메뉴 건너뛰기




Volumn 574, Issue , 2006, Pages 57-73

Electrodes and multiple electrode systems for radio frequency ablation: A proposal for updated terminology

Author keywords

Kidney; Liver; Radio frequency ablation; Soft tissues

Indexed keywords


EID: 84934441667     PISSN: 00652598     EISSN: None     Source Type: Book Series    
DOI: 10.1007/0-387-29512-7_8     Document Type: Conference Paper
Times cited : (13)

References (60)
  • 2
    • 85069137296 scopus 로고    scopus 로고
    • accessed February 4th, 2004
    • http://www.radionics.com/default-ab.shtml, accessed February 4th, 2004
  • 3
    • 85069134466 scopus 로고    scopus 로고
    • accessed February 4th, 2004
    • http://www.ritamedical.com/, accessed February 4th, 2004.
  • 4
    • 85069135247 scopus 로고    scopus 로고
    • accessed February 4th, 2004
    • http://www.bostonscientific.com/, accessed February 4th, 2004.
  • 5
    • 85069142888 scopus 로고    scopus 로고
    • accessed February 4th, 2004
    • http://www.berchtold.de/2/main2.htm, accessed February 4th, 2004.
  • 6
    • 85069130274 scopus 로고    scopus 로고
    • accessed February 4th, 2004
    • http://www.invatec.it/1024/index1024.htm, accessed February 4th, 2004.
  • 7
    • 85069134398 scopus 로고    scopus 로고
    • http://www.celon.com/htdocs/1tech/efset1.htm, accessed June 30th 2004-07-27.
    • http://www.celon.com/htdocs/1tech/efset1.htm, accessed June 30th 2004-07-27.
  • 11
    • 0030210698 scopus 로고    scopus 로고
    • Radiofrequency tissue ablation: Increased lesion diameter with a perfusion electrode
    • Goldberg SN, Gazelle GS, Solbiati L, Rittman WJ, Mueller PR. Radiofrequency tissue ablation: increased lesion diameter with a perfusion electrode. Acad Radiol. 1996;3:636-644.
    • (1996) Acad Radiol , vol.3 , pp. 636-644
    • Goldberg, S.N.1    Gazelle, G.S.2    Solbiati, L.3    Rittman, W.J.4    Mueller, P.R.5
  • 13
    • 0030187101 scopus 로고    scopus 로고
    • A cooled needle electrode for radiofrequency tissue ablation: Thermodynamic aspects of improved performance compared with conventional needle design
    • Lorentzen T. A cooled needle electrode for radiofrequency tissue ablation: thermodynamic aspects of improved performance compared with conventional needle design. Acad Radiol. 1996;3:556-563.
    • (1996) Acad Radiol , vol.3 , pp. 556-563
    • Lorentzen, T.1
  • 16
    • 0000097040 scopus 로고    scopus 로고
    • Large-volume tissue ablation with radio frequency by using a clustered, internally cooled electrode technique: Laboratory and clinical experience in liver metastases
    • Goldberg SN, Solbiati L, Hahn PF, Cosman E, Conrad JE, Fogle R, Gazelle GS. Large-volume tissue ablation with radio frequency by using a clustered, internally cooled electrode technique: laboratory and clinical experience in liver metastases. Radiology. 1998;209:371-379.
    • (1998) Radiology , vol.209 , pp. 371-379
    • Goldberg, S.N.1    Solbiati, L.2    Hahn, P.F.3    Cosman, E.4    Conrad, J.E.5    Fogle, R.6    Gazelle, G.S.7
  • 17
    • 12644299317 scopus 로고    scopus 로고
    • Large volume porcine liver ablation with the use of a percutaneous expandable electrosurgical probe
    • Le Veen RF, Fox RL, Schneider PD, Hinrichs S. Large volume porcine liver ablation with the use of a percutaneous expandable electrosurgical probe. JVIR 7 2003;(1, part 2):217-218.
