메뉴 건너뛰기




Volumn 98, Issue , 2015, Pages 10-18

A study on the application of sorptive building materials to reduce the concentration and volume of contaminants inhaled by occupants in office areas

Author keywords

Computational fluid dynamics; Indoor air quality; Sorptive building materials; Toluene

Indexed keywords

AIR; AIR QUALITY; BUILDING MATERIALS; BUILDINGS; COMPUTATIONAL FLUID DYNAMICS; ENERGY UTILIZATION; FLUID DYNAMICS; IMPURITIES; INDOOR AIR POLLUTION; INTELLIGENT BUILDINGS; TOLUENE;

EID: 84930272056     PISSN: 03787788     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.enbuild.2014.12.056     Document Type: Article
Times cited : (13)

References (28)
  • 2
    • 77949615792 scopus 로고    scopus 로고
    • Building pathology, investigation of sick buildings - VOC emissions
    • C.W.F Yu, and J.T. Kim Building pathology, investigation of sick buildings - VOC emissions Indoor Built Environ. 19 2010 30 39
    • (2010) Indoor Built Environ. , vol.19 , pp. 30-39
    • Yu, C.W.F.1    Kim, J.T.2
  • 3
    • 77953420031 scopus 로고    scopus 로고
    • The applicability of epidemiological methods to the assessment of the risks to human health of indoor air pollution: An overview
    • T. Brow, P. Holmes, and P.T.C Harrison The applicability of epidemiological methods to the assessment of the risks to human health of indoor air pollution: an overview Indoor Built Environ. 19 2010 311 326
    • (2010) Indoor Built Environ. , vol.19 , pp. 311-326
    • Brow, T.1    Holmes, P.2    Harrison, P.T.C.3
  • 5
    • 77953416905 scopus 로고    scopus 로고
    • Actions to reduce the impact of construction products on indoor air: Outcomes of the European Project Healthy Air
    • P.M. Bluyssen, S.D. Richmont, D. Crump, F. Maupetit, T. Witterseh, and P. Gajdos Actions to reduce the impact of construction products on indoor air: outcomes of the European Project Healthy Air Indoor Built Environ. 19 2010 327 339
    • (2010) Indoor Built Environ. , vol.19 , pp. 327-339
    • Bluyssen, P.M.1    Richmont, S.D.2    Crump, D.3    Maupetit, F.4    Witterseh, T.5    Gajdos, P.6
  • 6
    • 84857045282 scopus 로고    scopus 로고
    • A finish material management buildings (FinIAQ)
    • S. Lee, G. Kwon, J. Joo, J.T. Kim, and S. Kim A finish material management buildings (FinIAQ) Energy Build. 46 2012 68 79
    • (2012) Energy Build. , vol.46 , pp. 68-79
    • Lee, S.1    Kwon, G.2    Joo, J.3    Kim, J.T.4    Kim, S.5
  • 7
    • 84930274270 scopus 로고    scopus 로고
    • VOC emission from building products: Soruces, testing and emission data
    • CRC Ltd. Watford
    • C. Yu, and D. Crump VOC emission from building products: soruces, testing and emission data BRE Digest 464 Part 1 2002 CRC Ltd. Watford
    • (2002) BRE Digest 464 Part 1
    • Yu, C.1    Crump, D.2
  • 8
    • 13444259571 scopus 로고    scopus 로고
    • Study of effect of adsorptive building material on formaldehyde concentrations: Development of measuring methods and modeling of adsorption phenomena
    • Y. Ataka, S. Kato, S. Murakami, Q. Zhu, K. Ito, and T. Yokota Study of effect of adsorptive building material on formaldehyde concentrations: development of measuring methods and modeling of adsorption phenomena Indoor Air 14 2004 432 445
    • (2004) Indoor Air , vol.14 , pp. 432-445
    • Ataka, Y.1    Kato, S.2    Murakami, S.3    Zhu, Q.4    Ito, K.5    Yokota, T.6
  • 9
    • 84879425451 scopus 로고    scopus 로고
    • A study on the mock up test for reduction of hcho using the functional gypsum board
    • (In Korean)
    • H. Kim, K. Song, and Y. Lee A study on the mock up test for reduction of hcho using the functional gypsum board Korean J. Air-Cond. Refrig. Eng. 20 2008 814 819 (In Korean)
    • (2008) Korean J. Air-Cond. Refrig. Eng. , vol.20 , pp. 814-819
    • Kim, H.1    Song, K.2    Lee, Y.3
  • 10
    • 77955860781 scopus 로고    scopus 로고
    • The effect of ventilation rate and filter performance on indoor particle concentration and fan power consumption in a residential housing unit
    • K. Noh, and J. Hwang The effect of ventilation rate and filter performance on indoor particle concentration and fan power consumption in a residential housing unit Indoor Built Environ. 19 2010 444 452
