.5
Zhou, X.M.6
Li, F.7
Hu, Q.8
-
23
-
-
0036809725
-
Ionic liquid (molten salt) phase organometallic catalysis
-
1:CAS:528:DC%2BD38Xmt1Oqur4%3D
-
Dupont J, de Souza RF, Suarez PAZ (2002) Ionic liquid (molten salt) phase organometallic catalysis. Chem Rev 102:3667-3691
-
(2002)
Chem Rev
, vol.102
, pp. 3667-3691
-
-
Dupont, J.1
De Souza, R.F.2
Suarez, P.A.Z.3
-
24
-
-
79959445817
-
A correlation-based predictor for pair-association in ionic liquids
-
1:CAS:528:DC%2BC3MXnslOnuro%3D
-
Maiti A, Rogers RD (2011) A correlation-based predictor for pair-association in ionic liquids. Phys Chem Phys 13:12138-12145
-
(2011)
Phys Chem Phys
, vol.13
, pp. 12138-12145
-
-
Maiti, A.1
Rogers, R.D.2
-
26
-
-
47649106163
-
Ionic liquid-based dynamic liquid-phase microextraction: Application to the determination of anti-inflammatory drugs in urine samples
-
1:CAS:528:DC%2BD1cXptVOisLg%3D
-
Cruz-Vera M, Lucena R, Cárdenas S, Valcárcel M (2008) Ionic liquid-based dynamic liquid-phase microextraction: application to the determination of anti-inflammatory drugs in urine samples. J Chromatogr A 1202:1-7
-
(2008)
J Chromatogr A
, vol.1202
, pp. 1-7
-
-
Cruz-Vera, M.1
Lucena, R.2
Cárdenas, S.3
Valcárcel, M.4
-
27
-
-
67249156720
-
Ionic liquid-mediated sol-gel coatings for capillary microextraction
-
1:CAS:528:DC%2BD1MXnsFKlsL4%3D
-
Shearrow AM, Harris GA, Fang L, Sekhar PK, Nguyen LT, Turner EB, Bhansali S, Malik A (2009) Ionic liquid-mediated sol-gel coatings for capillary microextraction. J Chromatogr A 1216:5449-5458
-
(2009)
J Chromatogr A
, vol.1216
, pp. 5449-5458
-
-
Shearrow, A.M.1
Harris, G.A.2
Fang, L.3
Sekhar, P.K.4
Nguyen, L.T.5
Turner, E.B.6
Bhansali, S.7
Malik, A.8
-
28
-
-
84879879324
-
Determination of organophosphate esters in water samples using an ionic liquid-based sol-gel fiber for headspace solid-phase microextraction coupled to gas chromatography-flame photometric detector
-
1:CAS:528:DC%2BC3sXltVensrg%3D
-
Gao Z, Deng YH, Hu XB, Yang SG, Sun C, He H (2013) Determination of organophosphate esters in water samples using an ionic liquid-based sol-gel fiber for headspace solid-phase microextraction coupled to gas chromatography-flame photometric detector. J Chromatogr A 1300:141-150
-
(2013)
J Chromatogr A
, vol.1300
, pp. 141-150
-
-
Gao, Z.1
Deng, Y.H.2
Hu, X.B.3
Yang, S.G.4
Sun, C.5
He, H.6
-
29
-
-
67349179998
-
Ionic liquids as desorption solvents and memory effect suppressors in heterocyclic aromatic amines determination by SPME-HPLC fluorescence
-
Martín-Calero A, Ayala JH, González V, Afonso AM (2009) Ionic liquids as desorption solvents and memory effect suppressors in heterocyclic aromatic amines determination by SPME-HPLC fluorescence. Anal Bioanal Chem 394:937-946
-
(2009)
Anal Bioanal Chem
, vol.394
, pp. 937-946
-
-
Martín-Calero, A.1
Ayala, J.H.2
González, V.3
Afonso, A.M.4
-
30
-
-
79955969324
-
Preparation and characterization of novel crown ether functionalized ionic liquid-based solid-phase microextraction coatings by sol-gel technology
-
1:CAS:528:DC%2BC3MXmsFantL0%3D
-
Zhou X, Xie PF, Wang J, Zhang BB, Liu MM, Liu HL, Feng XH (2011) Preparation and characterization of novel crown ether functionalized ionic liquid-based solid-phase microextraction coatings by sol-gel technology. J Chromatogr A 1218:3571-3580
-
(2011)
J Chromatogr A
, vol.1218
, pp. 3571-3580
-
-
Zhou, X.1
Xie, P.F.2
Wang, J.3
Zhang, B.B.4
Liu, M.M.5
Liu, H.L.6
Feng, X.H.7
-
31
-
-
84879890486
-
