메뉴 건너뛰기




Volumn 157, Issue 7, 2015, Pages 1173-1178

Cortical bone trajectory and traditional trajectory—a radiological evaluation of screw-bone contact

Author keywords

Cortical bone trajectory; CT number; Hounsfield unit; Posterior lumbar spine fusion; Radiological study; Screw to bone contact

Indexed keywords

ADOLESCENT; ADULT; AGED; ARTICLE; BONE DENSITY; COMPUTER ASSISTED TOMOGRAPHY; CORTICAL BONE; CORTICAL BONE TRAJECTORY; DEGENERATIVE LUMBAR SPINE DISEASE; FEMALE; HUMAN; LUMBAR SPINE; LUMBAR VERTEBRA; MAJOR CLINICAL STUDY; MALE; PEDICLE SCREW; PRIORITY JOURNAL; RADIOSURGERY EQUIPMENT; SPINE DISEASE; TRADITIONAL TRAJECTORY; DEVICES; INTERVERTEBRAL DISC DEGENERATION; INTERVERTEBRAL DISC DISPLACEMENT; MIDDLE AGED; PROCEDURES; RADIOGRAPHY; SPINE FUSION; VERY ELDERLY; YOUNG ADULT;

EID: 84931568417     PISSN: 00016268     EISSN: 09420940     Source Type: Journal    
DOI: 10.1007/s00701-015-2432-6     Document Type: Article
Times cited : (48)

References (8)
  • 1
    • 84876415609 scopus 로고    scopus 로고
    • Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support
    • PID: 23104197
    • Perez-Orribo L, Kalb S, Reyes P, Chang S, Crawford N (2013) Biomechanics of lumbar cortical screw-rod fixation versus pedicle screw-rod fixation with and without interbody support. Spine 38:635–641
    • (2013) Spine , vol.38 , pp. 635-641
    • Perez-Orribo, L.1    Kalb, S.2    Reyes, P.3    Chang, S.4    Crawford, N.5
  • 3
    • 84905972263 scopus 로고    scopus 로고
    • Repeatable calibration of Hounsfield units to mineral density and effects of scanning medium
    • Crookshank M, Ploeg H, Ellis R, Maclntyre J (2014) Repeatable calibration of Hounsfield units to mineral density and effects of scanning medium. Adv Biomech Appl 1(1):15–22
    • (2014) Adv Biomech Appl , vol.1 , Issue.1 , pp. 15-22
    • Crookshank, M.1    Ploeg, H.2    Ellis, R.3    Maclntyre, J.4
  • 4
    • 0005012554 scopus 로고
    • Architecture interieure des vertebres (statique et physiologie de la colonne vertebrale)
    • Gallois M, Japiot (1925) Architecture interieure des vertebres (statique et physiologie de la colonne vertebrale). Rev Chir 63:687–708
    • (1925) Rev Chir , vol.63 , pp. 687-708
    • Gallois, M.1    Japiot2
  • 6
    • 0018439027 scopus 로고
    • Variations in the amount and distribution of cortical bone across the partes interarticulares of L5
    • COI: 1:STN:280:DyaL2s%2FntVWhtA%3D%3D, PID: 264031
    • Cyron BM, Hutton WC (1979) Variations in the amount and distribution of cortical bone across the partes interarticulares of L5. Spine 4(2):163–167
    • (1979) Spine , vol.4 , Issue.2 , pp. 163-167
    • Cyron, B.M.1    Hutton, W.C.2
  • 7
    • 0015712389 scopus 로고
    • The structure of the pars interarticularis of the lower lumbar vertebrae and its relation to the etiology of spondylolysis
    • Krenz J, Troup JD (1973) The structure of the pars interarticularis of the lower lumbar vertebrae and its relation to the etiology of spondylolysis. J Bone Joint Surg (Br) 55(4):735–741
    • (1973) J Bone Joint Surg (Br) , vol.55 , Issue.4 , pp. 735-741
    • Krenz, J.1    Troup, J.D.2
  • 8
    • 77955385364 scopus 로고    scopus 로고
    • The biomechanics of pedicle screw based instrumentation
    • COI: 1:STN:280:DC%2BC3cjhslaqtQ%3D%3D
    • Cho W, Cho W, Wu C (2010) The biomechanics of pedicle screw based instrumentation. J Bone Joint Surg 92(8):1061–1065
    • (2010) J Bone Joint Surg , vol.92 , Issue.8 , pp. 1061-1065
    • Cho, W.1    Cho, W.2    Wu, C.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.