MEMS sensor technologies for human centred applications in healthcare, physical activities, safety and environmental sensing: A review on research activities in Italy

Author keywords

Environmental sensing; Healthcare; Human centred applications; MEMS sensor technologies; Physical activities; Rehabilitation; Research activity in Italy; Safety; Sport science

Indexed keywords

ACCIDENT PREVENTION; HEALTH CARE; PATIENT MONITORING; PATIENT REHABILITATION;

EID: 84928653796     PISSN: 14248220     EISSN: None     Source Type: Journal    
DOI: 10.3390/s150306441     Document Type: Review
Times cited : (125)

References (128)
  • 3
    • 33846693940 scopus 로고
    • Piezoresistance effect in germanium and silicon
    • Smith, C.S. Piezoresistance effect in germanium and silicon. Phys. Rev. 1954, 94, 42.
    • (1954) Phys. Rev , vol.94 , pp. 42
    • Smith, C.S.1
  • 4
    • 36149019864 scopus 로고
    • Pressure dependence of the resistivity of silicon
    • Paul, W.; Pearson, G. Pressure dependence of the resistivity of silicon. Phys. Rev. 1955, 98, 1755.
    • (1955) Phys. Rev , vol.98 , pp. 1755
    • Paul, W.1    Pearson, G.2
  • 5
    • 34249846476 scopus 로고
    • Semiconducting stress transducers utilizing the transverse and shear piezoresistance effects
    • Pfann, W.; Thurston, R. Semiconducting stress transducers utilizing the transverse and shear piezoresistance effects. J. Appl. Phys. 1961, 32, 2008–2019.
    • (1961) J. Appl. Phys , vol.32 , pp. 2008-2019
    • Pfann, W.1    Thurston, R.2
  • 6
    • 0000392980 scopus 로고
    • Silicon diffused-element piezoresistive diaphragms
    • Tufte, O.; Chapman, P.; Long, D. Silicon diffused-element piezoresistive diaphragms. J. Appl. Phys. 1962, 33, 3322–3327.
    • (1962) J. Appl. Phys , vol.33 , pp. 3322-3327
    • Tufte, O.1    Chapman, P.2    Long, D.3
  • 7
    • 33846691770 scopus 로고    scopus 로고
    • MEMS sensors: Past, present and future
    • Bogue, R. MEMS sensors: Past, present and future. Sens. Rev. 2007, 27, 7–13.
    • (2007) Sens. Rev , vol.27 , pp. 7-13
    • Bogue, R.1
  • 8
    • 84883338299 scopus 로고    scopus 로고
    • Recent developments in MEMS sensors: A review of applications, markets and technologies
    • Bogue, R. Recent developments in MEMS sensors: A review of applications, markets and technologies. Sens. Rev. 2013, 33, 300–304.
    • (2013) Sens. Rev , vol.33 , pp. 300-304
    • Bogue, R.1
  • 11
    • 84928651609 scopus 로고    scopus 로고
    • accessed on 13 March
    • MNX Company. What Is MEMS Technology? Available online:https://http://www.mems-exchange.org/MEMS/what-is.html (accessed on 13 March 2015).
    • (2015) What is MEMS Technology?
  • 12
    • 84897889254 scopus 로고    scopus 로고
    • Towards the trillion sensors market
    • Bogue, R. Towards the trillion sensors market. Sens. Rev. 2014, 34, 137–142.
    • (2014) Sens. Rev , vol.34 , pp. 137-142
    • Bogue, R.1
  • 16
    • 84921991337 scopus 로고    scopus 로고
    • Humove: A low-invasive wearable monitoring platform in sexual medicine
    • Ciuti, G.; Nardi, M.; Valdastri, P.; Menciassi, A.; Fasolo, C.B.; Dario, P. Humove: A low-invasive wearable monitoring platform in sexual medicine. Urology 2014, 84, 976–981.
