-
1
-
-
84862808114
-
Electrochemical stripping analysis of nanogold label-induced silver deposition for ultrasensitive multiplexed detection of tumor markers
-
Lai G., Wang L., Wu J., Yan F. Electrochemical stripping analysis of nanogold label-induced silver deposition for ultrasensitive multiplexed detection of tumor markers. Anal. Chim. Acta 2012, 721:1-6.
-
(2012)
Anal. Chim. Acta
, vol.721
, pp. 1-6
-
-
Lai, G.1
Wang, L.2
Wu, J.3
Yan, F.4
-
2
-
-
79952818224
-
A colloidal gold probe-based silver enhancement immunochromatographic assay for the rapid detection of abrin-a
-
Yang W., Li X., Liu G., Zhang B., Zhang Y., Kong T., Tang J., Li D., Wang Z. A colloidal gold probe-based silver enhancement immunochromatographic assay for the rapid detection of abrin-a. Biosens. Bioelectron. 2011, 8:3710-3713.
-
(2011)
Biosens. Bioelectron.
, vol.8
, pp. 3710-3713
-
-
Yang, W.1
Li, X.2
Liu, G.3
Zhang, B.4
Zhang, Y.5
Kong, T.6
Tang, J.7
Li, D.8
Wang, Z.9
-
3
-
-
84890124537
-
Increased sensitivity of lateral flow immunoassay for ochratoxin A through silver enhancement
-
Anfossi L., Nardo F.D., Giovannoli C., Passini C., Baggiani C. Increased sensitivity of lateral flow immunoassay for ochratoxin A through silver enhancement. Anal. Bioanal. Chem. 2013, 30:9859-9867.
-
(2013)
Anal. Bioanal. Chem.
, vol.30
, pp. 9859-9867
-
-
Anfossi, L.1
Nardo, F.D.2
Giovannoli, C.3
Passini, C.4
Baggiani, C.5
-
4
-
-
84878143734
-
Gold immunochromatographic strips for enhanced detection of Avian influenza and Newcastle disease viruses
-
Li J., Zou M., Chen Y., Xue Q., Zhang F., Li B., Wang Y., Qi X., Yang Y. Gold immunochromatographic strips for enhanced detection of Avian influenza and Newcastle disease viruses. Anal. Chim. Acta 2013, 782:54-58.
-
(2013)
Anal. Chim. Acta
, vol.782
, pp. 54-58
-
-
Li, J.1
Zou, M.2
Chen, Y.3
Xue, Q.4
Zhang, F.5
Li, B.6
Wang, Y.7
Qi, X.8
Yang, Y.9
-
5
-
-
84927519075
-
Dual-layered and double-targeted nanogold based lateral flow immunoassay for influenza virus
-
Wiriyachaiporn N., Maneeprakorn W., Apiwat C., Dharakul T. Dual-layered and double-targeted nanogold based lateral flow immunoassay for influenza virus. Microchim. Acta 2015, 1-2:85-93.
-
(2015)
Microchim. Acta
, pp. 85-93
-
-
Wiriyachaiporn, N.1
Maneeprakorn, W.2
Apiwat, C.3
Dharakul, T.4
-
6
-
-
82755167808
-
Simultaneous detection of high-sensitivity cardiac troponin I and myoglobin by modified sandwich lateral flow immunoassay: proof of principle
-
Zhu J., Zou N., Zhu D., Wang J., Jin Q., Zhao J., Mao H. Simultaneous detection of high-sensitivity cardiac troponin I and myoglobin by modified sandwich lateral flow immunoassay: proof of principle. Clin. Chem. 2011, 12:1732-1738.
-
(2011)
Clin. Chem.
, vol.12
, pp. 1732-1738
-
-
Zhu, J.1
Zou, N.2
Zhu, D.3
Wang, J.4
Jin, Q.5
Zhao, J.6
Mao, H.7
-
7
-
-
84886077738
-
Oligonucleotide-linked gold nanoparticle aggregates for enhanced sensitivity in lateral flow assays
-
Hu J., Wang L., Li F., Han Y.L., Lin M., Lu T.J., Xu F. Oligonucleotide-linked gold nanoparticle aggregates for enhanced sensitivity in lateral flow assays. Lab Chip 2013, 22:4352-4357.
-
(2013)
Lab Chip
, vol.22
, pp. 4352-4357
-
-
Hu, J.1
Wang, L.2
Li, F.3
Han, Y.L.4
Lin, M.5
Lu, T.J.6
Xu, F.7
-
8
-
-
84879710481
-
One-step signal amplified lateral flow strip biosensor for ultrasensitive and on-site detection of bisphenol A (BPA) in aqueous samples
-
Mei Z., Qu W., Deng Y., Chu H., Cao J., Xue F., Zheng L., EI-Nezamic H., Wu Y., Chen W. One-step signal amplified lateral flow strip biosensor for ultrasensitive and on-site detection of bisphenol A (BPA) in aqueous samples. Biosens. Bioelectron. 2013, 49:457-461.
-
(2013)
Biosens. Bioelectron.
