메뉴 건너뛰기




Volumn 8, Issue 3, 2015, Pages 932-958

A critical review of dental implant materials with an emphasis on titanium versus zirconia

Author keywords

Dental implants; Implant materials; Oral implants; Titanium; Zirconia

Indexed keywords

FAILURE (MECHANICAL); TITANIUM; ZIRCONIA;

EID: 84930507396     PISSN: None     EISSN: 19961944     Source Type: Journal    
DOI: 10.3390/ma8030932     Document Type: Review
Times cited : (407)

References (151)
  • 2
    • 0027564588 scopus 로고
    • Dental implants: Materials and design considerations
    • Smith, D.C. Dental implants: Materials and design considerations. Int. J. Prosthodont. 1993, 6, 106-117.
    • (1993) Int. J. Prosthodont , vol.6 , pp. 106-117
    • Smith, D.C.1
  • 3
    • 0022118623 scopus 로고
    • Titanium: The mystery metal of implant dentistry. Dental materials aspect.
    • Parr, G.R.; Gardner, L.K.; Toth, R.W. Titanium: The mystery metal of implant dentistry. Dental materials aspect. J. Prosthet. Dent. 1985, 54, 410-414.
    • (1985) J. Prosthet. Dent , vol.54 , pp. 410-414
    • Parr, G.R.1    Gardner, L.K.2    Toth, R.W.3
  • 4
    • 0034267040 scopus 로고    scopus 로고
    • Implant materials, designs, and surface topographies: Their effect on osseointegration. A literature review.
    • Sykaras, N.; Lacopino, A.M.; Marker, V.A.; Triplett, R.G.; Woody, R.D. Implant materials, designs, and surface topographies: Their effect on osseointegration. A literature review. Int. J. Oral Maxillofac. Implants 2000, 15, 675-690.
    • (2000) Int. J. Oral Maxillofac. Implants , vol.15 , pp. 675-690
    • Sykaras, N.1    Lacopino, A.M.2    Marker, V.A.3    Triplett, R.G.4    Woody, R.D.5
  • 5
    • 0019425197 scopus 로고
    • Implants in dental and maxillofacial surgery.
    • Williams, D.E. Implants in dental and maxillofacial surgery. Biomaterials 1981, 2, 133-146.
    • (1981) Biomaterials , vol.2 , pp. 133-146
    • Williams, D.E.1
  • 6
    • 0025579644 scopus 로고
    • Dental implants biomaterials
    • Lemons, J.E. Dental implants biomaterials. J. Am. Dent. Assoc. 1990, 121, 716-719.
    • (1990) J. Am. Dent. Assoc , vol.121 , pp. 716-719
    • Lemons, J.E.1
  • 7
    • 0004057280 scopus 로고
    • 9th ed.; C.V. Mosby: St. Louis, MO, USA
    • Craig, R.G. Restorative Dental Materials; 9th ed.; C.V. Mosby: St. Louis, MO, USA, 1993; p. 169.
    • (1993) Restorative Dental Materials , pp. 169
    • Craig, R.G.1
  • 8
    • 84930508409 scopus 로고    scopus 로고
    • The in vitro response of human osteoblasts to polyetheretherketone (PEEK) substrates compared to commercially pure titanium
    • Sagomonyants, K.B.; Jarman-Smith, M.L.; Devine, J.N.; Aronow, M.S.; Gronowicz, G.A. The in vitro response of human osteoblasts to polyetheretherketone (PEEK) substrates compared to commercially pure titanium. Biomaterials 2007, 24, 3115-3123.
    • (2007) Biomaterials , vol.24 , pp. 3115-3123
    • Sagomonyants, K.B.1    Jarman-Smith, M.L.2    Devine, J.N.3    Aronow, M.S.4    Gronowicz, G.A.5
  • 10
    • 0025583364 scopus 로고
    • A long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws
    • Adell, R.; Eriksson, B.; Lekholm, U.; Brånemark, P.I.; Jemt, T. A long-term follow-up study of osseointegrated implants in the treatment of totally edentulous jaws. Int. J. Oral Maxillofac. Implants 1990, 5, 347-359.
    • (1990) Int. J. Oral Maxillofac. Implants , vol.5 , pp. 347-359
    • Adell, R.1    Eriksson, B.2    Lekholm, U.3    Brånemark, P.I.4    Jemt, T.5
  • 12
    • 0032023387 scopus 로고    scopus 로고
    • Mechanical properties of biomedical titanium alloy
    • Niinomi, M. Mechanical properties of biomedical titanium alloy. Mat. Sci. Eng. A 1998, 243, 231-236.
    • (1998) Mat. Sci. Eng. A , vol.243 , pp. 231-236
    • Niinomi, M.1
  • 13
    • 0030075125 scopus 로고    scopus 로고
    • Materials for endosseous dental implants
    • Wataha, J.C. Materials for endosseous dental implants. J. Oral Rehabil. 1996, 23, 79-90.
    • (1996) J. Oral Rehabil , vol.23 , pp. 79-90
    • Wataha, J.C.1
  • 14
    • 0033087665 scopus 로고    scopus 로고
    • Dental implant materials: Commercially pure titanium and titanium alloys
    • McCracken, M. Dental implant materials: Commercially pure titanium and titanium alloys. J. Prosthodont. 1999, 8, 40-43.
    • (1999) J. Prosthodont , vol.8 , pp. 40-43
    • McCracken, M.1
  • 15
    • 0345504724 scopus 로고    scopus 로고
    • Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications
    • González, J.E.G.; Mirza-Rosca, J.C. Study of the corrosion behavior of titanium and some of its alloys for biomedical and dental implant applications. J. Electroanal Chem. 1999, 471, 109-115.
    • (1999) J. Electroanal Chem , vol.471 , pp. 109-115
    • González, J.E.G.1    Mirza-Rosca, J.C.2
  • 16
    • 0027023585 scopus 로고
    • Force transfer in implant dentistry: Basic concepts and principles
    • Bidez, M.W.; Misch, C.F. Force transfer in implant dentistry: Basic concepts and principles. J. Oral Implantol. 1992, 18, 264-274.
    • (1992) J. Oral Implantol , vol.18 , pp. 264-274
    • Bidez, M.W.1    Misch, C.F.2
  • 17
    • 77954034122 scopus 로고    scopus 로고
    • Determination of Young's modulus of mandibular bone using inverse analysis
    • Odin, G.; Savoldelli, C.; Bouchard, P.O.; Tillier, Y. Determination of Young's modulus of mandibular bone using inverse analysis. Med. Eng. Phys. 2010, 32, 630-637.
    • (2010) Med. Eng. Phys , vol.32 , pp. 630-637
    • Odin, G.1    Savoldelli, C.2    Bouchard, P.O.3    Tillier, Y.4
  • 18
    • 84866178341 scopus 로고    scopus 로고
    • A review of titanium zirconium (TiZr) alloys for use in endosseous dental implants
    • Grandin, H.M.; Berner, S.; Dart, M. A review of titanium zirconium (TiZr) alloys for use in endosseous dental implants. Materials 2015, 5, 1348-1360.
    • (2015) Materials , vol.5 , pp. 1348-1360
    • Grandin, H.M.1    Berner, S.2    Dart, M.3
  • 19
    • 84929504973 scopus 로고    scopus 로고
    • Fracture of a narrow-diameter Roxolid implant: Clinical and fractographic considerations
    • Karl, M.; Krafft, T.; Kelly, J.R. Fracture of a narrow-diameter Roxolid implant: Clinical and fractographic considerations. Int. J. Oral Maxillofac. Implants 2014, 29, 1193-1196.
    • (2014) Int. J. Oral Maxillofac. Implants , vol.29 , pp. 1193-1196
    • Karl, M.1    Krafft, T.2    Kelly, J.R.3
  • 20
    • 77952107284 scopus 로고    scopus 로고
    • Reactive lesions of peri-implant mucosa associated with titanium dental implants: A report of 2 cases
    • Olmedo, D.G.; Paparella, M.L.; Brandizzi, D.; Cabrini, R.L. Reactive lesions of peri-implant mucosa associated with titanium dental implants: A report of 2 cases. Int. J. Oral Maxillofac. Surg. 2010, 39, 503-507.
