메뉴 건너뛰기




Volumn 244, Issue , 2015, Pages 85-93

First-in-man demonstration of a fully implanted myoelectric sensors system to control an advanced electromechanical prosthetic hand

Author keywords

IMES ; Implantable devices; Implantable electrodes; Myoelectric; Prosthesis

Indexed keywords

CASE REPORT; CLINICAL TRIAL; DEVICES; DISABLED PERSON; ELECTRODE; ELECTROMYOGRAPHY; HAND; HUMAN; LIMB PROSTHESIS; MALE; PHYSIOLOGY; PROCEDURES; PROSTHESIS DESIGN; PROSTHESIS IMPLANTATION; REHABILITATION; SKELETAL MUSCLE;

EID: 84933504838     PISSN: 01650270     EISSN: 1872678X     Source Type: Journal    
DOI: 10.1016/j.jneumeth.2014.07.016     Document Type: Article
Times cited : (156)

References (18)
  • 2
    • 0030554768 scopus 로고    scopus 로고
    • Epidemiologic over-view of individuals with upper-limb loss and their reported research priorities
    • Atkins D., Heard D., Donovan W. Epidemiologic over-view of individuals with upper-limb loss and their reported research priorities. J Prosthet Orthot 1996, 8(1):2-11. http://www.oandp.org/jpo/library/1996_01_002.asp.
    • (1996) J Prosthet Orthot , vol.8 , Issue.1 , pp. 2-11
    • Atkins, D.1    Heard, D.2    Donovan, W.3
  • 3
    • 35848949332 scopus 로고    scopus 로고
    • Upper limb prosthesis use and abandonment: a survey of the last 25 years
    • PMID: 17979010
    • Biddis E.A., Chau T.T. Upper limb prosthesis use and abandonment: a survey of the last 25 years. Prosthet Orthot Int 2007, 31(3):236-257. PMID: 17979010.
    • (2007) Prosthet Orthot Int , vol.31 , Issue.3 , pp. 236-257
    • Biddis, E.A.1    Chau, T.T.2
  • 4
    • 84939928161 scopus 로고    scopus 로고
    • [01.07.14]
    • Complete Control Coapt 2014, January 1, Retrieved from: http://coaptengineering.com/complete-control.html [01.07.14].
    • (2014) Coapt
  • 5
    • 63249112803 scopus 로고    scopus 로고
    • Review of secondary physical conditions associated with lower-limb amputation and long-term prosthesis use
    • Gailey R., Allen K., Castles J., Kucharik J., Roeder M. Review of secondary physical conditions associated with lower-limb amputation and long-term prosthesis use. J Rehabil Res Dev 2008, 45(January (1)). ISSN: 0748-7711.
    • (2008) J Rehabil Res Dev , vol.45 , Issue.1 JANUARY
    • Gailey, R.1    Allen, K.2    Castles, J.3    Kucharik, J.4    Roeder, M.5
  • 6
    • 0032950526 scopus 로고    scopus 로고
    • Save that arm: a study of problems in the remaining arm of unilateral upper limb amputees
    • PMID: 10355644
    • Jones L.E., Davidson J.H. Save that arm: a study of problems in the remaining arm of unilateral upper limb amputees. Prosthet Orthot Int 1999, 23(1):55-58. PMID: 10355644.
    • (1999) Prosthet Orthot Int , vol.23 , Issue.1 , pp. 55-58
    • Jones, L.E.1    Davidson, J.H.2
  • 7
    • 12144251339 scopus 로고    scopus 로고
    • The use of targeted muscle reinnervation for improved myoelectric prosthesis control in a bilateral shoulder disarticulation amputee
    • Kuiken T.A., Dumanian G.A., Lipschutz R.D., Miller L.A., Stubblefield K.A. The use of targeted muscle reinnervation for improved myoelectric prosthesis control in a bilateral shoulder disarticulation amputee. Prosthet Orthot Int 2004, 28(3):245-253.
    • (2004) Prosthet Orthot Int , vol.28 , Issue.3 , pp. 245-253
    • Kuiken, T.A.1    Dumanian, G.A.2    Lipschutz, R.D.3    Miller, L.A.4    Stubblefield, K.A.5
  • 8
    • 60249084509 scopus 로고    scopus 로고
    • Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms
    • PMID: 19211469
    • Kuiken T.A., Li G., Lock B.A., Lipschutz R.D., Miller L.A., Stubblefield K.A., et al. Targeted muscle reinnervation for real-time myoelectric control of multifunction artificial arms. JAMA 2009, 301(6):619-628. PMID: 19211469.
    • (2009) JAMA , vol.301 , Issue.6 , pp. 619-628
    • Kuiken, T.A.1    Li, G.2    Lock, B.A.3    Lipschutz, R.D.4    Miller, L.A.5    Stubblefield, K.A.6
