메뉴 건너뛰기




Volumn 62, Issue 5, 2012, Pages 454-460

Effect of preoperative warming during cesarean section under spinal anesthesia

Author keywords

Cesarean section; Shivering; Spinal anesthesia; Warming

Indexed keywords

ADULT; APGAR SCORE; ARTICLE; BLOOD PH; CESAREAN SECTION; CLINICAL ARTICLE; CONTROLLED STUDY; CORE TEMPERATURE; FEMALE; HUMAN; HYPOTHERMIA; POSTOPERATIVE COMPLICATION; PREOPERATIVE PERIOD; PREOPERATIVE TREATMENT; PREOPERATIVE WARMING; RANDOMIZED CONTROLLED TRIAL; SHIVERING; SKIN TEMPERATURE; SPINAL ANESTHESIA; UMBILICAL VEIN; WARMING;

EID: 84930476064     PISSN: 20056419     EISSN: 20057563     Source Type: Journal    
DOI: 10.4097/kjae.2012.62.5.454     Document Type: Article
Times cited : (52)

References (28)
  • 2
    • 0346102651 scopus 로고    scopus 로고
    • Intrathecal meperidine decreases shivering during cesarean delivery under spinal anesthesia
    • Roy JD, Girard M, Drolet P. Intrathecal meperidine decreases shivering during cesarean delivery under spinal anesthesia. Anesth Analg 2004; 98: 230-4.
    • (2004) Anesth Analg , vol.98 , pp. 230-234
    • Roy, J.D.1    Girard, M.2    Drolet, P.3
  • 3
    • 0036161971 scopus 로고    scopus 로고
    • Perioperative shivering: Physiology and pharmacology
    • De Witte J, Sessler DI. Perioperative shivering: physiology and pharmacology. Anesthesiology 2002; 96: 467-84.
    • (2002) Anesthesiology , vol.96 , pp. 467-484
    • De Witte, J.1    Sessler, D.I.2
  • 4
    • 0023224107 scopus 로고
    • Effect of meperidine on oxygen consumption, carbon dioxide production, and respiratory gas exchange in postanesthesia shivering
    • Macintyre PE, Pavlin EG, Dwersteg JF. Effect of meperidine on oxygen consumption, carbon dioxide production, and respiratory gas exchange in postanesthesia shivering. Anesth Analg 1987; 66: 751-5.
    • (1987) Anesth Analg , vol.66 , pp. 751-755
    • Macintyre, P.E.1    Pavlin, E.G.2    Dwersteg, J.F.3
  • 5
    • 0026628212 scopus 로고
    • Epidural versus general anesthesia, ambient operating room temperature, and patient age as predictors of inadvertent hypothermia
    • Frank SM, Beattie C, Christopherson R, Norris EJ, Rock P, Parker S, et al. Epidural versus general anesthesia, ambient operating room temperature, and patient age as predictors of inadvertent hypothermia. Anesthesiology 1992; 77: 252-7.
    • (1992) Anesthesiology , vol.77 , pp. 252-257
    • Frank, S.M.1    Beattie, C.2    Christopherson, R.3    Norris, E.J.4    Rock, P.5    Parker, S.6
  • 8
    • 0026498659 scopus 로고
    • Intraoperative warming therapies: A comparison of three devices
    • Hynson JM, Sessler DI. Intraoperative warming therapies: a comparison of three devices. J Clin Anesth 1992; 4: 194-9.
    • (1992) J Clin Anesth , vol.4 , pp. 194-199
    • Hynson, J.M.1    Sessler, D.I.2
  • 9
    • 0027291769 scopus 로고
    • The effects of preinduction warming on temperature and blood pressure during propofol/nitrous oxide anesthesia
    • Hynson JM, Sessler DI, Moayeri A, McGuire J, Schroeder M. The effects of preinduction warming on temperature and blood pressure during propofol/nitrous oxide anesthesia. Anesthesiology 1993; 79: 219-28.
    • (1993) Anesthesiology , vol.79 , pp. 219-228
    • Hynson, J.M.1    Sessler, D.I.2    Moayeri, A.3    McGuire, J.4    Schroeder, M.5
  • 10
    • 0022611107 scopus 로고
    • Intravenous fluid temperature, shivering, and the parturient