    • (2003) JVIR , vol.7 , Issue.1 and PART 2 , pp. 217-218
    • Le Veen, R.F.1    Fox, R.L.2    Schneider, P.D.3    Hinrichs, S.4
  • 19
    • 0000845462 scopus 로고
    • Intramural ablation using radiofrequency energy via screw-tip catheter and saline electrode
    • Hoey MF, Mulier PM, Shake JG. Intramural ablation using radiofrequency energy via screw-tip catheter and saline electrode. PACE. 1995;18 (II):917.
    • (1995) PACE , vol.18 , Issue.II , pp. 917
    • Hoey, M.F.1    Mulier, P.M.2    Shake, J.G.3
  • 21
    • 0242298719 scopus 로고    scopus 로고
    • Radiofrequency interstitial tissue ablation: Wet electrode
    • Leveillee RJ, Hoey MF. Radiofrequency interstitial tissue ablation: wet electrode. J Endourol. 2003;17:563-577.
    • (2003) J Endourol , vol.17 , pp. 563-577
    • Leveillee, R.J.1    Hoey, M.F.2
  • 22
    • 0000192158 scopus 로고    scopus 로고
    • MR guided interstitial bipolar RF thermometry (RFITT): In vitro evaluations and first clinical results
    • Mack M, Straub R, Desinger K, Balzer JO, Zangos S, Vogl TJ. MR guided interstitial bipolar RF thermometry (RFITT): in vitro evaluations and first clinical results. Radiology. 2000;217 (suppl):539.
    • (2000) Radiology , vol.217 , Issue.SUPPL. , pp. 539
    • Mack, M.1    Straub, R.2    Desinger, K.3    Balzer, J.O.4    Zangos, S.5    Vogl, T.J.6
  • 23
    • 17144425603 scopus 로고    scopus 로고
    • MR-guided bipolar RF-thermotherapy (RFITT): In vitro evaluations and first clinical results
    • Mack MG, Desinger K, Straub R, Stein T, Balzer JO, Vogl TJ. MR-guided bipolar RF-thermotherapy (RFITT): in vitro evaluations and first clinical results. Eur Radiol. 2002;12 (suppl 1):141.
    • (2002) Eur Radiol , vol.12 , Issue.SUPPL. 1 , pp. 141
    • Mack, M.G.1    Desinger, K.2    Straub, R.3    Stein, T.4    Balzer, J.O.5    Vogl, T.J.6
  • 24
    • 85069144252 scopus 로고    scopus 로고
    • Cooled-wet electrode
    • US patent no 6514251 B1, Feb 4, 2003. Priority date: August 14, 1998
    • Ni Y, Miao Y, Marchal G. Cooled-wet electrode. US patent no 6514251 B1, Feb 4, 2003. Priority date: August 14, 1998
    • Ni, Y.1    Miao, Y.2    Marchal, G.3
  • 25
    • 0033938088 scopus 로고    scopus 로고
    • A comparative study on validation of a novel cooled-wet electrode for radiofrequency ablation
    • Miao Y, Ni Y, Yu J, Marchal G. A comparative study on validation of a novel cooled-wet electrode for radiofrequency ablation. Invest Radiol. 2000;35:438-444.
    • (2000) Invest Radiol , vol.35 , pp. 438-444
    • Miao, Y.1    Ni, Y.2    Yu, J.3    Marchal, G.4
  • 26
    • 0000374601 scopus 로고    scopus 로고
    • Optimization of radiofrequency ablation by using an 'expandable-wet' electrode: Results of ex vivo experiment
    • Miao Y, Ni Y, Yu J, Marchal GJ. Optimization of radiofrequency ablation by using an 'expandable-wet' electrode: results of ex vivo experiment. Radiology. 1999;213:102.
