메뉴 건너뛰기




Volumn 34, Issue 5, 2015, Pages 1077-1084

Magnetic particle imaging with tailored iron oxide nanoparticle tracers

Author keywords

Biomedical imaging; magnetic particle imaging; Superparamagnetic iron oxides

Indexed keywords

BIOCOMPATIBILITY; IMAGING TECHNIQUES; IRON OXIDES; MAGNETIC RESONANCE IMAGING; MAGNETISM; MATERIALS PROPERTIES; NANOMAGNETICS; NANOPARTICLES; SIGNAL TO NOISE RATIO;

EID: 84929457560     PISSN: 02780062     EISSN: 1558254X     Source Type: Journal    
DOI: 10.1109/TMI.2014.2375065     Document Type: Article
Times cited : (185)

References (42)
  • 1
    • 21744445797 scopus 로고    scopus 로고
    • Tomographic imaging using the nonlinear response of magnetic particles
    • Jul.
    • B. Gleich and J. Weizenecker, "Tomographic imaging using the nonlinear response of magnetic particles, " Nature, vol. 435, no. 7046, pp. 1214-1217, Jul. 2005.
    • (2005) Nature , vol.435 , Issue.7046 , pp. 1214-1217
    • Gleich, B.1    Weizenecker, J.2
  • 3
    • 77953853621 scopus 로고    scopus 로고
    • Biomedical nanomagnetics: A spin through possibilities in imaging, diagnostics, and therapy
    • Jun.
    • K. M. Krishnan, "Biomedical nanomagnetics: A spin through possibilities in imaging, diagnostics, and therapy, " IEEE Trans. Magn., vol. 46, no. 7, pp. 2523-2558, Jun. 2010.
    • (2010) IEEE Trans. Magn. , vol.46 , Issue.7 , pp. 2523-2558
    • Krishnan, K.M.1
  • 4
    • 63649121948 scopus 로고    scopus 로고
    • Three-dimensional real-time in vivo magnetic particle imaging
    • J. Weizenecker, B. Gleich, J. Rahmer, H. Dahnke, and J. Borgert, "Three-dimensional real-time in vivo magnetic particle imaging, " Phys. Med. Biol., vol. 54, no. 5, pp. L1-L10, 2009.
    • (2009) Phys. Med. Biol. , vol.54 , Issue.5 , pp. L1-L10
    • Weizenecker, J.1    Gleich, B.2    Rahmer, J.3    Dahnke, H.4    Borgert, J.5
  • 5
    • 36048972710 scopus 로고    scopus 로고
    • A simulation study on the resolution and sensitivity of magnetic particle imaging
    • J. Weizenecker, J. Borgert, and B. Gleich, "A simulation study on the resolution and sensitivity of magnetic particle imaging, " Phys. Med. Biol., vol. 52, pp. 6363-6374, 2007.
    • (2007) Phys. Med. Biol. , vol.52 , pp. 6363-6374
    • Weizenecker, J.1    Borgert, J.2    Gleich, B.3
  • 6
    • 33646128258 scopus 로고    scopus 로고
    • Contrast-induced nephrotoxicity: Clinical landscape
    • Apr.
    • R. W. Katzberg and C. Haller, "Contrast-induced nephrotoxicity: Clinical landscape, " Kidney Int., vol. 69, pp. S3-S7, Apr. 2006.
    • (2006) Kidney Int. , vol.69 , pp. S3-S7
    • Katzberg, R.W.1    Haller, C.2
  • 8
    • 84929498197 scopus 로고    scopus 로고
    • Atlas of chronic kidney disease in the United States
    • USRDS Annu. Data Rep. 2012, vol. 1, Atlas of chronic kidney disease in the United States.
    • (2012) Data Rep. , vol.1
    • Usrds, A.1
  • 9
    • 77951619720 scopus 로고    scopus 로고
    • FDA report: Ferumoxytol for intravenous iron therapy in adult patients with chronic kidney disease
    • M. Lu, M. H. Cohen, D. Rieves, and R. Pazdur, "FDA report: Ferumoxytol for intravenous iron therapy in adult patients with chronic kidney disease, " Am. J. Hematol., pp. 315-319.
    • Am. J. Hematol. , pp. 315-319
    • Lu, M.1    Cohen, M.H.2    Rieves, D.3    Pazdur, R.4
  • 10
    • 60749086794 scopus 로고    scopus 로고
    • Ultrasmall superparamagnetic iron oxides (USPIOs): A future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF)
    • E. A. Neuwelt et al., "Ultrasmall superparamagnetic iron oxides (USPIOs): A future alternative magnetic resonance (MR) contrast agent for patients at risk for nephrogenic systemic fibrosis (NSF), " Kidney Int., vol. 75, no. 5, pp. 465-474, 2009.