    • Workhoven MN. Intravenous fluid temperature, shivering, and the parturient. Anesth Analg 1986; 65: 496-8.
    • (1986) Anesth Analg , vol.65 , pp. 496-498
    • Workhoven, M.N.1
  • 11
    • 70349278356 scopus 로고    scopus 로고
    • Intra-operative fluid warming in elective caesarean section: A blinded randomised controlled trial
    • Woolnough M, Allam J, Hemingway C, Cox M, Yentis SM. Intra-operative fluid warming in elective caesarean section: a blinded randomised controlled trial. Int J Obstet Anesth 2009; 18: 346-51.
    • (2009) Int J Obstet Anesth , vol.18 , pp. 346-351
    • Woolnough, M.1    Allam, J.2    Hemingway, C.3    Cox, M.4    Yentis, S.M.5
  • 13
    • 0030851186 scopus 로고    scopus 로고
    • Comparison between alfentanil, pethidine and placebo in the treatment of post-anaesthetic shivering
    • Wrench IJ, Cavill G, Ward JE, Crossley AW. Comparison between alfentanil, pethidine and placebo in the treatment of post-anaesthetic shivering. Br J Anaesth 1997; 79: 541-2.
    • (1997) Br J Anaesth , vol.79 , pp. 541-542
    • Wrench, I.J.1    Cavill, G.2    Ward, J.E.3    Crossley, A.W.4
  • 14
    • 0033952093 scopus 로고    scopus 로고
    • Perioperative heat balance
    • Sessler DI. Perioperative heat balance. Anesthesiology 2000; 92: 578-96.
    • (2000) Anesthesiology , vol.92 , pp. 578-596
    • Sessler, D.I.1
  • 15
    • 0028054160 scopus 로고
    • Epidural anesthesia increases apparent leg temperature and decreases the shivering threshold
    • Emerick TH, Ozaki M, Sessler DI, Walters K, Schroeder M. Epidural anesthesia increases apparent leg temperature and decreases the shivering threshold. Anesthesiology 1994; 81: 289-98.
    • (1994) Anesthesiology , vol.81 , pp. 289-298
    • Emerick, T.H.1    Ozaki, M.2    Sessler, D.I.3    Walters, K.4    Schroeder, M.5
  • 16
    • 0025011293 scopus 로고
    • High thoracic segmental epidural anesthesia diminishes sympathetic outflow to the legs, despite restriction of sensory blockade to the upper thorax
    • Hopf HB, Weissbach B, Peters J. High thoracic segmental epidural anesthesia diminishes sympathetic outflow to the legs, despite restriction of sensory blockade to the upper thorax. Anesthesiology 1990; 73: 882-9.
    • (1990) Anesthesiology , vol.73 , pp. 882-889
    • Hopf, H.B.1    Weissbach, B.2    Peters, J.3
  • 17
    • 0027485879 scopus 로고
    • Thermoregulatory response thresholds during spinal anesthesia
    • Kurz A, Sessler DI, Schroeder M, Kurz M. Thermoregulatory response thresholds during spinal anesthesia. Anesth Analg 1993; 77: 721-6.
    • (1993) Anesth Analg , vol.77 , pp. 721-726
    • Kurz, A.1    Sessler, D.I.2    Schroeder, M.3    Kurz, M.4
  • 18
    • 0015419753 scopus 로고
    • The causes of hypothermia during spinal anesthesia
    • Roe CF, Cohn FL. The causes of hypothermia during spinal anesthesia. Surg Gynecol Obstet 1972; 135: 577-80.
    • (1972) Surg Gynecol Obstet , vol.135 , pp. 577-580
    • Roe, C.F.1    Cohn, F.L.2
  • 19
    • 30744431620 scopus 로고    scopus 로고
    • Comparison of ondansetron and meperidine for prevention of shivering in patients undergoing spinal anesthesia
    • Kelsaka E, Baris S, Karakaya D, Sarihasan B. Comparison of ondansetron and meperidine for prevention of shivering in patients undergoing spinal anesthesia. Reg Anesth Pain Med 2006; 31: 40-5.
    • (2006) Reg Anesth Pain Med , vol.31 , pp. 40-45