A solid phase microextraction coating based on ionic liquid sol-gel technique for determination of benzene, toluene, ethylbenzene and o-xylene in water samples using gas chromatography flame ionization detector
-
1:CAS:528:DC%2BC3sXls1Cisbk%3D
-
Sarafraz-Yazdi A, Vatani H (2013) A solid phase microextraction coating based on ionic liquid sol-gel technique for determination of benzene, toluene, ethylbenzene and o-xylene in water samples using gas chromatography flame ionization detector. J Chromatogr A 1300:104-111
-
(2013)
J Chromatogr A
, vol.1300
, pp. 104-111
-
-
Sarafraz-Yazdi, A.1
Vatani, H.2
-
32
-
-
65549135273
-
Preparation of ionic liquid based solid-phase microextraction fiber and its application to forensic determination of methamphetamine and amphetamine in human urine
-
1:CAS:528:DC%2BD1MXmtFersrs%3D
-
He Y, Pohl J, Engel R, Rothman L, Thomas M (2009) Preparation of ionic liquid based solid-phase microextraction fiber and its application to forensic determination of methamphetamine and amphetamine in human urine. J Chromatogr A 1216:4824-4830
-
(2009)
J Chromatogr A
, vol.1216
, pp. 4824-4830
-
-
He, Y.1
Pohl, J.2
Engel, R.3
Rothman, L.4
Thomas, M.5
-
33
-
-
14144251196
-
Disposable ionic liquid coating for headspace solid-phase microextraction of benzene, toluene, ethylbenzene, and xylenes in paints followed by gas chromatography-flame ionization detection
-
1:CAS:528:DC%2BD2MXhslWltro%3D
-
Liu JF, Li N, Jiang GB, Li JM, Jönsson JA, Wen MJ (2005) Disposable ionic liquid coating for headspace solid-phase microextraction of benzene, toluene, ethylbenzene, and xylenes in paints followed by gas chromatography-flame ionization detection. J Chromatogr A 1066:27-32
-
(2005)
J Chromatogr A
, vol.1066
, pp. 27-32
-
-
Liu, J.F.1
Li, N.2
Jiang, G.B.3
Li, J.M.4
Jönsson, J.A.5
Wen, M.J.6
-
34
-
-
78650418216
-
A novel reusable ionic liquid chemically bonded fused-silica fiber for headspace solid-phase microextraction/gas chromatography-flame ionization detection of methyl tert-butyl ether in a gasoline sample
-
1:CAS:528:DC%2BC3cXhs1ags7vP
-
Amini R, Rouhollahi A, Adibi M, Mehdinia A (2011) A novel reusable ionic liquid chemically bonded fused-silica fiber for headspace solid-phase microextraction/gas chromatography-flame ionization detection of methyl tert-butyl ether in a gasoline sample. J Chromatogr A 1218:130-136
-
(2011)
J Chromatogr A
, vol.1218
, pp. 130-136
-
-
Amini, R.1
Rouhollahi, A.2
Adibi, M.3
Mehdinia, A.4
-
35
-
-
72849144212
-
Bonded ionic liquid polymeric material for solid-phase microextraction GC analysis
-
1:CAS:528:DC%2BD1MXhsVehtbjO
-
Wanigasekara E, Perera S, Crank JA, Sidisky L, Shirey R, Berthod A, Armstrong DW (2010) Bonded ionic liquid polymeric material for solid-phase microextraction GC analysis. Anal Bioanal Chem 396:511-524
-
(2010)
Anal Bioanal Chem
, vol.396
, pp. 511-524
-
-
Wanigasekara, E.1
Perera, S.2
Crank, J.A.3
Sidisky, L.4
Shirey, R.5
Berthod, A.6
Armstrong, D.W.7
-
36
-
-
78649326175
-
Innovative chemically bonded ionic liquids-based sol-gel coatings as highly porous, stable and selective stationary phases for solid phase microextraction
-
1:CAS:528:DC%2BC3cXhsVGitL%2FE
-
Liu MM, Zhou X, Chen YY, Liu HL, Feng XH, Qiu GH, Liu F, Zeng ZR (2010) Innovative chemically bonded ionic liquids-based sol-gel coatings as highly porous, stable and selective stationary phases for solid phase microextraction. Anal Chim Acta 683:96-106
-
(2010)
Anal Chim Acta
, vol.683
, pp. 96-106
-
-
Liu, M.M.1
Zhou, X.2
Chen, Y.Y.3
Liu, H.L.4
Feng, X.H.5
Qiu, G.H.6
Liu, F.7
Zeng, Z.R.8
-
37
-
-
79956113568
-
