메뉴 건너뛰기




Volumn 30, Issue 11, 2015, Pages 6191-6202

Magnetic Field Energy Harvesting under Overhead Power Lines

Author keywords

Condition monitoring; energy harvesting; inductive coil; overhead power line

Indexed keywords

BALLOONS; CONDITION MONITORING; COREMAKING; DEMAGNETIZATION; EDDY CURRENT TESTING; MAGNETIC FIELDS; MAGNETIC FLUX; MAGNETISM; MANGANESE;

EID: 84937123814     PISSN: 08858993     EISSN: None     Source Type: Journal    
DOI: 10.1109/TPEL.2015.2436702     Document Type: Article
Times cited : (137)

References (41)
  • 2
    • 1942439921 scopus 로고    scopus 로고
    • Modeling of icing and ice shedding onoverhead power lines based on statistical analysis of meteorological data
    • Apr.
    • K. Savadjiev and M. Farazaneh, "Modeling of icing and ice shedding onoverhead power lines based on statistical analysis of meteorological data," IEEE Trans. Power Del., vol. 19, no. 2, pp. 715-722, Apr. 2004.
    • (2004) IEEE Trans. Power Del. , vol.19 , Issue.2 , pp. 715-722
    • Savadjiev, K.1    Farazaneh, M.2
  • 3
    • 67349153353 scopus 로고    scopus 로고
    • A feasibility study on autonomous online condition monitoring of high-voltage overhead power lines
    • May
    • H. Zangl, T. Bretterklieber and G. Brasseur, "A feasibility study on autonomous online condition monitoring of high-voltage overhead power lines," IEEE Trans. Instrum. Meas., vol. 50, no. 5, pp. 1789-1796, May 2009.
    • (2009) IEEE Trans. Instrum. Meas. , vol.50 , Issue.5 , pp. 1789-1796
    • Zangl, H.1    Bretterklieber, T.2    Brasseur, G.3
  • 5
    • 77957949859 scopus 로고    scopus 로고
    • Enabling battery-lesswireless sensor operation using solar energy harvesting at locations with limited solar radiation
    • S.Bader andB.Oelmann, "Enabling battery-lesswireless sensor operation using solar energy harvesting at locations with limited solar radiation," in Proc. 4th Int. Conf. Sensor Technol. Appl., 2010, pp. 602-608.
    • (2010) Proc. 4th Int. Conf. Sensor Technol. Appl. , pp. 602-608
    • Bader, S.1    Oelmann, B.2
  • 6
    • 17044365390 scopus 로고    scopus 로고
    • Energy scavenging for mobile and wireless electronics
    • Jan.-Mar.
    • J. A. Paradiso and T. Starner, "Energy scavenging for mobile and wireless electronics," IEEE Pervasive Comput., vol. 4, no. 1, pp. 18-27, Jan.-Mar. 2005.
    • (2005) IEEE Pervasive Comput. , vol.4 , Issue.1 , pp. 18-27
    • Paradiso, J.A.1    Starner, T.2
  • 7
    • 33947371235 scopus 로고    scopus 로고
    • Enhancement of damage-detection of wind turbine blades via CWT-based approaches
    • Sep.
    • C. Tsai, C. Hsieh, and S. Huang, "Enhancement of damage-detection of wind turbine blades via CWT-based approaches," IEEE Trans. Energy Convers., vol. 21, no. 3, pp. 776-781, Sep. 2006.
    • (2006) IEEE Trans. Energy Convers. , vol.21 , Issue.3 , pp. 776-781
    • Tsai, C.1    Hsieh, C.2    Huang, S.3
  • 8
    • 84863271663 scopus 로고    scopus 로고
    • Electric field energy harvesting powered wireless sensors for smart grid
    • K. Chang, S. Kang, K. Park, and S. Shin, "Electric field energy harvesting powered wireless sensors for smart grid," J. Electr. Eng. Technol., vol. 7, no. 1, pp. 75-80, 2012.
    • (2012) J. Electr. Eng. Technol. , vol.7 , Issue.1 , pp. 75-80
    • Chang, K.1    Kang, S.2    Park, K.3    Shin, S.4
  • 9
    • 84937113940 scopus 로고    scopus 로고
    • Energy scavenging for monitoring of overhead power line networks
