메뉴 건너뛰기




Volumn 74, Issue C, 2014, Pages 941-949

Spectrally corrected direct normal irradiance based on artificial neural networks for high concentrator photovoltaic applications

Author keywords

Artificial neural networks; Electrical characterization; High concentrator photovoltaic technology; Spectrally corrected direct normal irradiance

Indexed keywords

CONCENTRATION (PROCESS); ELECTRIC NETWORK PARAMETERS; INCIDENT SOLAR RADIATION; MEAN SQUARE ERROR; MULTI-JUNCTION SOLAR CELLS; SOLAR POWER GENERATION;

EID: 84927689924     PISSN: 03605442     EISSN: None     Source Type: Journal    
DOI: 10.1016/j.energy.2014.07.075     Document Type: Article
Times cited : (23)

References (53)
  • 2
    • 79955490293 scopus 로고    scopus 로고
    • Concentrated solar energy applications using fresnel lenses: a review
    • Xie W.T., Dai Y.J., Wang R.Z., Sumathy K. Concentrated solar energy applications using fresnel lenses: a review. Renew Sustain Energy Rev 2011, 15(1):2588-2606.
    • (2011) Renew Sustain Energy Rev , vol.15 , Issue.1 , pp. 2588-2606
    • Xie, W.T.1    Dai, Y.J.2    Wang, R.Z.3    Sumathy, K.4
  • 3
    • 65149095633 scopus 로고    scopus 로고
    • Comparative analysis of different secondary optical elements for aspheric primary lenses
    • Victoria M., Dominguez C., Antón I., Sala G. Comparative analysis of different secondary optical elements for aspheric primary lenses. Opt Express 2009, 17(8):6487-6492.
    • (2009) Opt Express , vol.17 , Issue.8 , pp. 6487-6492
    • Victoria, M.1    Dominguez, C.2    Antón, I.3    Sala, G.4
  • 4
    • 84876702149 scopus 로고    scopus 로고
    • Atwo subcell equivalent solar cell model for III-V triple junction solar cells under spectrum and temperature variations
    • Fernández E.F., Siefer G., Almonacid F., García-Loureiro A., Pérez-Higueras P. Atwo subcell equivalent solar cell model for III-V triple junction solar cells under spectrum and temperature variations. Sol Energy 2013, 92:221-229.
    • (2013) Sol Energy , vol.92 , pp. 221-229
    • Fernández, E.F.1    Siefer, G.2    Almonacid, F.3    García-Loureiro, A.4    Pérez-Higueras, P.5
  • 5
    • 42249097083 scopus 로고    scopus 로고
    • Fill factor as a probe of current-matching for GaInP2/GaAs tandem cells in a concentrator system during outdoor operation
    • McMahon W., Emery K., Friedman D., Ottoson L., Young M., Ward J., et al. Fill factor as a probe of current-matching for GaInP2/GaAs tandem cells in a concentrator system during outdoor operation. Prog Photovoltaics Res Appl 2008, 16:213-224.
    • (2008) Prog Photovoltaics Res Appl , vol.16 , pp. 213-224
    • McMahon, W.1    Emery, K.2    Friedman, D.3    Ottoson, L.4    Young, M.5    Ward, J.6
  • 6
    • 84878192388 scopus 로고    scopus 로고
    • Outdoor evaluation of concentrator photovoltaic systems modules from different manufacturers: first results and steps
    • Fernández E.F., Pérez-Higueras P., García Loureiro A., Vidal P. Outdoor evaluation of concentrator photovoltaic systems modules from different manufacturers: first results and steps. Prog Photovoltaics Res Appl 2013, 21(4):693-701.
    • (2013) Prog Photovoltaics Res Appl , vol.21 , Issue.4 , pp. 693-701
    • Fernández, E.F.1    Pérez-Higueras, P.2    García Loureiro, A.3    Vidal, P.4
  • 7
    • 84877090658 scopus 로고    scopus 로고
    • Performance of CPV system using three different types of III-V multi-junction solar cells
    • Hashimoto J., Kurtz S., Keiichiro S., Muller M., Otani K. Performance of CPV system using three different types of III-V multi-junction solar cells. AIP conference proceedings 2012, vol. 1477:372-376.
