2
-
-
0023442646
-
Standardization of spirometry - 1987 update
-
Statement of the American Thoracic Society
-
Standardization of spirometry - 1987 update. Statement of the American Thoracic Society. Am Rev Respir Dis 1987; 136: 1285-1298.
-
(1987)
Am Rev Respir Dis
, vol.136
, pp. 1285-1298
-
-
-
3
-
-
0029090616
-
Standardization of spirometry, 1994 update
-
American Thoracic Society
-
Standardization of spirometry, 1994 update. American Thoracic Society. Am J Respir Crit Care Med 1995; 152: 1107-1136.
-
(1995)
Am J Respir Crit Care Med
, vol.152
, pp. 1107-1136
-
-
-
5
-
-
0025810969
-
Spirometry in the lung health study. 1. Methods and quality control
-
Enright PL, Johnson LR, Connett JE, et al. Spirometry in the Lung Health Study. 1. Methods and quality control. Am Rev Respir Dis 1991; 143: 1215-1223.
-
(1991)
Am Rev Respir Dis
, vol.143
, pp. 1215-1223
-
-
Enright, P.L.1
Johnson, L.R.2
Connett, J.E.3
-
6
-
-
0041328560
-
How to make sure your spirometry tests are of good quality
-
Enright PL. How to make sure your spirometry tests are of good quality. Respir Care 2003; 48: 773-776.
-
(2003)
Respir Care
, vol.48
, pp. 773-776
-
-
Enright, P.L.1
-
7
-
-
0242623974
-
Office spirometry for lung health assessment in adults: A consensus statement from the national lung health education program
-
Ferguson GT, Enright PL, Buist AS, et al. Office spirometry for lung health assessment in adults: A consensus statement from the National Lung Health Education Program. Chest 2000; 117: 1146-1161.
-
(2000)
Chest
, vol.117
, pp. 1146-1161
-
-
Ferguson, G.T.1
Enright, P.L.2
Buist, A.S.3
-
8
-
-
34248580612
-
Peak expiratory flow is not a quality indicator for spirometry: Peak expiratory flow variability and FEV1 are poorly correlated in an elderly population
-
Hegewald MJ, Lefor MJ, Jensen RL, et al. Peak expiratory flow is not a quality indicator for spirometry: peak expiratory flow variability and FEV1 are poorly correlated in an elderly population. Chest 2007; 131: 1494-1499.
-
(2007)
Chest
, vol.131
, pp. 1494-1499
-
-
Hegewald, M.J.1
Lefor, M.J.2
Jensen, R.L.3
-
9
-
-
0013929866
-
Effect of thoracic gas compression on the flow-volume curve of the forced vital capacity
-
Ingram RH, Schilder DP. Effect of thoracic gas compression on the flow-volume curve of the forced vital capacity. Am Rev Respir Dis 1966; 94: 56-63.
-
(1966)
Am Rev Respir Dis
, vol.94
, pp. 56-63
-
-
Ingram, R.H.1
Schilder, D.P.2
-
10
-
-
58149332027
-
Mesure de la capacité vitale et des débits maximaux
-
Denolin H, Sadoul P, Orie NGM, eds., 2me partie. Paris, Flammarion
-
Sadoul P. Mesure de la capacité vitale et des débits maximaux. In: Denolin H, Sadoul P, Orie NGM, eds. L'exploration fonctionnelle pulmonaire, 2me partie. Paris, Flammarion, 1971.
-
(1971)
L'exploration Fonctionnelle Pulmonaire
-
-
Sadoul, P.1
-
11
-
-
13344272625
-
Airway dynamics during forced expiration in patients with chronic obstructive lung disease
-
Orie NGM, Van der Lende R, eds. Assen, Royal Van Gorcum
-
Van de Woestijne KP, Afschrift M. Airway dynamics during forced expiration in patients with chronic obstructive lung disease. In: Orie NGM, Van der Lende R, eds. Bronchitis III. Assen, Royal Van Gorcum, 1970; pp. 195-206.
-
(1970)
Bronchitis III
, pp. 195-206
-
-
Van De Woestijne, K.P.1
Afschrift, M.2
-
12
-
-
0023581676
-
Effect of effort on measurement of forced expiratory volume in one second
-
Krowka MJ, Enright PL, Rodarte JR, et al. Effect of effort on measurement of forced expiratory volume in one second. Am Rev Respir Dis 1987; 136: 829-833.
-
(1987)
Am Rev Respir Dis
, vol.136
, pp. 829-833
-
-
Krowka, M.J.1
Enright, P.L.2
Rodarte, J.R.3
-
13
-
-
84899875245
-
LUNOKID: Can numerical American Thoracic Society/European Respiratory Society quality criteria replace visual inspection of spirometry?
-
Müller-Brandes C, Krämer U, Gappa M, et al. LUNOKID: Can numerical American Thoracic Society/European Respiratory Society quality criteria replace visual inspection of spirometry? Eur Respir J 2014; 43: 1347-1356.
-
(2014)
Eur Respir J
, vol.43
, pp. 1347-1356
-
-
Müller-Brandes, C.1
Krämer, U.2
Gappa, M.3
-
15
-
-
77949372183
-
Quality of spirometry performed by 13, 599 participants in the world trade center worker and volunteer medical screening program
-
Enright PL, Skloot GS, Cox-Ganser JM, et al. Quality of spirometry performed by 13, 599 participants in the World Trade Center Worker and Volunteer Medical Screening Program. Respir Care 2010; 55: 303-309.
-
(2010)
Respir Care
, vol.55
, pp. 303-309
-
-
Enright, P.L.1
Skloot, G.S.2
Cox-Ganser, J.M.3
-
16
-
-
0033829948
-
FEV6 is an acceptable surrogate for FVC in the spirometric diagnosis of airway obstruction and restriction
-
Swanney MP, Jensen RL, Crichton DA, et al. FEV6 is an acceptable surrogate for FVC in the spirometric diagnosis of airway obstruction and restriction. Am J Respir Crit Care Med 2000; 162: 917-919.
-
(2000)
Am J Respir Crit Care Med
, vol.162
, pp. 917-919
-
-
Swanney, M.P.1
Jensen, R.L.2
Crichton, D.A.3
-
17
-
-
0034757380
-
Forced expiratory manoeuvres in children: Do they meet ATS and ERS criteria for spirometry?
-
Arets HG, Brackel HJ, van der Ent CK. Forced expiratory manoeuvres in children: Do they meet ATS and ERS criteria for spirometry? Eur Respir J 2001; 18: 655-660.
-
(2001)
Eur Respir J
, vol.18
, pp. 655-660
-
-
Arets, H.G.1
Brackel, H.J.2
Van Der Ent, C.K.3
-
18
-
-
2442430704
-
Quality control for spirometry in preschool children with and without lung disease
-
Aurora P, Stocks J, Oliver C, et al. Quality control for spirometry in preschool children with and without lung disease. Am J Respir Crit Care Med 2004; 169: 1152-1159.
-
(2004)
Am J Respir Crit Care Med
, vol.169
, pp. 1152-1159
-
-
Aurora, P.1
Stocks, J.2
Oliver, C.3
|