    • T. Keutel, X. Zhao, and O. Kanoun, "Energy scavenging for monitoring of overhead power line networks," in Proc. Int. Inst. Meas. Technol. Conf., 2009, pp. 207-211
    • (2009) Proc. Int. Inst. Meas. Technol. Conf. , pp. 207-211
    • Keutel, T.1    Zhao, X.2    Kanoun, O.3
  • 10
    • 79959303625 scopus 로고    scopus 로고
    • Strong and weak electric field interfering: Capacitive icing detection and capacitive energy harvesting on a 220-KV high-voltage overhead power line
    • Jul.
    • M. J. Moser, T. Bretterklieber, H. Zangl, and G. Brasseur, "Strong and weak electric field interfering: Capacitive icing detection and capacitive energy harvesting on a 220-KV high-voltage overhead power line," IEEE Trans. Ind. Electron., vol. 58, no. 7, pp. 2597-2604, Jul. 2011.
    • (2011) IEEE Trans. Ind. Electron. , vol.58 , Issue.7 , pp. 2597-2604
    • Moser, M.J.1    Bretterklieber, T.2    Zangl, H.3    Brasseur, G.4
  • 11
    • 82855169771 scopus 로고    scopus 로고
    • Energy harvesting devices for high voltage transmission linemonitoring
    • Jul.
    • F. Guo, H. Hayat, and J. Wang, "Energy harvesting devices for high voltage transmission linemonitoring," in Proc. Power Energy Soc.General Meeting, Jul. 2011, pp. 1-8.
    • (2011) Proc. Power Energy Soc.General Meeting , pp. 1-8
    • Guo, F.1    Hayat, H.2    Wang, J.3
  • 12
    • 84880649942 scopus 로고    scopus 로고
    • Energy harvesting for a wirelessmonitoring system of overhead high-voltage power lines
    • X. Zhao, T. Keutel, and M. Balduaf, "Energy harvesting for a wirelessmonitoring system of overhead high-voltage power lines," IET Gener., Transmiss. Distrib., vol. 7, no. 2, pp. 101-107, 2013.
    • (2013) IET Gener., Transmiss. Distrib. , vol.7 , Issue.2 , pp. 101-107
    • Zhao, X.1    Keutel, T.2    Balduaf, M.3
  • 13
    • 84924860245 scopus 로고    scopus 로고
    • Analysis model for magnetic energy harvesters
    • Aug.
    • J. Moon and S. B. Leeb, "Analysis model for magnetic energy harvesters," IEEE Trans. Power Electron., vol. 30, no. 8, pp. 4302-4311, Aug. 2015.
    • (2015) IEEE Trans. Power Electron. , vol.30 , Issue.8 , pp. 4302-4311
    • Moon, J.1    Leeb, S.B.2
  • 15
    • 80053494358 scopus 로고    scopus 로고
    • Energy harvesting of magnetic power-line noise
    • Oct.
    • K. Tashiro, H. Wakiwaka, S. Inoue, and Y. Uchiyama, "Energy harvesting of magnetic power-line noise," IEEE Trans. Magn., vol. 47, no. 10, pp. 4441-4444, Oct. 2011.
    • (2011) IEEE Trans. Magn. , vol.47 , Issue.10 , pp. 4441-4444
    • Tashiro, K.1    Wakiwaka, H.2    Inoue, S.3    Uchiyama, Y.4
  • 16
    • 84872922609 scopus 로고    scopus 로고
    • Energy harvesting for Zigbee compliant wireless sensor network nodes
    • J. P. Amaro, "Energy harvesting for Zigbee compliant wireless sensor network nodes," in Proc. 38th Annu. Conf. IEEE Ind. Electron. Soc., 2012, pp. 2583-2588.
    • (2012) Proc. 38th Annu. Conf. IEEE Ind. Electron. Soc. , pp. 2583-2588
    • Amaro, J.P.1
  • 18
    • 84883389857 scopus 로고    scopus 로고
    • Condition monitoring and diagnosis of highvoltage equipment in China - Recent progress
    • Sep./Oct.
    • C. Li, G. Ma, and B. Qi, "condition monitoring and diagnosis of highvoltage equipment in China-Recent progress," IEEE Electr. Insul. Mag., vol. 29, no. 5, pp. 71-78, Sep./Oct. 2013.
    • (2013) IEEE Electr. Insul. Mag. , vol.29 , Issue.5 , pp. 71-78
    • Li, C.1    Ma, G.2    Qi, B.3
  • 19
