1
-
-
0742320773
-
Prediction of the sound field into high-rise building façades due to its balcony ceiling form
-
Dien H.H.E., Woloszyn P. Prediction of the sound field into high-rise building façades due to its balcony ceiling form. Appl Acoust 2004, 65:431-440.
-
(2004)
Appl Acoust
, vol.65
, pp. 431-440
-
-
Dien, H.H.E.1
Woloszyn, P.2
-
2
-
-
34249950920
-
Effects of apartment building façade and balcony design on the reduction of exterior noise
-
Lee P.J., Kim Y.H., Jeon J.Y., Song K.D. Effects of apartment building façade and balcony design on the reduction of exterior noise. Build Environ 2007, 42:3517-3528.
-
(2007)
Build Environ
, vol.42
, pp. 3517-3528
-
-
Lee, P.J.1
Kim, Y.H.2
Jeon, J.Y.3
Song, K.D.4
-
3
-
-
33748949926
-
Field measurements of façade sound insulation in residential buildings with balcony windows
-
Kim M.J., Kim H.G. Field measurements of façade sound insulation in residential buildings with balcony windows. Build Environ 2007, 42:1026-1035.
-
(2007)
Build Environ
, vol.42
, pp. 1026-1035
-
-
Kim, M.J.1
Kim, H.G.2
-
4
-
-
77955466558
-
Scale model study of balcony insertion losses on a building façade with non-parallel line sources
-
Tang S.K. Scale model study of balcony insertion losses on a building façade with non-parallel line sources. Appl Acoust 2010, 71:947-954.
-
(2010)
Appl Acoust
, vol.71
, pp. 947-954
-
-
Tang, S.K.1
-
5
-
-
84892857453
-
Simulating the effect of acoustic treatment types for residential balconies with road traffic noise
-
Naish D.A., Tan A.C.C., Demirbilek F.N. Simulating the effect of acoustic treatment types for residential balconies with road traffic noise. Appl Acoust 2014, 79:131-140.
-
(2014)
Appl Acoust
, vol.79
, pp. 131-140
-
-
Naish, D.A.1
Tan, A.C.C.2
Demirbilek, F.N.3
-
6
-
-
84856588893
-
Estimating health related costs and savings from balcony acoustic design for road traffic noise
-
Naish D.A., Tan A.C.C., Demirbilek F.N. Estimating health related costs and savings from balcony acoustic design for road traffic noise. Appl Acoust 2012, 73:497-507.
-
(2012)
Appl Acoust
, vol.73
, pp. 497-507
-
-
Naish, D.A.1
Tan, A.C.C.2
Demirbilek, F.N.3
-
7
-
-
84896891341
-
Associations between building characteristics and children's allergic symptoms - a cross-sectional study on child's health and home in Seoul, South Korea
-
Choi J., Chun C., Sun Y., Choi Y., Kwon S., Bornehag C.G., et al. Associations between building characteristics and children's allergic symptoms - a cross-sectional study on child's health and home in Seoul, South Korea. Build Environ 2014, 75:176-181.
-
(2014)
Build Environ
, vol.75
, pp. 176-181
-
-
Choi, J.1
Chun, C.2
Sun, Y.3
Choi, Y.4
Kwon, S.5
Bornehag, C.G.6
-
8
-
-
1542610617
-
A computational study on the use of balconies to reduce flame spread in high-rise apartment fires
-
Mammoser J.H., Battaglia F. A computational study on the use of balconies to reduce flame spread in high-rise apartment fires. Fire Saf 2004, 39:277-296.
-
(2004)
Fire Saf
, vol.39
, pp. 277-296
-
-
Mammoser, J.H.1
Battaglia, F.2
-
9
-
-
84881256930
-
CFD evaluation of new second-skin façade concept for wind comfort on building balconies: case study for the Park Tower in Antwerp
-
Montazeri H., Blocken B., Janssen W.D., van Hooff T. CFD evaluation of new second-skin façade concept for wind comfort on building balconies: case study for the Park Tower in Antwerp. Build Environ 2013, 68:179-192.