  • 9
    • 0036295774 scopus 로고    scopus 로고
    • Establishing a standardized clinical assessment tool of pathologic and prosthetic hand function: normative data, reliability, and validity
    • Light C.M., Chappell P.H., Kyberd P.J. Establishing a standardized clinical assessment tool of pathologic and prosthetic hand function: normative data, reliability, and validity. Arch Phys Med Rehabil 2002, 83(6):776-783.
    • (2002) Arch Phys Med Rehabil , vol.83 , Issue.6 , pp. 776-783
    • Light, C.M.1    Chappell, P.H.2    Kyberd, P.J.3
  • 10
    • 66349121104 scopus 로고    scopus 로고
    • Assessment of capacity for myoelectric control: evaluation of construct and rating scale
    • Lindner H.Y., Linacre J.M., Norling Hermansson L.M. Assessment of capacity for myoelectric control: evaluation of construct and rating scale. J Rehabil Med 2009, 41(6):467-474.
    • (2009) J Rehabil Med , vol.41 , Issue.6 , pp. 467-474
    • Lindner, H.Y.1    Linacre, J.M.2    Norling Hermansson, L.M.3
  • 11
    • 33749531207 scopus 로고    scopus 로고
    • Simulation of intramuscular EMG signals detected using implantable myoelectric sensors (IMES
    • Lowery M.M., Weir R.F., Kuiken T.A. Simulation of intramuscular EMG signals detected using implantable myoelectric sensors (IMES). IEEE Trans Biomed Eng 2006, 53(October (10)):1926-1933.
    • (2006) IEEE Trans Biomed Eng , vol.53 , Issue.10 OCTOBER , pp. 1926-1933
    • Lowery, M.M.1    Weir, R.F.2    Kuiken, T.A.3
  • 12
    • 77954353125 scopus 로고    scopus 로고
    • Unilateral upper-limb loss: satisfaction and prosthetic-device use in veterans and service members from Vietnam and OIF/OEF conflicts
    • PMID: 20803400
    • McFarland L.V., Winkler S.L.H., Heinemann A.W., Jones M., Esquenazi A. Unilateral upper-limb loss: satisfaction and prosthetic-device use in veterans and service members from Vietnam and OIF/OEF conflicts. JRRD 2010, 47(4):299-316. PMID: 20803400.
    • (2010) JRRD , vol.47 , Issue.4 , pp. 299-316
    • McFarland, L.V.1    Winkler, S.L.H.2    Heinemann, A.W.3    Jones, M.4    Esquenazi, A.5
  • 13
    • 78650104536 scopus 로고    scopus 로고
    • The early history of myoelectric control of prosthetic limbs (1945-1970
    • Springer, Berlin/Heidelberg, R.N. Scott (Ed.
    • McLean L. The early history of myoelectric control of prosthetic limbs (1945-1970). Powered upper limb prostheses 2004, 1-15. Springer, Berlin/Heidelberg. R.N. Scott (Ed.).
    • (2004) Powered upper limb prostheses , pp. 1-15
    • McLean, L.1
  • 14
    • 79960791840 scopus 로고    scopus 로고
    • Electromyogram pattern recognition for control of powered upper-limb prostheses: state of the art and challenges for clinical use
    • Scheme E., Englehart K. Electromyogram pattern recognition for control of powered upper-limb prostheses: state of the art and challenges for clinical use. JRRD 2011, 48(6):643-659.
    • (2011) JRRD , vol.48 , Issue.6 , pp. 643-659
    • Scheme, E.1    Englehart, K.2
  • 15
    • 78751605802 scopus 로고    scopus 로고
    • Neural interfaces for control of upper limb prostheses: the state of the art and future possibilities
    • Schultz A.E., Kuiken T.A. Neural interfaces for control of upper limb prostheses: the state of the art and future possibilities. PM R 2011, 3(1):55-67.
    • (2011) PM R , vol.3 , Issue.1 , pp. 55-67
    • Schultz, A.E.1    Kuiken, T.A.2
  • 17
    • 84880964031 scopus 로고    scopus 로고
    • Comparison of the power knee and C-leg during step-up and sit-to-stand tasks
    • Wolf E.J., Everding V.Q., Linberg A.A., Czerniecki J.M., Gambel J.M. Comparison of the power knee and C-leg during step-up and sit-to-stand tasks. Gait Posture 2013, 38(3):397-402.
    • (2013) Gait Posture , vol.38 , Issue.3 , pp. 397-402
    • Wolf, E.J.1    Everding, V.Q.2    Linberg, A.A.3    Czerniecki, J.M.4    Gambel, J.M.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.