메뉴 건너뛰기




Volumn 233, Issue , 2015, Pages 186-191

Repeatability of retinal macular thickness measurements in healthy subjects and diabetic patients with clinically significant macular edema: Evaluation of the follow-up system of spectralis optical coherence tomography

Author keywords

Diabetic macular edema; Optical coherence tomography; Spectralis

Indexed keywords

ADULT; ARTICLE; CONTROLLED STUDY; DIABETIC MACULAR EDEMA; EVALUATION STUDY; FEMALE; FOLLOW UP; HUMAN; MAJOR CLINICAL STUDY; MALE; MEASUREMENT REPEATABILITY; OPTICAL COHERENCE TOMOGRAPHY DEVICE; RETINA MACULA LUTEA; RETINAL THICKNESS; VISUAL ACUITY; ANATOMY AND HISTOLOGY; COMPARATIVE STUDY; COMPLICATION; DIABETIC RETINOPATHY; FOURIER ANALYSIS; LASER COAGULATION; MACULAR EDEMA; NON INSULIN DEPENDENT DIABETES MELLITUS; NORMAL HUMAN; OPTICAL COHERENCE TOMOGRAPHY; ORGAN SIZE; PATHOLOGY; PHYSIOLOGY; PROSPECTIVE STUDY; REPRODUCIBILITY; RETINA; STANDARDS;

EID: 84930927548     PISSN: 00303755     EISSN: 14230267     Source Type: Journal    
DOI: 10.1159/000380832     Document Type: Article
Times cited : (7)

