메뉴 건너뛰기




Volumn 8, Issue 6, 2015, Pages 850-857

Percutaneous mitral valve replacement using a transvenous, transseptal approach: Transvenous mitral valve replacement

Author keywords

degenerative mitral prosthesis; percutaneous mitral intervention; percutaneous mitral repair; transcatheter mitral valve replacement; transcatheter valve in ring procedure; transcatheter valve in valve procedure

Indexed keywords

ADULT; AGED; ARTICLE; ASSESSMENT OF HUMANS; CASE REPORT; COMPUTER ASSISTED TOMOGRAPHY; DYSPNEA; ECHOCARDIOGRAPHY; FEASIBILITY STUDY; FEMALE; HEART CATHETERIZATION; HUMAN; MIDDLE AGED; MITRAL VALVE PROSTHESIS; MITRAL VALVE REGURGITATION; MITRAL VALVE REPLACEMENT; PERCUTANEOUS AORTIC VALVE; PRIORITY JOURNAL; REOPERATION; SOCIETY OF THORACIC SURGEONS RISK SCORE; SURGICAL APPROACH; TRANSESOPHAGEAL ECHOCARDIOGRAPHY; TRANSTHORACIC ECHOCARDIOGRAPHY; VERY ELDERLY; ADVERSE EFFECTS; COLOR DOPPLER ECHOCARDIOGRAPHY; CONVALESCENCE; DEVICES; ECHOGRAPHY; HEART VALVE PROSTHESIS; HEART VALVE REPLACEMENT; MALE; MITRAL VALVE; PATHOPHYSIOLOGY; PROCEDURES; PROSTHESIS DESIGN; PROSTHESIS FAILURE; RADIOGRAPHY; RISK ASSESSMENT; RISK FACTOR; SURGERY; THREE DIMENSIONAL ECHOCARDIOGRAPHY; TIME FACTOR; TREATMENT OUTCOME;

EID: 84929575189     PISSN: 19368798     EISSN: 18767605     Source Type: Journal    
DOI: 10.1016/j.jcin.2015.01.028     Document Type: Article
Times cited : (31)