    • (2009) Kidney Int. , vol.75 , Issue.5 , pp. 465-474
    • Neuwelt, E.A.1
  • 11
    • 84874958524 scopus 로고    scopus 로고
    • Monodisperse magnetite nanoparticle tracers for in vivo magnetic particle imaging
    • Feb.
    • A. P. Khandhar, R. M. Ferguson, H. Arami, and K. M. Krishnan, "Monodisperse magnetite nanoparticle tracers for in vivo magnetic particle imaging, " Biomaterials, vol. 34, pp. 3837-3845, Feb. 2013.
    • (2013) Biomaterials , vol.34 , pp. 3837-3845
    • Khandhar, A.P.1    Ferguson, R.M.2    Arami, H.3    Krishnan, K.M.4
  • 12
    • 33746897305 scopus 로고    scopus 로고
    • Magnetic resonance imaging of experimental atherosclerotic plaque: Comparison of two ultrasmall superparamagnetic particles of iron oxide
    • C. U. Herborn, F. M. Vogt, T. C. Lauenstein, O. Dirsch, C. Corot, P. Robert, and S. G. Ruehm, "Magnetic resonance imaging of experimental atherosclerotic plaque: Comparison of two ultrasmall superparamagnetic particles of iron oxide, " J. Magn. Reson. Imag., vol. 24, no. 2, pp. 388-393, 2006.
    • (2006) J. Magn. Reson. Imag. , vol.24 , Issue.2 , pp. 388-393
    • Herborn, C.U.1    Vogt, F.M.2    Lauenstein, T.C.3    Dirsch, O.4    Corot, C.5    Robert, P.6    Ruehm, S.G.7
  • 13
    • 68149172455 scopus 로고    scopus 로고
    • In vivo MRI cell tracking: Clinical studies
    • Aug.
    • J. W. M. Bulte, "In vivo MRI cell tracking: Clinical studies, " Am J. Roentgenol., vol. 193, no. 2, pp. 314-325, Aug. 2009.
    • (2009) Am J. Roentgenol. , vol.193 , Issue.2 , pp. 314-325
    • Bulte, J.W.M.1
  • 16
    • 64249158650 scopus 로고    scopus 로고
    • Optimization of nanoparticle core size for magnetic particle imaging
    • R. Ferguson, K. Minard, and K. Krishnan, "Optimization of nanoparticle core size for magnetic particle imaging, " J. Magn. Magn. Mater., vol. 321, pp. 1548-1551, 2009.
    • (2009) J. Magn. Magn. Mater. , vol.321 , pp. 1548-1551
    • Ferguson, R.1    Minard, K.2    Krishnan, K.3
  • 17
    • 78149248339 scopus 로고    scopus 로고
    • The-space formulation of the magnetic particle imaging process: 1-D signal, resolution, bandwidth, SNR, SAR, and magnetostimulation
    • Nov.
    • P. W. Goodwill and S. M. Conolly, "The-space formulation of the magnetic particle imaging process: 1-D signal, resolution, bandwidth, SNR, SAR, and magnetostimulation, " IEEE Trans. Med. Imag., vol. 29, no. 11, pp. 1851-1859, Nov. 2010.
    • (2010) IEEE Trans. Med. Imag. , vol.29 , Issue.11 , pp. 1851-1859
    • Goodwill, P.W.1    Conolly, S.M.2
  • 18
    • 84883400151 scopus 로고    scopus 로고
    • Linearity and shift invariance for quantitative magnetic particle imaging
    • Sep.
    • K. Lu, P. W. Goodwill, E. U. Saritas, B. Zheng, and S. M. Conolly, "Linearity and shift invariance for quantitative magnetic particle imaging, " IEEE Trans. Med. Imag., vol. 32, no. 9, pp. 1565-1575, Sep. 2013.
    • (2013) IEEE Trans. Med. Imag. , vol.32 , Issue.9 , pp. 1565-1575
    • Lu, K.1    Goodwill, P.W.2    Saritas, E.U.3    Zheng, B.4    Conolly, S.M.5
  • 19
    • 79952143878 scopus 로고    scopus 로고
    • Optimizing magnetite nanoparticles for mass sensitivity in magnetic particle imaging
    • Feb.
    • R. M. Ferguson, K. R. Minard, A. P. Khandhar, and K. M. Krishnan, "Optimizing magnetite nanoparticles for mass sensitivity in magnetic particle imaging, " Med. Phys., vol. 38, no. 3, pp. 1619-1626, Feb. 2011.
    • (2011) Med. Phys. , vol.38 , Issue.3 , pp. 1619-1626
    • Ferguson, R.M.1    Minard, K.R.2    Khandhar, A.P.3    Krishnan, K.M.4
  • 20
    • 84861752375 scopus 로고    scopus 로고
    • Tracer design for magnetic particle imaging (invited)