References (21)
  • 1
    • 0346729846 scopus 로고    scopus 로고
    • Optical coherence tomography to detect and manage retinal disease and glaucoma
    • Jaffe GJ, Caprioli J: Optical coherence tomography to detect and manage retinal disease and glaucoma. Am J Ophthalmol 2004; 137: 156-169.
    • (2004) Am J Ophthalmol , vol.137 , pp. 156-169
    • Jaffe, G.J.1    Caprioli, J.2
  • 2
    • 0032997035 scopus 로고    scopus 로고
    • Patterns of diabetic macular edema with optical coherence tomography
    • Otani T, Kishi S, Maruyama Y: Patterns of diabetic macular edema with optical coherence tomography. Am J Ophthalmol 1999; 127: 688-693.
    • (1999) Am J Ophthalmol , vol.127 , pp. 688-693
    • Otani, T.1    Kishi, S.2    Maruyama, Y.3
  • 3
    • 7544228619 scopus 로고    scopus 로고
    • Diagnosis of macular pseudoholes and lamellar macular holes by optical coherence tomography
    • Haouchine B, Massin P, Tadayoni R, et al: Diagnosis of macular pseudoholes and lamellar macular holes by optical coherence tomography. Am J Ophthalmol 2004; 138: 732-739.
    • (2004) Am J Ophthalmol , vol.138 , pp. 732-739
    • Haouchine, B.1    Massin, P.2    Tadayoni, R.3
  • 4
    • 0036237712 scopus 로고    scopus 로고
    • Retinal thickness study with optical coherence tomography in patients with diabetes
    • Sanchez-Tocino H, Alvarez-Vidal A, Maldonado MJ, et al: Retinal thickness study with optical coherence tomography in patients with diabetes. Invest Ophthalmol Vis Sci 2002; 43: 1588-1594.
    • (2002) Invest Ophthalmol Vis Sci , vol.43 , pp. 1588-1594
    • Sanchez-Tocino, H.1    Alvarez-Vidal, A.2    Maldonado, M.J.3
  • 5
    • 33748617148 scopus 로고    scopus 로고
    • The role of optical coherence tomography (oct) in the diagnosis and management of retinal angiomatous proliferation (rap) in patients with age-related macular degeneration
    • Politoa A, Napolitano MC, Bandello F, et al: The role of optical coherence tomography (OCT) in the diagnosis and management of retinal angiomatous proliferation (RAP) in patients with age-related macular degeneration. Ann Acad Med Singapore 2006; 35: 420-424.
    • (2006) Ann Acad Med Singapore , vol.35 , pp. 420-424
    • Politoa, A.1    Napolitano, M.C.2    Bandello, F.3
  • 6
    • 0034900136 scopus 로고    scopus 로고
    • Reproducibility of retinal mapping using optical coherence tomography
    • Massin P, Vicaut E, Haouchine B, et al: Reproducibility of retinal mapping using optical coherence tomography. Arch Ophthalmol 2001; 119: 1135-1142.
    • (2001) Arch Ophthalmol , vol.119 , pp. 1135-1142
    • Massin, P.1    Vicaut, E.2    Haouchine, B.3
  • 7
    • 26444608689 scopus 로고    scopus 로고
    • Repeatability and reproducibility of fast macular thickness mapping with stratus optical coherence tomography
    • Polito A, Del Borrello M, Isola M, et al: Repeatability and reproducibility of fast macular thickness mapping with stratus optical coherence tomography. Arch Ophthalmol 2005; 123: 1330-1337.
    • (2005) Arch Ophthalmol , vol.123 , pp. 1330-1337
    • Polito, A.1    Del Borrello, M.2    Isola, M.3
  • 8
    • 38349061687 scopus 로고    scopus 로고
    • Results and repeatability of retinal thickness measurements from certification submissions
    • Danis RP, Fisher MR, Lambert E, et al: Results and repeatability of retinal thickness measurements from certification submissions. Arch Ophthalmol 2008; 126: 45-50.
    • (2008) Arch Ophthalmol , vol.126 , pp. 45-50
    • Danis, R.P.1    Fisher, M.R.2    Lambert, E.3
  • 9
    • 34547204477 scopus 로고    scopus 로고
    • Reproducibility of macular thickness and volume using zeiss optical coherence tomography in patients with diabetic macular edema
    • Krzystolik MG, Strauber SF, Aiello LP, et al: Reproducibility of macular thickness and volume using Zeiss optical coherence tomography in patients with diabetic macular edema. Ophthalmology 2007; 114: 1520-1525.
    • (2007) Ophthalmology , vol.114 , pp. 1520-1525
    • Krzystolik, M.G.1    Strauber, S.F.2    Aiello, L.P.3
  • 10
    • 25844456000 scopus 로고    scopus 로고
    • Three-dimensional retinal imaging with high-speed ultra-high resolution optical coherence tomography
    • Wojtkowski M, Srinivasan V, Fujimoto JG, et al: Three-dimensional retinal imaging with high-speed ultra-high resolution optical coherence tomography. Ophthalmology 2005; 112: 1734-1746.
    • (2005) Ophthalmology , vol.112 , pp. 1734-1746
    • Wojtkowski, M.1    Srinivasan, V.2    Fujimoto, J.G.3
  • 11
    • 33746318375 scopus 로고    scopus 로고
    • Clinical application of rapid serial Fourier-domain optical coherence tomography for macular imaging