    • (2012) AIP conference proceedings , vol.1477 , pp. 372-376
    • Hashimoto, J.1    Kurtz, S.2    Keiichiro, S.3    Muller, M.4    Otani, K.5
  • 8
    • 84880381795 scopus 로고    scopus 로고
    • Models for the electrical characterization of high concentration photovoltaic cells and modules: a review
    • Rodrigo P., Fernández E.F., Almonacid F., Pérez-Higueras P. Models for the electrical characterization of high concentration photovoltaic cells and modules: a review. Renew Sustain Energy Rev 2013, 26:752-760.
    • (2013) Renew Sustain Energy Rev , vol.26 , pp. 752-760
    • Rodrigo, P.1    Fernández, E.F.2    Almonacid, F.3    Pérez-Higueras, P.4
  • 10
    • 79960564710 scopus 로고    scopus 로고
    • Amethod for using CPV modules as temperature sensors and its application to rating procedures
    • Peharz G., Ferrer Rodríguez J., Siefer G., Bett A. Amethod for using CPV modules as temperature sensors and its application to rating procedures. Sol Energy Mater Sol Cells 2011, 95:2734-2744.
    • (2011) Sol Energy Mater Sol Cells , vol.95 , pp. 2734-2744
    • Peharz, G.1    Ferrer Rodríguez, J.2    Siefer, G.3    Bett, A.4
  • 11
    • 84872038963 scopus 로고    scopus 로고
    • Characterization of concentrating photovoltaic modules by cooperative competitive radial basis function networks
    • Rivera A., García-Domingo B., del Jesús M., Aguilera J. Characterization of concentrating photovoltaic modules by cooperative competitive radial basis function networks. Expert Syst Appl 2013, 40:1599-1608.
    • (2013) Expert Syst Appl , vol.40 , pp. 1599-1608
    • Rivera, A.1    García-Domingo, B.2    del Jesús, M.3    Aguilera, J.4
  • 12
    • 84876092251 scopus 로고    scopus 로고
    • Estimating the maximum power of a high concentrator photovoltaic (HCPV) module using an artificial neural Network
    • Almonacid F., Fernández E.F., Rodrigo P., Pérez-Higueras P., Rus-Casas C. Estimating the maximum power of a high concentrator photovoltaic (HCPV) module using an artificial neural Network. Energy 2013, 53:165-172.
    • (2013) Energy , vol.53 , pp. 165-172
    • Almonacid, F.1    Fernández, E.F.2    Rodrigo, P.3    Pérez-Higueras, P.4    Rus-Casas, C.5
  • 13
    • 84883236425 scopus 로고    scopus 로고
    • Model for prediction of the maximum power point of a high concentrator photovoltaic module
    • Fernández E.F., Almonacid F., Rodrigo P., Pérez-Higueras P. Model for prediction of the maximum power point of a high concentrator photovoltaic module. Sol Energy 2013, 97:12-18.
    • (2013) Sol Energy , vol.97 , pp. 12-18
    • Fernández, E.F.1    Almonacid, F.2    Rodrigo, P.3    Pérez-Higueras, P.4
  • 17
    • 84924065169 scopus 로고    scopus 로고
    • YieldOpt, a model to predict the power output and energy yield for concentrating photovoltaic modules
    • Steiner M., Siefer G., Hornung T., Peharz G., Bett A.W. YieldOpt, a model to predict the power output and energy yield for concentrating photovoltaic modules. Prog Photovoltaics Res Appl 2014, 10.1002/pip.2458.
    • (2014) Prog Photovoltaics Res Appl
    • Steiner, M.1    Siefer, G.2    Hornung, T.3    Peharz, G.4    Bett, A.W.5
  • 20
    • 84885959414 scopus 로고    scopus 로고
    • Outdoor measurement of high concentration photovoltaic receivers operating with partial shading on the primary optics
    • Rodrigo P., Fernández E.F., Almonacid F., Pérez-Higueras P. Outdoor measurement of high concentration photovoltaic receivers operating with partial shading on the primary optics. Energy 2013, 61:583-588.
    • (2013) Energy , vol.61 , pp. 583-588
    • Rodrigo, P.1    Fernández, E.F.2    Almonacid, F.3    Pérez-Higueras, P.4
