메뉴 건너뛰기




Volumn 9, Issue 4, 2015, Pages 270-276

Optimization and application of imprinted poly(AA-EGDMA) for solid phase extraction of ciprofloxacin in artificial urine

Author keywords

Ciprofloxacin; Molecularly imprinted polymers; Optimization; Solid phase extraction

Indexed keywords

CIPROFLOXACIN; ETHYLENE GLYCOL DIMETHACRYLATE; MOLECULARLY IMPRINTED POLYMER;

EID: 84930517997     PISSN: 15748855     EISSN: 10657630     Source Type: Journal    
DOI: 10.2174/1574885510999150505160637     Document Type: Article
Times cited : (6)

References (26)
  • 1
    • 79551511486 scopus 로고    scopus 로고
    • Ciprofloxacinimprinted polymeric receptors as ionophores for potentiometric transduction
    • Oliveira H.M.V, Moreira F.T.C, Sales M.G.F. Ciprofloxacinimprinted polymeric receptors as ionophores for potentiometric transduction. Electrochimica Acta 2011; 56(5): 2017-23.
    • (2011) Electrochimica Acta , vol.56 , Issue.5 , pp. 2017-2023
    • Oliveira, H.1    Moreira, F.2    Sales, M.3
  • 2
    • 57249095762 scopus 로고    scopus 로고
    • Synthesis and application of a peroxidase-like molecularly imprinted polymer based on hemin for selective determination of serotonin in blood serum
    • Rodrigues Santos W.D.J, Lima P.R, Tarley C.R.T, Hoehr N.F, Kubota L.T. Synthesis and application of a peroxidase-like molecularly imprinted polymer based on hemin for selective determination of serotonin in blood serum. Anal Chim Acta 2009; 631(2): 170-6.
    • (2009) Anal Chim Acta , vol.631 , Issue.2 , pp. 170-176
    • Rodrigues Santos, W.1    Lima, P.R.2    Tarley, C.3    Hoehr, N.F.4    Kubota, L.T.5
  • 3
    • 0347627278 scopus 로고    scopus 로고
    • Ni(II) ion-imprinted solid-phase extraction and preconcentration in aqueous solutions by packedbed columns
    • Ersoz A, Say R, Denizli A. Ni(II) ion-imprinted solid-phase extraction and preconcentration in aqueous solutions by packedbed columns. Anal Chim Acta 2004; 502(1): 91-7.
    • (2004) Anal Chim Acta , vol.502 , Issue.1 , pp. 91-97
    • Ersoz, A.1    Say, R.2    Denizli, A.3
  • 4
    • 30844460364 scopus 로고    scopus 로고
    • Polímeros biomiméticos em química analítica. Parte 1: Preparo e aplicações de MIP ("Molecularly Imprinted Polymers") em técnicas de extração e separação
    • Tarley C.R.T, Sotomayor M.D.P.T, Kubota L.T. Polímeros biomiméticos em química analítica. Parte 1: preparo e aplicações de MIP ("Molecularly Imprinted Polymers") em técnicas de extração e separação. Quim Nova 2005; 28: 1076-86.
    • (2005) Quim Nova , vol.28 , pp. 1076-1086
    • Tarley, C.1    Sotomayor, M.2    Kubota, L.T.3
  • 5
    • 30944437480 scopus 로고    scopus 로고
    • Polímeros biomiméticos em química analítica. Parte 2: Aplicações de MIP ("Molecularly Imprinted Polymers") no desenvolvimento de sensores químicos
    • Tarley C.R.T, Sotomayor M.D.P.T, Kubota L.T. Polímeros biomiméticos em química analítica. Parte 2: aplicações de MIP ("Molecularly Imprinted Polymers") no desenvolvimento de sensores químicos. Quim Nova 2005; 28: 1087-101.
    • (2005) Quim Nova , vol.28 , pp. 1087-1101
    • Tarley, C.1    Sotomayor, M.2    Kubota, L.T.3
  • 6
    • 84896511534 scopus 로고    scopus 로고
    • Development of a selective and sensitive voltammetric sensor for propylparaben based on a nanosized molecularly imprinted polymer-carbon paste electrode