    • (2014) Urology , vol.84 , pp. 976-981
    • Ciuti, G.1    Nardi, M.2    Valdastri, P.3    Menciassi, A.4    Fasolo, C.B.5    Dario, P.6
  • 17
    • 84863709848 scopus 로고    scopus 로고
    • Experimental Characterization of a Novel Fiber-Optic Accelerometer for the Quantitative Assessment of Rest Tremor in Parkinsonian Patients
    • Innsbruck, Austria, 15–17 February
    • Battista, L.; Scorza, A.; Sciuto, S.A. Experimental Characterization of a Novel Fiber-Optic Accelerometer for the Quantitative Assessment of Rest Tremor in Parkinsonian Patients. In Proceedings of the 9th IASTED International Conference of Biomedical Engineering, Innsbruck, Austria, 15–17 February 2012; pp. 437–442.
    • (2012) Proceedings of the 9Th IASTED International Conference of Biomedical Engineering , pp. 437-442
    • Battista, L.1    Scorza, A.2    Sciuto, S.A.3
  • 18
    • 84906087592 scopus 로고    scopus 로고
    • Technical and clinical view on ambulatory assessment in Parkinsonʼs disease
    • Hobert, M.; Maetzler, W.; Aminian, K.; Chiari, L. Technical and clinical view on ambulatory assessment in Parkinsonʼs disease. Acta Neurol. Scand. 2014, 130, 139–147.
    • (2014) Acta Neurol. Scand , vol.130 , pp. 139-147
    • Hobert, M.1    Maetzler, W.2    Aminian, K.3    Chiari, L.4
  • 20
    • 79956371410 scopus 로고    scopus 로고
    • Hilbert-huang-based tremor removal to assess postural properties from accelerometers
    • Mellone, S.; Palmerini, L.; Cappello, A.; Chiari, L. Hilbert-huang-based tremor removal to assess postural properties from accelerometers. IEEE Trans. Biomed. Eng. 2011, 58, 1752–1761.
    • (2011) IEEE Trans. Biomed. Eng , vol.58 , pp. 1752-1761
    • Mellone, S.1    Palmerini, L.2    Cappello, A.3    Chiari, L.4
  • 21
    • 84864335171 scopus 로고    scopus 로고
    • Postural sway as a marker of progression in Parkinsonʼs disease: A pilot longitudinal study
    • Mancini, M.; Carlson-Kuhta, P.; Zampieri, C.; Nutt, J.G.; Chiari, L.; Horak, F.B. Postural sway as a marker of progression in Parkinsonʼs disease: A pilot longitudinal study. Gait Posture 2012, 36, 471–476.
    • (2012) Gait Posture , vol.36 , pp. 471-476
    • Mancini, M.1    Carlson-Kuhta, P.2    Zampieri, C.3    Nutt, J.G.4    Chiari, L.5    Horak, F.B.6
  • 32
    • 77949422045 scopus 로고    scopus 로고
    • Robotic magnetic steering and locomotion of capsule endoscope for diagnostic and surgical endoluminal procedures
    • Ciuti, G.; Valdastri, P.; Menciassi, A.; Dario, P. Robotic magnetic steering and locomotion of capsule endoscope for diagnostic and surgical endoluminal procedures. Robotica 2010, 28, 199–207.
    • (2010) Robotica , vol.28 , pp. 199-207
    • Ciuti, G.1    Valdastri, P.2    Menciassi, A.3    Dario, P.4
  • 36
    • 84877864888 scopus 로고    scopus 로고
    • Design and development of a sensorized wireless toy for measuring infantsʼ manual actions
    • Serio, S.M.; Cecchi, F.; Assaf, T.; Laschi, C.; Dario, P. Design and development of a sensorized wireless toy for measuring infantsʼ manual actions. IEEE Trans. Neural Syst. Rehabil. Eng. 2013, 21, 444–453.
    • (2013) IEEE Trans. Neural Syst. Rehabil. Eng , vol.21 , pp. 444-453
    • Serio, S.M.1    Cecchi, F.2    Assaf, T.3    Laschi, C.4    Dario, P.5
  • 37
    • 84928674274 scopus 로고    scopus 로고
    • accessed on 13 March
    • EU Caretoy Project. Available online: http://www.caretoy.eu (accessed on 13 March 2015).