  • 21
    • 67651091507 scopus 로고    scopus 로고
    • Asimple method for quantifying spectral impacts on multi-junction solar cells
    • Peharz G., Siefer G., Bett A. Asimple method for quantifying spectral impacts on multi-junction solar cells. Sol Energy 2009, 83:1588-1589.
    • (2009) Sol Energy , vol.83 , pp. 1588-1589
    • Peharz, G.1    Siefer, G.2    Bett, A.3
  • 22
    • 84975571774 scopus 로고
    • Revised optical air mass tables an approximation formula
    • Kasten F., Young A.T. Revised optical air mass tables an approximation formula. Appl Opt 1989, 28(22):4735-4738.
    • (1989) Appl Opt , vol.28 , Issue.22 , pp. 4735-4738
    • Kasten, F.1    Young, A.T.2
  • 23
    • 0026172409 scopus 로고
    • The influence of spectral solar irradiance variations on the performance of selected single-junction and multi-junctions solar cells
    • Faine P., Kurtz S., Riordan C., Olson J.M. The influence of spectral solar irradiance variations on the performance of selected single-junction and multi-junctions solar cells. Sol Cells 1991, 31:259-278.
    • (1991) Sol Cells , vol.31 , pp. 259-278
    • Faine, P.1    Kurtz, S.2    Riordan, C.3    Olson, J.M.4
  • 24
    • 84901300707 scopus 로고    scopus 로고
    • Analysis of the spectral variations on the performance of high concentrator photovoltaic modules operating under different real climate conditions
    • Fernandez E.F., Almonacid F., Ruiz-Arias J.A., Soria-Moya A. Analysis of the spectral variations on the performance of high concentrator photovoltaic modules operating under different real climate conditions. Sol Energy Mater Sol Cells 2014, 127:179-187.
    • (2014) Sol Energy Mater Sol Cells , vol.127 , pp. 179-187
    • Fernandez, E.F.1    Almonacid, F.2    Ruiz-Arias, J.A.3    Soria-Moya, A.4
  • 25
    • 84901287615 scopus 로고    scopus 로고
    • Photovoltaic module calibration value versus optical air mass: The air mass function
    • Osterwald C.R., Emery K.A., Muller M. Photovoltaic module calibration value versus optical air mass: The air mass function. Prog Photovoltaics Res Appl 2014, 22(5):560-573.
    • (2014) Prog Photovoltaics Res Appl , vol.22 , Issue.5 , pp. 560-573
    • Osterwald, C.R.1    Emery, K.A.2    Muller, M.3
  • 27
    • 77952750017 scopus 로고    scopus 로고
    • Multijunction solar cell model for translating I-V characteristics as a function of irradiance, spectrum, and cell temperature
    • Domínguez C., Antón I., Sala G. Multijunction solar cell model for translating I-V characteristics as a function of irradiance, spectrum, and cell temperature. Prog Photovoltaics Res Appl 2010, 18(4):272-284.
    • (2010) Prog Photovoltaics Res Appl , vol.18 , Issue.4 , pp. 272-284
    • Domínguez, C.1    Antón, I.2    Sala, G.3
  • 31
    • 0037300790 scopus 로고    scopus 로고
    • Short-term characterization of building integrated photovoltaic panels
    • Fanney A., Dougherty B., Davis B. Short-term characterization of building integrated photovoltaic panels. JSol Energy Eng 2003, 125:13-20.
    • (2003) JSol Energy Eng , vol.125 , pp. 13-20
    • Fanney, A.1    Dougherty, B.2    Davis, B.3
  • 33
    • 78649310508 scopus 로고    scopus 로고
    • An investigation into spectral parameters as they impact CPV module performance
    • Muller M., Marion B., Kurtz S., Rodriguez J. An investigation into spectral parameters as they impact CPV module performance. AIP conference proceedings 2010, vol. 1277:307-311.
    • (2010) AIP conference proceedings , vol.1277 , pp. 307-311
    • Muller, M.1    Marion, B.2    Kurtz, S.3    Rodriguez, J.4
  • 34
