메뉴 건너뛰기




Volumn 34, Issue 5, 2015, Pages 701-709

A multicenter analysis of clinical hemolysis in patients supported with durable, long-term left ventricular assist device therapy

Author keywords

Hemolysis; Outcomes; Survival; Thrombosis; Ventricular assist device

Indexed keywords

HEMOGLOBIN; INOTROPIC AGENT;

EID: 84933180313     PISSN: 10532498     EISSN: 15573117     Source Type: Journal    
DOI: 10.1016/j.healun.2014.10.002     Document Type: Article
Times cited : (56)

References (16)
  • 1
    • 70349191771 scopus 로고    scopus 로고
    • Incidence and patterns of adverse event onset during the first 60 days after ventricular assist device implantation
    • Genovese EA, Dew MA, Teuteberg JJ, et al. Incidence and patterns of adverse event onset during the first 60 days after ventricular assist device implantation. Ann Thorac Surg 2009;88:1162-70.
    • (2009) Ann Thorac Surg , vol.88 , pp. 1162-1170
    • Genovese, E.A.1    Dew, M.A.2    Teuteberg, J.J.3
  • 2
    • 2342664194 scopus 로고    scopus 로고
    • Pump-induced haemolysis: A comparison of short-term ventricular assist devices
    • Bennett M, Horton S, Thuys C, et al. Pump-induced haemolysis: a comparison of short-term ventricular assist devices. Perfusion 2004;19:107-11.
    • (2004) Perfusion , vol.19 , pp. 107-111
    • Bennett, M.1    Horton, S.2    Thuys, C.3
  • 3
    • 68749100663 scopus 로고    scopus 로고
    • Haemolysis in patients with ventricular assist devices: Major differences between systems
    • Heilmann C, Geisen U, Benk C, et al. Haemolysis in patients with ventricular assist devices: major differences between systems. Eur J Cardiothorac Surg 2009;36:580-4.
    • (2009) Eur J Cardiothorac Surg , vol.36 , pp. 580-584
    • Heilmann, C.1    Geisen, U.2    Benk, C.3
  • 4
    • 38349143974 scopus 로고    scopus 로고
    • Fibrinolytic activation during long-term support with the HeartMate II left ventricular assist device
    • Slaughter MS, Sobieski MA, Gallagher C, et al. Fibrinolytic activation during long-term support with the HeartMate II left ventricular assist device. ASAIO J 2008;54:115-9.
    • (2008) ASAIO J , vol.54 , pp. 115-119
    • Slaughter, M.S.1    Sobieski, M.A.2    Gallagher, C.3
  • 5
    • 84892148459 scopus 로고    scopus 로고
    • Unexpected abrupt increase in left ventricular assist device thrombosis
    • Starling RC, Moazami N, Silvestry SC, et al. Unexpected abrupt increase in left ventricular assist device thrombosis. N Engl J Med 2013;370:33-40.
    • (2013) N Engl J Med , vol.370 , pp. 33-40
    • Starling, R.C.1    Moazami, N.2    Silvestry, S.C.3
  • 6
    • 84892177900 scopus 로고    scopus 로고
    • Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device
    • Kirklin JK, Naftel DC, Kormos RL, et al. Interagency Registry for Mechanically Assisted Circulatory Support (INTERMACS) analysis of pump thrombosis in the HeartMate II left ventricular assist device. J Heart Lung Transplant 2014;33:12-22.
    • (2014) J Heart Lung Transplant , vol.33 , pp. 12-22
    • Kirklin, J.K.1    Naftel, D.C.2    Kormos, R.L.3
  • 7
    • 84892157543 scopus 로고    scopus 로고
    • Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: A multifactorial phenomenon
    • Uriel N, Han J, Morrison KA, et al. Device thrombosis in HeartMate II continuous-flow left ventricular assist devices: a multifactorial phenomenon. J Heart Lung Transplant 2013;33:51-9.
    • (2013) J Heart Lung Transplant , vol.33 , pp. 51-59
    • Uriel, N.1    Han, J.2    Morrison, K.A.3
  • 8
    • 84892178504 scopus 로고    scopus 로고
    • Diagnosis of hemolysis and device thrombosis with lactate dehydrogenase during left ventricular assist device support
    • Shah P, Mehta VM, Cowger JA, et al. Diagnosis of hemolysis and device thrombosis with lactate dehydrogenase during left ventricular assist device support. J Heart Lung Transplant 2013;33: 102-4.
