-
1
-
-
0035172358
-
On the heating of linear conductive structures as guide wires and catheters in interventional MRI
-
Nitz WR, Oppelt A, Renz W, Manke C, Lenhart M, Link J,. On the heating of linear conductive structures as guide wires and catheters in interventional MRI. J Magn Reson Imaging 2001; 13: 105-114.
-
(2001)
J Magn Reson Imaging
, vol.13
, pp. 105-114
-
-
Nitz, W.R.1
Oppelt, A.2
Renz, W.3
Manke, C.4
Lenhart, M.5
Link, J.6
-
2
-
-
0036136666
-
RF safety of wires in interventional MRI: Using a safety index
-
Yeung CJ, Susil RC, Atalar E,. RF safety of wires in interventional MRI: using a safety index. Magn Reson Med 2002; 47: 187-193.
-
(2002)
Magn Reson Med
, vol.47
, pp. 187-193
-
-
Yeung, C.J.1
Susil, R.C.2
Atalar, E.3
-
3
-
-
27644509327
-
Permanent neurological deficit related to magnetic resonance imaging in a patient with implanted deep brain stimulation electrodes for Parkinson's disease: Case report
-
Henderson JM, Tkach J, Phillips M, Baker K, Shellock FG, Rezai AR,. Permanent neurological deficit related to magnetic resonance imaging in a patient with implanted deep brain stimulation electrodes for Parkinson's disease: case report. Neurosurgery 2005; 57: E1063.
-
(2005)
Neurosurgery
, vol.57
, pp. E1063
-
-
Henderson, J.M.1
Tkach, J.2
Phillips, M.3
Baker, K.4
Shellock, F.G.5
Rezai, A.R.6
-
4
-
-
0035017776
-
A Green's function approach to local rf heating in interventional MRI
-
Yeung CJ, Atalar E,. A Green's function approach to local rf heating in interventional MRI. Med Phys 2001; 28: 826-832.
-
(2001)
Med Phys
, vol.28
, pp. 826-832
-
-
Yeung, C.J.1
Atalar, E.2
-
5
-
-
75749127510
-
New.method to monitor RF safety in MRI-guided interventions based on RF induced image artefacts
-
van den Bosch MR, Moerland MA, Lagendijk JJW, Bartels LW, van den Berg CAT,. New.method to monitor RF safety in MRI-guided interventions based on RF induced image artefacts. Med Phys 2010; 37: 814-821.
-
(2010)
Med Phys
, vol.37
, pp. 814-821
-
-
Van Den Bosch, M.R.1
Moerland, M.A.2
Lagendijk, J.J.W.3
Bartels, L.W.4
Van Den Berg, C.A.T.5
-
6
-
-
27644557247
-
Simple design changes to wires to substantially reduce. MRI-induced heating at 1.5 T: Implications for implanted leads
-
Gray RW, Bibens WT, Shellock FG,. Simple design changes to wires to substantially reduce. MRI-induced heating at 1.5 T: implications for implanted leads. Magn Reson Imaging. 2005; 23: 887-891.
-
(2005)
Magn Reson Imaging
, vol.23
, pp. 887-891
-
-
Gray, R.W.1
Bibens, W.T.2
Shellock, F.G.3
-
7
-
-
77954748895
-
Designing passive MRI-safe implantable conducting leads with electrodes
-
Bottomley PA, Kumar A, Edelstein WA, Allen JM, Karmarkar PV., Designing passive MRI-safe implantable conducting leads with electrodes Med Phys 2010; 37: 3828-3843.
-
(2010)
Med Phys
, vol.37
, pp. 3828-3843
-
-
Bottomley, P.A.1
Kumar, A.2
Edelstein, W.A.3
Allen, J.M.4
Karmarkar, P.V.5
-
8
-
-
79954622959
-
Reduction of implant RF heating through modification of electric field
-
Eryaman Y, Akin B, Atalar E,. Reduction of implant RF heating through modification of electric field. Magn Reson Med 2011; 65: 1305-1313.
-
(2011)
Magn Reson Med
, vol.65
, pp. 1305-1313
-
-
Eryaman, Y.1
Akin, B.2
Atalar, E.3
-
9
-
-
84874385333
-
Reduction of the radiofrequency heating of metallic devices using a dual-drive birdcage coil
-
Eryaman Y, Turk EA, Oto C, Algin O, Atalar E,. Reduction of the radiofrequency heating of metallic devices using a dual-drive birdcage coil. Magn Reson Med 2013; 69: 845-852.
