메뉴 건너뛰기




Volumn 85, Issue , 2015, Pages 620-634

Investigation on the appropriate floor level of residential building for installing balcony, from a view point of energy and environmental performance. A case study in subtropical Hong Kong

Author keywords

Balcony; Building energy simulation; EnergyPlus; Environmental payback period; Solar shading

Indexed keywords

AIR CONDITIONING; ENVIRONMENTAL MANAGEMENT; FLOORS; HOUSING; INVESTMENTS;

EID: 84929510032     PISSN: 03605442     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.energy.2015.04.001     Document Type: Article
Times cited : (22)

References (34)
  • 1
    • 0742320773 scopus 로고    scopus 로고
    • Prediction of the sound field into high-rise building façades due to its balcony ceiling form
    • Dien H.H.E., Woloszyn P. Prediction of the sound field into high-rise building façades due to its balcony ceiling form. Appl Acoust 2004, 65:431-440.
    • (2004) Appl Acoust , vol.65 , pp. 431-440
    • Dien, H.H.E.1    Woloszyn, P.2
  • 2
    • 34249950920 scopus 로고    scopus 로고
    • Effects of apartment building façade and balcony design on the reduction of exterior noise
    • Lee P.J., Kim Y.H., Jeon J.Y., Song K.D. Effects of apartment building façade and balcony design on the reduction of exterior noise. Build Environ 2007, 42:3517-3528.
    • (2007) Build Environ , vol.42 , pp. 3517-3528
    • Lee, P.J.1    Kim, Y.H.2    Jeon, J.Y.3    Song, K.D.4
  • 3
    • 33748949926 scopus 로고    scopus 로고
    • Field measurements of façade sound insulation in residential buildings with balcony windows
    • Kim M.J., Kim H.G. Field measurements of façade sound insulation in residential buildings with balcony windows. Build Environ 2007, 42:1026-1035.
    • (2007) Build Environ , vol.42 , pp. 1026-1035
    • Kim, M.J.1    Kim, H.G.2
  • 4
    • 77955466558 scopus 로고    scopus 로고
    • Scale model study of balcony insertion losses on a building façade with non-parallel line sources
    • Tang S.K. Scale model study of balcony insertion losses on a building façade with non-parallel line sources. Appl Acoust 2010, 71:947-954.
    • (2010) Appl Acoust , vol.71 , pp. 947-954
    • Tang, S.K.1
  • 5
    • 84892857453 scopus 로고    scopus 로고
    • Simulating the effect of acoustic treatment types for residential balconies with road traffic noise
    • Naish D.A., Tan A.C.C., Demirbilek F.N. Simulating the effect of acoustic treatment types for residential balconies with road traffic noise. Appl Acoust 2014, 79:131-140.
    • (2014) Appl Acoust , vol.79 , pp. 131-140
    • Naish, D.A.1    Tan, A.C.C.2    Demirbilek, F.N.3
  • 6
    • 84856588893 scopus 로고    scopus 로고
    • Estimating health related costs and savings from balcony acoustic design for road traffic noise
    • Naish D.A., Tan A.C.C., Demirbilek F.N. Estimating health related costs and savings from balcony acoustic design for road traffic noise. Appl Acoust 2012, 73:497-507.
    • (2012) Appl Acoust , vol.73 , pp. 497-507
    • Naish, D.A.1    Tan, A.C.C.2    Demirbilek, F.N.3
  • 7
    • 84896891341 scopus 로고    scopus 로고
    • Associations between building characteristics and children's allergic symptoms - a cross-sectional study on child's health and home in Seoul, South Korea
    • Choi J., Chun C., Sun Y., Choi Y., Kwon S., Bornehag C.G., et al. Associations between building characteristics and children's allergic symptoms - a cross-sectional study on child's health and home in Seoul, South Korea. Build Environ 2014, 75:176-181.
    • (2014) Build Environ , vol.75 , pp. 176-181
    • Choi, J.1    Chun, C.2    Sun, Y.3    Choi, Y.4    Kwon, S.5    Bornehag, C.G.6
  • 8
    • 1542610617 scopus 로고    scopus 로고
    • A computational study on the use of balconies to reduce flame spread in high-rise apartment fires