    • 56049088497 scopus 로고    scopus 로고
    • Characterisation of a Si-crystalline PV modules by artificial neural networks
    • Almonacid F., Rus C., Pérez P., Hontoria L. Characterisation of a Si-crystalline PV modules by artificial neural networks. Renew Energy 2009, 34(4):941-949.
    • (2009) Renew Energy , vol.34 , Issue.4 , pp. 941-949
    • Almonacid, F.1    Rus, C.2    Pérez, P.3    Hontoria, L.4
  • 35
    • 68049137320 scopus 로고    scopus 로고
    • Estimation of the energy of a PV generator using artificial neural network
    • Almonacid F., Rus C., Pérez P., Hontoria L. Estimation of the energy of a PV generator using artificial neural network. Renew Energy 2009, 34(12):2743-2750.
    • (2009) Renew Energy , vol.34 , Issue.12 , pp. 2743-2750
    • Almonacid, F.1    Rus, C.2    Pérez, P.3    Hontoria, L.4
  • 36
    • 73249138360 scopus 로고    scopus 로고
    • Characterisation of PV CIS module by artificial neural networks. A comparative study with other methods
    • Almonacid F., Rus C., Hontoria L., Muñoz F.J. Characterisation of PV CIS module by artificial neural networks. A comparative study with other methods. Renew Energy 2010, 35(5):973-980.
    • (2010) Renew Energy , vol.35 , Issue.5 , pp. 973-980
    • Almonacid, F.1    Rus, C.2    Hontoria, L.3    Muñoz, F.J.4
  • 37
    • 78650733354 scopus 로고    scopus 로고
    • Calculation of the energy provided by a PV generator. Comparative study: conventional methods vs. artificial neural networks
    • Almonacid F., Rus C., Pérez-Higueras P., Hontoria L. Calculation of the energy provided by a PV generator. Comparative study: conventional methods vs. artificial neural networks. Energy 2011, 36(1):375-384.
    • (2011) Energy , vol.36 , Issue.1 , pp. 375-384
    • Almonacid, F.1    Rus, C.2    Pérez-Higueras, P.3    Hontoria, L.4
  • 38
    • 80855139516 scopus 로고    scopus 로고
    • Anew method for estimating angular, spectral and low irradiance losses in photovoltaic systems using an artificial neural network model in combination with the osterwald model
    • Rodrigo P., Rus C., Almonacid F., Pérez-Higueras P., Almonacid G. Anew method for estimating angular, spectral and low irradiance losses in photovoltaic systems using an artificial neural network model in combination with the osterwald model. Sol Energy Mater Sol Cells 2012, 96(1):186-194.
    • (2012) Sol Energy Mater Sol Cells , vol.96 , Issue.1 , pp. 186-194
    • Rodrigo, P.1    Rus, C.2    Almonacid, F.3    Pérez-Higueras, P.4    Almonacid, G.5
  • 39
    • 84888591771 scopus 로고    scopus 로고
    • Calculation of the cell temperature of a high concentrator (HCPV) module: a study and comparison of different methods
    • Fernández E.F., Almonacid F., Rodrigo P., Pérez-Higueras P. Calculation of the cell temperature of a high concentrator (HCPV) module: a study and comparison of different methods. Sol Energy Mater Sol Cells 2014, 121:144-151.
    • (2014) Sol Energy Mater Sol Cells , vol.121 , pp. 144-151
    • Fernández, E.F.1    Almonacid, F.2    Rodrigo, P.3    Pérez-Higueras, P.4
  • 40
    • 84891053883 scopus 로고    scopus 로고
    • Amodel based on artificial neural network for the prediction of the maximum power of a low concentrator photovoltaic module for building integration
    • Fernández E.F., Almonacid F., Sarmah N., Rodrigo P., Mallick T., Pérez-Higueras P. Amodel based on artificial neural network for the prediction of the maximum power of a low concentrator photovoltaic module for building integration. Sol Energy 2014, 100:148-158.
    • (2014) Sol Energy , vol.100 , pp. 148-158