    • (2015)
  • 39
    • 84928675492 scopus 로고    scopus 로고
    • accessed on 13 March
    • EU Sensorart Project. Available online: http://www.sensorart.eu (accessed on 13 March 2015).
    • (2015)
  • 40
    • 84928681029 scopus 로고    scopus 로고
    • accessed on 13 March
    • ST Microelectronics. Available online: http://www.st.com (accessed on 13 March 2015).
    • (2015)
  • 44
    • 84904365289 scopus 로고    scopus 로고
    • On the operation of Lorentz-force mems magnetometers with a frequency offset between driving current and mechanical resonance
    • Langfelder, G.; Tocchio, A. On the operation of Lorentz-force mems magnetometers with a frequency offset between driving current and mechanical resonance. IEEE Trans. Magn. 2014, 50, doi:10.1109/TMAG.2013.2281404.
    • (2014) IEEE Trans. Magn , pp. 50
    • Langfelder, G.1    Tocchio, A.2
  • 48
    • 80755163536 scopus 로고    scopus 로고
    • New transparent bio-MEMS for uni-axial single cell stretching. Microsyst
    • Fior, R.; Maggiolino, S.; Lazzarino, M.; Sbaizero, O. A new transparent bio-MEMS for uni-axial single cell stretching. Microsyst. Technol. 2011, 17, 1581–1587.
    • (2011) Technol , vol.17 , pp. 1581-1587
    • Fior, R.1    Maggiolino, S.2    Lazzarino, M.3    Sbaizero, O.A.4
  • 49
    • 84872217235 scopus 로고    scopus 로고
    • Global Agenda Council on Ageing Society. Global Population Ageing: Peril or Promise? Available online: http://www3.weforum.org/docs/WEF_GAC_GlobalPopulationAgeing_Report_2012.pdf (accessed on 13 March 2015).
    • (2015) Global Population Ageing: Peril Or Promise?
  • 50
    • 85002585556 scopus 로고    scopus 로고
    • An Aging Nation: The Older Population in the United States—Population Estimates and Projections. Available online: http://www.census.gov/prod/2014pubs/p25–1140.pdf (accessed on 13 March 2015).
    • (2015)
  • 53
    • 81555221571 scopus 로고    scopus 로고
    • Accelerometry-based classification of human activities using Markov modeling
    • Mannini, A.; Sabatini, A.M. Accelerometry-based classification of human activities using Markov modeling. Comput. Intell. Neurosci. 2011, doi:10.1155/2011/647858.
    • (2011) Comput. Intell. Neurosci
    • Mannini, A.1    Sabatini, A.M.2
  • 57
    • 84899550567 scopus 로고    scopus 로고
    • Subject-Dependent Physical Activity Recognition Model Framework with a Semi-Supervised Clustering Approach
    • Manchester, UK, 20–22 November 2013
    • Ali, H.; Messina, E.; Bisiani, R. Subject-Dependent Physical Activity Recognition Model Framework with a Semi-Supervised Clustering Approach. In Proceedings of the 2013 European Modelling Symposium (EMS), Manchester, UK, 20–22 November 2013; pp. 42–47.
    • In Proceedings of the 2013 European Modelling Symposium (EMS) , pp. 42-47
    • Ali, H.1    Messina, E.2    Bisiani, R.3
  • 60
    • 84880855672 scopus 로고    scopus 로고
    • Supervised expert system for wearable MEMS accelerometer-based fall detector
    • Rescio, G.; Leone, A.; Siciliano, P. Supervised expert system for wearable MEMS accelerometer-based fall detector. J. Sens. 2013, doi:10.1155/2013/254629.