-
(2013)
Build Environ
, vol.68
, pp. 179-192
-
-
Montazeri, H.1
Blocken, B.2
Janssen, W.D.3
van Hooff, T.4
-
10
-
-
33746779349
-
Energy conservation effect of new HVAC system for condominiums with solar collectors integrated with the balcony handrail
-
Yoshie R., Satake A., Mochid A., Kato S., Yoshino H. Energy conservation effect of new HVAC system for condominiums with solar collectors integrated with the balcony handrail. Energy Build 2006, 38:1360-1367.
-
(2006)
Energy Build
, vol.38
, pp. 1360-1367
-
-
Yoshie, R.1
Satake, A.2
Mochid, A.3
Kato, S.4
Yoshino, H.5
-
11
-
-
84891404056
-
Thermal performance evaluation of fiber-reinforced polymer thermal breaks for balcony connections
-
Goulouti K., de Castro J., Vassilopoulos A.P., Keller T. Thermal performance evaluation of fiber-reinforced polymer thermal breaks for balcony connections. Energy Build 2014, 70:365-371.
-
(2014)
Energy Build
, vol.70
, pp. 365-371
-
-
Goulouti, K.1
de Castro, J.2
Vassilopoulos, A.P.3
Keller, T.4
-
12
-
-
84873935302
-
Impact of balcony thermal bridges on the overall thermal performance of multi-unit residential buildings: a case study
-
Ge H., McClung V.R., Zhang S. Impact of balcony thermal bridges on the overall thermal performance of multi-unit residential buildings: a case study. Energy Build 2013, 60:163-173.
-
(2013)
Energy Build
, vol.60
, pp. 163-173
-
-
Ge, H.1
McClung, V.R.2
Zhang, S.3
-
13
-
-
82355191619
-
Effect of building regulation on energy consumption in residential buildings in Korea
-
Song D., Choi Y.J. Effect of building regulation on energy consumption in residential buildings in Korea. Renew Sustain Energy Rev 2012, 16:1074-1081.
-
(2012)
Renew Sustain Energy Rev
, vol.16
, pp. 1074-1081
-
-
Song, D.1
Choi, Y.J.2
-
14
-
-
70350208805
-
Healthy-daylighting design for the living environment in apartments in Korea
-
Kim G., Kim J.T. Healthy-daylighting design for the living environment in apartments in Korea. Build Environ 2010, 45:287-294.
-
(2010)
Build Environ
, vol.45
, pp. 287-294
-
-
Kim, G.1
Kim, J.T.2
-
16
-
-
77957706941
-
Investigation on energy performance and energy payback period of application of balcony for residential apartment in Hong Kong
-
Chan A.L.S., Chow T.T. Investigation on energy performance and energy payback period of application of balcony for residential apartment in Hong Kong. Energy Build 2010, 42:2400-2405.
-
(2010)
Energy Build
, vol.42
, pp. 2400-2405
-
-
Chan, A.L.S.1
Chow, T.T.2
-
17
-
-
81855201725
-
Energy and carbon emission payback analysis for energy-efficient retrofitting in buildings - overhang shading option
-
Huang Y., Niu J.L., Chung T.M. Energy and carbon emission payback analysis for energy-efficient retrofitting in buildings - overhang shading option. Energy Build 2012, 44:94-103.
-
(2012)
Energy Build
, vol.44
, pp. 94-103
-
-
Huang, Y.1
Niu, J.L.2
Chung, T.M.3
-
18
-
-
0347927596
-
Measures used to lower building energy consumption and their cost effectiveness
-
Florides G.A., Tassou S.A., Kalogirou S.A., Wrobel L.C. Measures used to lower building energy consumption and their cost effectiveness. Appl Energy 2002, 73:299-328.
-
(2002)
Appl Energy
, vol.73
, pp. 299-328
-
-
Florides, G.A.1
Tassou, S.A.2
Kalogirou, S.A.3
Wrobel, L.C.4
-
19
-
-
33751097729
-
Application of overhangs and side fins to high-rise residential buildings in Hong Kong
-
Bojić M. Application of overhangs and side fins to high-rise residential buildings in Hong Kong. Civ Eng Environ Syst 2006, 23:271-285.
-
(2006)
Civ Eng Environ Syst
, vol.23
, pp. 271-285
-
-
Bojić, M.1
-
20
-
-
85017993831
-
Input output reference: the encyclopedic reference to EnergyPlus input and output
-
EnergyPlus Development Team Input output reference: the encyclopedic reference to EnergyPlus input and output. EnergyPlus Version 2013, 8.1.
