메뉴 건너뛰기




Volumn 9, Issue 5, 2014, Pages 343-348

Midterm outcomes after transcatheter aortic valve implantation

Author keywords

Aortic stenosis; Midterm outcomes; Transcatheter aortic valve implantation

Indexed keywords

AGED; AORTA OCCLUSION; AORTA VALVE STENOSIS; ARTICLE; CARDIOVASCULAR MORTALITY; CEREBROVASCULAR ACCIDENT; CONTROLLED STUDY; DEVICE COMPARISON; EUROSCORE; EUROSCORE I; FEMALE; FLUOROSCOPY; FOLLOW UP; HEART DISEASE; HIGH RISK PATIENT; HUMAN; MAJOR CLINICAL STUDY; MALE; MEDICAL DEVICE COMPLICATION; OPERATION DURATION; PACEMAKER IMPLANTATION; PERCUTANEOUS AORTIC VALVE; PERCUTANEOUS AORTIC VALVE MIGRATION; PRIORITY JOURNAL; TRANSCATHETER AORTIC VALVE IMPLANTATION; TREATMENT OUTCOME; TREATMENT RESPONSE; VALVULAR HEART DISEASE; VASCULAR DISEASE; VENTRICULAR EMBOLIZATION; WOUND COMPLICATION; AORTA VALVE; AORTIC VALVE STENOSIS; ARTIFICIAL HEART PACEMAKER; BIOPROSTHESIS; FOREIGN-BODY MIGRATION; HEART CATHETERIZATION; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; MORTALITY; PATIENT SELECTION; POSTOPERATIVE COMPLICATION; PROCEDURES; STATISTICS AND NUMERICAL DATA; STROKE; VERY ELDERLY;

EID: 84930516720     PISSN: 15569845     EISSN: 15590879     Source Type: Journal    
DOI: 10.1097/IMI.0000000000000097     Document Type: Article
Times cited : (4)