    • 84905109777 scopus 로고    scopus 로고
    • A comparison of real-time thermal rating systems in the U.S. and the U.K
    • Aug.
    • D. M. Green, J. P. Gentle, and K. S. Myers, "A comparison of real-time thermal rating systems in the U.S. and the U.K.," IEEE Trans. Power Del., vol. 29, no. 4, pp. 1849-1858, Aug. 2014.
    • (2014) IEEE Trans. Power Del. , vol.29 , Issue.4 , pp. 1849-1858
    • Green, D.M.1    Gentle, J.P.2    Myers, K.S.3
  • 21
    • 70449498520 scopus 로고    scopus 로고
    • Energy harvesting in substations for powering autonomous sensors
    • M. Zhu and M.D. Judd, "Energy harvesting in substations for powering autonomous sensors," in Proc. 3rd Int. Conf. Sensor Technol. Appl., 2009, pp. 246-251.
    • (2009) Proc. 3rd Int. Conf. Sensor Technol. Appl. , pp. 246-251
    • Zhu, M.1    Judd, M.D.2
  • 22
    • 70449643009 scopus 로고    scopus 로고
    • Alternative power sources for autonomous sensors in high voltage plant
    • M. Zhu and P.C. Baker, "Alternative power sources for autonomous sensors in high voltage plant," in Proc. IEEE Electr. Insul. Conf., 2009, pp. 36-40.
    • (2009) Proc. IEEE Electr. Insul. Conf. , pp. 36-40
    • Zhu, M.1    Baker, P.C.2
  • 23
    • 84877294932 scopus 로고    scopus 로고
    • Harvesting energy from magnetic fields to power condition monitoring sensors
    • Jun.
    • N. M. Roscoe and M. D. Judd, "Harvesting energy from magnetic fields to power condition monitoring sensors," IEEE Sensors J., vol. 13, no. 6, pp. 2263-2270, Jun. 2013.
    • (2013) IEEE Sensors J. , vol.13 , Issue.6 , pp. 2263-2270
    • Roscoe, N.M.1    Judd, M.D.2
  • 24
    • 84937118726 scopus 로고    scopus 로고
    • Introduction to magnetism and magnetics materials
    • 2nd ed. Ames, IA, USA: Chapman & Hall
    • D. Jiles, "Introduction to magnetism and magnetics materials," in Magnetism, 2nd ed. Ames, IA, USA: Chapman & Hall, 1998, pp. 49-51.
    • (1998) Magnetism , pp. 49-51
    • Jiles, D.1
  • 25
    • 78650885060 scopus 로고    scopus 로고
    • Calculation of the connected magnetic and electric fields around an overhead-line tower for an estimation of their influence on maintenance personnel
    • Jan.
    • B. Zemljaric, "Calculation of the connected magnetic and electric fields around an overhead-line tower for an estimation of their influence on maintenance personnel," IEEE Trans. Power Del., vol. 26, no. 1, pp. 467-474, Jan. 2011.
    • (2011) IEEE Trans. Power Del. , vol.26 , Issue.1 , pp. 467-474
    • Zemljaric, B.1
  • 27
    • 0030189083 scopus 로고    scopus 로고
    • Mitigation of magnetic field near power lines
    • Jul.
    • A. R. Memari and W. Janischewskyj, "Mitigation of magnetic field near power lines," IEEE Trans. Power Del., vol. 11, no. 3, pp. 1577-1586, Jul. 1996.
    • (1996) IEEE Trans. Power Del. , vol.11 , Issue.3 , pp. 1577-1586
    • Memari, A.R.1    Janischewskyj, W.2
  • 28
    • 0026912425 scopus 로고
    • Overhead line design in relation to electric and magnetic field limits
    • B. J. Maddock, "Overhead line design in relation to electric and magnetic field limits," Power Eng. J., vol. 6, no. 5, pp. 217-224, 1992.
    • (1992) Power Eng. J. , vol.6 , Issue.5 , pp. 217-224
    • Maddock, B.J.1
  • 30
    • 84864862509 scopus 로고    scopus 로고
    • Effect of humidity on transmission lines' power frequency electric field measurements