    • (1999) Radiology , vol.213 , pp. 102
    • Miao, Y.1    Ni, Y.2    Yu, J.3    Marchal, G.J.4
  • 27
    • 0034838929 scopus 로고    scopus 로고
    • An ex vivo study on radiofrequency tissue ablation: Increased lesion size by using an "expandable-wet" electrode
    • Miao Y, Ni Y, Yu J, Zhang H, Baert A, Marchal G. An ex vivo study on radiofrequency tissue ablation: increased lesion size by using an "expandable-wet" electrode. Eur Radiol. 2001;11:1841-1847.
    • (2001) Eur Radiol , vol.11 , pp. 1841-1847
    • Miao, Y.1    Ni, Y.2    Yu, J.3    Zhang, H.4    Baert, A.5    Marchal, G.6
  • 28
    • 85069135780 scopus 로고    scopus 로고
    • Method and apparatus for creating a bi-polar virtual electrode used for the ablation of tissue
    • US Patent no 6238393 B1, May 29, 2001. Priority date July 6, 1999
    • Mulier P, Hoey M. Method and apparatus for creating a bi-polar virtual electrode used for the ablation of tissue. US Patent no 6238393 B1, May 29, 2001. Priority date July 6, 1999.
    • Mulier, P.1    Hoey, M.2
  • 30
    • 3242708018 scopus 로고    scopus 로고
    • Saline-enhanced hepatic radiofrequency ablation using a perfused-cooled electrode: Comparison of dual probe bipolar mode with monopolar and single probe bipolar modes
    • Lee JM, Han JK, Kim SH, Lee JY, Kim DJ, Lee MW, Cho GG, Han CJ, Choi BI. Saline-enhanced hepatic radiofrequency ablation using a perfused-cooled electrode: comparison of dual probe bipolar mode with monopolar and single probe bipolar modes. Korean J Radiol. 2004;5:121-127.
    • (2004) Korean J Radiol , vol.5 , pp. 121-127
    • Lee, J.M.1    Han, J.K.2    Kim, S.H.3    Lee, J.Y.4    Kim, D.J.5    Lee, M.W.6    Cho, G.G.7    Han, C.J.8    Choi, B.I.9
  • 31
    • 17144363448 scopus 로고    scopus 로고
    • Hepatic radiofrequency ablation with multiple active electrodes is superior to conventional overlapping technique in an ex vivo model
    • Wright AS, Haemmerich DG, Chachati L, Webster JG, Mahvi DM, Lee FT. Hepatic radiofrequency ablation with multiple active electrodes is superior to conventional overlapping technique in an ex vivo model. Radiology. 2002;225 (suppl):639.
    • (2002) Radiology , vol.225 , Issue.SUPPL. , pp. 639
    • Wright, A.S.1    Haemmerich, D.G.2    Chachati, L.3    Webster, J.G.4    Mahvi, D.M.5    Lee, F.T.6
  • 32
    • 17144413659 scopus 로고
    • Radiofrequency tissue ablation using multiprobe arrays: Greater tissue destruction than multiple probes operating alone
    • Goldberg SN, Gazelle GS, Dawson SL, Rittman WJ, Mueller PR, Rosenthal DI. Radiofrequency tissue ablation using multiprobe arrays: greater tissue destruction than multiple probes operating alone Radiology. 1994;193:S281.
    • (1994) Radiology , vol.193
    • Goldberg, S.N.1    Gazelle, G.S.2    Dawson, S.L.3    Rittman, W.J.4    Mueller, P.R.5    Rosenthal, D.I.6
  • 33
    • 17144390609 scopus 로고    scopus 로고
    • Optimisation of treatment strategy using cooled-tip radiofrequency electrodes in ex vivo liver
    • Gillams AR, Lees WR. Optimisation of treatment strategy using cooled-tip radiofrequency electrodes in ex vivo liver. European Radiol. 2001;11(suppl A):171.