    • Gholivand M.B, Shamsipur M, Dehdashtian S, Rajabi H.R. Development of a selective and sensitive voltammetric sensor for propylparaben based on a nanosized molecularly imprinted polymer-carbon paste electrode. Mat Sc Eng C 2014; 36: 102-7.
    • (2014) Mat Sc Eng C , vol.36 , pp. 102-107
    • Gholivand, M.B.1    Shamsipur, M.2    Dehdashtian, S.3    Rajabi, H.R.4
  • 7
    • 84873964920 scopus 로고    scopus 로고
    • Development of a highly selective voltammetric sensor for nanomolar detection of mercury ions using glassy carbon electrode modified with a novel ion imprinted polymeric nanobeads and multi-wall carbon nanotubes
    • Rajabi H.R, Roushani M, Shamsipur M. Development of a highly selective voltammetric sensor for nanomolar detection of mercury ions using glassy carbon electrode modified with a novel ion imprinted polymeric nanobeads and multi-wall carbon nanotubes. J Electroanal Chem 2013; 693: 16-22.
    • (2013) J Electroanal Chem , vol.693 , pp. 16-22
    • Rajabi, H.R.1    Roushani, M.2    Shamsipur, M.3
  • 8
    • 79953745448 scopus 로고    scopus 로고
    • Development of ion imprinted technique for designing nickel ion selective membrane
    • Vatanpour V, Madaeni S.S, Zinadini S, Rajabi H.R. Development of ion imprinted technique for designing nickel ion selective membrane. J Membrane Sc 2011; 373(1-2): 36-42.
    • (2011) J Membrane Sc , vol.373 , Issue.1-2 , pp. 36-42
    • Vatanpour, V.1    Madaeni, S.S.2    Zinadini, S.3    Rajabi, H.R.4
  • 9
    • 84855679163 scopus 로고    scopus 로고
    • Ionic liquid-modified materials for solid-phase extraction and separation: A review
    • Vidal L, Riekkola M.L, Canals A. Ionic liquid-modified materials for solid-phase extraction and separation: A review. Anal Chim Acta 2012; 715: 19-41.
    • (2012) Anal Chim Acta , vol.715 , pp. 19-41
    • Vidal, L.1    Riekkola, M.L.2    Canals, A.3
  • 10
    • 84555178020 scopus 로고    scopus 로고
    • Developments in coupled solid-phase extraction-capillary electrophoresis 2009-2011
    • Ramautar R, de Jong G.J, Somsen G.W. Developments in coupled solid-phase extraction-capillary electrophoresis 2009-2011. Electrophoresis 2012; 33(1): 243-50.
    • (2012) Electrophoresis , vol.33 , Issue.1 , pp. 243-250
    • Ramautar, R.1    De Jong, G.J.2    Somsen, G.W.3
  • 11
    • 84859884267 scopus 로고    scopus 로고
    • Chromatography, Solid-Phase Extraction and Capillary Electrochromatography with MIPs
    • Toth B, Horvai G. Chromatography, Solid-Phase Extraction and Capillary Electrochromatography with MIPs. Molecular Imprinting 2012; 325: 267-306.
    • (2012) Molecular Imprinting , vol.325 , pp. 267-306
    • Toth, B.1    Horvai, G.2
  • 12
    • 84862988207 scopus 로고    scopus 로고
    • Solid-phase extraction in the determination of gold, palladium, and platinum
    • Mladenova E, Karadjova I, Tsalev D.L. Solid-phase extraction in the determination of gold, palladium, and platinum. J Sc 2012; 35(10-11): 1249-65.
    • (2012) J Sc , vol.35 , Issue.10-11 , pp. 1249-1265
    • Mladenova, E.1    Karadjova, I.2    Tsalev, D.L.3
  • 13
    • 84866995368 scopus 로고    scopus 로고
    • Carbon nanotubes as solid-phase extraction sorbents prior to atomic spectrometric determination of metal species: A review