    • (2010) Int. J. Oral Maxillofac. Surg , vol.39 , pp. 503-507
    • Olmedo, D.G.1    Paparella, M.L.2    Brandizzi, D.3    Cabrini, R.L.4
  • 21
    • 55249122493 scopus 로고    scopus 로고
    • Suspected association of an allergic reaction with titanium dental implants: A clinical report
    • Egusa, H.; Ko, N.; Shimazu, T.; Yatani, H. Suspected association of an allergic reaction with titanium dental implants: A clinical report. J. Prosthet. Dent. 2008, 100, 344-347.
    • (2008) J. Prosthet. Dent , vol.100 , pp. 344-347
    • Egusa, H.1    Ko, N.2    Shimazu, T.3    Yatani, H.4
  • 24
    • 64249084235 scopus 로고    scopus 로고
    • An overview of the corrosion aspect of dental implants (titanium and its alloys)
    • Chaturvedi, T.P. An overview of the corrosion aspect of dental implants (titanium and its alloys). Indian J. Dent. Res. 2009, 20, 91-98.
    • (2009) Indian J. Dent. Res , vol.20 , pp. 91-98
    • Chaturvedi, T.P.1
  • 26
    • 84873045367 scopus 로고    scopus 로고
    • Is titanium sensitivity associated with allergic reactions in patients with dental implants? A systematic review
    • Javed, F.; Al-Hezaimi, K.; Almas, K.; Romanos, G.E. Is titanium sensitivity associated with allergic reactions in patients with dental implants? A systematic review. Clin. Implant Dent. Relat. Res. 2013, 15, 47-52.
    • (2013) Clin. Implant Dent. Relat. Res , vol.15 , pp. 47-52
    • Javed, F.1    Al-Hezaimi, K.2    Almas, K.3    Romanos, G.E.4
  • 27
    • 0035108321 scopus 로고    scopus 로고
    • Metal sensitivity in patients with orthopaedic implants
    • Hallab, N.; Merritt, K.; Jacobs, J.J. Metal sensitivity in patients with orthopaedic implants. J. Bone Joint Surg. Am. 2001, 83, 428-436.
    • (2001) J. Bone Joint Surg. Am , vol.83 , pp. 428-436
    • Hallab, N.1    Merritt, K.2    Jacobs, J.J.3
  • 28
    • 0036719501 scopus 로고    scopus 로고
    • A study of titanium release into body organs following the insertion of single threaded screw implants into the mandibles of sheep
    • Frisken, K.W.; Dandie, G.W.; Lugowski, S.; Jordan, G. A study of titanium release into body organs following the insertion of single threaded screw implants into the mandibles of sheep. Aust. Dent. J. 2002, 47, 214-217.
    • (2002) Aust. Dent. J , vol.47 , pp. 214-217
    • Frisken, K.W.1    Dandie, G.W.2    Lugowski, S.3    Jordan, G.4
  • 29
    • 0026347807 scopus 로고
    • Release and excretion of metal in patients who have a total hip replacement component made of titanium- base alloy
    • Jacobs, J.J.; Skipor, A.K.; Black, J.; Urban, R.; Galante, J.O. Release and excretion of metal in patients who have a total hip replacement component made of titanium- base alloy. J. Bone Joint Surg. Am. 1991, 73, 1475-1486.
    • (1991) J. Bone Joint Surg. Am , vol.73 , pp. 1475-1486
    • Jacobs, J.J.1    Skipor, A.K.2    Black, J.3    Urban, R.4    Galante, J.O.5
  • 30
    • 0025874154 scopus 로고
    • Metal wear and tissue response in failed titanium alloy total hip replacements
    • Witt, J.D.; Swann, M. Metal wear and tissue response in failed titanium alloy total hip replacements. J. Bone Joint Surg. Br. 1991, 73, 559-563.
    • (1991) J. Bone Joint Surg. Br , vol.73 , pp. 559-563
    • Witt, J.D.1    Swann, M.2
  • 31
    • 0035234463 scopus 로고    scopus 로고
    • A case of allergic reaction to surgical metal clips inserted for postoperative boost irradiation in a patient undergoing breast conserving therapy
    • Tamai, K.; Mitsumori, M.; Fujishiro, S.; Kokubo, M.; Ooya, N.; Nagata, Y.; Sasai, K.; Hiraoka, M.; Inamoto, T. A case of allergic reaction to surgical metal clips inserted for postoperative boost irradiation in a patient undergoing breast conserving therapy. Breast Cancer 2001, 8, 90-92.
    • (2001) Breast Cancer , vol.8 , pp. 90-92
    • Tamai, K.1    Mitsumori, M.2    Fujishiro, S.3    Kokubo, M.4    Ooya, N.5    Nagata, Y.6    Sasai, K.7    Hiraoka, M.8    Inamoto, T.9
  • 32
    • 33748454877 scopus 로고    scopus 로고
    • Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema, and T-cell hyper responsiveness in vitro: Case report and review of the literature
    • Thomas, P.; Bandl, W.D.; Maier, S.; Summer, B.; Przybilla, B. Hypersensitivity to titanium osteosynthesis with impaired fracture healing, eczema, and T-cell hyper responsiveness in vitro: Case report and review of the literature. Contact Dermat. 2006, 55, 199-202.
    • (2006) Contact Dermat , vol.55 , pp. 199-202
    • Thomas, P.1    Bandl, W.D.2    Maier, S.3    Summer, B.4    Przybilla, B.5
  • 33
    • 0030468850 scopus 로고    scopus 로고
    • Retention of asymptomatic bone plates used for orthognathic surgery and facial fractures
    • Haug, R.H. Retention of asymptomatic bone plates used for orthognathic surgery and facial fractures. J. Oral Maxillofac. Surg. 1996, 54, 611-617.
    • (1996) J. Oral Maxillofac. Surg , vol.54 , pp. 611-617
    • Haug, R.H.1
  • 34
    • 47149090640 scopus 로고    scopus 로고
    • Clinical relevance of allergological tests in total hip joint replacement.
    • Willmann, G., Zweymüller, K., Eds.; Thieme: New York, NY, USA
    • Schramm, M.; Pitto, R.P. Clinical relevance of allergological tests in total hip joint replacement. In Bioceramics in Hip Joint Replacement; Willmann, G., Zweymüller, K., Eds.; Thieme: New York, NY, USA, 2000; pp. 101-106.
    • (2000) Bioceramics in Hip Joint Replacement , pp. 101-106
    • Schramm, M.1    Pitto, R.P.2
  • 36
    • 0025390282 scopus 로고
    • Tissue reaction involving an intraoral skin graft and CP titanium abutments: A clinical report
    • Mitchell, D.L.; Synnott, S.A.; van Dercreek, J.A. Tissue reaction involving an intraoral skin graft and CP titanium abutments: A clinical report. Int. J. Oral Maxillofac. Implants 1990, 5, 79-84.
    • (1990) Int. J. Oral Maxillofac. Implants , vol.5 , pp. 79-84
    • Mitchell, D.L.1    Synnott, S.A.2    van Dercreek, J.A.3
  • 37
    • 34247877576 scopus 로고    scopus 로고
    • Implant failure due to titanium hypersensitivity/allergy?-Report of a case
    • Du Preez, L.A.; Bütow, K.W.; Swart, T.J. Implant failure due to titanium hypersensitivity/allergy?-Report of a case. SADJ 2007, 62, 22-25.
    • (2007) SADJ , vol.62 , pp. 22-25
    • Du Preez, L.A.1    Bütow, K.W.2    Swart, T.J.3
  • 38
    • 34047211736 scopus 로고    scopus 로고
    • Hypersensitivity to titanium: Clinical and laboratory evidence
    • Müller, K.; Valentine-Thon, E. Hypersensitivity to titanium: Clinical and laboratory evidence. Neuro. Endocrinol. Lett. 2006, 27, 31-35.