    • W. He, B. Wan, C. Pei, J. Zhang, and J. He, "Effect of humidity on transmission lines' power frequency electric field measurements," in Proc. Asia-Pacific Symp. Electromagn. Compat., 2012, pp. 289-292.
    • (2012) Proc. Asia-Pacific Symp. Electromagn. Compat. , pp. 289-292
    • He, W.1    Wan, B.2    Pei, C.3    Zhang, J.4    He, J.5
  • 31
    • 70350287461 scopus 로고    scopus 로고
    • Magnetic-field calculation under EHV transmission lines for more realistic cases
    • Oct.
    • A. Dein, "Magnetic-field calculation under EHV transmission lines for more realistic cases," IEEE Trans. Power Del., vol. 24, no. 4, pp. 2214-2222, Oct. 2009.
    • (2009) IEEE Trans. Power Del. , vol.24 , Issue.4 , pp. 2214-2222
    • Dein, A.1
  • 32
    • 67649230286 scopus 로고    scopus 로고
    • Electric field analytical formulas for single-circuit power lines with a horizontal arrangement of conductors
    • A. E. Tzinevrakis, D. K. Tsanakas, and E. I. Mimos, "Electric field analytical formulas for single-circuit power lines with a horizontal arrangement of conductors," IET Gener., Transmiss. Distrib., vol. 3, no. 6, pp. 509-520, 2009.
    • (2009) IET Gener., Transmiss. Distrib. , vol.3 , Issue.6 , pp. 509-520
    • Tzinevrakis, A.E.1    Tsanakas, D.K.2    Mimos, E.I.3
  • 33
    • 47149113605 scopus 로고    scopus 로고
    • Analytical calculation of the electric field produced by single-circuit power lines
    • Jul.
    • A. E. Tzinevrakis, D. K. Tsanakas, and E. I. Mimos, "Analytical calculation of the electric field produced by single-circuit power lines," IEEE Trans. Power Del., vol. 23, no. 3, pp. 1495-1505, Jul. 2008.
    • (2008) IEEE Trans. Power Del. , vol.23 , Issue.3 , pp. 1495-1505
    • Tzinevrakis, A.E.1    Tsanakas, D.K.2    Mimos, E.I.3
  • 35
    • 84937108069 scopus 로고    scopus 로고
    • [Online]. Available
    • Ferroxcube soft Mn-Zn ferrite cores, datasheet. (2015). [Online]. Available: http://www.ferroxcube.com/FerroxcubeCorporateReception/datasheet/sfemisup.pdf
    • (2015) Ferroxcube Soft Mn-Zn Ferrite Cores, Datasheet
  • 38
    • 84877277130 scopus 로고    scopus 로고
    • [Online]. Available
    • MICAz wireless sensor, (MPR2400) 2.4 GHz Mote. (2013). [Online]. Available: http://www.memsic.com/products/wireless-sensor-networks/wirelessmodules.html
    • (2013) MICAz Wireless Sensor, (MPR2400) 2.4 GHz Mote
  • 39
    • 84937147653 scopus 로고    scopus 로고
    • [Online].Available
    • Invisible-systems, GatewayGPRS,GPS&RF. (2015). [Online].Available: http://www.invisible-systems.com/solutions/pdf/Gateway%20GPRS% 20GPS%20RF.pdf
    • (2015) Invisible-systems, GatewayGPRS,GPS&RF
  • 40
    • 84894452636 scopus 로고    scopus 로고
    • Development and experimental validation of a weather-based dynamic line rating system
    • D. J. Spoor and J. P. Roberts, "Development and experimental validation of a weather-based dynamic line rating system," in Proc. IEEE PES Innovative Smart Grid Technol. Asia, 2011, pp. 1-7.
    • (2011) Proc. IEEE PES Innovative Smart Grid Technol. Asia , pp. 1-7
    • Spoor, D.J.1    Roberts, J.P.2
  • 41
    • 84859764226 scopus 로고    scopus 로고
    • Identification of critical spans for monitoring systems in dynamic thermal rating
    • Apr.
    • M. Matus, D. Saez, and M. Favley, "Identification of critical spans for monitoring systems in dynamic thermal rating," IEEE Trans. Power Del., vol. 27, no. 2, pp. 1002-1009, Apr. 2012.
    • (2012) IEEE Trans. Power Del. , vol.27 , Issue.2 , pp. 1002-1009
    • Matus, M.1    Saez, D.2    Favley, M.3