    • (2010) Indoor Built Environ. , vol.19 , pp. 444-452
    • Noh, K.1    Hwang, J.2
  • 11
    • 83455195625 scopus 로고    scopus 로고
    • A detailed study of window-type air-conditioner filtration of PM2.5 in residential building of Hong Kong
    • H.K.C. Mak, D.W.T. Chan, L.K.C. Law, and T.C.W. Tung A detailed study of window-type air-conditioner filtration of PM2.5 in residential building of Hong Kong Indoor Built Environ. 20 2011 595 606
    • (2011) Indoor Built Environ. , vol.20 , pp. 595-606
    • Mak, H.K.C.1    Chan, D.W.T.2    Law, L.K.C.3    Tung, T.C.W.4
  • 12
    • 77955871146 scopus 로고    scopus 로고
    • Influence of environmental factors on performance of sorptive building materials
    • J. Seo, S. Kato, Y. Ataka, and J. Yang Influence of environmental factors on performance of sorptive building materials Indoor Built Environ. 19 2010 413 421
    • (2010) Indoor Built Environ. , vol.19 , pp. 413-421
    • Seo, J.1    Kato, S.2    Ataka, Y.3    Yang, J.4
  • 13
    • 13444259571 scopus 로고    scopus 로고
    • Study of effect of adsorptive building material on formaldehyde concentrations: Development of measuring methods and modeling of adsorption phenomena
    • Y. Ataka, S. Kato, Y. Ataka, and S. Chino Study of effect of adsorptive building material on formaldehyde concentrations: development of measuring methods and modeling of adsorption phenomena Indoor Air 14 2004 51 64
    • (2004) Indoor Air , vol.14 , pp. 51-64
    • Ataka, Y.1    Kato, S.2    Ataka, Y.3    Chino, S.4
  • 14
    • 51449095727 scopus 로고    scopus 로고
    • Performance test for evaluating the reduction of VOCs in rooms and evaluating the lifetime of sorptive building materials
    • J. Seo, S. Kato, Y. Ataka, and S. Chino Performance test for evaluating the reduction of VOCs in rooms and evaluating the lifetime of sorptive building materials Building and Environ. 44 2009 207 215
    • (2009) Building and Environ. , vol.44 , pp. 207-215
    • Seo, J.1    Kato, S.2    Ataka, Y.3    Chino, S.4
  • 15
    • 60749130524 scopus 로고    scopus 로고
    • The contaminant removal efficiency of an air cleaner using the adsorption/desorption effect
    • H. Matsumoto, M. Shimizu, and H. Sato The contaminant removal efficiency of an air cleaner using the adsorption/desorption effect Build. Environ. 44 2009 1371 1377
    • (2009) Build. Environ. , vol.44 , pp. 1371-1377
    • Matsumoto, H.1    Shimizu, M.2    Sato, H.3
  • 16
    • 67651124819 scopus 로고    scopus 로고
    • Adsorption behaviors of volatile organic compounds (VOCs) on porous clay heterostructures (PCH)
    • F. Qu, L. Zhu, and K. Yang Adsorption behaviors of volatile organic compounds (VOCs) on porous clay heterostructures (PCH) J. Hazard. Mat. 170 2009 7 12
    • (2009) J. Hazard. Mat. , vol.170 , pp. 7-12
    • Qu, F.1    Zhu, L.2    Yang, K.3
  • 17
    • 0023247024 scopus 로고
    • Calculation of age and local purging flow rate in rooms
    • L. Davidson, and E. Olsson Calculation of age and local purging flow rate in rooms Build. Environ. 22 1987 111 127
    • (1987) Build. Environ. , vol.22 , pp. 111-127
    • Davidson, L.1    Olsson, E.2
  • 18
    • 0041949583 scopus 로고
    • New scales for evaluating ventilation efficiency as affected by supply and exhaust openings based on spatial distribution of contaminant
    • University of Tokyo Tokyo, Japan
    • S. Kato, S. Murakami, and H. Kobayashi New scales for evaluating ventilation efficiency as affected by supply and exhaust openings based on spatial distribution of contaminant Proceedings of the International Symposium on Room Air Convection and Ventilation Effectiveness 1992 University of Tokyo Tokyo, Japan 321 332
    • (1992) Proceedings of the International Symposium on Room Air Convection and Ventilation Effectiveness , pp. 321-332
    • Kato, S.1    Murakami, S.2    Kobayashi, H.3
  • 19
    • 0037520575 scopus 로고
    • New scales for ventilation efficiency and their application based on numerical simulation of room airflow
    • University of Tokyo Tokyo, Japan
    • S. Murakami New scales for ventilation efficiency and their application based on numerical simulation of room airflow International Symposium on Room Air Convection and Ventilation Effectiveness 1992 University of Tokyo Tokyo, Japan 22 38