    • Latorre C.H, Mendez J.A, Garcia J.B, Martin S.G, Crecente R.M.P. Carbon nanotubes as solid-phase extraction sorbents prior to atomic spectrometric determination of metal species: A review. Anal Chim Acta 2012; 749: 16-35.
    • (2012) Anal Chim Acta , vol.749 , pp. 16-35
    • Latorre, C.H.1    Mendez, J.A.2    Garcia, J.B.3    Martin, S.G.4    Crecente, R.5
  • 14
    • 84872663655 scopus 로고    scopus 로고
    • Flame photometric determination of cesium ion after its preconcentration with nanoparticles imprinted with the cesium-dibenzo-24-crown-8 complex
    • Shamsipur M, Rajabi H. Flame photometric determination of cesium ion after its preconcentration with nanoparticles imprinted with the cesium-dibenzo-24-crown-8 complex. Microchim Acta 2013; 180(3/4): 243-52.
    • (2013) Microchim Acta , vol.180 , Issue.3-4 , pp. 243-252
    • Shamsipur, M.1    Rajabi, H.2
  • 15
    • 0037174691 scopus 로고    scopus 로고
    • Extraction of clenbuterol from calf urine using a molecularly imprinted polymer followed by quantitation by highperformance liquid chromatography with UV detection
    • Blomgren A, Berggren C, Holmberg A, Larsson F, Sellergren B, Ensing K. Extraction of clenbuterol from calf urine using a molecularly imprinted polymer followed by quantitation by highperformance liquid chromatography with UV detection. J Chromatogr A 2002; 975(1): 157-64.
    • (2002) J Chromatogr A , vol.975 , Issue.1 , pp. 157-164
    • Blomgren, A.1    Berggren, C.2    Holmberg, A.3    Larsson, F.4    Sellergren, B.5    Ensing, K.6
  • 16
    • 5144231570 scopus 로고    scopus 로고
    • Analysis of triazine in water samples by solid-phase microextraction coupled with highperformance liquid chromatography
    • Huang S.D, Huang H.I, Sung Y.H. Analysis of triazine in water samples by solid-phase microextraction coupled with highperformance liquid chromatography. Talanta 2004; 64(4): 887-93.
    • (2004) Talanta , vol.64 , Issue.4 , pp. 887-893
    • Huang, S.D.1    Huang, H.I.2    Sung, Y.H.3
  • 17
    • 33746393851 scopus 로고    scopus 로고
    • Determination of DL-tetrahydropalmatine in Corydalis yanhusuo by Ltetrahydropalmatine imprinted monolithic column coupling with reversed-phase high performance liquid chromatography
    • Ou J.J, Kong L, Pan CS, Su X.Y, Lei X.Y, Zou H.F. Determination of DL-tetrahydropalmatine in Corydalis yanhusuo by Ltetrahydropalmatine imprinted monolithic column coupling with reversed-phase high performance liquid chromatography. J Chromatogr A 2006; 1117(2): 163-9.
    • (2006) J Chromatogr A , vol.1117 , Issue.2 , pp. 163-169
    • Ou, J.J.1    Kong, L.2    Pan, C.S.3    Su, X.Y.4    Lei, X.Y.5    Zou, H.F.6
  • 18
    • 84872619239 scopus 로고    scopus 로고
    • Preparation of molecularly imprinted polymer nanoparticles for selective removal of fluoroquinolone antibiotics in aqueous solution
    • Tan F, Sun D, Gao J, Zhao Q, Wang X, Teng F, et al.Preparation of molecularly imprinted polymer nanoparticles for selective removal of fluoroquinolone antibiotics in aqueous solution. J Hazard Mat 2013; 244(1): 750-57.
    • (2013) J Hazard Mat , vol.244 , Issue.1 , pp. 750-757
    • Tan, F.1    Sun, D.2    Gao, J.3    Zhao, Q.4    Wang, X.5    Teng, F.6
  • 19
    • 27844551257 scopus 로고    scopus 로고