    • (2013) J Heart Lung Transplant , vol.33 , pp. 102-104
    • Shah, P.1    Mehta, V.M.2    Cowger, J.A.3
  • 9
    • 0034282430 scopus 로고    scopus 로고
    • An investigation of blood flow behavior and hemolysis in artificial organs
    • Yasuda T, Shimokasa K, Funakubo A, et al. An investigation of blood flow behavior and hemolysis in artificial organs. ASAIO J 2000;46:527-31.
    • (2000) ASAIO J , vol.46 , pp. 527-531
    • Yasuda, T.1    Shimokasa, K.2    Funakubo, A.3
  • 10
    • 84892165254 scopus 로고    scopus 로고
    • A novel link between G6PD deficiency and hemolysis in patients with continuous-flow left ventricular assist devices
    • Alhosaini A, Jensen BC, Chang PP, et al. A novel link between G6PD deficiency and hemolysis in patients with continuous-flow left ventricular assist devices. J Heart Lung Transplant 2013;33:116-7.
    • (2013) J Heart Lung Transplant , vol.33 , pp. 116-117
    • Alhosaini, A.1    Jensen, B.C.2    Chang, P.P.3
  • 11
    • 73349129701 scopus 로고    scopus 로고
    • Advanced heart failure treated with continuous-flow left ventricular assist device
    • Slaughter MS, Rogers JG, Milano CA, et al. Advanced heart failure treated with continuous-flow left ventricular assist device. N Engl J Med 2009;361:2241-51.
    • (2009) N Engl J Med , vol.361 , pp. 2241-2251
    • Slaughter, M.S.1    Rogers, J.G.2    Milano, C.A.3
  • 12
    • 67650093608 scopus 로고    scopus 로고
    • Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device
    • Pagani FD, Miller LW, Russell SD, et al. Extended mechanical circulatory support with a continuous-flow rotary left ventricular assist device. J Am Coll Cardiol 2009;54:312-21.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 312-321
    • Pagani, F.D.1    Miller, L.W.2    Russell, S.D.3
  • 13
    • 33750926197 scopus 로고    scopus 로고
    • Extrinsic nonimmune hemolytic anemias
    • Hoffman R, Furie B, Benz Jr, EJ, McGlave P, Silberstein LE, Shattil SJ 6th ed. Philadelphia, PA: Saunders Elsevier chap 45
    • Price EA, Schrier SL. Extrinsic nonimmune hemolytic anemias. In: Hoffman R, Furie B, Benz Jr, EJ, McGlave P, Silberstein LE, Shattil SJ, editors. Hematology: basic principles and practice. 6th ed. Philadelphia, PA: Saunders Elsevier; 2012: chap 45.
    • (2012) Hematology: Basic Principles and Practice.
    • Price, E.A.1    Schrier, S.L.2
  • 14
    • 76449093221 scopus 로고    scopus 로고
    • Pleiotropic effects of intravascular haemolysis on vascular homeostasis
    • Kato GJ, Taylor JG. Pleiotropic effects of intravascular haemolysis on vascular homeostasis. Br J Haematol 2009;148:690-701.
    • (2009) Br J Haematol , vol.148 , pp. 690-701
    • Kato, G.J.1    Taylor, J.G.2
  • 15
    • 84872765576 scopus 로고    scopus 로고
    • Pump replacement for left ventricular assist device failure can be done safely and is associated with low mortality
    • Moazami N, Milano CA, John R, et al. Pump replacement for left ventricular assist device failure can be done safely and is associated with low mortality. Ann Thorac Surg 2013;95:500-5.
    • (2013) Ann Thorac Surg , vol.95 , pp. 500-505
    • Moazami, N.1    Milano, C.A.2    John, R.3
  • 16
    • 68949212915 scopus 로고    scopus 로고
    • Thresholds of physical activity and life expectancy for patients considering destination ventricular assist devices
    • Stewart GC, Brooks K, Pratibhu PP, et al. Thresholds of physical activity and life expectancy for patients considering destination ventricular assist devices. J Heart Lung Transplant 2009;28:863-9.
    • (2009) J Heart Lung Transplant , vol.28 , pp. 863-869
    • Stewart, G.C.1    Brooks, K.2    Pratibhu, P.P.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.