-
(2013)
Magn Reson Med
, vol.69
, pp. 845-852
-
-
Eryaman, Y.1
Turk, E.A.2
Oto, C.3
Algin, O.4
Atalar, E.5
-
11
-
-
57149090290
-
Slice-selective RF pulses for in vivo B1 inhomogeneity mitigation at 7 Tesla using parallel RF excitation with a 16-element coil
-
Setsompop K, Alagappan V, Gagoski B, et al. Slice-selective RF pulses for in vivo B1 inhomogeneity mitigation at 7 Tesla using parallel RF excitation with a 16-element coil. Magn Reson Med 2008; 60: 1422-1432.
-
(2008)
Magn Reson Med
, vol.60
, pp. 1422-1432
-
-
Setsompop, K.1
Alagappan, V.2
Gagoski, B.3
-
12
-
-
84866393981
-
Two-dimensional sixteen channel transmit/receive coil array for cardiac MRI at 7.0 T: Design, evaluation, and application
-
Thalhammer C, Renz W, Winter L, et al. Two-dimensional sixteen channel transmit/receive coil array for cardiac MRI at 7.0 T: design, evaluation, and application. J Magn Reson Imaging 2012; 36: 847-857.
-
(2012)
J Magn Reson Imaging
, vol.36
, pp. 847-857
-
-
Thalhammer, C.1
Renz, W.2
Winter, L.3
-
13
-
-
84875701049
-
Design, evaluation and application of an eight channel transmit/receive coil array for cardiac MRI at 7.0 T
-
Grßl A, Winter L, Thalhammer C, Renz W, Kellman P, Martin C, von Knobelsdorff-Brenkenhoff F, Tkachenko V, Schulz-Menger J, Niendorf T,. Design, evaluation and application of an eight channel transmit/receive coil array for cardiac MRI at 7.0 T. Eur J Radiol 2011; 82: 752-759.
-
(2011)
Eur J Radiol
, vol.82
, pp. 752-759
-
-
Grßl, A.1
Winter, L.2
Thalhammer, C.3
Renz, W.4
Kellman, P.5
Martin, C.6
Von Knobelsdorff-Brenkenhoff, F.7
Tkachenko, V.8
Schulz-Menger, J.9
Niendorf, T.10
-
14
-
-
77952676573
-
A 32-channel lattice transmission line array for parallel transmit and receive MRI at 7 tesla
-
Adriany G, Auerbach EJ, Snyder CJ, Gözübüyük A, Moeller S, Ritter J, Van de Moortele PF, Vaughan T, Uʇurbil K,. A 32-channel lattice transmission line array for parallel transmit and receive MRI at 7 tesla. Magn Reson Med 2010; 63: 1478-1485.
-
(2010)
Magn Reson Med
, vol.63
, pp. 1478-1485
-
-
Adriany, G.1
Auerbach, E.J.2
Snyder, C.J.3
Gözübüyük, A.4
Moeller, S.5
Ritter, J.6
Van De Moortele, P.F.7
Vaughan, T.8
Uʇurbil, K.9
-
15
-
-
1842586446
-
Parallel excitation with an array of transmit coils
-
Zhu, Y,. Parallel excitation with an array of transmit coils. Magn Reson Med 2004; 51: 775-784.
-
(2004)
Magn Reson Med
, vol.51
, pp. 775-784
-
-
Zhu, Y.1
-
16
-
-
0037223717
-
Transmit SENSE
-
Katscher U, Börnert P, Leussler C, van den Brink JS, Transmit SENSE. Magn Reson Med 2003; 49: 14.
-
(2003)
Magn Reson Med
, vol.49
, pp. 14
-
-
Katscher, U.1
Börnert, P.2
Leussler, C.3
Van Den Brink, J.S.4
-
17
-
-
33748376498
-
Spatial domain method for the design of RF pulses in multicoil parallel excitation
-
Grissom W, Yip CY, Zhang Z, Stenger VA, Fessler JA, Noll DC,. Spatial domain method for the design of RF pulses in multicoil parallel excitation. Magn Reson Med. 2006; 56: 620-629.
-
(2006)
Magn Reson Med.
