메뉴 건너뛰기




Volumn 42, Issue 2, 2015, Pages 363-375

How to Approach Intrapartum Category II Tracings

Author keywords

Fetal heart rate monitoring; Neonatal encephalopathy; Patient safety

Indexed keywords

ALGORITHM; BODY POSITION; BRADYCARDIA; CLINICAL EVALUATION; FETAL WELL BEING; FETUS HEART RATE; FETUS MONITORING; HEART RATE VARIABILITY; HUMAN; LABOR; MATERNAL CARE; PRIORITY JOURNAL; REVIEW; STANDARDIZATION; TACHYCARDIA; UTERUS CONTRACTION; ADULT; DEVICES; FEMALE; NEWBORN; PH; PHYSIOLOGY; PRACTICE GUIDELINE; PREGNANCY; PROCEDURES;

EID: 84931394025     PISSN: 08898545     EISSN: 15580474     Source Type: Journal    
DOI: 10.1016/j.ogc.2015.01.013     Document Type: Review
Times cited : (9)

References (27)
  • 1
    • 55949106755 scopus 로고    scopus 로고
    • The 2008 National Institutes of Child Health and Human Development workshop report on electronic fetal monitoring; update on definitions, interpretation and research guidelines
    • Macones G.A., Hankins G.D., Spong C.Y., et al. The 2008 National Institutes of Child Health and Human Development workshop report on electronic fetal monitoring; update on definitions, interpretation and research guidelines. Obstet Gynecol 2008, 112:661-666.
    • (2008) Obstet Gynecol , vol.112 , pp. 661-666
    • Macones, G.A.1    Hankins, G.D.2    Spong, C.Y.3
  • 2
    • 78049525860 scopus 로고    scopus 로고
    • Practice Bulletin No. 116: Management of intrapartum fetal heart rate tracings
    • American College of Obstetricians and Gynecologists Practice Bulletin No. 116: Management of intrapartum fetal heart rate tracings. Obstet Gynecol 2010, 116:1232-1240.
    • (2010) Obstet Gynecol , vol.116 , pp. 1232-1240
    • American College of Obstetricians and, Gynecologists1
  • 3
    • 84855169310 scopus 로고    scopus 로고
    • Interobserver and intraobserver reliability of the NICHD 3-Tier Fetal Heart Rate Interpretation System
    • Blackwell S.C., Grobman W.A., Antoniewicz L., et al. Interobserver and intraobserver reliability of the NICHD 3-Tier Fetal Heart Rate Interpretation System. Am J Obstet Gynecol 2011, 205:378.e1-378.e5.
    • (2011) Am J Obstet Gynecol , vol.205 , pp. 378.e1-378.e5
    • Blackwell, S.C.1    Grobman, W.A.2    Antoniewicz, L.3
  • 4
    • 80053375326 scopus 로고    scopus 로고
    • Frequency of fetal heart rate categories and short-term neonatal outcome
    • Jackson M., Holmgren C., Esplin M.S., et al. Frequency of fetal heart rate categories and short-term neonatal outcome. Obstet Gynecol 2011, 118:803-808.
    • (2011) Obstet Gynecol , vol.118 , pp. 803-808
    • Jackson, M.1    Holmgren, C.2    Esplin, M.S.3
  • 5
    • 84880923360 scopus 로고    scopus 로고
    • Intrapartum management of category II fetal heart rate tracings: towards standardization of care
    • Clark S.L., Nageotte M.P., Garite T.J., et al. Intrapartum management of category II fetal heart rate tracings: towards standardization of care. Am J Obstet Gynecol 2013, 209(2):89-97.
    • (2013) Am J Obstet Gynecol , vol.209 , Issue.2 , pp. 89-97
    • Clark, S.L.1    Nageotte, M.P.2    Garite, T.J.3
  • 6
    • 34547093185 scopus 로고    scopus 로고
    • Prevention of birth asphyxia: responding appropriately to cardiotocograph (CTG) traces
    • Chandrahan E., Arulkumaran S. Prevention of birth asphyxia: responding appropriately to cardiotocograph (CTG) traces. Best Pract Res Clin Obstet Gynaecol 2007, 21:609-624.
    • (2007) Best Pract Res Clin Obstet Gynaecol , vol.21 , pp. 609-624
    • Chandrahan, E.1    Arulkumaran, S.2
  • 7
    • 34347267231 scopus 로고    scopus 로고
    • Aframework for standardized management of intrapartum fetal heart rate patterns
    • Parer J.T., Ikeda T. Aframework for standardized management of intrapartum fetal heart rate patterns. Am J Obstet Gynecol 2007, 197:26.e1-26.e6.
    • (2007) Am J Obstet Gynecol , vol.197 , pp. 26.e1-26.e6
    • Parer, J.T.1    Ikeda, T.2
  • 8
    • 84859429918 scopus 로고    scopus 로고
    • Electronic fetal heart rate monitoring: applying principles of patient safety