    • (2001) European Radiol , vol.11 , Issue.SUPPL. A , pp. 171
    • Gillams, A.R.1    Lees, W.R.2
  • 34
    • 0942276404 scopus 로고    scopus 로고
    • Dual-probe radiofrequency ablation: An in vitro experimental study in bovine liver
    • Lee JM, Rhim H, Han JK, Youn BJ, Kim SH, Choi BI. Dual-probe radiofrequency ablation: an in vitro experimental study in bovine liver. Invest Radiol. 2004;39:89-96.
    • (2004) Invest Radiol , vol.39 , pp. 89-96
    • Lee, J.M.1    Rhim, H.2    Han, J.K.3    Youn, B.J.4    Kim, S.H.5    Choi, B.I.6
  • 35
    • 0036841471 scopus 로고    scopus 로고
    • Hepatocellular carcinoma: Percutaneous radiofrequency ablation using expandable needle electrodes and the double-insertion technique
    • Shirato K, Morimoto M, Tomita N, Kokawa A, Sugimori K, Saito T, Tanaka K. Hepatocellular carcinoma: percutaneous radiofrequency ablation using expandable needle electrodes and the double-insertion technique. Hepatogastroenterology. 2002;49:1481-1483.
    • (2002) Hepatogastroenterology , vol.49 , pp. 1481-1483
    • Shirato, K.1    Morimoto, M.2    Tomita, N.3    Kokawa, A.4    Sugimori, K.5    Saito, T.6    Tanaka, K.7
  • 36
    • 0008883267 scopus 로고
    • Percutaneous liver ablation using bipolar radiofrequency electrocautery
    • Jones CD, McGahan JP, Gu W, Brock JM. Percutaneous liver ablation using bipolar radiofrequency electrocautery. Radiology. 1995;197:140.
    • (1995) Radiology , vol.197 , pp. 140
    • Jones, C.D.1    McGahan, J.P.2    Gu, W.3    Brock, J.M.4
  • 37
    • 17144390954 scopus 로고    scopus 로고
    • Multi-bipolar electrode system
    • Patent application GB0318661A0, August 8
    • Mulier S, Ni Y, Mulier P, Marchal G, Michel L. Multi-bipolar electrode system. Patent application GB0318661A0, August 8, 2003.
    • (2003)
    • Mulier, S.1    Ni, Y.2    Mulier, P.3    Marchal, G.4    Michel, L.5
  • 38
    • 17144407843 scopus 로고    scopus 로고
    • Linear radiofrequency coagulation
    • Patent application GB0324458A0, October 21
    • Mulier S, Ni Y, Mulier P, Marchal G, Michel L. Linear radiofrequency coagulation. Patent application GB0324458A0, October 21, 2003.
    • (2003)
    • Mulier, S.1    Ni, Y.2    Mulier, P.3    Marchal, G.4    Michel, L.5
  • 40
    • 0142147989 scopus 로고    scopus 로고
    • Bipolar saline-enhanced electrode for radiofrequency ablation: Results of experimental study of in vivo porcine liver
    • Burdio F, Guemes A, Burdio JM, Navarro A, Sousa R, Castiella T, Cruz I, Burzaco O, Lozano R. Bipolar saline-enhanced electrode for radiofrequency ablation: results of experimental study of in vivo porcine liver. Radiology. 2003;229:447-456.
    • (2003) Radiology , vol.229 , pp. 447-456
    • Burdio, F.1    Guemes, A.2    Burdio, J.M.3    Navarro, A.4    Sousa, R.5    Castiella, T.6    Cruz, I.7    Burzaco, O.8    Lozano, R.9
  • 42
    • 3042834419 scopus 로고    scopus 로고
    • Novel in-line multielectrode radiofrequency ablation considerably reduces blood loss during liver resection in an animal model
    • Gananadha S, Morris DL. Novel in-line multielectrode radiofrequency ablation considerably reduces blood loss during liver resection in an animal model. ANZ J Surg. 2004;74:482-485.