    • (2006) Neuro. Endocrinol. Lett , vol.27 , pp. 31-35
    • Müller, K.1    Valentine-Thon, E.2
  • 39
    • 84883377508 scopus 로고    scopus 로고
    • Allergy related to dental implant and its clinical significance
    • Chaturvedi, T.P. Allergy related to dental implant and its clinical significance. Clin. Cosmet. Investig. Dent. 2013, 5, 57-61.
    • (2013) Clin. Cosmet. Investig. Dent , vol.5 , pp. 57-61
    • Chaturvedi, T.P.1
  • 40
    • 0030236468 scopus 로고    scopus 로고
    • An analysis and management of fractured implants: A clinical report
    • Balshi, T.H. An analysis and management of fractured implants: A clinical report. Int. J. Oral Maxillofac. Implants 1996, 11, 660-666.
    • (1996) Int. J. Oral Maxillofac. Implants , vol.11 , pp. 660-666
    • Balshi, T.H.1
  • 42
    • 0027793057 scopus 로고
    • Oral implant treatment in posterior partially edentulous jaws: A 5-year follow-up report
    • Jemt, T.; Lekholm, U. Oral implant treatment in posterior partially edentulous jaws: A 5-year follow-up report. Int. J. Oral Maxillofac. Implants 1993, 8, 635-640.
    • (1993) Int. J. Oral Maxillofac. Implants , vol.8 , pp. 635-640
    • Jemt, T.1    Lekholm, U.2
  • 43
    • 0025471133 scopus 로고
    • The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered
    • Zarb, G.; Schmitt, A. The longitudinal clinical effectiveness of osseointegrated dental implants: The Toronto study. Part III: Problems and complications encountered. J. Prosthet. Dent. 1990, 64, 185-194.
    • (1990) J. Prosthet. Dent , vol.64 , pp. 185-194
    • Zarb, G.1    Schmitt, A.2
  • 44
    • 0031989688 scopus 로고    scopus 로고
    • Hollow implants retreived for fracture: A light and scanning electron microscope analysis of 4 cases
    • Piattelli, A.; Scarano, A.; Piattelli, M.; Vaia, E.; Matarasso, S. Hollow implants retreived for fracture: A light and scanning electron microscope analysis of 4 cases. J. Periodontol. 1998, 69, 185-189.
    • (1998) J. Periodontol , vol.69 , pp. 185-189
    • Piattelli, A.1    Scarano, A.2    Piattelli, M.3    Vaia, E.4    Matarasso, S.5
  • 46
    • 0034268455 scopus 로고    scopus 로고
    • Analysis of incidence and associated factors with fractured implants: A retrospective study
    • Eckert, S.E.; Meraw, S.J.; Cal, E.; Ow, R.K. Analysis of incidence and associated factors with fractured implants: A retrospective study. Int. J. Oral Maxillofac. Implants 2000, 15, 662-667.
    • (2000) Int. J. Oral Maxillofac. Implants , vol.15 , pp. 662-667
    • Eckert, S.E.1    Meraw, S.J.2    Cal, E.3    Ow, R.K.4
  • 47
    • 0036043045 scopus 로고    scopus 로고
    • Fracture of dental implants: Literature review and report of a case
    • Green, N.T.; Machtei, E.E.; Horwitz, J.; Peled, M. Fracture of dental implants: Literature review and report of a case. Implant Dent. 2002, 11, 137-143.
    • (2002) Implant Dent , vol.11 , pp. 137-143
    • Green, N.T.1    Machtei, E.E.2    Horwitz, J.3    Peled, M.4
  • 48
    • 0026829920 scopus 로고
    • Theoretical analysis of the fatigue life of fixture screws in oseeointegrated dental implants
    • Patterson, E.A.; Johns, R.B. Theoretical analysis of the fatigue life of fixture screws in oseeointegrated dental implants. Int. J. Oral Maxillofac. Implants 1992, 7, 26-34.
    • (1992) Int. J. Oral Maxillofac. Implants , vol.7 , pp. 26-34
    • Patterson, E.A.1    Johns, R.B.2
  • 50
    • 35548966304 scopus 로고    scopus 로고
    • A review of the aetiology and management of fractured dental implants and a case report
    • Virdee, P.; Bishop, K. A review of the aetiology and management of fractured dental implants and a case report. Br. Dent. J. 2007, 203, 461-466.
    • (2007) Br. Dent. J , vol.203 , pp. 461-466
    • Virdee, P.1    Bishop, K.2
  • 51
    • 0036010384 scopus 로고    scopus 로고
    • Fracture mechanisms of retrieved titanium screw thread in dental implant
    • Yokoyama, K.; Ichikawa, T.; Murakami, H.; Miyamoto, Y.; Asaoka, K. Fracture mechanisms of retrieved titanium screw thread in dental implant. Biomaterials 2002, 23, 2459-2465.
    • (2002) Biomaterials , vol.23 , pp. 2459-2465
    • Yokoyama, K.1    Ichikawa, T.2    Murakami, H.3    Miyamoto, Y.4    Asaoka, K.5
  • 52
    • 0032240722 scopus 로고    scopus 로고
    • Current status of ceramic coatings for dental implants
    • Lacefield, W.R. Current status of ceramic coatings for dental implants. Implant Dent. 1998, 7, 315-322.
    • (1998) Implant Dent , vol.7 , pp. 315-322
    • Lacefield, W.R.1
  • 53
    • 0000840939 scopus 로고
    • State of the art: Hydroxylapatite coatings for dental implants
    • De Groot, K.; Wolke, J.C.G.; Jansen, J.A. State of the art: Hydroxylapatite coatings for dental implants. J. Oral Implant. 1994, 20, 232-234.
    • (1994) J. Oral Implant , vol.20 , pp. 232-234
    • De Groot, K.1    Wolke, J.C.G.2    Jansen, J.A.3
  • 54
    • 0034585724 scopus 로고    scopus 로고
    • Periodontal-type measurements associated with hydroxyapatite-coated and non-HA-coated implants: Uncovering to 36 months
    • Morris, H.F.; Ochi, S.; Spray, J.R.; Olson, J.W. Periodontal-type measurements associated with hydroxyapatite-coated and non-HA-coated implants: Uncovering to 36 months. Ann. Periodontol. 2000, 5, 56-67.
    • (2000) Ann. Periodontol , vol.5 , pp. 56-67
    • Morris, H.F.1    Ochi, S.2    Spray, J.R.3    Olson, J.W.4
  • 55
    • 0345169050 scopus 로고    scopus 로고
    • Osteointegration of biomimetic apatite coating applied onto dense and porous metal implants in femurs of goats
    • Barrere, F.; van der Valk, C.M.; Meijer, G.; Dalmeijer, R.A.; de Groot, K.; Layrolle, P. Osteointegration of biomimetic apatite coating applied onto dense and porous metal implants in femurs of goats. J. Biomed. Mater. Res. 2003, 67, 655-665.
    • (2003) J. Biomed. Mater. Res , vol.67 , pp. 655-665
    • Barrere, F.1    van der Valk, C.M.2    Meijer, G.3    Dalmeijer, R.A.4    de Groot, K.5    Layrolle, P.6
  • 56
    • 34248356846 scopus 로고    scopus 로고
    • Surface treatments of titanium dental implants for rapid osseointegration
    • Le Guéhennec, L.; Soueidan, A.; Layrolle, P.; Amouriq, Y. Surface treatments of titanium dental implants for rapid osseointegration. J. Dent. Mater. 2007, 23, 844-854.
    • (2007) J. Dent. Mater , vol.23 , pp. 844-854
    • Le Guéhennec, L.1    Soueidan, A.2    Layrolle, P.3    Amouriq, Y.4
  • 57
    • 0030144537 scopus 로고    scopus 로고
    • Eight-year clinical retrospective study of titanium plasma-sprayed and hydroxyapatite-coated cylinder implants
    • Wheeler, S. Eight-year clinical retrospective study of titanium plasma-sprayed and hydroxyapatite-coated cylinder implants. Int. J. Oral Maxillofac. Implants 1996, 11, 340-350.