    • (2013) J. Sens
    • Rescio, G.1    Leone, A.2    Siciliano, P.3
  • 61
    • 84958521612 scopus 로고    scopus 로고
    • Supervised Machine Learning Scheme for Wearable Accelerometer-Based Fall Detector
    • Springer: Berlin, Germany
    • Rescio, G.; Leone, A.; Siciliano, P. Supervised Machine Learning Scheme for Wearable Accelerometer-Based Fall Detector. In Sensors and Microsystems; Springer: Berlin, Germany, 2014; pp. 295–299.
    • (2014) In Sensors and Microsystems , pp. 295-299
    • Rescio, G.1    Leone, A.2    Siciliano, P.3
  • 67
    • 84897103341 scopus 로고    scopus 로고
    • An instrumented insole for long term monitoring movement, comfort, and ergonomics
    • Cristiani, A.M.; Bertolotti, G.M.; Marenzi, E.; Ramat, S. An instrumented insole for long term monitoring movement, comfort, and ergonomics. IEEE Sens. J. 2014, 14, 1564–1572.
    • (2014) IEEE Sens. J , vol.14 , pp. 1564-1572
    • Cristiani, A.M.1    Bertolotti, G.M.2    Marenzi, E.3    Ramat, S.4
  • 69
    • 84928652312 scopus 로고    scopus 로고
    • accessed on 13 March
    • European FP7 Interaction Project. Available online: http://cms.interaction4stroke.eu/drupal/ (accessed on 13 March 2015).
    • (2015)
  • 72
    • 84879400721 scopus 로고    scopus 로고
    • Design of a wearable sensing system for human motion monitoring in physical rehabilitation
    • González-Villanueva, L.; Cagnoni, S.; Ascari, L. Design of a wearable sensing system for human motion monitoring in physical rehabilitation. Sensors 2013, 13, 7735–7755.
    • (2013) Sensors , vol.13 , pp. 7735-7755
    • González-Villanueva, L.1    Cagnoni, S.2    Ascari, L.3
  • 75
    • 84901390679 scopus 로고    scopus 로고
    • Design and validation of a motion-tracking system for ROM measurements in home rehabilitation
    • Daponte, P.; De Vito, L.; Riccio, M.; Sementa, C. Design and validation of a motion-tracking system for ROM measurements in home rehabilitation. Measurement 2014, 55, 82–96.
    • (2014) Measurement , vol.55 , pp. 82-96
    • Daponte, P.1    De Vito, L.2    Riccio, M.3    Sementa, C.4
  • 76
    • 84884166128 scopus 로고    scopus 로고
    • Directions towards effective utilization of tactile skin: A review
    • Dahiya, R.S.; Mittendorfer, P.; Valle, M.; Cheng, G.; Lumelsky, V. Directions towards effective utilization of tactile skin: A review. IEEE Sens. J. 2013, 13, 4121–4138.
    • (2013) IEEE Sens. J , vol.13 , pp. 4121-4138
    • Dahiya, R.S.1    Mittendorfer, P.2    Valle, M.3    Cheng, G.4    Lumelsky, V.5
  • 77
    • 84877352339 scopus 로고    scopus 로고
    • Synthetic and bio-artificial tactile sensing: A review
    • Lucarotti, C.; Oddo, C.M.; Vitiello, N.; Carrozza, M.C. Synthetic and bio-artificial tactile sensing: A review. Sensors 2013, 13, 1435–1466.
    • (2013) Sensors , vol.13 , pp. 1435-1466
    • Lucarotti, C.1    Oddo, C.M.2    Vitiello, N.3    Carrozza, M.C.4
  • 78
    • 78650360525 scopus 로고    scopus 로고
    • Control of hand prostheses using peripheral information
    • Micera, S.; Carpaneto, J.; Raspopovic, S. Control of hand prostheses using peripheral information. Biomed. Eng. IEEE Rev. 2010, 3, 48–68.