, vol.56
, pp. 620-629
-
-
Grissom, W.1
Yip, C.Y.2
Zhang, Z.3
Stenger, V.A.4
Fessler, J.A.5
Noll, D.C.6
-
18
-
-
84896546229
-
Local specific absorption rate (SAR), global SAR, transmitter power, and excitation accuracy trade-offs in low flip-angle parallel transmit pulse design
-
Guérin B, Gebhardt M, Cauley S, Adalsteinsson E, Wald LL,. Local specific absorption rate (SAR), global SAR, transmitter power, and excitation accuracy trade-offs in low flip-angle parallel transmit pulse design. Magn Reson Med 2014; 71: 1446-1457
-
(2014)
Magn Reson Med
, vol.71
, pp. 1446-1457
-
-
Guérin, B.1
Gebhardt, M.2
Cauley, S.3
Adalsteinsson, E.4
Wald, L.L.5
-
19
-
-
84861233288
-
Local SAR in parallel transmission pulse design
-
Lee J, Gebhardt M, Wald LL, Adalsteinsson E,. Local SAR in parallel transmission pulse design. Magn Reson Med 2011; 67: 1566-1578.
-
(2011)
Magn Reson Med
, vol.67
, pp. 1566-1578
-
-
Lee, J.1
Gebhardt, M.2
Wald, L.L.3
Adalsteinsson, E.4
-
20
-
-
67650088538
-
SAR and power implications of different RF shimming strategies in the pelvis for 7T MRI
-
van den Bergen B, van den Berg CAT, Klomp DW, Lagendijk JJ,. SAR and power implications of different RF shimming strategies in the pelvis for 7T MRI. J Magn Reson Imaging 2009; 30: 194-202.
-
(2009)
J Magn Reson Imaging
, vol.30
, pp. 194-202
-
-
Van Den Bergen, B.1
Van Den Berg, C.A.T.2
Klomp, D.W.3
Lagendijk, J.J.4
-
21
-
-
84896282198
-
On variant strategies to solve the magnitude least squares optimization problem in parallel transmission pulse design and under strict SAR and power constraints
-
Hoyos-Idrobo A, Weiss P, Massire A, Amadon A, Boulant N,. On variant strategies to solve the magnitude least squares optimization problem in parallel transmission pulse design and under strict SAR and power constraints. IEEE Trans Med Imag 2014; 33: 739-748.
-
(2014)
IEEE Trans Med Imag
, vol.33
, pp. 739-748
-
-
Hoyos-Idrobo, A.1
Weiss, P.2
Massire, A.3
Amadon, A.4
Boulant, N.5
-
22
-
-
84928079778
-
Parallel transmit pulse design with implant-friendly modes
-
Salt Lake City, Utah, USA
-
Eryaman Y, Guerin B, Adalsteinsson E, Wald LL,. Parallel transmit pulse design with implant-friendly modes. In Proceedings of the 21th Annual Meeting of ISMRM, Salt Lake City, Utah, USA, 2013. p. 2215.
-
(2013)
Proceedings of the 21th Annual Meeting of ISMRM
, pp. 2215
-
-
Eryaman, Y.1
Guerin, B.2
Adalsteinsson, E.3
Wald, L.L.4
-
23
-
-
84874370338
-
Controlling induced currents in guidewires using parallel transmit
-
Stockholm, Sweden
-
Etezadi-Amoli M, Stang P, Zanchi MG, Pauly JM, Scott GC, Kerr AB,. Controlling induced currents in guidewires using parallel transmit. In Proceedings of the 18th Annual Meeting of ISMRM, Stockholm, Sweden, 2010. p. 777.
-
(2010)
Proceedings of the 18th Annual Meeting of ISMRM
, pp. 777
-
-
Etezadi-Amoli, M.1
Stang, P.2
Zanchi, M.G.3
Pauly, J.M.4
Scott, G.C.5
Kerr, A.B.6
-
24
-
-
84872397956
-
Evaluation of the RF heating of a generic deep brain stimulator exposed in 1.5 T magnetic resonance scanners
-
Cabot E, Lloyd T, Christ A, Kainz W, Douglas M, Stenzel G, Wedan S, Kuster N,. Evaluation of the RF heating of a generic deep brain stimulator exposed in 1.5 T magnetic resonance scanners. Bioelectromagnetics 2013; 34: 104-113.
-
(2013)
Bioelectromagnetics
, vol.34
, pp. 104-113
-
-
Cabot, E.1
Lloyd, T.2
Christ, A.3
Kainz, W.4
Douglas, M.5
Stenzel, G.6
Wedan, S.7
Kuster, N.8
-
25
-
-
80054808213
-
Local specific absorption rate control for parallel transmission by virtual observation points
-
Eichfelder G, Gebhardt M,. Local specific absorption rate control for parallel transmission by virtual observation points. Magn Reson Med 2011; 66: 1468-1476.