    • (1996) Int. J. Oral Maxillofac. Implants , vol.11 , pp. 340-350
    • Wheeler, S.1
  • 58
    • 0032824351 scopus 로고    scopus 로고
    • Biomechanical and morphometric analysis of hydroxyapatite-coated implants with varying crystallinity
    • Chang, Y.-L.; Lew, D.; Park, J.B.; Keller, J.C. Biomechanical and morphometric analysis of hydroxyapatite-coated implants with varying crystallinity. J. Oral Maxillofac. Surg. 1999, 57, 1096-1108.
    • (1999) J. Oral Maxillofac. Surg , vol.57 , pp. 1096-1108
    • Chang, Y.-L.1    Lew, D.2    Park, J.B.3    Keller, J.C.4
  • 59
    • 0035318261 scopus 로고    scopus 로고
    • A comparison of hydroxyapatite coated implant retained fixed and removable mandibular prostheses over 4 to 6 years
    • Tinsley, D.; Watson, C.; Russell, J. A comparison of hydroxyapatite coated implant retained fixed and removable mandibular prostheses over 4 to 6 years. Clin. Oral Implants Res. 2001, 12, 159-166.
    • (2001) Clin. Oral Implants Res , vol.12 , pp. 159-166
    • Tinsley, D.1    Watson, C.2    Russell, J.3
  • 60
    • 42149131820 scopus 로고    scopus 로고
    • Ceramic abutments and ceramic oral implants. An update.
    • Kohal, R.J.; Att, W.; Bächle, M.; Butz, F. Ceramic abutments and ceramic oral implants. An update. Periodontol. 2000 2008, 47, 224-243.
    • (2008) Periodontol. 2000 , vol.47 , pp. 224-243
    • Kohal, R.J.1    Att, W.2    Bächle, M.3    Butz, F.4
  • 61
    • 0037583080 scopus 로고    scopus 로고
    • Oxide bioceramics: Inert ceramic materials in medicine and dentistry.
    • 1st ed.; Chapman & Hall: London, UK
    • Black, J.; Hastings, G. Oxide bioceramics: Inert ceramic materials in medicine and dentistry. In Handbook of Biomaterial Properties, 1st ed.; Chapman & Hall: London, UK, 1998; p. 340.
    • (1998) Handbook of Biomaterial Properties , pp. 340
    • Black, J.1    Hastings, G.2
  • 62
    • 38349192796 scopus 로고    scopus 로고
    • State of the art of zirconia for dental applications
    • Denry, I.; Kelly, J.R. State of the art of zirconia for dental applications. Dent. Mater. 2008, 24, 299-307.
    • (2008) Dent. Mater , vol.24 , pp. 299-307
    • Denry, I.1    Kelly, J.R.2
  • 63
    • 0032917811 scopus 로고    scopus 로고
    • Zirconia as a ceramic biomaterial
    • Piconi, C.; Maccauro, G. Zirconia as a ceramic biomaterial. Biomaterials 1999, 20, 1-25.
    • (1999) Biomaterials , vol.20 , pp. 1-25
    • Piconi, C.1    Maccauro, G.2
  • 64
    • 33748373989 scopus 로고    scopus 로고
    • Zirconia-implant supported all-ceramic crowns withstand long-term load: A pilot investigation
    • Kohal, R.J.; Klaus, G.; Strub, J.R. Zirconia-implant supported all-ceramic crowns withstand long-term load: A pilot investigation. Clin. Oral Implants Res. 2006, 17, 565-571.
    • (2006) Clin. Oral Implants Res , vol.17 , pp. 565-571
    • Kohal, R.J.1    Klaus, G.2    Strub, J.R.3
  • 65
    • 79960205358 scopus 로고    scopus 로고
    • The effects of cyclic loading and preparation on the fracture strength of zirconium-dioxide implants: An in vitro investigation
    • Kohal, R.J.; Wolkewitz, M.; Tsakona, A. The effects of cyclic loading and preparation on the fracture strength of zirconium-dioxide implants: An in vitro investigation. Clin. Oral Implants Res. 2011, 22, 808-814.
    • (2011) Clin. Oral Implants Res , vol.22 , pp. 808-814
    • Kohal, R.J.1    Wolkewitz, M.2    Tsakona, A.3
  • 67
    • 70449392380 scopus 로고    scopus 로고
    • Stability of prototype two piece zirconia and titanium implants after artificial aging: An in vitro pilot study
    • Kohal, R.J.; Finke, H.C.; Klaus, G. Stability of prototype two piece zirconia and titanium implants after artificial aging: An in vitro pilot study. Clin. Implant Dent. Relat. Res. 2009, 11, 323-329.
    • (2009) Clin. Implant Dent. Relat. Res , vol.11 , pp. 323-329
    • Kohal, R.J.1    Finke, H.C.2    Klaus, G.3
  • 70
    • 0029237462 scopus 로고
    • Environmental degradation of zirconia ceramics
    • Lawson, S. Environmental degradation of zirconia ceramics. J. Eur. Ceram. Soc. 1995, 15, 485-502.
    • (1995) J. Eur. Ceram. Soc , vol.15 , pp. 485-502
    • Lawson, S.1
  • 71
    • 26844583254 scopus 로고    scopus 로고
    • What future for zirconia as a biomaterial?
    • Chevalier, J. What future for zirconia as a biomaterial? Biomaterials 2006, 27, 535-543.
    • (2006) Biomaterials , vol.27 , pp. 535-543
    • Chevalier, J.1
  • 72
    • 0021588035 scopus 로고
    • Ageing behaviour of Y-TZP.
    • Claussen, N., Ruhle, M., Heuer, A.H., Eds.; The American Ceramic Society, Inc.: Columbus, OH, USA
    • Watanabe, M.; Iio, S.; Fukuura, I. Ageing behaviour of Y-TZP. In Science and Technology of Zirconia II, Advances in Ceramics; Claussen, N., Ruhle, M., Heuer, A.H., Eds.; The American Ceramic Society, Inc.: Columbus, OH, USA, 1984; Volume 12, pp. 391-398.
    • (1984) Science and Technology of Zirconia II, Advances in Ceramics , vol.12 , pp. 391-398
    • Watanabe, M.1    Iio, S.2    Fukuura, I.3
  • 73
    • 33947313524 scopus 로고    scopus 로고
    • ZrO2 three-unit fixed partial dentures: Comparison of failure load before and after exposure to a mastication simulator
    • Att, W.; Grigoriadou, M.; Strub, J.R. ZrO2 three-unit fixed partial dentures: Comparison of failure load before and after exposure to a mastication simulator. J. Oral Rehabil. 2007, 34, 282-290.
    • (2007) J. Oral Rehabil , vol.34 , pp. 282-290
    • Att, W.1    Grigoriadou, M.2    Strub, J.R.3
  • 74
    • 84863878945 scopus 로고    scopus 로고
    • Influence of low temperature environmental exposure on the mechanical properties and structural stability of dental zirconia
    • Alghazzawi, T.F.; Lemons, J.; Liu, P.R.; Essig, M.E.; Bartolucci, A.A.; Janowski, G.M. Influence of low temperature environmental exposure on the mechanical properties and structural stability of dental zirconia. J. Prosthodont. 2012, 21, 363-369.
    • (2012) J. Prosthodont , vol.21 , pp. 363-369
    • Alghazzawi, T.F.1    Lemons, J.2    Liu, P.R.3    Essig, M.E.4    Bartolucci, A.A.5    Janowski, G.M.6
  • 75
    • 84925081623 scopus 로고    scopus 로고
    • The combined effect of alumina and silica co-doping on the ageing resistance of 3Y-TZP bioceramics
    • Samodurova, A.; Andraž, K.; Swain, M.V.; Tomaž, K. The combined effect of alumina and silica co-doping on the ageing resistance of 3Y-TZP bioceramics. Acta Biomater. 2014, 11, 477-487.