    • R. M. Ferguson, A. P. Khandhar, and K. M. Krishnan, "Tracer design for magnetic particle imaging (invited), " J. Appl. Phys., vol. 111, no. 7, p. 07B318, 2012.
    • (2012) J. Appl. Phys. , vol.111 , Issue.7 , pp. 07B318
    • Ferguson, R.M.1    Khandhar, A.P.2    Krishnan, K.M.3
  • 22
    • 77956364081 scopus 로고    scopus 로고
    • Generation of a static magnetic field-free line using two Maxwell coil pairs
    • 2010
    • T. Knopp, M. Erbe, T. F. Sattel, S. Biederer, and T. M. Buzug, "Generation of a static magnetic field-free line using two Maxwell coil pairs, " Appl. Phys. Lett., vol. 97, no. 9, pp. 092505-092505, 2010.
    • Appl. Phys. Lett. , vol.97 , Issue.9 , pp. 092505-092505
    • Knopp, T.1    Erbe, M.2    Sattel, T.F.3    Biederer, S.4    Buzug, T.M.5
  • 23
    • 80052413963 scopus 로고    scopus 로고
    • Experimental generation of an arbitrarily rotated field-free line for the use in magnetic particle imaging
    • 2011
    • M. Erbe, T. Knopp, T. F. Sattel, S. Biederer, and T. M. Buzug, "Experimental generation of an arbitrarily rotated field-free line for the use in magnetic particle imaging, " Med. Phys., vol. 38, no. 9, p. 5200, 2011.
    • Med. Phys. , vol.38 , Issue.9 , pp. 5200
    • Erbe, M.1    Knopp, T.2    Sattel, T.F.3    Biederer, S.4    Buzug, T.M.5
  • 25
    • 84890469899 scopus 로고    scopus 로고
    • On the formulation of the image reconstruction problem in magnetic particle imaging
    • M. Grüttner et al., "On the formulation of the image reconstruction problem in magnetic particle imaging, " Biomed. Tech. (Berl.), vol. 58, no. 6, pp. 583-91.
    • Biomed. Tech. (Berl.) , vol.58 , Issue.6 , pp. 583-591
    • Grüttner, M.1
  • 26
    • 66149168708 scopus 로고    scopus 로고
    • Signal encoding in magnetic particle imaging: Properties of the system function
    • J. Rahmer, J. Weizenecker, B. Gleich, and J. Borgert, "Signal encoding in magnetic particle imaging: Properties of the system function, " BMC Med. Imag., vol. 9, p. 4, 2009.
    • (2009) BMC Med. Imag. , vol.9 , pp. 4
    • Rahmer, J.1    Weizenecker, J.2    Gleich, B.3    Borgert, J.4
  • 27
    • 84861896301 scopus 로고    scopus 로고
    • Analysis of a 3-D system function measured for magnetic particle imaging
    • Jun.
    • J. Rahmer, J. Weizenecker, B. Gleich, and J. Borgert, "Analysis of a 3-D system function measured for magnetic particle imaging, " IEEE Trans. Med. Imag., vol. 31, no. 6, pp. 1289-1299, Jun. 2012.
    • (2012) IEEE Trans. Med. Imag. , vol.31 , Issue.6 , pp. 1289-1299
    • Rahmer, J.1    Weizenecker, J.2    Gleich, B.3    Borgert, J.4
  • 29
    • 80052295871 scopus 로고    scopus 로고
    • Multidimensional-space magnetic particle imaging
    • Sep.
    • P. Goodwill and S. Conolly, "Multidimensional-space magnetic particle imaging, " IEEE Trans.Med. Imag., vol. 30, no. 9, pp. 1581-1590, Sep. 2011.
    • (2011) IEEE Trans.Med. Imag. , vol.30 , Issue.9 , pp. 1581-1590
    • Goodwill, P.1    Conolly, S.2
  • 31
    • 84856221127 scopus 로고    scopus 로고
    • Tailored magnetic nanoparticles for optimizing magnetic fluid hyperthermia
    • A. P. Khandhar, R. M. Ferguson, J. A. Simon, and K. M. Krishnan, "Tailored magnetic nanoparticles for optimizing magnetic fluid hyperthermia, " J. Biomed. Mater. Res. Part A, vol. 100, no. 3, pp. 728-737, 2012.
    • (2012) J. Biomed. Mater. Res. Part A , vol.100 , Issue.3 , pp. 728-737
    • Khandhar, A.P.1    Ferguson, R.M.2    Simon, J.A.3    Krishnan, K.M.4
  • 32
    • 84890539234 scopus 로고    scopus 로고
    • Point spread function analysis of magnetic particles
    • T. M. Buzug and J. Borgert, Eds. Berlin, Germnay: Springer