-
(2011)
Magn Reson Med
, vol.66
, pp. 1468-1476
-
-
Eichfelder, G.1
Gebhardt, M.2
-
27
-
-
84923209521
-
Offline impedance measurements for detection and mitigation of dangerous implant interactions: An RF safety prescreen
-
Ellenor CW, Stang PP, Etezadi-Amoli M, Pauly JM, Scott GC,. Offline impedance measurements for detection and mitigation of dangerous implant interactions: an RF safety prescreen. Magn Reson Med 2015; 73: 1328-1339.
-
(2015)
Magn Reson Med
, vol.73
, pp. 1328-1339
-
-
Ellenor, C.W.1
Stang, P.P.2
Etezadi-Amoli, M.3
Pauly, J.M.4
Scott, G.C.5
-
28
-
-
77954683399
-
Determination of electric conductivity and local SAR via B1 mapping
-
Katscher U, Voigt, T, Findeklee C, Vernickel P, Nehrke K, Dossel O,. Determination of electric conductivity and local SAR via B1 mapping. IEEE Trans Med Imaging 2009; 28: 1365-1374.
-
(2009)
IEEE Trans Med Imaging
, vol.28
, pp. 1365-1374
-
-
Katscher, U.1
Voigt, T.2
Findeklee, C.3
Vernickel, P.4
Nehrke, K.5
Dossel, O.6
-
29
-
-
84928079777
-
The Ultimate SNR and SAR in Realistic Body Models
-
Milan, Italy
-
Guerin B, Villena JF, Polimeridis AG, Adalsteinsson E, Daniel L, White J, Wald LL,. The Ultimate SNR and SAR in Realistic Body Models. In Proceedings of the Joint Annual Meeting of ISMRM, Milan, Italy, 2014. p. 617.
-
(2014)
Proceedings of the Joint Annual Meeting of ISMRM
, pp. 617
-
-
Guerin, B.1
Villena, J.F.2
Polimeridis, A.G.3
Adalsteinsson, E.4
Daniel, L.5
White, J.6
Wald, L.L.7
-
30
-
-
60549086626
-
Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitations
-
Lattanzi R, Sodickson DK, Grant AK, Zhu Y,. Electrodynamic constraints on homogeneity and radiofrequency power deposition in multiple coil excitations. Magn Reson Med 2009; 61: 315-334.
-
(2009)
Magn Reson Med
, vol.61
, pp. 315-334
-
-
Lattanzi, R.1
Sodickson, D.K.2
Grant, A.K.3
Zhu, Y.4
-
31
-
-
84923175086
-
Comparison of simulated parallel transmit body arrays at 3 T using excitation uniformity, global SAR, local SAR, and power efficiency metrics
-
Guerin B, Gebhardt M, Serano P, Adalsteinsson E, Hamm M, Pfeuffer J, Nistler J, Wald LL,. Comparison of simulated parallel transmit body arrays at 3 T using excitation uniformity, global SAR, local SAR, and power efficiency metrics. Magn Reson Med 2015; 73: 1137-1150.
-
(2015)
Magn Reson Med
, vol.73
, pp. 1137-1150
-
-
Guerin, B.1
Gebhardt, M.2
Serano, P.3
Adalsteinsson, E.4
Hamm, M.5
Pfeuffer, J.6
Nistler, J.7
Wald, L.L.8
-
32
-
-
74549114118
-
The virtual family - Development of surface-based anatomical models of two adults and two children for dosimetric simulations
-
Christ A, Kainz W, Hahn EG, et al. The virtual family-development of surface-based anatomical models of two adults and two children for dosimetric simulations. Phys Med Biol 2010; 55: N23-N38.
-
(2010)
Phys Med Biol
, vol.55
, pp. N23-N38
-
-
Christ, A.1
Kainz, W.2
Hahn, E.G.3
-
33
-
-
0034070037
-
Quick HH reduction of resonant RF heating in intravascular catheters using coaxial chokes
-
Ladd ME,. Quick HH reduction of resonant RF heating in intravascular catheters using coaxial chokes. Magn Reson Med 2000; 43: 615-619.
-
(2000)
Magn Reson Med
, vol.43
, pp. 615-619
-
-
Ladd, M.E.1
|