    • Kelsaka, E.1    Baris, S.2    Karakaya, D.3    Sarihasan, B.4
  • 20
    • 51849169118 scopus 로고    scopus 로고
    • Comparison of prophylactic use of midazolam, ketamine, and ketamine plus midazolam for prevention of shivering during regional anaesthesia: A randomized double-blind placebo controlled trial
    • Honarmand A, Safavi MR. Comparison of prophylactic use of midazolam, ketamine, and ketamine plus midazolam for prevention of shivering during regional anaesthesia: a randomized double-blind placebo controlled trial. Br J Anaesth 2008; 101: 557-62.
    • (2008) Br J Anaesth , vol.101 , pp. 557-562
    • Honarmand, A.1    Safavi, M.R.2
  • 21
    • 0036138682 scopus 로고    scopus 로고
    • Transient neurological symptoms after subarachnoid meperidine
    • Lewis WR, Perrino AC Jr. Transient neurological symptoms after subarachnoid meperidine. Anesth Analg 2002; 94: 213-4.
    • (2002) Anesth Analg , vol.94 , pp. 213-214
    • Lewis, W.R.1    Perrino Jr., A.C.2
  • 22
    • 0028074605 scopus 로고
    • Respiratory depression associated with meperidine spinal anaesthesia
    • Ong B, Segstro R. Respiratory depression associated with meperidine spinal anaesthesia. Can J Anaesth 1994; 41: 725-7.
    • (1994) Can J Anaesth , vol.41 , pp. 725-727
    • Ong, B.1    Segstro, R.2
  • 23
    • 37349034920 scopus 로고    scopus 로고
    • Intraoperative forced air-warming during cesarean delivery under spinal anesthesia does not prevent maternal hypothermia
    • Butwick AJ, Lipman SS, Carvalho B. Intraoperative forced air-warming during cesarean delivery under spinal anesthesia does not prevent maternal hypothermia. Anesth Analg 2007; 105: 1413-9.
    • (2007) Anesth Analg , vol.105 , pp. 1413-1419
    • Butwick, A.J.1    Lipman, S.S.2    Carvalho, B.3
  • 24
    • 67650657152 scopus 로고    scopus 로고
    • Peri-operative warming in Caesarean sections
    • Petsas A, Vollmer H, Barnes R. Peri-operative warming in Caesarean sections. Anaesthesia 2009; 64: 921-2.
    • (2009) Anaesthesia , vol.64 , pp. 921-922
    • Petsas, A.1    Vollmer, H.2    Barnes, R.3
  • 25
    • 33746196778 scopus 로고    scopus 로고
    • Maternal and newborn outcomes related to maternal warming during cesarean delivery
    • Fallis WM, Hamelin K, Symonds J, Wang X. Maternal and newborn outcomes related to maternal warming during cesarean delivery. J Obstet Gynecol Neonatal Nurs 2006; 35: 324-31.
    • (2006) J Obstet Gynecol Neonatal Nurs , vol.35 , pp. 324-331
    • Fallis, W.M.1    Hamelin, K.2    Symonds, J.3    Wang, X.4
  • 26
    • 0031821134 scopus 로고    scopus 로고
    • Thermoregulatory effects of spinal and epidural anesthesia during cesarean delivery
    • Saito T, Sessler DI, Fujita K, Ooi Y, Jeffrey R. Thermoregulatory effects of spinal and epidural anesthesia during cesarean delivery. Reg Anesth Pain Med 1998; 23: 418-23.
    • (1998) Reg Anesth Pain Med , vol.23 , pp. 418-423
    • Saito, T.1    Sessler, D.I.2    Fujita, K.3    Ooi, Y.4    Jeffrey, R.5
  • 27
    • 0029893030 scopus 로고    scopus 로고
    • Reduction in the shivering threshold is proportional to spinal block height
    • Leslie K, Sessler DI. Reduction in the shivering threshold is proportional to spinal block height. Anesthesiology 1996; 84: 1327-31.
    • (1996) Anesthesiology , vol.84 , pp. 1327-1331
    • Leslie, K.1    Sessler, D.I.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.