References (18)
  • 1
    • 79958204372 scopus 로고    scopus 로고
    • Transcatheter versus surgical aortic-valve replacement in high-risk patients
    • C.R. Smith, M.B. Leon, and M.J. Mack Transcatheter versus surgical aortic-valve replacement in high-risk patients N Engl J Med 364 2011 2187 2198
    • (2011) N Engl J Med , vol.364 , pp. 2187-2198
    • Smith, C.R.1    Leon, M.B.2    MacK, M.J.3
  • 2
    • 84855383997 scopus 로고    scopus 로고
    • Acute and 12-month results with catheter-based mitral valve leaflet repair: The EVEREST II (Endovascular Valve Edge-to-Edge Repair) High Risk Study
    • P.L. Whitlow, T. Feldman, and W.R. Pedersen Acute and 12-month results with catheter-based mitral valve leaflet repair: the EVEREST II (Endovascular Valve Edge-to-Edge Repair) High Risk Study J Am Coll Cardiol 59 2012 130 139
    • (2012) J Am Coll Cardiol , vol.59 , pp. 130-139
    • Whitlow, P.L.1    Feldman, T.2    Pedersen, W.R.3
  • 3
    • 84899811656 scopus 로고    scopus 로고
    • Transcatheter aortic-valve replacement with a self-expanding prosthesis
    • D.H. Adams, J.J. Popma, and M.J. Reardon Transcatheter aortic-valve replacement with a self-expanding prosthesis N Engl J Med 370 2014 1790 1798
    • (2014) N Engl J Med , vol.370 , pp. 1790-1798
    • Adams, D.H.1    Popma, J.J.2    Reardon, M.J.3
  • 6
    • 77955463308 scopus 로고    scopus 로고
    • Predictors of mitral regurgitation recurrence in patients with heart failure undergoing mitral valve annuloplasty
    • A. Ciarka, J. Braun, and V. Delgado Predictors of mitral regurgitation recurrence in patients with heart failure undergoing mitral valve annuloplasty Am J Cardiol 106 2010 395 401
    • (2010) Am J Cardiol , vol.106 , pp. 395-401
    • Ciarka, A.1    Braun, J.2    Delgado, V.3
  • 7
    • 42949124844 scopus 로고    scopus 로고
    • Recurrent mitral regurgitation and risk factors for early and late mortality after mitral valve repair for functional ischemic mitral regurgitation
    • discussion 1542-3
    • T.D. Crabtree, M.S. Bailey, and M.R. Moon Recurrent mitral regurgitation and risk factors for early and late mortality after mitral valve repair for functional ischemic mitral regurgitation Ann Thorac Surg 85 2008 1537 1542 discussion 1542-3
    • (2008) Ann Thorac Surg , vol.85 , pp. 1537-1542
    • Crabtree, T.D.1    Bailey, M.S.2    Moon, M.R.3
  • 8
    • 84863480156 scopus 로고    scopus 로고
    • Outcome after redo-mitral valve replacement in adult patients: A 10-year single-centre experience
    • H.A. Vohra, R.N. Whistance, and A. Roubelakis Outcome after redo-mitral valve replacement in adult patients: a 10-year single-centre experience Interact Cardiovasc Thorac Surg 14 2012 575 579
    • (2012) Interact Cardiovasc Thorac Surg , vol.14 , pp. 575-579
    • Vohra, H.A.1    Whistance, R.N.2    Roubelakis, A.3
  • 9
    • 79951774414 scopus 로고    scopus 로고
    • Transcatheter transapical mitral valve-in-valve implantations for a failed bioprosthesis: A case series
    • A.W. Cheung, R. Gurvitch, and J. Ye Transcatheter transapical mitral valve-in-valve implantations for a failed bioprosthesis: a case series J Thorac Cardiovasc Surg 141 2011 711 715
    • (2011) J Thorac Cardiovasc Surg , vol.141 , pp. 711-715
    • Cheung, A.W.1    Gurvitch, R.2    Ye, J.3
  • 10
    • 84858763391 scopus 로고    scopus 로고
    • Transcatheter mitral valve-in-valve implantation in patients with degenerated bioprostheses
    • M. Seiffert, L. Conradi, and S. Baldus Transcatheter mitral valve-in-valve implantation in patients with degenerated bioprostheses J Am Coll Cardiol 5 2012 341 349
    • (2012) J Am Coll Cardiol , vol.5 , pp. 341-349
    • Seiffert, M.1    Conradi, L.2    Baldus, S.3
  • 11
    • 84871883260 scopus 로고    scopus 로고
    • Transapical transcatheter valve-in-valve implantation for deteriorated mitral valve bioprostheses
    • M. Wilbring, K. Alexiou, and S.M. Tugtekin Transapical transcatheter valve-in-valve implantation for deteriorated mitral valve bioprostheses Ann Thorac Surg 95 2013 111 117
    • (2013) Ann Thorac Surg , vol.95 , pp. 111-117
    • Wilbring, M.1    Alexiou, K.2    Tugtekin, S.M.3
  • 12
    • 84927668027 scopus 로고    scopus 로고
    • Percutaneous complete repair of failed mitral valve prosthesis: Simultaneous closure of mitral paravalvular leaks and transcatheter mitral valve implantation - Single-centre experience
    • C. Kliger, R. Angulo, and L. Maranan Percutaneous complete repair of failed mitral valve prosthesis: simultaneous closure of mitral paravalvular leaks and transcatheter mitral valve implantation - single-centre experience EuroIntervention 10 2015 1336 1345
    • (2015) EuroIntervention , vol.10 , pp. 1336-1345
    • Kliger, C.1    Angulo, R.2    Maranan, L.3
  • 13
    • 84879586698 scopus 로고    scopus 로고
    • Transcatheter valve-in-ring implantation after failure of surgical mitral repair
    • F. Descoutures, D. Himbert, and F. Maisano Transcatheter valve-in-ring implantation after failure of surgical mitral repair Eur J Cardiothorac Surg 44 2013 e8 e15
    • (2013) Eur J Cardiothorac Surg , vol.44 , pp. e8-e15
    • Descoutures, F.1    Himbert, D.2    Maisano, F.3
  • 14
    • 84879410557 scopus 로고    scopus 로고
    • Transvenous, antegrade Melody valve-in-valve implantation for bioprosthetic mitral and tricuspid valve dysfunction: A case series in children and adults
    • M.W. Cullen, A.K. Cabalka, and O.O. Alli Transvenous, antegrade Melody valve-in-valve implantation for bioprosthetic mitral and tricuspid valve dysfunction: a case series in children and adults J Am Coll Cardiol 6 2013 598 605
    • (2013) J Am Coll Cardiol , vol.6 , pp. 598-605
    • Cullen, M.W.1    Cabalka, A.K.2    Alli, O.O.3
  • 16
    • 82955173039 scopus 로고    scopus 로고
    • Transseptal implantation of a transcatheter heart valve in a mitral annuloplasty ring to treat mitral repair failure
    • D. Himbert, E. Brochet, and C. Radu Transseptal implantation of a transcatheter heart valve in a mitral annuloplasty ring to treat mitral repair failure Circ Cardiovasc Interv 4 2011 396 398
    • (2011) Circ Cardiovasc Interv , vol.4 , pp. 396-398
    • Himbert, D.1    Brochet, E.2    Radu, C.3
  • 17
    • 84876591620 scopus 로고    scopus 로고
    • 5-year experience with transcatheter transapical mitral valve-in-valve implantation for bioprosthetic valve dysfunction
    • A. Cheung, J.G. Webb, and M. Barbanti 5-year experience with transcatheter transapical mitral valve-in-valve implantation for bioprosthetic valve dysfunction J Am Coll Cardiol 61 2013 1759 1766
    • (2013) J Am Coll Cardiol , vol.61 , pp. 1759-1766
    • Cheung, A.1    Webb, J.G.2    Barbanti, M.3
  • 18
    • 84879420397 scopus 로고    scopus 로고
    • A guide to fluoroscopic identification and design of bioprosthetic valves: A reference for valve-in-valve procedure
    • V. Bapat, I. Mydin, S. Chadalavada, H. Tehrani, R. Attia, and M. Thomas A guide to fluoroscopic identification and design of bioprosthetic valves: a reference for valve-in-valve procedure Catheter Cardiovasc Interv 81 2013 853 861
    • (2013) Catheter Cardiovasc Interv , vol.81 , pp. 853-861
    • Bapat, V.1    Mydin, I.2    Chadalavada, S.3    Tehrani, H.4    Attia, R.5    Thomas, M.6


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.