-
(2013)
EnergyPlus Version
-
-
-
21
-
-
84929510863
-
-
BEAM Society Limited
-
BEAM Plus New Buildings Version 1.2 (2012.07) 2012, BEAM Society Limited.
-
(2012)
Version 1.2 (2012.07)
-
-
-
23
-
-
24944467894
-
Generation of a typical meteorological year for Hong Kong
-
Chan A.L.S., Chow T.T., Fong K.F., Lin Z. Generation of a typical meteorological year for Hong Kong. Energy Convers Manage 2006, 47:87-96.
-
(2006)
Energy Convers Manage
, vol.47
, pp. 87-96
-
-
Chan, A.L.S.1
Chow, T.T.2
Fong, K.F.3
Lin, Z.4
-
24
-
-
0032317897
-
Quantitative comparison of North American and U.K. cooling load calculation procedures - methodology
-
Rees S.J., Spitler J.D., Haves P. Quantitative comparison of North American and U.K. cooling load calculation procedures - methodology. ASHRAE Trans 1998, 104:36-46.
-
(1998)
ASHRAE Trans
, vol.104
, pp. 36-46
-
-
Rees, S.J.1
Spitler, J.D.2
Haves, P.3
-
25
-
-
84929505184
-
-
U.S. Department of Energy, Energy Efficiency and Renewable Energy, Office of Building Technologies, Washington D.C
-
EnergyPlus Testing with IEA BESTEST Multi-zone non-Airflow in-depth diagnostic cases MZ320 - MZ360 November 2013, U.S. Department of Energy, Energy Efficiency and Renewable Energy, Office of Building Technologies, Washington D.C.
-
(2013)
Multi-zone non-Airflow in-depth diagnostic cases MZ320 - MZ360
-
-
-
26
-
-
84864681948
-
-
National Renewable Energy Laboratory, Golden, Colorado
-
Neymark J., Judkoff R. International Energy Agency building energy simulation test and diagnostic method (IEA BESTEST) multi-zone non-airflow in-depth diagnostic cases: MZ320 - MZ360, NREL/TP-550-43827 September 2008, National Renewable Energy Laboratory, Golden, Colorado.
-
(2008)
International Energy Agency building energy simulation test and diagnostic method (IEA BESTEST) multi-zone non-airflow in-depth diagnostic cases: MZ320 - MZ360, NREL/TP-550-43827
-
-
Neymark, J.1
Judkoff, R.2
-
28
-
-
84885741940
-
Thermal performance of air-conditioned office buildings constructed with inclined walls in different climates in China
-
Chan A.L.S., Chow T.T. Thermal performance of air-conditioned office buildings constructed with inclined walls in different climates in China. Appl Energy 2014, 114:45-57.
-
(2014)
Appl Energy
, vol.114
, pp. 45-57
-
-
Chan, A.L.S.1
Chow, T.T.2
-
29
-
-
68049113386
-
Life cycle energy assessment of a typical office building in Thailand
-
Kofoworola O.F., Gheewala S.H. Life cycle energy assessment of a typical office building in Thailand. Energy Build 2009, 41:1076-1083.
-
(2009)
Energy Build
, vol.41
, pp. 1076-1083
-
-
Kofoworola, O.F.1
Gheewala, S.H.2
-
30
-
-
85018012941
-
-
Private communication with a local construction contractor.
-
-
-
-
34
-
-
85028222457
-
The nexus among employment opportunities, life-cycle costs, and carbon emissions: a case study of sustainable building maintenance in Hong Kong
-
Chiang Y.H., Li J., Zhou L., Wong F.K.W., Lam P.T.I. The nexus among employment opportunities, life-cycle costs, and carbon emissions: a case study of sustainable building maintenance in Hong Kong. J Clean Prod 2014, 1-10. http://dx.doi.org/10.1016/j.jclepro.2014.07.069.
-
(2014)
J Clean Prod
, pp. 1-10
-
-
Chiang, Y.H.1
Li, J.2
Zhou, L.3
Wong, F.K.W.4
Lam, P.T.I.5
|