    • (2014) Acta Biomater , vol.11 , pp. 477-487
    • Samodurova, A.1    Andraž, K.2    Swain, M.V.3    Tomaž, K.4
  • 78
    • 84875627895 scopus 로고    scopus 로고
    • Fractured Zirconia implants and related implant designs: Scanning electron microscopy analysis
    • Osman, R.B.; Ma, S.; Duncan, W.; de Silva, R.K.; Siddiqi, A.; Swain, M.V. Fractured Zirconia implants and related implant designs: Scanning electron microscopy analysis. Clin. Oral Implants Res. 2013, 24, 592-597.
    • (2013) Clin. Oral Implants Res , vol.24 , pp. 592-597
    • Osman, R.B.1    Ma, S.2    Duncan, W.3    de Silva, R.K.4    Siddiqi, A.5    Swain, M.V.6
  • 79
    • 84889880897 scopus 로고    scopus 로고
    • Fatigue of dental ceramics
    • Zhang, Y.; Sailer, I.; Lawn, B.R. Fatigue of dental ceramics. J. Dent. 2013, 41, 1135-1147.
    • (2013) J. Dent , vol.41 , pp. 1135-1147
    • Zhang, Y.1    Sailer, I.2    Lawn, B.R.3
  • 82
    • 0030244480 scopus 로고    scopus 로고
    • Effect of heat-treatment on grain size, phase assemblage, and mechanical properties of 3 mol % Y-TZP
    • Ruiz, L.; Readey, M.J. Effect of heat-treatment on grain size, phase assemblage, and mechanical properties of 3 mol % Y-TZP. J. Am. Ceram. Soc. 1996, 79, 2331-2340.
    • (1996) J. Am. Ceram. Soc , vol.79 , pp. 2331-2340
    • Ruiz, L.1    Readey, M.J.2
  • 83
    • 0020245022 scopus 로고
    • Stability of tetragonal ZrO2 particles in ceramic matrices
    • Heuer, A.H.; Claussen, N.; Kriven, W.M.; Ruhle, M. Stability of tetragonal ZrO2 particles in ceramic matrices. J. Am. Ceram. Soc. 1982, 65, 642-650.
    • (1982) J. Am. Ceram. Soc , vol.65 , pp. 642-650
    • Heuer, A.H.1    Claussen, N.2    Kriven, W.M.3    Ruhle, M.4
  • 84
    • 0030105465 scopus 로고    scopus 로고
    • Fracture toughness of nanocrystalline ZrO2-3 mol % Y2O3 determined by Vickers indentation
    • Cottom, B.A.; Mayo, M.J. Fracture toughness of nanocrystalline ZrO2-3 mol % Y2O3 determined by Vickers indentation. Scr. Mater. 1996, 34, 809-814.
    • (1996) Scr. Mater , vol.34 , pp. 809-814
    • Cottom, B.A.1    Mayo, M.J.2
  • 85
    • 0242468093 scopus 로고    scopus 로고
    • Net-shaping of ceramic components by direct ceramic machining
    • Filser, F.; Kocher, P.; Gauckler, L.J. Net-shaping of ceramic components by direct ceramic machining. Assembly Autom. 2003, 23, 382-390.
    • (2003) Assembly Autom , vol.23 , pp. 382-390
    • Filser, F.1    Kocher, P.2    Gauckler, L.J.3
  • 86
    • 0035965071 scopus 로고    scopus 로고
    • The role of trace additions of alumina to yttria-tetragonal zirconia polycrystal (Y-TZP)
    • Ross, I.M.; Rainforth, W.M.; McComb, D.W.; Scott, A.J.; Brydson, R. The role of trace additions of alumina to yttria-tetragonal zirconia polycrystal (Y-TZP). Scr. Mater. 2001, 45, 653-660.
    • (2001) Scr. Mater , vol.45 , pp. 653-660
    • Ross, I.M.1    Rainforth, W.M.2    McComb, D.W.3    Scott, A.J.4    Brydson, R.5
  • 87
    • 0031104066 scopus 로고    scopus 로고
    • Influence of a small amount of Al2O3 addition on the transformation of Y2O3-partially stabilized ZrO2 during annealing
    • Li, L.F.; Watanabe, R. Influence of a small amount of Al2O3 addition on the transformation of Y2O3-partially stabilized ZrO2 during annealing. J. Mater. Sci. 1997, 32, 1149-1153.
    • (1997) J. Mater. Sci , vol.32 , pp. 1149-1153
    • Li, L.F.1    Watanabe, R.2
  • 88
    • 0026115091 scopus 로고
    • Effect of alumina addition on the tetragonal-to-monoclinic phase transformation in zirconia-3 mol % yttria
    • Tsubakino, H.; Nozato, R.; Hamamoto, M. Effect of alumina addition on the tetragonal-to-monoclinic phase transformation in zirconia-3 mol % yttria. J. Am. Ceram. Soc. 1991, 74, 440-443.
    • (1991) J. Am. Ceram. Soc , vol.74 , pp. 440-443
    • Tsubakino, H.1    Nozato, R.2    Hamamoto, M.3
  • 89
    • 0345868765 scopus 로고    scopus 로고
    • Influence of grinding, sandblasting, polishing and heat treatment on the flexural strength of a glass-infiltrated alumina-reinforced dental ceramic
    • Guazzato, M.; Albakry, M.; Quach, L.; Swain, M.V. Influence of grinding, sandblasting, polishing and heat treatment on the flexural strength of a glass-infiltrated alumina-reinforced dental ceramic. Biomaterials 2004, 25, 2153-2160.
    • (2004) Biomaterials , vol.25 , pp. 2153-2160
    • Guazzato, M.1    Albakry, M.2    Quach, L.3    Swain, M.V.4
  • 90
    • 65349121531 scopus 로고    scopus 로고
    • Microstructure of alumina-and alumina/zirconia-glass infiltrated dental ceramics
    • Guazzato, M.; Albakry, M.; Swain, M.V.; Ringer, S.P. Microstructure of alumina-and alumina/zirconia-glass infiltrated dental ceramics. Bioceramics 2003, 15, 879-882.
    • (2003) Bioceramics , vol.15 , pp. 879-882
    • Guazzato, M.1    Albakry, M.2    Swain, M.V.3    Ringer, S.P.4
  • 91
    • 1842783267 scopus 로고    scopus 로고
    • Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics.
    • Guazzato, M.; Albakry, M.; Ringer, S.P.; Swain, M.V. Strength, fracture toughness and microstructure of a selection of all-ceramic materials. Part II. Zirconia-based dental ceramics. Dent. Mater. 2004, 20, 449-456.
    • (2004) Dent. Mater , vol.20 , pp. 449-456
    • Guazzato, M.1    Albakry, M.2    Ringer, S.P.3    Swain, M.V.4
  • 92
    • 0034244721 scopus 로고    scopus 로고
    • Alumina toughened zirconia made by room temperature extrusion of ceramic pastes
    • Pabst, W.; Havrda, E.; Gregorová, E.; Krčmová, B. Alumina toughened zirconia made by room temperature extrusion of ceramic pastes. J. Am. Ceram. Soc. 2000, 44, 41-47.
    • (2000) J. Am. Ceram. Soc , vol.44 , pp. 41-47
    • Pabst, W.1    Havrda, E.2    Gregorová, E.3    Krčmová, B.4
  • 93
    • 0027613970 scopus 로고
    • Interface histology of unloaded and early loaded partially stabilized zirconia endosseous implant in initial bone healing
    • Akagawa, Y.; Ichikawa, Y.; Nikai, H.; Tsuru, H. Interface histology of unloaded and early loaded partially stabilized zirconia endosseous implant in initial bone healing. J. Prosthet. Dent. 1993, 69, 599-604.