Preparation of novel ionic liquids-based sol-gel coatings for solid-phase microextraction
-
1:CAS:528:DC%2BC3cXhsVSku7%2FF
-
Zhou X, Shang J, Liu MM, Liu HL, Hao R, Feng XH, Liu F (2010) Preparation of novel ionic liquids-based sol-gel coatings for solid-phase microextraction. Acta Chim Sinica 68:1749-1757
-
(2010)
Acta Chim Sinica
, vol.68
, pp. 1749-1757
-
-
Zhou, X.1
Shang, J.2
Liu, M.M.3
Liu, H.L.4
Hao, R.5
Feng, X.H.6
Liu, F.7
-
38
-
-
84856354034
-
Thermally stable ionic liquid-based sol-gel coating for ultrasonic extraction solid-phase microextraction-gas chromatography determination of phthalate esters in agricultural plastic films
-
1:CAS:528:DC%2BC38XhsFGmsbk%3D
-
Zhou X, Shao X, Shu JJ, Liu MM, Liu HL, Feng XH, Liu F (2012) Thermally stable ionic liquid-based sol-gel coating for ultrasonic extraction solid-phase microextraction-gas chromatography determination of phthalate esters in agricultural plastic films. Talanta 89:129-135
-
(2012)
Talanta
, vol.89
, pp. 129-135
-
-
Zhou, X.1
Shao, X.2
Shu, J.J.3
Liu, M.M.4
Liu, H.L.5
Feng, X.H.6
Liu, F.7
-
39
-
-
74849095336
-
Determination of water pollutants by direct-immersion solid-phase microextraction using polymeric ionic liquid coatings
-
López-Darias J, Pino V, Anderson JL, Graham CM, Afonso AM (2010) Determination of water pollutants by direct-immersion solid-phase microextraction using polymeric ionic liquid coatings. J Chromatogr A 1217:1236-1243
-
(2010)
J Chromatogr A
, vol.1217
, pp. 1236-1243
-
-
López-Darias, J.1
Pino, V.2
Anderson, J.L.3
Graham, C.M.4
Afonso, A.M.5
-
40
-
-
77958105740
-
Utilization of a benzyl functionalized polymeric ionic liquid for the sensitive determination of polycyclic aromatic hydrocarbons, parabens and alkylphenols in waters using solid-phase microextraction coupled to gas chromatography-flame ionization detection
-
López-Darias J, Pino V, Meng YJ, Anderson JL, Afonso AM (2010) Utilization of a benzyl functionalized polymeric ionic liquid for the sensitive determination of polycyclic aromatic hydrocarbons, parabens and alkylphenols in waters using solid-phase microextraction coupled to gas chromatography-flame ionization detection. J Chromatogr A 1217:7189-7197
-
(2010)
J Chromatogr A
, vol.1217
, pp. 7189-7197
-
-
López-Darias, J.1
Pino, V.2
Meng, Y.J.3
Anderson, J.L.4
Afonso, A.M.5
-
41
-
-
79151473365
-
Role of counteranions in polymeric ionic liquid-based solid-phase microextraction coatings for the selective extraction of polar compounds
-
1:CAS:528:DC%2BC3MXhtlKkt7s%3D
-
Meng YJ, Pino V, Anderson JL (2011) Role of counteranions in polymeric ionic liquid-based solid-phase microextraction coatings for the selective extraction of polar compounds. Anal Chim Acta 687:141-149
-
(2011)
Anal Chim Acta
, vol.687
, pp. 141-149
-
-
Meng, Y.J.1
Pino, V.2
Anderson, J.L.3
-
42
-
-
77956650064
-
Tuning the selectivity of polymeric ionic liquid sorbent coatings for the extraction of polycyclic aromatic hydrocarbons using solid-phase microextraction
-
1:CAS:528:DC%2BC3cXhtFygurjP
-
Meng YJ, Anderson JL (2010) Tuning the selectivity of polymeric ionic liquid sorbent coatings for the extraction of polycyclic aromatic hydrocarbons using solid-phase microextraction. J Chromatogr A 1217:6143-6152
-
(2010)
J Chromatogr A
, vol.1217
, pp. 6143-6152
-
-
Meng, Y.J.1
Anderson, J.L.2
-
43
-
-
64749116811
-
Preparation of polydimethylsiloxane/beta-cyclodextrin/divinylbenzene coated "dumbbell-shaped" stir bar and its application to the analysis of polycyclic aromatic hydrocarbons and polycyclic aromatic sulfur heterocycles compounds in lake water and soil by high performance liquid chromatography