    • Mammoser J.H., Battaglia F. A computational study on the use of balconies to reduce flame spread in high-rise apartment fires. Fire Saf 2004, 39:277-296.
    • (2004) Fire Saf , vol.39 , pp. 277-296
    • Mammoser, J.H.1    Battaglia, F.2
  • 9
    • 84881256930 scopus 로고    scopus 로고
    • CFD evaluation of new second-skin façade concept for wind comfort on building balconies: case study for the Park Tower in Antwerp
    • Montazeri H., Blocken B., Janssen W.D., van Hooff T. CFD evaluation of new second-skin façade concept for wind comfort on building balconies: case study for the Park Tower in Antwerp. Build Environ 2013, 68:179-192.
    • (2013) Build Environ , vol.68 , pp. 179-192
    • Montazeri, H.1    Blocken, B.2    Janssen, W.D.3    van Hooff, T.4
  • 10
    • 33746779349 scopus 로고    scopus 로고
    • Energy conservation effect of new HVAC system for condominiums with solar collectors integrated with the balcony handrail
    • Yoshie R., Satake A., Mochid A., Kato S., Yoshino H. Energy conservation effect of new HVAC system for condominiums with solar collectors integrated with the balcony handrail. Energy Build 2006, 38:1360-1367.
    • (2006) Energy Build , vol.38 , pp. 1360-1367
    • Yoshie, R.1    Satake, A.2    Mochid, A.3    Kato, S.4    Yoshino, H.5
  • 11
    • 84891404056 scopus 로고    scopus 로고
    • Thermal performance evaluation of fiber-reinforced polymer thermal breaks for balcony connections
    • Goulouti K., de Castro J., Vassilopoulos A.P., Keller T. Thermal performance evaluation of fiber-reinforced polymer thermal breaks for balcony connections. Energy Build 2014, 70:365-371.
    • (2014) Energy Build , vol.70 , pp. 365-371
    • Goulouti, K.1    de Castro, J.2    Vassilopoulos, A.P.3    Keller, T.4
  • 12
    • 84873935302 scopus 로고    scopus 로고
    • Impact of balcony thermal bridges on the overall thermal performance of multi-unit residential buildings: a case study
    • Ge H., McClung V.R., Zhang S. Impact of balcony thermal bridges on the overall thermal performance of multi-unit residential buildings: a case study. Energy Build 2013, 60:163-173.
    • (2013) Energy Build , vol.60 , pp. 163-173
    • Ge, H.1    McClung, V.R.2    Zhang, S.3
  • 13
    • 82355191619 scopus 로고    scopus 로고
    • Effect of building regulation on energy consumption in residential buildings in Korea
    • Song D., Choi Y.J. Effect of building regulation on energy consumption in residential buildings in Korea. Renew Sustain Energy Rev 2012, 16:1074-1081.
    • (2012) Renew Sustain Energy Rev , vol.16 , pp. 1074-1081
    • Song, D.1    Choi, Y.J.2
  • 14
    • 70350208805 scopus 로고    scopus 로고
    • Healthy-daylighting design for the living environment in apartments in Korea
    • Kim G., Kim J.T. Healthy-daylighting design for the living environment in apartments in Korea. Build Environ 2010, 45:287-294.
    • (2010) Build Environ , vol.45 , pp. 287-294
    • Kim, G.1    Kim, J.T.2
  • 16
    • 77957706941 scopus 로고    scopus 로고
    • Investigation on energy performance and energy payback period of application of balcony for residential apartment in Hong Kong
    • Chan A.L.S., Chow T.T. Investigation on energy performance and energy payback period of application of balcony for residential apartment in Hong Kong. Energy Build 2010, 42:2400-2405.
    • (2010) Energy Build , vol.42 , pp. 2400-2405
    • Chan, A.L.S.1    Chow, T.T.2
  • 17
    • 81855201725 scopus 로고    scopus 로고
    • Energy and carbon emission payback analysis for energy-efficient retrofitting in buildings - overhang shading option
    • Huang Y., Niu J.L., Chung T.M. Energy and carbon emission payback analysis for energy-efficient retrofitting in buildings - overhang shading option. Energy Build 2012, 44:94-103.
    • (2012) Energy Build , vol.44 , pp. 94-103