    • (1993) J. Prosthet. Dent , vol.69 , pp. 599-604
    • Akagawa, Y.1    Ichikawa, Y.2    Nikai, H.3    Tsuru, H.4
  • 94
    • 0032199149 scopus 로고    scopus 로고
    • Comparison between freestanding and tooth-connected partially stabilized zirconia implants after two years function in monkeys: A clinical and histologic study
    • Akagawa, Y.; Hosok, R.; Sato, Y.; Kamayama, K. Comparison between freestanding and tooth-connected partially stabilized zirconia implants after two years function in monkeys: A clinical and histologic study. J. Prosthet. Dent. 1998, 80, 551-558.
    • (1998) J. Prosthet. Dent , vol.80 , pp. 551-558
    • Akagawa, Y.1    Hosok, R.2    Sato, Y.3    Kamayama, K.4
  • 95
    • 7044246252 scopus 로고    scopus 로고
    • Loaded custom-made zirconia and titanium implants show similar osseointegration: An animal experiment
    • Kohal, R.J.; Weng, D.; Bächle, M.; Strub, J.R. Loaded custom-made zirconia and titanium implants show similar osseointegration: An animal experiment. J. Periodontol. 2004, 75, 1262-1268.
    • (2004) J. Periodontol , vol.75 , pp. 1262-1268
    • Kohal, R.J.1    Weng, D.2    Bächle, M.3    Strub, J.R.4
  • 97
    • 0037809315 scopus 로고    scopus 로고
    • Bone response to zirconia ceramic implants: An experimental study in rabbits
    • Scarano, A.; Di Carlo, F.; Quaranta, M.; Piattelli, A. Bone response to zirconia ceramic implants: An experimental study in rabbits. J. Oral Implantol. 2003, 29, 8-12.
    • (2003) J. Oral Implantol , vol.29 , pp. 8-12
    • Scarano, A.1    Di Carlo, F.2    Quaranta, M.3    Piattelli, A.4
  • 100
    • 84857051087 scopus 로고    scopus 로고
    • In vivo performance of zirconia and titanium implants: A histomorphometric study in mini pig maxillae
    • Gahlert, M.; Roehling, S.; Sprecher, C.M.; Kniha, H.; Milz, S.; Bormann, K. In vivo performance of zirconia and titanium implants: A histomorphometric study in mini pig maxillae. Clin. Oral Implants Res. 2012, 23, 281-286.
    • (2012) Clin. Oral Implants Res , vol.23 , pp. 281-286
    • Gahlert, M.1    Roehling, S.2    Sprecher, C.M.3    Kniha, H.4    Milz, S.5    Bormann, K.6
  • 102
    • 20744457194 scopus 로고    scopus 로고
    • Bone tissue response to surface modified zirconia implants: A histomorphometric and removal torque study in the rabbit
    • Sennerby, L.; Dasmah, A.; Larsson, B.; Iverhed, M. Bone tissue response to surface modified zirconia implants: A histomorphometric and removal torque study in the rabbit. Clin. Implant Dent. Relat. Res. 2005, 7, S13-S20.
    • (2005) Clin. Implant Dent. Relat. Res , vol.7 , pp. S13-S20
    • Sennerby, L.1    Dasmah, A.2    Larsson, B.3    Iverhed, M.4
  • 104
    • 34548663648 scopus 로고    scopus 로고
    • Biomechanical and histomorphometric comparison between zirconia implants with varying surface textures and a titanium implant in the maxilla of miniature pigs
    • Gahlert, M.; Gudehus, T.; Eichhorn, S.; Steinhauser, E.; Kniha, H.; Erhardt, W. Biomechanical and histomorphometric comparison between zirconia implants with varying surface textures and a titanium implant in the maxilla of miniature pigs. Clin. Oral Implants Res. 2007, 18, 662-668.
    • (2007) Clin. Oral Implants Res , vol.18 , pp. 662-668
    • Gahlert, M.1    Gudehus, T.2    Eichhorn, S.3    Steinhauser, E.4    Kniha, H.5    Erhardt, W.6
  • 105
    • 77955727742 scopus 로고    scopus 로고
    • Mechanical anchorage and peri-implant bone formation of surface-modified zirconia in minipigs
    • Schliephake, H.; Hefti, T.; Schlottig, F.; Gédet, P.; Staedt, H. Mechanical anchorage and peri-implant bone formation of surface-modified zirconia in minipigs. J. Clin. Periodontol. 2010, 37, 818-828.
    • (2010) J. Clin. Periodontol , vol.37 , pp. 818-828
    • Schliephake, H.1    Hefti, T.2    Schlottig, F.3    Gédet, P.4    Staedt, H.5
  • 106
    • 33846187197 scopus 로고    scopus 로고
    • Behavior of CAL72 osteoblast-like cells cultured on zirconia ceramics with different surface topographies
    • Bächle, M.; Butz, F.; Hübner, U.; Bakalinis, E.; Kohal, R.J. Behavior of CAL72 osteoblast-like cells cultured on zirconia ceramics with different surface topographies. Clin. Oral Implants Res. 2007, 18, 53-59.
    • (2007) Clin. Oral Implants Res , vol.18 , pp. 53-59
    • Bächle, M.1    Butz, F.2    Hübner, U.3    Bakalinis, E.4    Kohal, R.J.5
  • 108
    • 21344450518 scopus 로고    scopus 로고
    • Osteoblast cell adhesion on a laser modified zirconia based bioceramic
    • Hao, L.; Lawrence, J.; Chian, K.S. Osteoblast cell adhesion on a laser modified zirconia based bioceramic. J. Mater. Sci. Mater. Med. 2005, 16, 719-726.
    • (2005) J. Mater. Sci. Mater. Med , vol.16 , pp. 719-726
    • Hao, L.1    Lawrence, J.2    Chian, K.S.3
  • 109
    • 84920901857 scopus 로고    scopus 로고
    • Influence of ultraviolet photofunctionalization on the surface characteristics of zirconia-based dental implant materials
    • Tuna, T.; Wein, M.; Swain, M.; Fischer, J.; Att, W. Influence of ultraviolet photofunctionalization on the surface characteristics of zirconia-based dental implant materials. Dent. Mater. 2015, 31, e14-e24.
    • (2015) Dent. Mater , vol.31 , pp. e14-e24
    • Tuna, T.1    Wein, M.2    Swain, M.3    Fischer, J.4    Att, W.5
  • 114
    • 84875615159 scopus 로고    scopus 로고
    • Peri-implant bone formation and surface characteristics of rough surface zirconia implants manufactured by powder injection molding technique in rabbit tibiae
    • Park, Y.S.; Chung, S.H.; Shon, W.J. Peri-implant bone formation and surface characteristics of rough surface zirconia implants manufactured by powder injection molding technique in rabbit tibiae. Clin. Oral Implants Res. 2013, 24, 586-591.
    • (2013) Clin. Oral Implants Res , vol.24 , pp. 586-591
    • Park, Y.S.1    Chung, S.H.2    Shon, W.J.3
  • 115
    • 84902581453 scopus 로고    scopus 로고
    • Comparison of clinical performance of zirconia implants and titanium implants in animal models: A systematic review
    • Manzano, G.; Herrero, L.R.; Montero, J. Comparison of clinical performance of zirconia implants and titanium implants in animal models: A systematic review. Int. J. Oral Maxillofac. Implants 2014, 29, 311-320.
    • (2014) Int. J. Oral Maxillofac. Implants , vol.29 , pp. 311-320
    • Manzano, G.1    Herrero, L.R.2    Montero, J.3
  • 116
    • 85018652190 scopus 로고    scopus 로고
    • Quality of the peri-implant soft tissue attachment of zirconia implants-abutments
    • Mellinghoff, J. Quality of the peri-implant soft tissue attachment of zirconia implants-abutments. Z. Zahnärztl. Implants 2010, 26, 62-71.
    • (2010) Z. Zahnärztl. Implants , vol.26 , pp. 62-71
    • Mellinghoff, J.1
  • 117
    • 67650708735 scopus 로고    scopus 로고
    • Attachment and growth behavior of human gingival fibroblasts on titanium and zirconia ceramic surfaces
    • Pae, A.; Lee, H.; Kim, H.S.; Kwon, Y.D.; Woo, Y.H. Attachment and growth behavior of human gingival fibroblasts on titanium and zirconia ceramic surfaces. Biomed. Mater. 2009, 2, 025005-025012.
