메뉴 건너뛰기




Volumn 26, Issue 5, 2016, Pages 518-527

Constant infusion transpulmonary thermodilution for the assessment of cardiac output in exercising humans

Author keywords

Arm exercise; Blood flow; Cardiac output; Exercise; Humans; Performance; Thermistor; Thermodilution

Indexed keywords

COLORING AGENT; INDOCYANINE GREEN; SODIUM CHLORIDE;

EID: 84928573097     PISSN: 09057188     EISSN: 16000838     Source Type: Journal    
DOI: 10.1111/sms.12473     Document Type: Article
Times cited : (8)

References (34)
  • 1
    • 0022270890 scopus 로고
    • Maximal perfusion of skeletal muscle in man
    • Andersen P, Saltin B. Maximal perfusion of skeletal muscle in man. J Physiol 1985: 366: 233-249.
    • (1985) J Physiol , vol.366 , pp. 233-249
    • Andersen, P.1    Saltin, B.2
  • 3
    • 29844448951 scopus 로고    scopus 로고
    • Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model
    • Bajorat J, Hofmockel R, Vagts DA, Janda M, Pohl B, Beck C, Noeldge-Schomburg G. Comparison of invasive and less-invasive techniques of cardiac output measurement under different haemodynamic conditions in a pig model. Eur J Anaesthesiol 2006: 23: 23-30.
    • (2006) Eur J Anaesthesiol , vol.23 , pp. 23-30
    • Bajorat, J.1    Hofmockel, R.2    Vagts, D.A.3    Janda, M.4    Pohl, B.5    Beck, C.6    Noeldge-Schomburg, G.7
  • 4
    • 84908219488 scopus 로고
    • Statistical methods for assessing agreement between two methods of clinical measurement
    • Bland JM, Altman DG. Statistical methods for assessing agreement between two methods of clinical measurement. Lancet 1986: 1: 307-310.
    • (1986) Lancet , vol.1 , pp. 307-310
    • Bland, J.M.1    Altman, D.G.2
  • 6
    • 0035834152 scopus 로고    scopus 로고
    • Parasympathetic neural activity accounts for the lowering of exercise heart rate at high altitude
    • Boushel R, Calbet JA, Radegran G, Sondergaard H, Wagner PD, Saltin B. Parasympathetic neural activity accounts for the lowering of exercise heart rate at high altitude. Circulation 2001: 104: 1785-1791.
    • (2001) Circulation , vol.104 , pp. 1785-1791
    • Boushel, R.1    Calbet, J.A.2    Radegran, G.3    Sondergaard, H.4    Wagner, P.D.5    Saltin, B.6
  • 7
    • 84920463516 scopus 로고    scopus 로고
    • Assessment of cardiac output with transpulmonary thermodilution during exercise in humans
    • Calbet JA, Boushel R. Assessment of cardiac output with transpulmonary thermodilution during exercise in humans. J Appl Physiol 2015 (118): 1-10.
    • (2015) J Appl Physiol , Issue.118 , pp. 1-10
    • Calbet, J.A.1    Boushel, R.2
  • 10
    • 0002586831 scopus 로고
    • Estimations of cardiac output and central blood volume by dye dilution
    • Dow P. Estimations of cardiac output and central blood volume by dye dilution. Physiol Rev 1956: 36: 77-102.
    • (1956) Physiol Rev , vol.36 , pp. 77-102
    • Dow, P.1
  • 11
    • 0014893340 scopus 로고
    • A comparison between the thermal dilution method and the direct Fick and the dye dilution methods for cardiac output measurements in man
    • Enghoff E, Michaelsson M, Pavek K, Sjogren S. A comparison between the thermal dilution method and the direct Fick and the dye dilution methods for cardiac output measurements in man. Acta Soc Med Ups 1970: 75: 157-170.
    • (1970) Acta Soc Med Ups , vol.75 , pp. 157-170
    • Enghoff, E.1    Michaelsson, M.2    Pavek, K.3    Sjogren, S.4
  • 12
    • 85047672736 scopus 로고
    • Analysis of errors in measurement of cardiac output by simultaneous dye and thermal dilution in cardiothoracic surgical patients
    • Fischer AP, Benis AM, Jurado RA, Seely E, Teirstein P, Litwak RS. Analysis of errors in measurement of cardiac output by simultaneous dye and thermal dilution in cardiothoracic surgical patients. Cardiovasc Res 1978: 12: 190-199.
    • (1978) Cardiovasc Res , vol.12 , pp. 190-199
    • Fischer, A.P.1    Benis, A.M.2    Jurado, R.A.3    Seely, E.4    Teirstein, P.5    Litwak, R.S.6
  • 13
    • 84964445114 scopus 로고    scopus 로고
    • Statistical Inference for Coefficients of Variation Shared by Several Populations. Swedish University of Agricultural Sciences, 1-17.
    • Forkman J. Statistical Inference for Coefficients of Variation Shared by Several Populations. Swedish University of Agricultural Sciences, 2007:1-17.
    • (2007)
    • Forkman, J.1
  • 14
    • 0031979188 scopus 로고    scopus 로고
    • Reproducibility of double indicator dilution measurements of intrathoracic blood volume compartments, extravascular lung water, and liver function
    • Godje O, Peyerl M, Seebauer T, Dewald O, Reichart B. Reproducibility of double indicator dilution measurements of intrathoracic blood volume compartments, extravascular lung water, and liver function. Chest 1998: 113: 1070-1077.
    • (1998) Chest , vol.113 , pp. 1070-1077
    • Godje, O.1    Peyerl, M.2    Seebauer, T.3    Dewald, O.4    Reichart, B.5
  • 17