    • Fernández, E.F.1    Almonacid, F.2    Sarmah, N.3    Rodrigo, P.4    Mallick, T.5    Pérez-Higueras, P.6
  • 41
    • 84894541155 scopus 로고    scopus 로고
    • Amethod for estimating cell temperature at the maximum power point of a HCPV module under actual operating conditions
    • Fernández E.F., Rodrigo P., Almonacid F., Pérez-Higueras P. Amethod for estimating cell temperature at the maximum power point of a HCPV module under actual operating conditions. Sol Energy Mater Sol Cells 2014, 124:159-165.
    • (2014) Sol Energy Mater Sol Cells , vol.124 , pp. 159-165
    • Fernández, E.F.1    Rodrigo, P.2    Almonacid, F.3    Pérez-Higueras, P.4
  • 42
    • 85067759004 scopus 로고    scopus 로고
    • MODIS daily Level-3 data. Available from: [accessed 2013].
    • MODIS daily Level-3 data. Available from: [accessed 2013]. http://gdata1.sci.gsfc.nasa.gov/daac-bin/G3/gui.cgi?instance:id=MODIS_DAILY_L3.
  • 44
    • 0000873069 scopus 로고
    • Amethod for the solution of certain problems in least squares
    • Levenberg K. Amethod for the solution of certain problems in least squares. QAppl Math 1944, 2:164-168.
    • (1944) QAppl Math , vol.2 , pp. 164-168
    • Levenberg, K.1
  • 45
    • 0000169232 scopus 로고
    • An algorithm for least-squares estimation of nonlinear parameters
    • Marquardt D. An algorithm for least-squares estimation of nonlinear parameters. SIAM J Appl Math 1963, 11:431-441.
    • (1963) SIAM J Appl Math , vol.11 , pp. 431-441
    • Marquardt, D.1
  • 46
    • 0024866495 scopus 로고
    • On the approximate realisation of continuous mappings by neural networks
    • Funahashi K. On the approximate realisation of continuous mappings by neural networks. Neural Netw 1989, 2:183-192.
    • (1989) Neural Netw , vol.2 , pp. 183-192
    • Funahashi, K.1
  • 47
    • 0027662338 scopus 로고
    • Pruning algorithms - a survey
    • Reed R. Pruning algorithms - a survey. IEEE Trans Neural Networks 1993, 4(5):740-747.
    • (1993) IEEE Trans Neural Networks , vol.4 , Issue.5 , pp. 740-747
    • Reed, R.1
  • 48
    • 0029184907 scopus 로고
    • The classification of power system disturbance waveforms using a neural network approach
    • Ghoshy A., Lubkeman D. The classification of power system disturbance waveforms using a neural network approach. IEEE Trans Power Deliv 1995, 10(1):109-115.
    • (1995) IEEE Trans Power Deliv , vol.10 , Issue.1 , pp. 109-115
    • Ghoshy, A.1    Lubkeman, D.2
  • 50
    • 26844455787 scopus 로고    scopus 로고
    • Model selection in neural networks: some difficulties
    • Curry B., Morgan P. Model selection in neural networks: some difficulties. Eur J Oper Res 2006, 170(2):567-577.
    • (2006) Eur J Oper Res , vol.170 , Issue.2 , pp. 567-577
    • Curry, B.1    Morgan, P.2
  • 51
    • 77949876934 scopus 로고    scopus 로고
    • A24-h forecast of solar irradiance using artificial neural network: application for performance prediction of a grid-connected PV plant at Trieste, Italy
    • Mellit A., Pavan A.M. A24-h forecast of solar irradiance using artificial neural network: application for performance prediction of a grid-connected PV plant at Trieste, Italy. Sol Energy 2010, 84:807-821.
    • (2010) Sol Energy , vol.84 , pp. 807-821
    • Mellit, A.1    Pavan, A.M.2
  • 53
    • 0034963531 scopus 로고    scopus 로고
    • Artificial Neural Network in renewable energy system application: a review
    • Kalogirou S. Artificial Neural Network in renewable energy system application: a review. Renew Sustain Energy Rev 2001, 5:373-401.
    • (2001) Renew Sustain Energy Rev , vol.5 , pp. 373-401
    • Kalogirou, S.1


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.