    • Miller D.A., Miller L.A. Electronic fetal heart rate monitoring: applying principles of patient safety. Am J Obstet Gynecol 2012, 206:278-283.
    • (2012) Am J Obstet Gynecol , vol.206 , pp. 278-283
    • Miller, D.A.1    Miller, L.A.2
  • 9
    • 0014150499 scopus 로고
    • The classification of fetal heart rate: II, a revised working classification
    • Hon E., Quilligan E.J. The classification of fetal heart rate: II, a revised working classification. Conn Med 1967, 31:779-784.
    • (1967) Conn Med , vol.31 , pp. 779-784
    • Hon, E.1    Quilligan, E.J.2
  • 10
    • 0026721155 scopus 로고
    • Randomised trial of cardiotocography alone or with ST waveform analysis for intrapartum monitoring
    • Westgate J.A., Harris M., Curnow J.S., et al. Randomised trial of cardiotocography alone or with ST waveform analysis for intrapartum monitoring. Lancet 1992, 340:194-198.
    • (1992) Lancet , vol.340 , pp. 194-198
    • Westgate, J.A.1    Harris, M.2    Curnow, J.S.3
  • 11
    • 0031031765 scopus 로고    scopus 로고
    • Brief repeated umbilical cord occlusions cause sustained cytotoxic cerebral edema and focal infarcts in near term fetal lambs
    • de Hann H.H., Gunn A.J., Williams C.E., et al. Brief repeated umbilical cord occlusions cause sustained cytotoxic cerebral edema and focal infarcts in near term fetal lambs. Pediatr Res 1997, 41:96-104.
    • (1997) Pediatr Res , vol.41 , pp. 96-104
    • de Hann, H.H.1    Gunn, A.J.2    Williams, C.E.3
  • 12
    • 0023600085 scopus 로고
    • Uterine artery blood velocities during contractions in pregnancy and labour related to intrauterine pressure
    • Janbu T., Nesheim B.I. Uterine artery blood velocities during contractions in pregnancy and labour related to intrauterine pressure. BJOG 1987, 94:1150-1155.
    • (1987) BJOG , vol.94 , pp. 1150-1155
    • Janbu, T.1    Nesheim, B.I.2
  • 13
    • 0031879051 scopus 로고    scopus 로고
    • Doppler ultrasound evaluation of ductus venosus blood flow during acute hypoxemia in fetal lambs
    • Tchirikov M., Eisermann K., Rybakowski C., et al. Doppler ultrasound evaluation of ductus venosus blood flow during acute hypoxemia in fetal lambs. Ultrasound Obstet Gynecol 1998, 11:426-431.
    • (1998) Ultrasound Obstet Gynecol , vol.11 , pp. 426-431
    • Tchirikov, M.1    Eisermann, K.2    Rybakowski, C.3
  • 14
    • 33845381208 scopus 로고    scopus 로고
    • Development of the ovine fetal cardiovascular defense to hypoxemia towards term
    • Fletcher A.J., Gardner D.S., Edwards M., et al. Development of the ovine fetal cardiovascular defense to hypoxemia towards term. Am J Physiol Heart Circ Physiol 2006, 291:H3023-H3034.
    • (2006) Am J Physiol Heart Circ Physiol , vol.291 , pp. H3023-H3034
    • Fletcher, A.J.1    Gardner, D.S.2    Edwards, M.3
  • 15
    • 0020523219 scopus 로고
    • Heart rate and blood pressure responses to umbilical cord compression in fetal lambs with special reference to the mechanism of variable deceleration
    • Itskovitz J., LaGamma E.F., Rudolph A.M. Heart rate and blood pressure responses to umbilical cord compression in fetal lambs with special reference to the mechanism of variable deceleration. Am J Obstet Gynecol 1983, 147:451-457.
    • (1983) Am J Obstet Gynecol , vol.147 , pp. 451-457
    • Itskovitz, J.1    LaGamma, E.F.2    Rudolph, A.M.3
  • 16
    • 0027818909 scopus 로고
    • Heart rate fall during acute hypoxemia: a measure of chemoreceptor response in fetal sheep
    • Baan J., Boekkooi P.F., Teitel D.F., et al. Heart rate fall during acute hypoxemia: a measure of chemoreceptor response in fetal sheep. JDev Physiol 1993, 19:105-111.
    • (1993) JDev Physiol , vol.19 , pp. 105-111
    • Baan, J.1    Boekkooi, P.F.2    Teitel, D.F.3
  • 17
    • 0030638412 scopus 로고    scopus 로고
    • Fetal heart rate changes do not reflect cardiovascular deterioration during brief repeated umbilical cord occlusions in near term fetal lambs
    • de Haan H.H., Gunn A.J., Gluckman P.D. Fetal heart rate changes do not reflect cardiovascular deterioration during brief repeated umbilical cord occlusions in near term fetal lambs. Am J Obstet Gynecol 1997, 176:8-17.