    • (2010) Biomed. Eng. IEEE Rev , vol.3 , pp. 48-68
    • Micera, S.1    Carpaneto, J.2    Raspopovic, S.3
  • 79
    • 84919489152 scopus 로고    scopus 로고
    • Towards the creation of tactile maps for robots and their use in robot contact motion control
    • Denei, S.; Mastrogiovanni, F.; Cannata, G. Towards the creation of tactile maps for robots and their use in robot contact motion control. Robot. Auton. Syst. 2015, 63, 293–308.
    • (2015) Robot. Auton. Syst , vol.63 , pp. 293-308
    • Denei, S.1    Mastrogiovanni, F.2    Cannata, G.3
  • 80
    • 79959858397 scopus 로고    scopus 로고
    • Roughness encoding in human and biomimetic artificial touch: Spatiotemporal frequency modulation and structural anisotropy of fingerprints
    • Oddo, C.M.; Beccai, L.; Wessberg, J.; Wasling, H.B.; Mattioli, F.; Carrozza, M.C. Roughness encoding in human and biomimetic artificial touch: Spatiotemporal frequency modulation and structural anisotropy of fingerprints. Sensors 2011, 11, 5596–5615.
    • (2011) Sensors , vol.11 , pp. 5596-5615
    • Oddo, C.M.1    Beccai, L.2    Wessberg, J.3    Wasling, H.B.4    Mattioli, F.5    Carrozza, M.C.6
  • 83
    • 79958765632 scopus 로고    scopus 로고
    • Roughness encoding for discrimination of surfaces in artificial active-touch
    • Oddo, C.M.; Controzzi, M.; Beccai, L.; Cipriani, C.; Carrozza, M.C. Roughness encoding for discrimination of surfaces in artificial active-touch. IEEE Trans. Robot. 2011, 27, 522–533.
    • (2011) IEEE Trans. Robot , vol.27 , pp. 522-533
    • Oddo, C.M.1    Controzzi, M.2    Beccai, L.3    Cipriani, C.4    Carrozza, M.C.5
  • 84
    • 84906861470 scopus 로고    scopus 로고
    • Tactile sensing chips with POSFET array and integrated interface electronics. Sens
    • Dahiya, R.S.; Adami, A.; Pinna, L.; Collini, C.; Valle, M.; Lorenzelli, L. Tactile sensing chips with POSFET array and integrated interface electronics. Sens. J. IEEE 2014, 14, 3448–3457.
    • (2014) J. IEEE , vol.14 , pp. 3448-3457
    • Dahiya, R.S.1    Adami, A.2    Pinna, L.3    Collini, C.4    Valle, M.5    Lorenzelli, L.6
  • 85
    • 84892170091 scopus 로고    scopus 로고
    • A wireless flexible sensorized insole for gait analysis
    • Crea, S.; Donati, M.; De Rossi, S.M.M.; Oddo, C.M.; Vitiello, N. A wireless flexible sensorized insole for gait analysis. Sensors 2014, 14, 1073–1093.
    • (2014) Sensors , vol.14 , pp. 1073-1093
    • Crea, S.1    Donati, M.2    De Rossi, S.3    Oddo, C.M.4    Vitiello, N.5
  • 86
    • 84863170400 scopus 로고    scopus 로고
    • MEMS conquering sports
    • Johnson, R. MEMS conquering sports. EE Times 2012, 1615, 28–30.
    • (2012) EE Times , vol.1615 , pp. 28-30
    • Johnson, R.1
  • 87
    • 84862899268 scopus 로고    scopus 로고
    • An enhanced estimate of initial contact and final contact instants of time using lower trunk inertial sensor data
    • McCamley, J.; Donati, M.; Grimpampi, E.; Mazzà, C. An enhanced estimate of initial contact and final contact instants of time using lower trunk inertial sensor data. Gait Posture 2012, 36, 316–318.
    • (2012) Gait Posture , vol.36 , pp. 316-318
    • McCamley, J.1    Donati, M.2    Grimpampi, E.3    Mazzà, C.4
  • 88
    • 78650293873 scopus 로고    scopus 로고
    • Countermovement jump performance assessment using a wearable 3d inertial measurement unit
    • Picerno, P.; Camomilla, V.; Capranica, L. Countermovement jump performance assessment using a wearable 3d inertial measurement unit. J. Sports Sci. 2011, 29, 139–146.