    • (2009) Biomed. Mater , vol.2 , pp. 025005-025012
    • Pae, A.1    Lee, H.2    Kim, H.S.3    Kwon, Y.D.4    Woo, Y.H.5
  • 119
    • 1642312001 scopus 로고    scopus 로고
    • Bacterial adhesion on commercially pure titanium and zirconium oxide discs: An in vivo human study
    • Scarano, A.; Piattelli, M.; Caputi, S.; Favero, G.A.; Piattelli, A. Bacterial adhesion on commercially pure titanium and zirconium oxide discs: An in vivo human study. J. Periodontol. 2004, 75, 292-296.
    • (2004) J. Periodontol , vol.75 , pp. 292-296
    • Scarano, A.1    Piattelli, M.2    Caputi, S.3    Favero, G.A.4    Piattelli, A.5
  • 120
    • 33646188160 scopus 로고    scopus 로고
    • Inflammatory infiltrate, microvessel density, nitric oxide synthase expression, vascular endothelial growth factor expression, and proliferative activity in peri-implant soft tissues around titanium and zirconium oxide healing caps
    • Degidi, M.; Artese, L.; Scarano, A.; Perrotti, V.; Gehrke, P.; Piattelli, A. Inflammatory infiltrate, microvessel density, nitric oxide synthase expression, vascular endothelial growth factor expression, and proliferative activity in peri-implant soft tissues around titanium and zirconium oxide healing caps. J. Periodontol. 2006, 77, 73-80.
    • (2006) J. Periodontol , vol.77 , pp. 73-80
    • Degidi, M.1    Artese, L.2    Scarano, A.3    Perrotti, V.4    Gehrke, P.5    Piattelli, A.6
  • 122
    • 44949111488 scopus 로고    scopus 로고
    • The mucosal barrier at implant abutments of different materials
    • Welander, M.; Abrahamsson, I.; Berglundh, T. The mucosal barrier at implant abutments of different materials. Clin. Oral Implants Res. 2008, 19, 635-641.
    • (2008) Clin. Oral Implants Res , vol.19 , pp. 635-641
    • Welander, M.1    Abrahamsson, I.2    Berglundh, T.3
  • 123
    • 47149095548 scopus 로고    scopus 로고
    • Adsorption of salivary and serum proteins, and bacterial adherence on titanium and zirconia ceramic surfaces
    • Lima, E.M.C.X.; Koo, H.; Vacca-Smith, A.M.; Rosalen, P.L.; Del Bel Cury, A.A. Adsorption of salivary and serum proteins, and bacterial adherence on titanium and zirconia ceramic surfaces. Clin. Oral Implants Res. 2008, 19, 780-785.
    • (2008) Clin. Oral Implants Res , vol.19 , pp. 780-785
    • Lima, E.M.C.X.1    Koo, H.2    Vacca-Smith, A.M.3    Rosalen, P.L.4    Del Bel Cury, A.A.5
  • 127
    • 1842610851 scopus 로고    scopus 로고
    • A zirconia implant-crown system: A case report
    • Kohal, R.J.; Klaus, G. A zirconia implant-crown system: A case report. Int. J. Periodontics Restor. 2004, 24, 147-153.
    • (2004) Int. J. Periodontics Restor , vol.24 , pp. 147-153
    • Kohal, R.J.1    Klaus, G.2
  • 128
    • 63249084368 scopus 로고    scopus 로고
    • Ovoid zirconia implants: Anatomic design for premolar replacement
    • Oliva, J.; Oliva, X.; Oliva, J.D. Ovoid zirconia implants: Anatomic design for premolar replacement. Int. J. Periodontics Restor. 2008, 28, 609-615.
    • (2008) Int. J. Periodontics Restor , vol.28 , pp. 609-615
    • Oliva, J.1    Oliva, X.2    Oliva, J.D.3
  • 129
    • 68949220110 scopus 로고    scopus 로고
    • Zirconia implants and all ceramic restorations for esthetic replacement of the maxillary central incisors
    • Oliva, J.; Oliva, X.; Oliva, J.D. Zirconia implants and all ceramic restorations for esthetic replacement of the maxillary central incisors. Eur. J. Esthet. Dent. 2008, 3, 174-185.
    • (2008) Eur. J. Esthet. Dent , vol.3 , pp. 174-185
    • Oliva, J.1    Oliva, X.2    Oliva, J.D.3
  • 130
    • 84874699778 scopus 로고    scopus 로고
    • Replacement of congenitally missing maxillary permanent canine with a zirconium oxide dental implant and crown. A case report from an ongoing clinical study.
    • Oliva, X.; Oliva, J.; Oliva, J.D. Replacement of congenitally missing maxillary permanent canine with a zirconium oxide dental implant and crown. A case report from an ongoing clinical study. Oral Surg. 2008, 1, 140-144.
    • (2008) Oral Surg , vol.1 , pp. 140-144
    • Oliva, X.1    Oliva, J.2    Oliva, J.D.3
  • 131
    • 40249098654 scopus 로고    scopus 로고
    • Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement
    • Pirker, W.; Kocher, A. Immediate, non-submerged, root-analogue zirconia implant in single tooth replacement. Int. J. Oral Maxillofac. Surg. 2008, 37, 293-295.
    • (2008) Int. J. Oral Maxillofac. Surg , vol.37 , pp. 293-295
    • Pirker, W.1    Kocher, A.2
  • 132
    • 84861167675 scopus 로고    scopus 로고
    • Root analog zirconia implants: True anatomical design for molar replacement-A case report
    • Pirker, W.; Kocher, A. Root analog zirconia implants: True anatomical design for molar replacement-A case report. Int. J. Periodontics Restor. 2011, 31, 663-668.
    • (2011) Int. J. Periodontics Restor , vol.31 , pp. 663-668
    • Pirker, W.1    Kocher, A.2
  • 133
    • 77951232958 scopus 로고    scopus 로고
    • Single-tooth zirconia implant located in anterior maxilla
    • Aydin, C.; Yilmaz, H.; Ata, S.O. Single-tooth zirconia implant located in anterior maxilla. N. Y. State Dent. J. 2010, 76, 30-33.
    • (2010) N. Y. State Dent. J , vol.76 , pp. 30-33
    • Aydin, C.1    Yilmaz, H.2    Ata, S.O.3
  • 134
    • 79951951006 scopus 로고    scopus 로고
    • Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: A case report with 2.5 years follow-up
    • Pirker, W.; Wiedemann, D.; Lidauer, A.; Kocher, A. Immediate, single stage, truly anatomic zirconia implant in lower molar replacement: A case report with 2.5 years follow-up. Int. J. Oral Maxillofac. Surg. 2011, 40, 212-216.
    • (2011) Int. J. Oral Maxillofac. Surg , vol.40 , pp. 212-216
    • Pirker, W.1    Wiedemann, D.2    Lidauer, A.3    Kocher, A.4
  • 136
    • 84875628850 scopus 로고    scopus 로고
    • Immediate provisional restoration of single-piece zirconia implants: A prospective case series-Results after 24 months of clinical function
    • Payer, M.; Arnetzl, V.; Kirmeier, R.; Koller, M.; Arnetzl, G.; Jakse, N. Immediate provisional restoration of single-piece zirconia implants: A prospective case series-Results after 24 months of clinical function. Clin. Oral Implants Res. 2013, 24, 569-575.
    • (2013) Clin. Oral Implants Res , vol.24 , pp. 569-575
    • Payer, M.1    Arnetzl, V.2    Kirmeier, R.3    Koller, M.4    Arnetzl, G.5    Jakse, N.6
  • 137
    • 71249138907 scopus 로고    scopus 로고
    • Immediate, non-submerged, root-analogue zirconia implants placed into single-rooted extraction sockets: 2-year follow-up of a clinical study
    • Pirker, W.; Kocher, A. Immediate, non-submerged, root-analogue zirconia implants placed into single-rooted extraction sockets: 2-year follow-up of a clinical study. Int. J. Oral Maxillofac. Surg. 2009, 3, 1127-1132.