    • Alam S, Zawadzki RJ, Choi S, et al: Clinical application of rapid serial Fourier-domain optical coherence tomography for macular imaging. Ophthalmology 2006; 113: 1425-1431.
    • (2006) Ophthalmology , vol.113 , pp. 1425-1431
    • Alam, S.1    Zawadzki, R.J.2    Choi, S.3
  • 12
    • 33947572962 scopus 로고    scopus 로고
    • Threedimensional imaging of macular holes with high-speed optical coherence tomography
    • Hangai M, Ojima Y, Gotoh N, et al: Threedimensional imaging of macular holes with high-speed optical coherence tomography. Ophthalmology 2007; 114: 763-773.
    • (2007) Ophthalmology , vol.114 , pp. 763-773
    • Hangai, M.1    Ojima, Y.2    Gotoh, N.3
  • 13
    • 36549064227 scopus 로고    scopus 로고
    • Threedimensional imaging of the foveal photoreceptor layer in central serous chorioretinopathy using high-speed optical coherence tomography
    • Ojima Y, Hangai M, Sasahara M, et al: Threedimensional imaging of the foveal photoreceptor layer in central serous chorioretinopathy using high-speed optical coherence tomography. Ophthalmology 2007; 114: 2197-2207.
    • (2007) Ophthalmology , vol.114 , pp. 2197-2207
    • Ojima, Y.1    Hangai, M.2    Sasahara, M.3
  • 14
    • 33749043671 scopus 로고    scopus 로고
    • Three-dimensional imaging of pigment epithelial detachment in age-related macular degeneration using optical coherence tomography, retinal thickness analysis and topographic angiography
    • Ahlers C, Michels S, Beckendorf A, et al: Three-dimensional imaging of pigment epithelial detachment in age-related macular degeneration using optical coherence tomography, retinal thickness analysis and topographic angiography. Graefes Arch Clin Exp Ophthalmol 2006; 244: 1233-1239.
    • (2006) Graefes Arch Clin Exp Ophthalmol , vol.244 , pp. 1233-1239
    • Ahlers, C.1    Michels, S.2    Beckendorf, A.3
  • 15
    • 0022347471 scopus 로고
    • Photocoagulation for diabetic macular edema: Early treatment diabetic retinopathy study report number 1
    • Early Treatment Diabetic Retinopathy Study Research Group
    • Early Treatment Diabetic Retinopathy Study Research Group: Photocoagulation for diabetic macular edema: Early Treatment Diabetic Retinopathy Study report number 1. Arch Ophthalmol 1985; 103: 1796-1806.
    • (1985) Arch Ophthalmol , vol.103 , pp. 1796-1806
  • 16
    • 48149104805 scopus 로고    scopus 로고
    • Optical coherence tomography measurements and analysis methods in optical coherence tomography studies of diabetic macular edema
    • 1371.e1
    • Browning DJ, Glassman AR, Aiello LP, et al; Diabetic Retinopathy Clinical Research Network: Optical coherence tomography measurements and analysis methods in optical coherence tomography studies of diabetic macular edema. Ophthalmology 2008; 115: 1366-1371, 1371.e1.
    • (2008) Ophthalmology , vol.115 , pp. 1366-1371
    • Browning, D.J.1    Glassman, A.R.2    Aiello, L.P.3
  • 17
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG: Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986; 1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 19
    • 84877603098 scopus 로고    scopus 로고
    • Repeatability and reproducibility of retinal thickness measurements in diabetic patients with spectral domain optical coherence tomography
    • Fiore T, Androudi S, Iaccheri B, Lupidi M, Giansanti F, Fruttini D, Biondi L, Cagini C: Repeatability and reproducibility of retinal thickness measurements in diabetic patients with spectral domain optical coherence tomography. Curr Eye Res 2013; 38: 674-679.
    • (2013) Curr Eye Res , vol.38 , pp. 674-679
    • Fiore, T.1    Androudi, S.2    Iaccheri, B.3    Lupidi, M.4    Giansanti, F.5    Fruttini, D.6    Biondi, L.7    Cagini, C.8
  • 20
    • 3042668265 scopus 로고    scopus 로고
    • Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using stratus oct
    • Paunescu LA, Schuman JS, Prince LL, et al: Reproducibility of nerve fiber thickness, macular thickness, and optic nerve head measurements using Stratus OCT. Invest Ophthalmol Vis Sci 2004; 45: 1716-1724.
    • (2004) Invest Ophthalmol Vis Sci , vol.45 , pp. 1716-1724
    • Paunescu, L.A.1    Schuman, J.S.2    Prince, L.L.3
  • 21
    • 53449092950 scopus 로고    scopus 로고
    • Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema
    • Forooghian F, Cukras C, Meyerle CB, Chew EY, Wong WT: Evaluation of time domain and spectral domain optical coherence tomography in the measurement of diabetic macular edema. Invest Ophthalmol Vis Sci 2008; 49: 4290-4296.
    • (2008) Invest Ophthalmol Vis Sci , vol.49 , pp. 4290-4296
    • Forooghian, F.1    Cukras, C.2    Meyerle, C.B.3    Chew, E.Y.4    Wong, W.T.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.