    • (1997) Am J Obstet Gynecol , vol.176 , pp. 8-17
    • de Haan, H.H.1    Gunn, A.J.2    Gluckman, P.D.3
  • 18
    • 0033011231 scopus 로고    scopus 로고
    • Fetal heart rate variability changes during brief repeated umbilical cord occlusion in near term fetal sheep
    • Westgate J.A., Bennet L., Gunn A.J. Fetal heart rate variability changes during brief repeated umbilical cord occlusion in near term fetal sheep. BJOG 1999, 106:664-671.
    • (1999) BJOG , vol.106 , pp. 664-671
    • Westgate, J.A.1    Bennet, L.2    Gunn, A.J.3
  • 19
    • 84931298764 scopus 로고    scopus 로고
    • New perspectives in electronic fetal surveillance
    • Hamilton E.F., Daly M.V., Townsend K. New perspectives in electronic fetal surveillance. JPerinat Med 2012, 0(0):1-10.
    • (2012) JPerinat Med , pp. 1-10
    • Hamilton, E.F.1    Daly, M.V.2    Townsend, K.3
  • 20
    • 33745061992 scopus 로고    scopus 로고
    • Fetal academia and electronic fetal heart rate patterns: is there evidence of an association?
    • Parer J.T., King T., Flanders S., et al. Fetal academia and electronic fetal heart rate patterns: is there evidence of an association?. JMatern Fetal Neonatal Med 2006, 19:289-294.
    • (2006) JMatern Fetal Neonatal Med , vol.19 , pp. 289-294
    • Parer, J.T.1    King, T.2    Flanders, S.3
  • 21
    • 19544366959 scopus 로고    scopus 로고
    • Efficacy of intrauterine resuscitation techniques in improving fetal oxygen status during labor
    • Simpson K.R., James D.C. Efficacy of intrauterine resuscitation techniques in improving fetal oxygen status during labor. Obstet Gynecol 2005, 105:1362-1368.
    • (2005) Obstet Gynecol , vol.105 , pp. 1362-1368
    • Simpson, K.R.1    James, D.C.2
  • 22
    • 33747892113 scopus 로고    scopus 로고
    • The effect of maternal oxygen administration on fetal pulse oximetry during labor in fetuses with non-reassuring fetal heart rate tracings
    • Hayden M., Gorenberg D., Nageotte M., et al. The effect of maternal oxygen administration on fetal pulse oximetry during labor in fetuses with non-reassuring fetal heart rate tracings. Am J Obstet Gynecol 2006, 195:735-738.
    • (2006) Am J Obstet Gynecol , vol.195 , pp. 735-738
    • Hayden, M.1    Gorenberg, D.2    Nageotte, M.3
  • 23
    • 34047148767 scopus 로고    scopus 로고
    • Effects of maternal oxygen administration on fetal pulse oximetry
    • Dildy G.A., Clark S.L. Effects of maternal oxygen administration on fetal pulse oximetry. Am J Obstet Gynecol 2007, 196:13-16.
    • (2007) Am J Obstet Gynecol , vol.196 , pp. 13-16
    • Dildy, G.A.1    Clark, S.L.2
  • 24
  • 25
    • 0027482951 scopus 로고
    • Uterine rupture after previous cesarean delivery: maternal and fetal consequences
    • Leung A.S., Leung E.K., Paul R.H. Uterine rupture after previous cesarean delivery: maternal and fetal consequences. Am J Obstet Gynecol 1993, 169:945-950.
    • (1993) Am J Obstet Gynecol , vol.169 , pp. 945-950
    • Leung, A.S.1    Leung, E.K.2    Paul, R.H.3
  • 26
    • 84921991413 scopus 로고    scopus 로고
    • Fetal pulse oximetry for fetal assessment in labour
    • CD004075
    • East C.E., Begg L., Colditz P.B., et al. Fetal pulse oximetry for fetal assessment in labour. Cochrane Database Syst Rev 2014, (10). CD004075.
    • (2014) Cochrane Database Syst Rev , Issue.10
    • East, C.E.1    Begg, L.2    Colditz, P.B.3
  • 27
    • 84930416935 scopus 로고    scopus 로고
    • Recognition and response to electronic fetal heart rate patterns - impact on newborn outcomes and primary cesarean delivery rate in women undergoing induction of labor
    • Clark S.L., Meyers J.A., Garthwaite T., et al. Recognition and response to electronic fetal heart rate patterns - impact on newborn outcomes and primary cesarean delivery rate in women undergoing induction of labor. Am J Obstet Gynecol 2014, 10.1016/j,ajog.2014.11.019.
    • (2014) Am J Obstet Gynecol
    • Clark, S.L.1    Meyers, J.A.2    Garthwaite, T.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.