    • Huang, Y.1    Niu, J.L.2    Chung, T.M.3
  • 18
    • 0347927596 scopus 로고    scopus 로고
    • Measures used to lower building energy consumption and their cost effectiveness
    • Florides G.A., Tassou S.A., Kalogirou S.A., Wrobel L.C. Measures used to lower building energy consumption and their cost effectiveness. Appl Energy 2002, 73:299-328.
    • (2002) Appl Energy , vol.73 , pp. 299-328
    • Florides, G.A.1    Tassou, S.A.2    Kalogirou, S.A.3    Wrobel, L.C.4
  • 19
    • 33751097729 scopus 로고    scopus 로고
    • Application of overhangs and side fins to high-rise residential buildings in Hong Kong
    • Bojić M. Application of overhangs and side fins to high-rise residential buildings in Hong Kong. Civ Eng Environ Syst 2006, 23:271-285.
    • (2006) Civ Eng Environ Syst , vol.23 , pp. 271-285
    • Bojić, M.1
  • 20
    • 85017993831 scopus 로고    scopus 로고
    • Input output reference: the encyclopedic reference to EnergyPlus input and output
    • EnergyPlus Development Team Input output reference: the encyclopedic reference to EnergyPlus input and output. EnergyPlus Version 2013, 8.1.
    • (2013) EnergyPlus Version
  • 21
    • 84929510863 scopus 로고    scopus 로고
    • BEAM Society Limited
    • BEAM Plus New Buildings Version 1.2 (2012.07) 2012, BEAM Society Limited.
    • (2012) Version 1.2 (2012.07)
  • 23
  • 24
    • 0032317897 scopus 로고    scopus 로고
    • Quantitative comparison of North American and U.K. cooling load calculation procedures - methodology
    • Rees S.J., Spitler J.D., Haves P. Quantitative comparison of North American and U.K. cooling load calculation procedures - methodology. ASHRAE Trans 1998, 104:36-46.
    • (1998) ASHRAE Trans , vol.104 , pp. 36-46
    • Rees, S.J.1    Spitler, J.D.2    Haves, P.3
  • 25
    • 84929505184 scopus 로고    scopus 로고
    • U.S. Department of Energy, Energy Efficiency and Renewable Energy, Office of Building Technologies, Washington D.C
    • EnergyPlus Testing with IEA BESTEST Multi-zone non-Airflow in-depth diagnostic cases MZ320 - MZ360 November 2013, U.S. Department of Energy, Energy Efficiency and Renewable Energy, Office of Building Technologies, Washington D.C.
    • (2013) Multi-zone non-Airflow in-depth diagnostic cases MZ320 - MZ360
  • 28
    • 84885741940 scopus 로고    scopus 로고
    • Thermal performance of air-conditioned office buildings constructed with inclined walls in different climates in China
    • Chan A.L.S., Chow T.T. Thermal performance of air-conditioned office buildings constructed with inclined walls in different climates in China. Appl Energy 2014, 114:45-57.
    • (2014) Appl Energy , vol.114 , pp. 45-57
    • Chan, A.L.S.1    Chow, T.T.2
  • 29
    • 68049113386 scopus 로고    scopus 로고
    • Life cycle energy assessment of a typical office building in Thailand
    • Kofoworola O.F., Gheewala S.H. Life cycle energy assessment of a typical office building in Thailand. Energy Build 2009, 41:1076-1083.
    • (2009) Energy Build , vol.41 , pp. 1076-1083
    • Kofoworola, O.F.1    Gheewala, S.H.2
  • 30
    • 85018012941 scopus 로고    scopus 로고
    • Private communication with a local construction contractor.
  • 34
    • 85028222457 scopus 로고    scopus 로고
    • The nexus among employment opportunities, life-cycle costs, and carbon emissions: a case study of sustainable building maintenance in Hong Kong
    • Chiang Y.H., Li J., Zhou L., Wong F.K.W., Lam P.T.I. The nexus among employment opportunities, life-cycle costs, and carbon emissions: a case study of sustainable building maintenance in Hong Kong. J Clean Prod 2014, 1-10. http://dx.doi.org/10.1016/j.jclepro.2014.07.069.
    • (2014) J Clean Prod , pp. 1-10
    • Chiang, Y.H.1    Li, J.2    Zhou, L.3    Wong, F.K.W.4    Lam, P.T.I.5


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.