, vol.49
, pp. 457-461
-
-
Mei, Z.1
Qu, W.2
Deng, Y.3
Chu, H.4
Cao, J.5
Xue, F.6
Zheng, L.7
El-Nezamic, H.8
Wu, Y.9
Chen, W.10
-
9
-
-
77649336451
-
A dual gold nanoparticle conjugate-based lateral flow assay (LFA) method for the analysis of troponin I
-
Choi D.H., Lee S.K., Oh Y.K., Bae B.W., Lee S.D., Kim S., Shin Y.B., Kim M.G. A dual gold nanoparticle conjugate-based lateral flow assay (LFA) method for the analysis of troponin I. Biosens. Bioelectron. 2010, 8:1999-2002.
-
(2010)
Biosens. Bioelectron.
, vol.8
, pp. 1999-2002
-
-
Choi, D.H.1
Lee, S.K.2
Oh, Y.K.3
Bae, B.W.4
Lee, S.D.5
Kim, S.6
Shin, Y.B.7
Kim, M.G.8
-
10
-
-
84888270097
-
Advantages of fluorescent microspheres compared with colloidal gold as a label in immunochromatographic lateral flow assays
-
Xie Q.Y., Wu Y.H., Xiong Q.R., Xu H.Y., Xiong Y.H., Liu K., Jin Y., Lai W.H. Advantages of fluorescent microspheres compared with colloidal gold as a label in immunochromatographic lateral flow assays. Biosens. Bioelectron. 2014, 54:262-265.
-
(2014)
Biosens. Bioelectron.
, vol.54
, pp. 262-265
-
-
Xie, Q.Y.1
Wu, Y.H.2
Xiong, Q.R.3
Xu, H.Y.4
Xiong, Y.H.5
Liu, K.6
Jin, Y.7
Lai, W.H.8
-
11
-
-
79952620804
-
Detection of alpha-fetoprotein through biological signal amplification by biosensor based on imaging ellipsometry
-
Huang C., Chen Y., Wang C., Zhu W., Ma H., Jin G. Detection of alpha-fetoprotein through biological signal amplification by biosensor based on imaging ellipsometry. Thin Solid Films 2011, 9:2763-2767.
-
(2011)
Thin Solid Films
, vol.9
, pp. 2763-2767
-
-
Huang, C.1
Chen, Y.2
Wang, C.3
Zhu, W.4
Ma, H.5
Jin, G.6
-
12
-
-
84876717442
-
In-situ immuno-gold nanoparticle network ELISA biosensors for pathogen detection
-
Cho I.H., Irudayaraj J. In-situ immuno-gold nanoparticle network ELISA biosensors for pathogen detection. Int. J. Food Microbiol. 2013, 1:70-75.
-
(2013)
Int. J. Food Microbiol.
, vol.1
, pp. 70-75
-
-
Cho, I.H.1
Irudayaraj, J.2
-
13
-
-
84874671958
-
Rapid and sensitive immunodetection of Listeria monocytogenes in milk using a novel piezoelectric cantilever sensor
-
Sharma H., Mutharasan R. Rapid and sensitive immunodetection of Listeria monocytogenes in milk using a novel piezoelectric cantilever sensor. Biosens. Bioelectron. 2013, 45:158-162.
-
(2013)
Biosens. Bioelectron.
, vol.45
, pp. 158-162
-
-
Sharma, H.1
Mutharasan, R.2
-
14
-
-
79952814288
-
ZnO nanorods-enhanced fluorescence for sensitive microarray detection of cancers in serum without additional reporter-amplification
-
Hu W., Liu Y., Yang H., Zhou X., Li C.M. ZnO nanorods-enhanced fluorescence for sensitive microarray detection of cancers in serum without additional reporter-amplification. Biosens. Bioelectron. 2011, 8:3683-3687.
-
(2011)
Biosens. Bioelectron.
, vol.8
, pp. 3683-3687
-
-
Hu, W.1
Liu, Y.2
Yang, H.3
Zhou, X.4
Li, C.M.5
-
15
-
-
84893291149
-
Establishing of a method combined immunomagnetic separation with colloidal gold lateral flow assay and its application in rapid detection of Escherichia coli O157:H7
-
Cui X., Xiong Q.R., Xiong Y.H., Shan S., Lai W.H. Establishing of a method combined immunomagnetic separation with colloidal gold lateral flow assay and its application in rapid detection of Escherichia coli O157:H7. Chin. J. Anal. Chem. 2013, 12:1812-1816.
-
(2013)
Chin. J. Anal. Chem.
, vol.12
, pp. 1812-1816
-
-
Cui, X.1
Xiong, Q.R.2
Xiong, Y.H.3
Shan, S.4
Lai, W.H.5
-
16
-
-
49949099281
-
Enzyme-linked immuno-strip biosensor to detect Escherichia coli O157: H7
-
Park S., Kim H., Paek S.H., Hong J.W., Kim Y.K. Enzyme-linked immuno-strip biosensor to detect Escherichia coli O157: H7. Ultramicroscopy 2008, 10:1348-1351.
-
(2008)
Ultramicroscopy
, vol.10
, pp. 1348-1351
-
-
Park, S.1
Kim, H.2
Paek, S.H.3
Hong, J.W.4
Kim, Y.K.5
|