    • (2011) J. Sports Sci , vol.29 , pp. 139-146
    • Picerno, P.1    Camomilla, V.2    Capranica, L.3
  • 90
    • 84858615336 scopus 로고    scopus 로고
    • Estimation of temporal parameters during sprint running using a trunk-mounted inertial measurement unit
    • Bergamini, E.; Picerno, P.; Pillet, H.; Natta, F.; Thoreux, P.; Camomilla, V. Estimation of temporal parameters during sprint running using a trunk-mounted inertial measurement unit. J. Biomech. 2012, 45, 1123–1126.
    • (2012) J. Biomech , vol.45 , pp. 1123-1126
    • Bergamini, E.1    Picerno, P.2    Pillet, H.3    Natta, F.4    Thoreux, P.5    Camomilla, V.6
  • 91
    • 84860194407 scopus 로고    scopus 로고
    • Least-squares identification algorithm for estimating squat exercise mechanics using a single inertial measurement unit
    • Bonnet, V.; Mazzà, C.; Fraisse, P.; Cappozzo, A. A least-squares identification algorithm for estimating squat exercise mechanics using a single inertial measurement unit. J. Biomech. 2012, 45, 1472–1477.
    • (2012) J. Biomech , vol.45 , pp. 1472-1477
    • Bonnet, V.1    Mazzà, C.2    Fraisse, P.3    Cappozzo, A.A.4
  • 93
  • 94
    • 84898405965 scopus 로고    scopus 로고
    • Validity of the sensewear armband to assess energy expenditure during intermittent exercise and recovery in Rugby Union players
    • Zanetti, S.; Pumpa, K.L.; Wheeler, K.W.; Pyne, D.B. Validity of the sensewear armband to assess energy expenditure during intermittent exercise and recovery in Rugby Union players. J. Strength Cond. Res. 2014, 28, 1090–1095.
    • (2014) J. Strength Cond. Res , vol.28 , pp. 1090-1095
    • Zanetti, S.1    Pumpa, K.L.2    Wheeler, K.W.3    Pyne, D.B.4
  • 96
    • 84883245251 scopus 로고    scopus 로고
    • Integration of Bluetooth handsfree sensors into a wireless body area network based on smartphone
    • Springer: Berlin, Germany
    • Depari, A.; de Dominicis, C.; Flammini, A.; Rinaldi, S.; Vezzoli, A. Integration of Bluetooth handsfree sensors into a wireless body area network based on smartphone. In Sensors; Springer: Berlin, Germany, 2014; pp. 547–551.
    • (2014) In Sensors , pp. 547-551
    • Depari, A.1    De Dominicis, C.2    Flammini, A.3    Rinaldi, S.4    Vezzoli, A.5
  • 100
    • 84885414339 scopus 로고    scopus 로고
    • Analysis of balance, rapidity, force and reaction times of soccer players at different levels of competition
    • Ricotti, L.; Rigosa, J.; Niosi, A.; Menciassi, A. Analysis of balance, rapidity, force and reaction times of soccer players at different levels of competition. PLoS One 2013, 8, e77264.
    • (2013) Plos One , vol.8
    • Ricotti, L.1    Rigosa, J.2    Niosi, A.3    Menciassi, A.4
  • 101
    • 84859817910 scopus 로고    scopus 로고
    • Static and dynamic balance in young athletes
    • Ricotti, L. Static and dynamic balance in young athletes. J. Hum. Sport Exerc. 2011, 6, 616–618.
    • (2011) J. Hum. Sport Exerc , vol.6 , pp. 616-618
    • Ricotti, L.1
  • 102
    • 79952002326 scopus 로고    scopus 로고
    • Break dance significantly increases static balance in 9 years-old soccer players
    • Ricotti, L.; Ravaschio, A. Break dance significantly increases static balance in 9 years-old soccer players. Gait Posture 2011, 33, 462–465.