    • Optimization, evaluation, and characterization of molecularly imprinted polymers
    • Spivak D.A. Optimization, evaluation, and characterization of molecularly imprinted polymers. Adv Drug Deliv Rev 2005; 57(12): 1779-94.
    • (2005) Adv Drug Deliv Rev , vol.57 , Issue.12 , pp. 1779-1794
    • Spivak, D.A.1
  • 21
    • 84884510307 scopus 로고    scopus 로고
    • Ion imprinted polymeric nanoparticles for selective separation and sensitive determination of zinc ions in different matrices
    • Shamsipur M, Rajabi H.R, Pourmortazavi S.M, Roushani M. Ion imprinted polymeric nanoparticles for selective separation and sensitive determination of zinc ions in different matrices. Spectrochim Acta Part A: Molec Biomol Spectrosc 2014; 117: 24-33.
    • (2014) Spectrochim Acta Part A: Molec Biomol Spectrosc , vol.117 , pp. 24-33
    • Shamsipur, M.1    Rajabi, H.R.2    Pourmortazavi, S.M.3    Roushani, M.4
  • 22
    • 84864951979 scopus 로고    scopus 로고
    • Breakthrough Curve Analysis for Column Dynamics Sorption of Mn(II) Ions from Wastewater by Using Mangostana garcinia Peel-Based Granular-Activated Carbon
    • Chowdhury Z.Z, Zain S.M, Rashid A.K, Rafique R.F, Khalid K. Breakthrough Curve Analysis for Column Dynamics Sorption of Mn(II) Ions from Wastewater by Using Mangostana garcinia Peel-Based Granular-Activated Carbon. J Chem 2013; 2013: 1-8.
    • (2013) J Chem , vol.2013 , pp. 1-8
    • Chowdhury, Z.Z.1    Zain, S.M.2    Rashid, A.K.3    Rafique, R.F.4    Khalid, K.5
  • 23
    • 79959716329 scopus 로고    scopus 로고
    • Biomimetic ciprofloxacin sensors made of molecularly imprinted network receptors for potential measurements
    • Kamel A.H, Mahmoud W.H, Mostafa M.S. Biomimetic ciprofloxacin sensors made of molecularly imprinted network receptors for potential measurements. Anal Meth 2011; 3(4): 957-64.
    • (2011) Anal Meth , vol.3 , Issue.4 , pp. 957-964
    • Kamel, A.H.1    Mahmoud, W.H.2    Mostafa, M.S.3
  • 24
    • 0031747550 scopus 로고    scopus 로고
    • Determination of ciprofloxacin in plasma and urine by HPLC with ultraviolet detection
    • Kamberi M, Tsutsumi K, Kotegawa T, Nakamura K, Nakano S. Determination of ciprofloxacin in plasma and urine by HPLC with ultraviolet detection. Clin Chem 1998; 44(6): 1251-5.
    • (1998) Clin Chem , vol.44 , Issue.6 , pp. 1251-1255
    • Kamberi, M.1    Tsutsumi, K.2    Kotegawa, T.3    Nakamura, K.4    Nakano, S.5
  • 25
    • 44249085656 scopus 로고    scopus 로고
    • Novel molecularly imprinted monolithic column for selective on-line extraction of ciprofloxacin from human urine
    • Yan H, Row K.H. Novel molecularly imprinted monolithic column for selective on-line extraction of ciprofloxacin from human urine. Biomed Chromatogr 2008; 22(5): 487-493.
    • (2008) Biomed Chromatogr , vol.22 , Issue.5 , pp. 487-493
    • Yan, H.1    Row, K.H.2
  • 26
    • 39649098225 scopus 로고    scopus 로고
    • Water-compatible molecularly imprinted polymers for selective extraction of ciprofloxacin from human urine
    • Yan H, Row K.H, Yang G. Water-compatible molecularly imprinted polymers for selective extraction of ciprofloxacin from human urine. Talanta 2008; 75(1): 227-232.
    • (2008) Talanta , vol.75 , Issue.1 , pp. 227-232
    • Yan, H.1    Row, K.H.2    Yang, G.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.