    • 0022401426 scopus 로고
    • Analysis of factors affecting the variability of Fick versus indicator dilution measurements of cardiac output
    • Hillis LD, Firth BG, Winniford MD. Analysis of factors affecting the variability of Fick versus indicator dilution measurements of cardiac output. Am J Cardiol 1985: 56: 764-768.
    • (1985) Am J Cardiol , vol.56 , pp. 764-768
    • Hillis, L.D.1    Firth, B.G.2    Winniford, M.D.3
  • 18
    • 84869869331 scopus 로고    scopus 로고
    • Effects of cardiac output levels on the measurement of transpulmonary thermodilution cardiac output in patients with acute respiratory distress syndrome
    • Huang CC, Chen NH, Li LF, Yang CT, Hsiao HF, Chen YH, Lin HL, Kao KC. Effects of cardiac output levels on the measurement of transpulmonary thermodilution cardiac output in patients with acute respiratory distress syndrome. J Trauma Acute Care Surg 2012: 73: 1236-1241.
    • (2012) J Trauma Acute Care Surg , vol.73 , pp. 1236-1241
    • Huang, C.C.1    Chen, N.H.2    Li, L.F.3    Yang, C.T.4    Hsiao, H.F.5    Chen, Y.H.6    Lin, H.L.7    Kao, K.C.8
  • 20
    • 0033101729 scopus 로고    scopus 로고
    • Improved accuracy and precision of thermodilution cardiac output measurement using a dual thermistor catheter system
    • Lehmann KG, Platt MS. Improved accuracy and precision of thermodilution cardiac output measurement using a dual thermistor catheter system. J Am Coll Cardiol 1999: 33: 883-891.
    • (1999) J Am Coll Cardiol , vol.33 , pp. 883-891
    • Lehmann, K.G.1    Platt, M.S.2
  • 21
    • 0018639392 scopus 로고
    • Thermodilution cardiac output: a critical analysis and review of the literature
    • Levett JM, Replogle RL. Thermodilution cardiac output: a critical analysis and review of the literature. J Surg Res 1979: 27: 392-404.
    • (1979) J Surg Res , vol.27 , pp. 392-404
    • Levett, J.M.1    Replogle, R.L.2
  • 26
    • 78650076886 scopus 로고
    • Measurement of cardiac output by thermodilution with constant rate injection of indicator
    • Pavek K, Boska D, Selecky FV. Measurement of cardiac output by thermodilution with constant rate injection of indicator. Circ Res 1964: 15: 311-319.
    • (1964) Circ Res , vol.15 , pp. 311-319
    • Pavek, K.1    Boska, D.2    Selecky, F.V.3
  • 27
    • 77949305811 scopus 로고    scopus 로고
    • Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives
    • Reuter DA, Huang C, Edrich T, Shernan SK, Eltzschig HK. Cardiac output monitoring using indicator-dilution techniques: basics, limits, and perspectives. Anesth Analg 2010: 110: 799-811.
    • (2010) Anesth Analg , vol.110 , pp. 799-811
    • Reuter, D.A.1    Huang, C.2    Edrich, T.3    Shernan, S.K.4    Eltzschig, H.K.5
  • 28
    • 84912043627 scopus 로고    scopus 로고
    • Metabolic and mechanical involvement of arms and legs in simulated double pole skiing
    • Rud B, Secher NH, Nilsson J, Smith G, Hallen J. Metabolic and mechanical involvement of arms and legs in simulated double pole skiing. Scand J Med Sci Sports 2014: 24: 913-919.
    • (2014) Scand J Med Sci Sports , vol.24 , pp. 913-919
    • Rud, B.1    Secher, N.H.2    Nilsson, J.3    Smith, G.4    Hallen, J.5
  • 30
    • 84872310996 scopus 로고    scopus 로고
    • Biomechanical determinants of oxygen extraction during cross-country skiing
    • Stoggl T, Bjorklund G, Holmberg HC. Biomechanical determinants of oxygen extraction during cross-country skiing. Scand J Med Sci Sports 2013: 23: e9-e20.
    • (2013) Scand J Med Sci Sports , vol.23 , pp. e9-e20
    • Stoggl, T.1    Bjorklund, G.2    Holmberg, H.C.3
  • 31
    • 84925602605 scopus 로고    scopus 로고
    • Cardiac output monitoring: a contemporary assessment and review
    • Thiele RH, Bartels K, Gan TJ. Cardiac output monitoring: a contemporary assessment and review. Crit Care Med 2015: 43: 177-185.
    • (2015) Crit Care Med , vol.43 , pp. 177-185
    • Thiele, R.H.1    Bartels, K.2    Gan, T.J.3
  • 33
    • 0032900236 scopus 로고    scopus 로고
    • Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part I: conventional techniques
    • Warburton DE, Haykowsky MJ, Quinney HA, Humen DP, Teo KK. Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part I: conventional techniques. Sports Med 1999a: 27: 23-41.
    • (1999) Sports Med , vol.27 , pp. 23-41
    • Warburton, D.E.1    Haykowsky, M.J.2    Quinney, H.A.3    Humen, D.P.4    Teo, K.K.5
  • 34
    • 0032947120 scopus 로고    scopus 로고
    • Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part II: novel techniques and new advances
    • Warburton DE, Haykowsky MJ, Quinney HA, Humen DP, Teo KK. Reliability and validity of measures of cardiac output during incremental to maximal aerobic exercise. Part II: novel techniques and new advances. Sports Med 1999b: 27: 241-260.
    • (1999) Sports Med , vol.27 , pp. 241-260
    • Warburton, D.E.1    Haykowsky, M.J.2    Quinney, H.A.3    Humen, D.P.4    Teo, K.K.5