    • (2011) Gait Posture , vol.33 , pp. 462-465
    • Ricotti, L.1    Ravaschio, A.2
  • 103
    • 84887888886 scopus 로고    scopus 로고
    • Stresses in the plantar region for long-and short-range throws in women basketball players
    • Pau, M.; Ciuti, C. Stresses in the plantar region for long-and short-range throws in women basketball players. Eur. J. Sport Sci. 2013, 13, 575–581.
    • (2013) Eur. J. Sport Sci , vol.13 , pp. 575-581
    • Pau, M.1    Ciuti, C.2
  • 105
    • 85013003365 scopus 로고    scopus 로고
    • Technical skill differences in stroke propulsion between high level athletes in triathlon and top level swimmers
    • Bottoni, A.; Lanotte, N.; Boatto, P.; Bifaretti, S.; Bonifazi, M. Technical skill differences in stroke propulsion between high level athletes in triathlon and top level swimmers. J. Hum. Sport Exerc. 2011, 6, 351–362.
    • (2011) J. Hum. Sport Exerc , vol.6 , pp. 351-362
    • Bottoni, A.1    Lanotte, N.2    Boatto, P.3    Bifaretti, S.4    Bonifazi, M.5
  • 106
    • 84929043119 scopus 로고    scopus 로고
    • A modified prebind engagement process reduces biomechanical loading on front row players during scrummaging: A cross-sectional study of 11 elite teams
    • Cazzola, D.; Preatoni, E.; Stokes, K.A.; England, M.E.; Trewartha, G. A modified prebind engagement process reduces biomechanical loading on front row players during scrummaging: A cross-sectional study of 11 elite teams. Br. J. Sports Med. 2014, doi:10.1136/bjsports-2013-092904.
    • (2014) Br. J. Sports Med
    • Cazzola, D.1    Preatoni, E.2    Stokes, K.A.3    England, M.E.4    Trewartha, G.5
  • 107
    • 84892761157 scopus 로고    scopus 로고
    • Affinity-based biosensors in sport medicine and doping control analysis
    • Mazzei, F.; Antiochia, R.; Botrè, F.; Favero, G.; Tortolini, C. Affinity-based biosensors in sport medicine and doping control analysis. Bioanalysis 2014, 6, 225–245.
    • (2014) Bioanalysis , vol.6 , pp. 225-245
    • Mazzei, F.1    Antiochia, R.2    Botrè, F.3    Favero, G.4    Tortolini, C.5
  • 108
    • 84958550331 scopus 로고    scopus 로고
    • A wearable sweat pH and body temperature sensor platform for health, fitness, and wellness applications
    • Springer: Berlin, Germany
    • Caldara, M.; Colleoni, C.; Guido, E.; Re, V.; Rosace, G.; Vitali, A. A wearable sweat pH and body temperature sensor platform for health, fitness, and wellness applications. In Sensors and Microsystems; Springer: Berlin, Germany, 2014; pp. 431–434.
    • (2014) In Sensors and Microsystems , pp. 431-434
    • Caldara, M.1    Colleoni, C.2    Guido, E.3    Re, V.4    Rosace, G.5    Vitali, A.6
  • 109
    • 84864283881 scopus 로고    scopus 로고
    • Development of a textile-optoelectronic pH meter based on hybrid xerogel doped with methyl red
    • Caldara, M.; Colleoni, C.; Guido, E.; Re, V.; Rosace, G. Development of a textile-optoelectronic pH meter based on hybrid xerogel doped with methyl red. Sens. Actuators B Chem. 2012, 171, 1013–1021.
    • (2012) Sens. Actuators B Chem , vol.171 , pp. 1013-1021
    • Caldara, M.1    Colleoni, C.2    Guido, E.3    Re, V.4    Rosace, G.5
  • 111
    • 84958521612 scopus 로고    scopus 로고
    • Supervised machine learning scheme for wearable accelerometer-based fall detector. In Lecture Notes in Electrical Engineering; Springer
    • Rescio, G.; Leone, A.; Siciliano, P. Supervised machine learning scheme for wearable accelerometer-based fall detector. In Lecture Notes in Electrical Engineering; Springer: Berlin, Germany, 2014, Volume 268, pp. 295–299.
