메뉴 건너뛰기




Volumn 10, Issue 12, 2015, Pages 1396-1401

The ABSORB EXTEND study: Preliminary report of the twelvemonth clinical outcomes in the first 512 patients enrolled

Author keywords

Bioresorbable scaffold; Coronary artery disease; Everolimus; Percutaneous coronary intervention; Poly (L lactide)

Indexed keywords

EVEROLIMUS; ANTINEOPLASTIC AGENT; CREATINE KINASE MB;

EID: 84928396540     PISSN: 1774024X     EISSN: 19696213     Source Type: Journal    
DOI: 10.4244/EIJV10I12A243     Document Type: Article
Times cited : (136)

References (14)
  • 3
    • 40649083620 scopus 로고    scopus 로고
    • A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): A prospective open-label trial
    • Ormiston JA, Serruys PW, Regar E, Dudek D., Thuesen L, Webster MW, Onuma Y, Garcia-Garcia HM, McGreevy R., Veldhof S. A bioabsorbable everolimus-eluting coronary stent system for patients with single de-novo coronary artery lesions (ABSORB): a prospective open-label trial. Lancet. 2008; 371:899-907.
    • (2008) Lancet , vol.371 , pp. 899-907
    • Ormiston, J.A.1    Serruys, P.W.2    Regar, E.3    Dudek, D.4    Thuesen, L.5    Webster, M.W.6    Onuma, Y.7    Garcia-Garcia, H.M.8    McGreevy, R.9    Veldhof, S.10
  • 5
    • 79952044287 scopus 로고    scopus 로고
    • Design principles and performance of bioresorbable polymeric vascular scaffolds
    • Oberhauser JP, Hossainy S, Rapoza R. Design principles and performance of bioresorbable polymeric vascular scaffolds. Euro Intervention. 2009; 5:F15-22.
    • (2009) Euro Intervention , vol.5 , pp. F15-22
    • Oberhauser, J.P.1    Hossainy, S.2    Rapoza, R.3
  • 6
    • 77956166657 scopus 로고    scopus 로고
    • In vivo evaluation of stent strut distribution patterns in the bioabsorbable everolimus-eluting device: An OCT ad hoc analysis of the revision 1.0 and revision 1.1 stent design in the ABSORB clinical trial
    • Okamura T, Garg S, Gutierrez-Chico JL, Shin E.S., Onuma Y., Garcia-Garcia HM, Rapoza RJ, Sudhir K, Regar E., Serruys PW. In vivo evaluation of stent strut distribution patterns in the bioabsorbable everolimus-eluting device: an OCT ad hoc analysis of the revision 1.0 and revision 1.1 stent design in the ABSORB clinical trial. Euro Intervention. 2010; 5:932-8.
    • (2010) Euro Intervention , vol.5 , pp. 932-938
    • Okamura, T.1    Garg, S.2    Gutierrez-Chico, J.L.3    Shin, E.S.4    Onuma, Y.5    Garcia-Garcia, H.M.6    Rapoza, R.J.7    Sudhir, K.8    Regar, E.9    Serruys, P.W.10
  • 9
    • 84856285896 scopus 로고    scopus 로고
    • Four-year clinical follow-up of the ABSORB everolimus-eluting bioresorbable vascular scaffold in patients with de novo coronary artery disease: The ABSORB trial
    • Dudek D, Onuma Y, Ormiston J.A., Thuesen L., Miquel-Hebert K, Serruys PW. Four-year clinical follow-up of the ABSORB everolimus-eluting bioresorbable vascular scaffold in patients with de novo coronary artery disease: the ABSORB trial. Euro Intervention. 2012; 7:1060-1.
    • (2012) Euro Intervention , vol.7 , pp. 1060-1061
    • Dudek, D.1    Onuma, Y.2    Ormiston, J.A.3    Thuesen, L.4    Miquel-Hebert, K.5    Serruys, P.W.6
  • 12
    • 42049121043 scopus 로고    scopus 로고
    • One year clinical follow-up of the XIENCE V everolimus-eluting stent system in the treatment of patients with de novo native coronary artery lesions: The SPIRIT II study
    • Ruygrok PN, Desaga M, Van Den Branden F, Rasmussen K, Suryapranata H, Dorange C, Veldhof S, Serruys PW. One year clinical follow-up of the XIENCE V Everolimus-eluting stent system in the treatment of patients with de novo native coronary artery lesions: the SPIRIT II study. Euro Intervention. 2007; 3:315-20.
    • (2007) Euro Intervention , vol.3 , pp. 315-320
    • Ruygrok, P.N.1    Desaga, M.2    Van Den Branden, F.3    Rasmussen, K.4    Suryapranata, H.5    Dorange, C.6    Veldhof, S.7    Serruys, P.W.8


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.