    • (2004) ANZ J Surg , vol.74 , pp. 482-485
    • Gananadha, S.1    Morris, D.L.2
  • 44
    • 17144365299 scopus 로고    scopus 로고
    • Bipolar radiofrequency ablation in ex vivo bovine liver with the open-perfused system versus the cooled-wet system
    • Jun;
    • Lee JM, Han JK, Kim SH, Sohn KL, Choi SH, Choi BI. Bipolar radiofrequency ablation in ex vivo bovine liver with the open-perfused system versus the cooled-wet system. Eur J Radiol. 2005 Jun;54(3):408-417.
    • (2005) Eur J Radiol , vol.54 , Issue.3 , pp. 408-417
    • Lee, J.M.1    Han, J.K.2    Kim, S.H.3    Sohn, K.L.4    Choi, S.H.5    Choi, B.I.6
  • 45
    • 0346097997 scopus 로고    scopus 로고
    • Ultrasound-guided percutaneous thermal ablation of hepatocellular carcinoma using microwave and radiofrequency ablation
    • Xu H, Xie X, Lu M, Chen J, Yin X, Xu Z, Liu G. Ultrasound-guided percutaneous thermal ablation of hepatocellular carcinoma using microwave and radiofrequency ablation. Clin Radiol. 2004;59:53-61.
    • (2004) Clin Radiol , vol.59 , pp. 53-61
    • Xu, H.1    Xie, X.2    Lu, M.3    Chen, J.4    Yin, X.5    Xu, Z.6    Liu, G.7
  • 47
    • 0347479222 scopus 로고    scopus 로고
    • Radiofrequency ablation: Modeling the enhanced temperature response to adjuvant NaCl pretreatment
    • Lobo SM, Afzal KS, Ahmed M, Kruskal JB, Lenkinski RE, Goldberg SN. Radiofrequency ablation: modeling the enhanced temperature response to adjuvant NaCl pretreatment. Radiology. 2004;230:175-182.
    • (2004) Radiology , vol.230 , pp. 175-182
    • Lobo, S.M.1    Afzal, K.S.2    Ahmed, M.3    Kruskal, J.B.4    Lenkinski, R.E.5    Goldberg, S.N.6
  • 49
    • 0346272723 scopus 로고    scopus 로고
    • Combined radiofrequency ablation and hot saline injection in rabbit liver
    • Kim YK, Lee JM, Kim SW, Kim CS. Combined radiofrequency ablation and hot saline injection in rabbit liver. Invest Radiol. 2003;38:725-732.
    • (2003) Invest Radiol , vol.38 , pp. 725-732
    • Kim, Y.K.1    Lee, J.M.2    Kim, S.W.3    Kim, C.S.4
  • 50
    • 0038499608 scopus 로고    scopus 로고
    • Percutaneous radiofrequency thermal ablation with hypertonic saline injection: In vivo study in a rabbit liver model
    • Lee JM, Kim YK, Lee YH, Kim SW, Li CA, Kim CS. Percutaneous radiofrequency thermal ablation with hypertonic saline injection: in vivo study in a rabbit liver model. Korean J Radiol. 2003;4:27-34.
    • (2003) Korean J Radiol , vol.4 , pp. 27-34
    • Lee, J.M.1    Kim, Y.K.2    Lee, Y.H.3    Kim, S.W.4    Li, C.A.5    Kim, C.S.6
  • 51
    • 0344286771 scopus 로고    scopus 로고
    • Radiofrequency thermal ablation: Increased treatment effect with saline pre-treatment
    • Solbiati L, Goldberg SN, Livraghi T, Meloni F, Ierace T, Cova L. Radiofrequency thermal ablation: increased treatment effect with saline pre-treatment. Radiology. 2000;217(suppl):607.
