메뉴 건너뛰기




Volumn , Issue , 2014, Pages

The effect of PV on transformer ageing: University of Queensland's experience

Author keywords

paper insulation; photovoltaic systems; power system harmonics; power transformers; remaining life assessment

Indexed keywords

HARMONIC ANALYSIS; PHOTOVOLTAIC CELLS; POWER TRANSFORMERS;

EID: 84929427840     PISSN: None     EISSN: None     Source Type: Conference Proceeding    
DOI: 10.1109/AUPEC.2014.6966484     Document Type: Conference Paper
Times cited : (15)

References (19)
  • 1
    • 84929445186 scopus 로고    scopus 로고
    • Impact of high PV penetration on distribution transformer life time
    • Canada
    • H. Pezeshki and P. Wolfs, "Impact of High PV Penetration on Distribution Transformer Life Time", IEEE Int. Symp. On Electrical Insulation, pp. 408-411, Canada, 2006.
    • (2006) IEEE Int. Symp. on Electrical Insulation , pp. 408-411
    • Pezeshki, H.1    Wolfs, P.2
  • 3
    • 84872138792 scopus 로고    scopus 로고
    • Ageing rate of paper insulation used in power transformers. Part 1: Oil/paper system with low oxygen concentration
    • N. Lelekakis, D. Martin, and J. Wijaya, "Ageing rate of paper insulation used in power transformers. Part 1: oil/paper system with low oxygen concentration", IEEE Trans. Dielectr. Electr. Insul., Vol. 19, pp. 1999-2008, 2012.
    • (2012) IEEE Trans. Dielectr. Electr. Insul. , vol.19 , pp. 1999-2008
    • Lelekakis, N.1    Martin, D.2    Wijaya, J.3
  • 4
    • 84872159221 scopus 로고    scopus 로고
    • Ageing rate of paper insulation used in power transformers. Part 2: Oil/paper system with medium and high oxygen concentration
    • N. Lelekakis, D. Martin, and J. Wijaya, "Ageing rate of paper insulation used in power transformers. Part 2: oil/paper system with medium and high oxygen concentration", IEEE Trans. Dielectr. Electr. Insul., Vol. 19, pp. 2009-2018, 2012.
    • (2012) IEEE Trans. Dielectr. Electr. Insul. , vol.19 , pp. 2009-2018
    • Lelekakis, N.1    Martin, D.2    Wijaya, J.3
  • 5
    • 0009562258 scopus 로고
    • The behaviour of cellulose in mineral acid solutions: Kinetic study of the decomposition of cellulose in acid solutions
    • A. Ekenstam, "The behaviour of cellulose in mineral acid solutions: kinetic study of the decomposition of cellulose in acid solutions", Berichte der deutschen chemischen Gesellschaft, Vol. 69, pp. 553-559, 1936.
    • (1936) Berichte der Deutschen Chemischen Gesellschaft , vol.69 , pp. 553-559
    • Ekenstam, A.1
  • 6
    • 0002777838 scopus 로고
    • Kinetics and mechanisms of the lowtemperature degradation of cellulose
    • A. M. Emsley and G. C. Stevens, "Kinetics and mechanisms of the lowtemperature degradation of cellulose", Cellulose, Vol. 1, pp. 26-56, 1994.
    • (1994) Cellulose , vol.1 , pp. 26-56
    • Emsley, A.M.1    Stevens, G.C.2
  • 10
    • 84929409361 scopus 로고    scopus 로고
    • A research of harmonics for multiple PV inverters in grid-connected
    • China
    • Z. Xiangyang and L. Shiyang, "A Research of Harmonics for Multiple PV Inverters in Grid-Connected", Power and Energy Engineering Conference, pp. 1-4, China, 2012.
    • (2012) Power and Energy Engineering Conference , pp. 1-4
    • Xiangyang, Z.1    Shiyang, L.2
  • 17
    • 33750098137 scopus 로고    scopus 로고
    • Harmonic analysis in a power system with wind generation
    • S. Papathanassiou and M. Papadopoulos, "Harmonic Analysis in a Power System with Wind Generation", IEEE Transactions on Power Delivery, Vol. 21, Iss. 4, pp. 2006-2016, 2006.
    • (2006) IEEE Transactions on Power Delivery , vol.21 , Issue.4 , pp. 2006-2016
    • Papathanassiou, S.1    Papadopoulos, M.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.