    • (1992) International Symposium on Room Air Convection and Ventilation Effectiveness , pp. 22-38
    • Murakami, S.1
  • 20
    • 84872009506 scopus 로고    scopus 로고
    • New ventilation index for evaluating imperfect mixing condition - Analysis of net escape velocity based on RANS approach
    • E. Lim, K. Ito, and M. Sandberg New ventilation index for evaluating imperfect mixing condition - analysis of net escape velocity based on RANS approach Build. Environ. 61 2013 45 56
    • (2013) Build. Environ. , vol.61 , pp. 45-56
    • Lim, E.1    Ito, K.2    Sandberg, M.3
  • 21
    • 84930273395 scopus 로고    scopus 로고
    • Evaluation of contaminant concentration reduction effect of sorptive building materials by new ventilation index - Net escape velocity
    • (In Korean)
    • E. Lim Evaluation of contaminant concentration reduction effect of sorptive building materials by new ventilation index - net escape velocity J. Archit. Inst. Korea Plan. Design 29 2013 291 298 (In Korean)
    • (2013) J. Archit. Inst. Korea Plan. Design , vol.29 , pp. 291-298
    • Lim, E.1
  • 22
    • 84930276044 scopus 로고    scopus 로고
    • Optimum installation of sorptive building materials for reducing concentration of indoor air pollutant
    • (In Korean)
    • S. Park, and J. Seo Optimum installation of sorptive building materials for reducing concentration of indoor air pollutant J. Reg. Assoc. Archit. Inst. Korea 14 2012 319 326 (In Korean)
    • (2012) J. Reg. Assoc. Archit. Inst. Korea , vol.14 , pp. 319-326
    • Park, S.1    Seo, J.2
  • 23
    • 0028835392 scopus 로고
    • Influences on sick building syndrome symptoms in three buildings
    • M.O. Bachmann, and J.E. Myers Influences on sick building syndrome symptoms in three buildings Social Sci. Med. 40 1995 245 251
    • (1995) Social Sci. Med. , vol.40 , pp. 245-251
    • Bachmann, M.O.1    Myers, J.E.2
  • 24
    • 21644475946 scopus 로고    scopus 로고
    • Study on inhalation region by means of CFD analysis and experiment
    • S. Zhu, S. Kato, S. Murakami, and T. Hayashi Study on inhalation region by means of CFD analysis and experiment Build. Environ. 40 2005 1329 1336
    • (2005) Build. Environ. , vol.40 , pp. 1329-1336
    • Zhu, S.1    Kato, S.2    Murakami, S.3    Hayashi, T.4
  • 25
    • 0028196211 scopus 로고
    • A new turbulence model for predicting fluid flow and heat transfer in separating and reattaching flows - I. Flow field calculations
    • K. Abe, T. Kondoh, and Y. Nagano A new turbulence model for predicting fluid flow and heat transfer in separating and reattaching flows - I. Flow field calculations Int. J. Heat Mass Transf. 37 1994 139 151
    • (1994) Int. J. Heat Mass Transf. , vol.37 , pp. 139-151
    • Abe, K.1    Kondoh, T.2    Nagano, Y.3
  • 26
    • 0003401223 scopus 로고    scopus 로고
    • The Society of Chemical Engineers Tokyo, Japan
    • The Society of Chemical Engineers, Handbook of Chemistry, Tokyo, Japan, 1999.
    • (1999) Handbook of Chemistry
  • 27
    • 84876161256 scopus 로고    scopus 로고
    • Control of emission rates of chemical compounds emitted by controlling their mass transfer coefficients on the surface of the tested building material
    • J. Seo, S. Lee, S. Kim, and Y. Nam Control of emission rates of chemical compounds emitted by controlling their mass transfer coefficients on the surface of the tested building material J. Adhes. Sci. Technol. 27 2013 610 619
    • (2013) J. Adhes. Sci. Technol. , vol.27 , pp. 610-619
    • Seo, J.1    Lee, S.2    Kim, S.3    Nam, Y.4
  • 28
    • 0036498201 scopus 로고    scopus 로고
    • CFD analysis on characteristics of contaminated indoor air ventilation and its application in the evaluation of the effects of contaminant inhalation by a human occupant
    • T. Hayashi, Y. Ishizu, S. Kato, and S. Murakami CFD analysis on characteristics of contaminated indoor air ventilation and its application in the evaluation of the effects of contaminant inhalation by a human occupant Build. Environ. 37 2002 219 230
    • (2002) Build. Environ. , vol.37 , pp. 219-230
    • Hayashi, T.1    Ishizu, Y.2    Kato, S.3    Murakami, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.