-
1:CAS:528:DC%2BD1MXltVWhsrk%3D
-
Yu CH, Yao ZM, Hu B (2009) Preparation of polydimethylsiloxane/beta-cyclodextrin/divinylbenzene coated "dumbbell-shaped" stir bar and its application to the analysis of polycyclic aromatic hydrocarbons and polycyclic aromatic sulfur heterocycles compounds in lake water and soil by high performance liquid chromatography. Anal Chim Acta 641:75-82
-
(2009)
Anal Chim Acta
, vol.641
, pp. 75-82
-
-
Yu, C.H.1
Yao, Z.M.2
Hu, B.3
-
44
-
-
84857357350
-
C18-coated stir bar sorptive extraction combined with high performance liquid chromatography-electrospray tandem mass spectrometry for the analysis of sulfonamides in milk and milk powder
-
1:CAS:528:DC%2BC38Xis1ens7o%3D
-
Yu CH, Hu B (2012) C18-coated stir bar sorptive extraction combined with high performance liquid chromatography-electrospray tandem mass spectrometry for the analysis of sulfonamides in milk and milk powder. Talanta 90:77-84
-
(2012)
Talanta
, vol.90
, pp. 77-84
-
-
Yu, C.H.1
Hu, B.2
-
45
-
-
79251548911
-
Cleanup strategies and advantages in the determination of several therapeutic classes of pharmaceuticals in wastewater samples by SPE-LC-MS/MS
-
1:CAS:528:DC%2BC3cXhtlSjtbbK
-
Sousa MA, Goncalves C, Cunha E, Hajšlová J, Alpendurada MF (2011) Cleanup strategies and advantages in the determination of several therapeutic classes of pharmaceuticals in wastewater samples by SPE-LC-MS/MS. Anal Bioanal Chem 399:807-822
-
(2011)
Anal Bioanal Chem
, vol.399
, pp. 807-822
-
-
Sousa, M.A.1
Goncalves, C.2
Cunha, E.3
Hajšlová, J.4
Alpendurada, M.F.5
-
46
-
-
79956113981
-
Simultaneous determination of non-steroidal anti-inflammatory drugs in river water samples by liquid chromatography-tandem mass spectrometry using molecularly imprinted polymers as a pretreatment column
-
1:CAS:528:DC%2BC3MXmsFWrtbY%3D
-
Hoshina K, Horiyama S, Matsunaga H, Haginaka J (2011) Simultaneous determination of non-steroidal anti-inflammatory drugs in river water samples by liquid chromatography-tandem mass spectrometry using molecularly imprinted polymers as a pretreatment column. J Pharmaceut Biomed 55:916-922
-
(2011)
J Pharmaceut Biomed
, vol.55
, pp. 916-922
-
-
Hoshina, K.1
Horiyama, S.2
Matsunaga, H.3
Haginaka, J.4
-
47
-
-
80755188865
-
An anionic exchange stir rod sorptive extraction based on monolithic material for the extraction of non-steroidal anti-inflammatory drugs in environmental aqueous samples
-
1:CAS:528:DC%2BC3MXhsVaqt7%2FJ
-
Luo YB, Zheng HB, Wang JX, Gao Q, Yu QW, Feng YQ (2011) An anionic exchange stir rod sorptive extraction based on monolithic material for the extraction of non-steroidal anti-inflammatory drugs in environmental aqueous samples. Talanta 86:103-108
-
(2011)
Talanta
, vol.86
, pp. 103-108
-
-
Luo, Y.B.1
Zheng, H.B.2
Wang, J.X.3
Gao, Q.4
Yu, Q.W.5
Feng, Y.Q.6
-
48
-
-
8144229323
-
In-tube solid phase microextraction using a beta-cyclodextrin coated capillary coupled to high performance liquid chromatography for determination of non-steroidal anti-inflammatory drugs in urine samples
-
1:CAS:528:DC%2BD2cXpslyjs7s%3D
-
Fan Y, Feng YQ, Da SL, Wang ZH (2005) In-tube solid phase microextraction using a beta-cyclodextrin coated capillary coupled to high performance liquid chromatography for determination of non-steroidal anti-inflammatory drugs in urine samples. Talanta 65:111-117
-
(2005)
Talanta
, vol.65
, pp. 111-117
-
-
Fan, Y.1
Feng, Y.Q.2
Da, S.L.3
Wang, Z.H.4
|