References (12)
  • 1
    • 84867326319 scopus 로고    scopus 로고
    • Transcatheter aortic valve implantation 10-year anniversary: Review of current evidence and clinical implications
    • Généreux P, Head SJ, Wood DA, et al. Transcatheter aortic valve implantation 10-year anniversary: review of current evidence and clinical implications. Eur Heart J. 2012;33:2388-2398.
    • (2012) Eur Heart J. , vol.33 , pp. 2388-2398
    • Généreux, P.1    Head, S.J.2    Wood, D.A.3
  • 2
    • 0037058854 scopus 로고    scopus 로고
    • Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: First human case description
    • Cribier A, Eltchaninoff H, Bash A, et al. Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis: first human case description. Circulation. 2002;106:3006-3008.
    • (2002) Circulation , vol.106 , pp. 3006-3008
    • Cribier, A.1    Eltchaninoff, H.2    Bash, A.3
  • 3
    • 34250815116 scopus 로고    scopus 로고
    • Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- And current third-generation self-expanding corevalve prosthesis: Device success and 30-day clinical outcome
    • Grube E, Schuler G, Buellesfeld L, et al. Percutaneous aortic valve replacement for severe aortic stenosis in high-risk patients using the second- And current third-generation self-expanding CoreValve prosthesis: device success and 30-day clinical outcome. J Am Coll Cardiol. 2007;50:69-76.
    • (2007) J Am Coll Cardiol , vol.50 , pp. 69-76
    • Grube, E.1    Schuler, G.2    Buellesfeld, L.3
  • 4
    • 67650088413 scopus 로고    scopus 로고
    • Results of transfemoral or transapical aortic valve implantation following a uniform assessment in high-risk patients with aortic stenosis
    • Himbert D, Descoutures F, Al-Attar N, et al. Results of transfemoral or transapical aortic valve implantation following a uniform assessment in high-risk patients with aortic stenosis. J Am Coll Cardiol. 2009;54: 303-311.
    • (2009) J Am Coll Cardiol , vol.54 , pp. 303-311
    • Himbert, D.1    Descoutures, F.2    Al-Attar, N.3
  • 5
    • 84860436228 scopus 로고    scopus 로고
    • Registry of transcatheter aorticvalve implantation in high-risk patients
    • Gilard M, Eltchaninoff H, Iung B, et al. Registry of transcatheter aorticvalve implantation in high-risk patients. N Engl J Med. 2012;366: 1705-1715.
    • (2012) N Engl J Med. , vol.366 , pp. 1705-1715
    • Gilard, M.1    Eltchaninoff, H.2    Iung, B.3
  • 6
    • 84867283287 scopus 로고    scopus 로고
    • Guidelines on the management of valvular heart disease (version 2012)
    • Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC); European Association for Cardio- Thoracic Surgery (EACTS)
    • Joint Task Force on the Management of Valvular Heart Disease of the European Society of Cardiology (ESC); European Association for Cardio- Thoracic Surgery (EACTS); Vahanian A, Alfieri O, Andreotti F, et al. Guidelines on the management of valvular heart disease (version 2012). Eur Heart J. 2012;33:2451-2496.
    • (2012) Eur Heart J. , vol.33 , pp. 2451-2496
    • Vahanian, A.1    Alfieri, O.2    Andreotti, F.3
  • 7
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • Smith CR, Leon MB, Mack MJ, et al. Transcatheter versus surgical aortic-valve replacement in high-risk patients.NEngl J Med. 2011;364: 2187-2198.
    • (2011) NEngl J Med. , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    Mack, M.J.3
  • 8
    • 57749202934 scopus 로고    scopus 로고
    • Transapical aortic valve implantation: Step by step
    • Walther T, Dewey T, Borger MA, et al. Transapical aortic valve implantation: Step by step. Ann Thorac Surg. 2009;87:276-283.
    • (2009) Ann Thorac, Surg , vol.87 , pp. 276-283
    • Walther, T.1    Dewey, T.2    Borger, M.A.3
  • 9
    • 84866983406 scopus 로고    scopus 로고
    • Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document
    • Kappetein AP, Head SJ, Généreux P, et al. Updated standardized endpoint definitions for transcatheter aortic valve implantation: The Valve Academic Research Consortium-2 consensus document. J Am Coll Cardiol. 2012;60: 1438-1454.
    • (2012) J Am Coll Cardiol , vol.60 , pp. 1438-1454
    • Kappetein, A.P.1    Head, S.J.2    Généreux, P.3
  • 10
    • 84868198060 scopus 로고    scopus 로고
    • Long-term outcomes after transcatheter aortic valve implantation: Insights on prognostic factors and valve durability from the canadian multicenter experience
    • Rodés-Cabau J, Webb JG, Cheung A, et al. Long-term outcomes after transcatheter aortic valve implantation: insights on prognostic factors and valve durability from the Canadian multicenter experience. J Am Coll Cardiol. 2012;60:1864-1875.
    • (2012) J Am Coll Cardiol , vol.60 , pp. 1864-1875
    • Rodés-Cabau, J.1    Webb, J.G.2    Cheung, A.3
  • 11
    • 84872685837 scopus 로고    scopus 로고
    • 5-Year outcome after transcatheter aortic valve implantation
    • Toggweiler S, Humphries KH, Lee M, et al. 5-year outcome after transcatheter aortic valve implantation. J Am Coll Cardiol. 2013;61:413-419.
    • (2013) J Am Coll Cardiol , vol.61 , pp. 413-419
    • Toggweiler, S.1    Humphries, K.H.2    Lee, M.3
  • 12
    • 84871262958 scopus 로고    scopus 로고
    • Impact of a new conduction defect after transcatheter aortic valve implantation on left ventricular function
    • Hoffmann R, Herpertz R, Lotfipour S, et al. Impact of a new conduction defect after transcatheter aortic valve implantation on left ventricular function. JACC Cardiovasc Interv. 2012;5:1257-1263.
    • (2012) JACC Cardiovasc Interv , vol.5 , pp. 1257-1263
    • Hoffmann, R.1    Herpertz, R.2    Lotfipour, S.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.