메뉴 건너뛰기




Volumn 19, Issue 3, 2015, Pages 784-793

A bendable and wearable cardiorespiratory monitoring device fusing two noncontact sensor principles

Author keywords

Noncontactmonitoring; Pulse; Respiration; Sensor fusion; Wearable sensors

Indexed keywords

PATIENT MONITORING; PHYSIOLOGICAL MODELS;

EID: 84929301420     PISSN: 21682194     EISSN: 21682208     Source Type: Journal    
DOI: 10.1109/JBHI.2015.2417760     Document Type: Article
Times cited : (38)

References (14)
  • 1
    • 84880895284 scopus 로고    scopus 로고
    • Noncontact monitoring of cardiorespiratory activity by electromagnetic coupling
    • Aug.
    • D. Teichmann, J. Foussier, J. Jia, S. Leonhardt, and M. Walter, "Noncontact monitoring of cardiorespiratory activity by electromagnetic coupling", IEEE Trans. Biomed. Eng., vol. 60, no. 8, pp. 2142-2152, Aug. 2013.
    • (2013) IEEE Trans. Biomed. Eng. , vol.60 , Issue.8 , pp. 2142-2152
    • Teichmann, D.1    Foussier, J.2    Jia, J.3    Leonhardt, S.4    Walter, M.5
  • 2
    • 0007096418 scopus 로고
    • Electronic device for physiological kinetic measurements and detection of extraneous bodies
    • Jan.
    • R. Vas, "Electronic device for physiological kinetic measurements and detection of extraneous bodies", IEEE Trans. Biomed. Eng., vol. BME-14, no. 1, pp. 2-6, Jan. 1967.
    • (1967) IEEE Trans. Biomed. Eng. , vol.BME-14 , Issue.1 , pp. 2-6
    • Vas, R.1
  • 3
    • 0019728677 scopus 로고
    • Physical principles of the displacement cardiograph including a new device sensitive to variations in torso resistivity
    • Oct.
    • D. L. Wilson and D. B. Geselowitz, "Physical principles of the displacement cardiograph including a new device sensitive to variations in torso resistivity", IEEE Trans. Biomed. Eng., vol. BME-28, no. 10, pp. 702-710, Oct. 1981.
    • (1981) IEEE Trans. Biomed. Eng. , vol.BME-28 , Issue.10 , pp. 702-710
    • Wilson, D.L.1    Geselowitz, D.B.2
  • 4
    • 0014340443 scopus 로고
    • Electrodeless measurements of the effective resistivity of the human torso and head by magnetic induction
    • Oct.
    • P. P. Tarjan and R. McFee, "Electrodeless measurements of the effective resistivity of the human torso and head by magnetic induction", IEEE Trans. Biomed. Eng., vol. BME-15, no. 4, pp. 266-278, Oct. 1968.
    • (1968) IEEE Trans. Biomed. Eng. , vol.BME-15 , Issue.4 , pp. 266-278
    • Tarjan, P.P.1    McFee, R.2
  • 5
    • 0026128984 scopus 로고
    • Noninvasive detection of ventricular wall motion by electromagnetic coupling: Part 2: Experimental
    • M. G. Pepper, D. J. E. Taylor, and M. C. Kwok, "Noninvasive detection of ventricular wall motion by electromagnetic coupling: Part 2: Experimental", Med. Biol. Eng. Comput., vol. 29, no. 2, pp. 141-148, 1991.
    • (1991) Med. Biol. Eng. Comput. , vol.29 , Issue.2 , pp. 141-148
    • Pepper, M.G.1    Taylor, D.J.E.2    Kwok, M.C.3
  • 7
    • 77954672844 scopus 로고    scopus 로고
    • Model of an inductive sensor of cardiac activity attached to patient
    • J. Vedru and R. Gordon, "Model of an inductive sensor of cardiac activity attached to patient", J. Phys., Conf. Ser., vol. 224, 2010, doi: 10.1088/1742-6596/224/1/012010.
    • (2010) J. Phys., Conf. Ser. , vol.224
    • Vedru, J.1    Gordon, R.2
  • 8
    • 84892143930 scopus 로고    scopus 로고
    • The MAIN shirt: A textile-integrated magnetic induction sensor array
    • D. Teichmann, A. Kuhn, S. Leonhardt, and M. Walter, "The MAIN shirt: A textile-integrated magnetic induction sensor array", Sensors, vol. 14, no. 1, pp. 1039-1056, 2014.
    • (2014) Sensors , vol.14 , Issue.1 , pp. 1039-1056
    • Teichmann, D.1    Kuhn, A.2    Leonhardt, S.3    Walter, M.4
  • 10
    • 84861724400 scopus 로고    scopus 로고
    • A wireless reflectance pulse oximeter with digital baseline control for unfiltered photoplethysmograms
    • Jun.
    • K. Li and S. Warren, "A wireless reflectance pulse oximeter with digital baseline control for unfiltered photoplethysmograms", IEEE Trans. Biomed. Circuits Syst., vol. 6, no. 3, pp. 269-278, Jun. 2012.
    • (2012) IEEE Trans. Biomed. Circuits Syst. , vol.6 , Issue.3 , pp. 269-278
    • Li, K.1    Warren, S.2
  • 11
    • 84862752804 scopus 로고    scopus 로고
    • Advances in reflective oxygen saturation monitoring with a novel in-ear sensor system: Results of a human hypoxia study
    • Jul
    • B. Venema, N. Blanik, V. Blazek, H. Gehring, A. Opp, and S. Leonhardt, "Advances in reflective oxygen saturation monitoring with a novel in-ear sensor system: Results of a human hypoxia study", IEEE Trans. Biomed. Eng., vol. 59, no. 7, pp. 2003-2010, Jul. 2012.
    • (2012) IEEE Trans. Biomed. Eng. , vol.59 , Issue.7 , pp. 2003-2010
    • Venema, B.1    Blanik, N.2    Blazek, V.3    Gehring, H.4    Opp, A.5    Leonhardt, S.6
  • 12
    • 84905989353 scopus 로고    scopus 로고
    • A bendable and wearable cardiorespiratory monitoring device fusing two noncontact sensor principles
    • Zurich, Switzerland, Jun. 16-20
    • D. Teichmann, D. D. Matteis, M. Walter, and S. Leonhardt, "A bendable and wearable cardiorespiratory monitoring device fusing two noncontact sensor principles", in Proc. 11th Int. Conf. Wearable Implantable Body Sensor Netw., Zurich, Switzerland, Jun. 16-20, 2014, pp. 58-63.
    • (2014) Proc. 11th Int. Conf. Wearable Implantable Body Sensor Netw. , pp. 58-63
    • Teichmann, D.1    Matteis, D.D.2    Walter, M.3    Leonhardt, S.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.