    • (2000) Radiology , vol.217 , Issue.SUPPL. , pp. 607
    • Solbiati, L.1    Goldberg, S.N.2    Livraghi, T.3    Meloni, F.4    Ierace, T.5    Cova, L.6
  • 52
    • 1642322111 scopus 로고    scopus 로고
    • Minimizing complications with radiofrequency ablation for liver cancer: The importance of properly controlled clinical trials and standardized reporting
    • Helton WS. Minimizing complications with radiofrequency ablation for liver cancer: the importance of properly controlled clinical trials and standardized reporting. Ann Surg. 2004;239:459-463.
    • (2004) Ann Surg , vol.239 , pp. 459-463
    • Helton, W.S.1
  • 53
    • 0842302447 scopus 로고    scopus 로고
    • Radiofrequency thermal ablation with expandable needle of focal liver malignancies: Complication report
    • Buscarini E, Buscarini L. Radiofrequency thermal ablation with expandable needle of focal liver malignancies: complication report. Eur Radiol. 2004;14:31-37.
    • (2004) Eur Radiol , vol.14 , pp. 31-37
    • Buscarini, E.1    Buscarini, L.2
  • 54
    • 11844255315 scopus 로고    scopus 로고
    • Society of Interventional Radiology Standards of Practice Committee. Quality improvement guidelines for the reporting and archiving of interventional radiology procedures
    • Omary RA, Bettmann MA, Cardella JF, Bakal CW, Schwartzberg MS, Sacks D, Rholl KS, Meranze SG, Lewis CA; Society of Interventional Radiology Standards of Practice Committee. Quality improvement guidelines for the reporting and archiving of interventional radiology procedures. J Vasc Interv Radiol. 2003;14(9 Pt 2):S293-S295.
    • (2003) J Vasc Interv Radiol , vol.14 , Issue.9 PART 2
    • Omary, R.A.1    Bettmann, M.A.2    Cardella, J.F.3    Bakal, C.W.4    Schwartzberg, M.S.5    Sacks, D.6    Rholl, K.S.7    Meranze, S.G.8    Lewis, C.A.9
  • 55
    • 2442528430 scopus 로고    scopus 로고
    • Percutaneous radiofrequence-ablation of liver cell carcinoma: A current overview
    • Kettenbach J, Blum M, Kilanowicz E, Schwaighofer SM, Lammer J. Percutaneous radiofrequence-ablation of liver cell carcinoma: a current overview. Radiologe. 2004;44:330-338.
    • (2004) Radiologe , vol.44 , pp. 330-338
    • Kettenbach, J.1    Blum, M.2    Kilanowicz, E.3    Schwaighofer, S.M.4    Lammer, J.5
  • 56
    • 0042369008 scopus 로고    scopus 로고
    • Radiofrequenzablation ex vivo: Vergleich der Effektivität von impedance control mode versus manual control mode unter Verwendung einer geschlossen perfundierten Cluster-Ablationssonde.
    • Schmidt D, Trubenbach J, Konig CW, Brieger J, Duda S, Claussen CD, Pereira PL. Radiofrequenzablation ex vivo: Vergleich der Effektivität von impedance control mode versus manual control mode unter Verwendung einer geschlossen perfundierten Cluster-Ablationssonde. Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr. 2003;175:967-972.
    • (2003) Rofo Fortschr Geb Rontgenstr Neuen Bildgeb Verfahr , vol.175 , pp. 967-972
    • Schmidt, D.1    Trubenbach, J.2    Konig, C.W.3    Brieger, J.4    Duda, S.5    Claussen, C.D.6    Pereira, P.L.7
  • 57
  • 58
  • 60
    • 17044364291 scopus 로고    scopus 로고
    • Interest of radiofrequency liver tissue ablation with a bipolar-wet electrode
    • Gangi A, Guth S, Imbert J. Interest of radiofrequency liver tissue ablation with a bipolar-wet electrode. Eur Radiol. 2003;13(suppl 1):477.
    • (2003) Eur Radiol , vol.13 , Issue.SUPPL. 1 , pp. 477
    • Gangi, A.1    Guth, S.2    Imbert, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.