    • I. Schmale, J. Rhamer, B. Gleich, J. Borgert, and J. Weizenecker, "Point spread function analysis of magnetic particles, " in Springer Proceedings in Physics, T. M. Buzug and J. Borgert, Eds. Berlin, Germnay: Springer, 2012, vol. 140, pp. 287-292.
    • (2012) Springer Proceedings in Physics , vol.140 , pp. 287-292
    • Schmale, I.1    Rhamer, J.2    Gleich, B.3    Borgert, J.4    Weizenecker, J.5
  • 36
    • 84870250138 scopus 로고    scopus 로고
    • System calibration unit for magnetic particle imaging: Focus field based system function
    • T. M. Buzug and J. Borgert, Eds. Berlin, Germany: Springer
    • A. Halkola, T. Buzug, J. Rahmer, and B. Gleich, "System calibration unit for magnetic particle imaging: Focus field based system function, " in Springer Proceedings in Physics, T. M. Buzug and J. Borgert, Eds. Berlin, Germany: Springer, 2012, vol. 140, pp. 27-31.
    • (2012) Springer Proceedings in Physics , vol.140 , pp. 27-31
    • Halkola, A.1    Buzug, T.2    Rahmer, J.3    Gleich, B.4
  • 37
    • 84883320569 scopus 로고    scopus 로고
    • Third generation-space MPI mouse and rat scanner
    • T. M. Buzug and J. Borgert, Eds. Berlin, Germany: Springer
    • P. Goodwill, L. R. Croft, J. Konkle, K. Lu, E. U. Saritas, B. Zheng, and S. Conolly, "Third generation-space MPI mouse and rat scanner, " in Springer Proceedings in Physics, T. M. Buzug and J. Borgert, Eds. Berlin, Germany: Springer, 2012, vol. 140, pp. 261-265.
    • (2012) Springer Proceedings in Physics , vol.140 , pp. 261-265
    • Goodwill, P.1    Croft, L.R.2    Konkle, J.3    Lu, K.4    Saritas, E.U.5    Zheng, B.6    Conolly, S.7
  • 38
    • 84861645819 scopus 로고    scopus 로고
    • An-space magnetic particle imaging scanner
    • P. W. Goodwill, K. Lu, B. Zheng, and S. M. Conolly, "An-space magnetic particle imaging scanner, " Rev. Sci. Instrum., vol. 83, no. 3, p. 033708, 2012.
    • (2012) Rev. Sci. Instrum. , vol.83 , Issue.3 , pp. 033708
    • Goodwill, P.W.1    Lu, K.2    Zheng, B.3    Conolly, S.M.4
  • 39
    • 79957478087 scopus 로고    scopus 로고
    • How the size distribution of magnetic nanoparticles determines their magnetic particle imaging performance
    • D. Eberbeck, F. Wiekhorst, S. Wagner, and L. Trahms, "How the size distribution of magnetic nanoparticles determines their magnetic particle imaging performance, " Appl. Phys. Lett., vol. 98, no. 18, p. 182502, 2011.
    • (2011) Appl. Phys. Lett. , vol.98 , Issue.18 , pp. 182502
    • Eberbeck, D.1    Wiekhorst, F.2    Wagner, S.3    Trahms, L.4
  • 41
    • 84890521167 scopus 로고    scopus 로고
    • Tailoring the magnetic and pharmacokinetic properties of iron oxide magnetic particle imaging tracers
    • Dec.
    • R. M. Ferguson, A. P. Khandhar, H. Arami, L. Hua, O. Hovorka, and K. M. Krishnan, "Tailoring the magnetic and pharmacokinetic properties of iron oxide magnetic particle imaging tracers, " Biomed. Tech. (Berl.), vol. 58, no. 6, pp. 493-507, Dec. 2013.
    • (2013) Biomed. Tech. (Berl.) , vol.58 , Issue.6 , pp. 493-507
    • Ferguson, R.M.1    Khandhar, A.P.2    Arami, H.3    Hua, L.4    Hovorka, O.5    Krishnan, K.M.6
  • 42
    • 84869065665 scopus 로고    scopus 로고
    • Micro-magnetic simulation study on the magnetic particle imaging performance of anisotropic mono-domain particles
    • Oct.
    • J. Weizenecker, B. Gleich, J. Rahmer, and J. Borgert, "Micro-magnetic simulation study on the magnetic particle imaging performance of anisotropic mono-domain particles, " Phys. Med. Biol., vol. 57, no. 22, pp. 7317-7327, Oct. 2012.
    • (2012) Phys. Med. Biol. , vol.57 , Issue.22 , pp. 7317-7327
    • Weizenecker, J.1    Gleich, B.2    Rahmer, J.3    Borgert, J.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.