    • (2014) Berlin, Germany , vol.268 , pp. 295-299
    • Rescio, G.1    Leone, A.2    Siciliano, P.3
  • 112
    • 84860209850 scopus 로고    scopus 로고
    • Benefits of combined gps/glonass with low-cost MEMS IMUS for vehicular urban navigation
    • Angrisano, A.; Petovello, M.; Pugliano, G. Benefits of combined gps/glonass with low-cost MEMS IMUS for vehicular urban navigation. Sensors 2012, 12, 5134–5158.
    • (2012) Sensors , vol.12 , pp. 5134-5158
    • Angrisano, A.1    Petovello, M.2    Pugliano, G.3
  • 113
    • 80054866063 scopus 로고    scopus 로고
    • Field tests on gnss and inertial systems for transport fleet monitoring in urban environment
    • Fastellini, G.; Radicioni, F.; Stoppini, A. Field tests on gnss and inertial systems for transport fleet monitoring in urban environment. Ital. J. Remote Sens. 2011, 43, 41–54.
    • (2011) Ital. J. Remote Sens , vol.43 , pp. 41-54
    • Fastellini, G.1    Radicioni, F.2    Stoppini, A.3
  • 117
    • 84886285795 scopus 로고    scopus 로고
    • Multi-site damage localization in a suspension bridge via aftershock monitoring
    • Domaneschi, M.; Limongelli, M.; Martinelli, L. Multi-site damage localization in a suspension bridge via aftershock monitoring. Ing. Sism. 2013, 30, 56–72.
    • (2013) Ing. Sism , vol.30 , pp. 56-72
    • Domaneschi, M.1    Limongelli, M.2    Martinelli, L.3
  • 118
    • 79952618439 scopus 로고    scopus 로고
    • Cascaded “triple-bent-beam” MEMS sensor for contactless temperature measurements in nonaccessible environments
    • Andò, B.; Baglio, S.; Savalli, N.; Trigona, C. Cascaded “triple-bent-beam” MEMS sensor for contactless temperature measurements in nonaccessible environments. IEEE Trans. Instrum. Meas. 2011, 60, 1348–1357.
    • (2011) IEEE Trans. Instrum. Meas , vol.60 , pp. 1348-1357
    • Andò, B.1    Baglio, S.2    Savalli, N.3    Trigona, C.4
  • 124
    • 84928660811 scopus 로고    scopus 로고
    • accessed on 13 March
    • Tutte le novità sugli smarphone biometrici: Il futuro è nei sensori—nova24 tech—il sole 24 ore. Available online: http://www.ilsole24ore.com/art/tecnologie/2014–02–21/tutte-novita-smarphone-biometrici-futuro-e-sensori-153549.shtml?uuid=ABgX4Cy (accessed on 13 March 2015).
    • (2015)
  • 125
    • 84928663698 scopus 로고    scopus 로고
    • accessed on 13 March
    • MEMS Market to Top $22 Billion by 2018—Source: Yole. Available online: http://www.eetimes.com/document.asp?doc_id=1320035 (accessed on 13 March 2015).
    • (2015)
  • 127
    • 84928673452 scopus 로고    scopus 로고
    • accessed on 13 March
    • Arduino Technologies. Available online: http://www.arduino.cc (accessed on 13 March 2015).
    • (2015)
  • 128
    • 84928664581 scopus 로고    scopus 로고
    • accessed on 13 March
    • Maker formato arduino—nova24 tech—il sole 24 ore. Available online: http://www.ilsole24ore.com/art/tecnologie/2014–10–06/maker-formato-arduino--105857.shtml?uuid=ABaiRQ0B (accessed on 13 March 2015).
    • (2015)


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.