    • (2009) Int. J. Oral Maxillofac. Surg , vol.3 , pp. 1127-1132
    • Pirker, W.1    Kocher, A.2
  • 138
    • 77953268333 scopus 로고    scopus 로고
    • Five year success rate of 831 consecutively placed zirconia dental implants in humans: A comparison of three different rough surfaces
    • Oliva, J.; Oliva, X.; Oliva, J. Five year success rate of 831 consecutively placed zirconia dental implants in humans: A comparison of three different rough surfaces. Int. J. Oral Maxillofac. Implants 2010, 25, 336-344.
    • (2010) Int. J. Oral Maxillofac. Implants , vol.25 , pp. 336-344
    • Oliva, J.1    Oliva, X.2    Oliva, J.3
  • 139
    • 84868588291 scopus 로고    scopus 로고
    • Multiple teeth replacement with endosseous one-piece yttrium-stabilized zirconia dental implants
    • Borgonovo, A.E.; Fabbri, A.; Vavassori, V.; Censi, R.; Maiorana, C. Multiple teeth replacement with endosseous one-piece yttrium-stabilized zirconia dental implants. Med. Oral Patol. Oral Cir. Bucal 2012, 17, e981-e987.
    • (2012) Med. Oral Patol. Oral Cir. Bucal , vol.17 , pp. e981-e987
    • Borgonovo, A.E.1    Fabbri, A.2    Vavassori, V.3    Censi, R.4    Maiorana, C.5
  • 140
    • 84884240770 scopus 로고    scopus 로고
    • Evaluation of the success criteria for zirconia dental implants: A four-year clinical and radiological study
    • Borgonovo, A.E.; Censi, R.; Vavassori, V.; Dolci, M.; Josè Luis, C.-G.; Ruiz, R.A.D.; Maiorana, C. Evaluation of the success criteria for zirconia dental implants: A four-year clinical and radiological study. Int. J. Dent. 2013, 2013, doi:10.1155/2013/463073.
    • (2013) Int. J. Dent , vol.2013
    • Borgonovo, A.E.1    Censi, R.2    Vavassori, V.3    Dolci, M.4    Josè Luis, C.-G.5    Ruiz, R.A.D.6    Maiorana, C.7
  • 141
    • 84921948360 scopus 로고    scopus 로고
    • Zirconia dental implants: A clinical, radiographic, and microbiologic evaluation up to 3 years
    • Brüll, F.; van Winkelhoff, A.; Cune, M.S. Zirconia dental implants: A clinical, radiographic, and microbiologic evaluation up to 3 years. Int. J. Oral Maxillofac. Implants 2014, 29, 914-920.
    • (2014) Int. J. Oral Maxillofac. Implants , vol.29 , pp. 914-920
    • Brüll, F.1    van Winkelhoff, A.2    Cune, M.S.3
  • 142
    • 84861093226 scopus 로고    scopus 로고
    • One-piece zirconia oral implants: One-year results from a prospective cohort study. 1. Single tooth replacement.
    • Kohal, R.J.; Knauf, M.; Larsson, B.; Sahlin, H.; Butz, F. One-piece zirconia oral implants: One-year results from a prospective cohort study. 1. Single tooth replacement. J. Clin. Periodontol. 2012, 39, 590-597.
    • (2012) J. Clin. Periodontol , vol.39 , pp. 590-597
    • Kohal, R.J.1    Knauf, M.2    Larsson, B.3    Sahlin, H.4    Butz, F.5
  • 143
    • 84876041974 scopus 로고    scopus 로고
    • One-piece zirconia oral implants: One-year results from a prospective case series. 2. Three-unit fixed dental prosthesis (FDP) reconstruction
    • Kohal, R.-J.; Patzelt, S.B.M.; Butz, F.; Sahlin, H. One-piece zirconia oral implants: One-year results from a prospective case series. 2. Three-unit fixed dental prosthesis (FDP) reconstruction. J. Clin. Periodontol. 2013, 40, 553-562.
    • (2013) J. Clin. Periodontol , vol.40 , pp. 553-562
    • Kohal, R.-J.1    Patzelt, S.B.M.2    Butz, F.3    Sahlin, H.4
  • 144
    • 77956197362 scopus 로고    scopus 로고
    • Immediate occlusal versus non-occlusal loading of single zirconia implants. A multicentre pragmatic randomized clinical trial.
    • Cannizzaro, G.; Torchio, C.; Felice, P.; Leone, M.; Esposito, M. Immediate occlusal versus non-occlusal loading of single zirconia implants. A multicentre pragmatic randomized clinical trial. Eur. J. Oral Implantol. 2010, 3, 111-120.
    • (2010) Eur. J. Oral Implantol , vol.3 , pp. 111-120
    • Cannizzaro, G.1    Torchio, C.2    Felice, P.3    Leone, M.4    Esposito, M.5
  • 145
    • 84924268701 scopus 로고    scopus 로고
    • Two-piece-zirconia implants supporting all-ceramic crowns. A prospective clinical study.
    • Cionca, N.; Müller, N.; Mombelli, A. Two-piece-zirconia implants supporting all-ceramic crowns. A prospective clinical study. Clin. Oral Implants Res. 2014, doi:10.1111/clr.12370.
    • (2014) Clin. Oral Implants Res.
    • Cionca, N.1    Müller, N.2    Mombelli, A.3
  • 146
  • 147
    • 84898485918 scopus 로고    scopus 로고
    • Patients' perspectives on zirconia and titanium implants with a novel distribution supporting maxillary and mandibular overdentures: A qualitative study
    • Osman, R.B.; Morgaine, K.C.; Duncan, W.; Swain, M.V.; Ma, S. Patients' perspectives on zirconia and titanium implants with a novel distribution supporting maxillary and mandibular overdentures: A qualitative study. Clin. Oral Implants Res. 2014, 25, 587-597.
    • (2014) Clin. Oral Implants Res , vol.25 , pp. 587-597
    • Osman, R.B.1    Morgaine, K.C.2    Duncan, W.3    Swain, M.V.4    Ma, S.5
  • 148
    • 84912040894 scopus 로고    scopus 로고
    • Ceramic implants (Y-TZP): Are they a viable alternative to titanium implants for the support of overdentures? A randomized clinical trial
    • Osman, R.B.; Swain, M.V.; Atieh, M.; Ma, S.; Duncan, W. Ceramic implants (Y-TZP): Are they a viable alternative to titanium implants for the support of overdentures? A randomized clinical trial. Clin. Oral Implants Res. 2014, 25, 1366-1377.
    • (2014) Clin. Oral Implants Res , vol.25 , pp. 1366-1377
    • Osman, R.B.1    Swain, M.V.2    Atieh, M.3    Ma, S.4    Duncan, W.5
  • 150
    • 84900012973 scopus 로고    scopus 로고
    • Trends in computer-aided manufacturing in prosthodontics: A review of the available streams
    • Abduo, J.; Lyons, K.; Bennamoun, M. Trends in computer-aided manufacturing in prosthodontics: A review of the available streams. Int. J. Dent. 2014, 2014, 1-15.
    • (2014) Int. J. Dent , vol.2014 , pp. 1-15
    • Abduo, J.1    Lyons, K.2    Bennamoun, M.3
  • 151
    • 84901801262 scopus 로고    scopus 로고
    • Novel prospects and possibilities in additive manufacturing of ceramics by means of direct inkjet printing
    • Wätjen, A.M.; Gingter, P.; Kramer, M.; Telle, R. Novel prospects and possibilities in additive manufacturing of ceramics by means of direct inkjet printing. Adv. Mech. Eng. 2014, 2014, doi:10.1155/2014/141346.
    • (2014) Adv. Mech. Eng , vol.2014
    • Wätjen, A.M.1    Gingter, P.2    Kramer, M.3    Telle, R.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.