메뉴 건너뛰기




Volumn 41, Issue 5, 2015, Pages 1402-1410

Sonothrombolysis: The Contribution of Stable and Inertial Cavitation to Clot Lysis

Author keywords

Fibrinolysis; Human blood clot; Inertial cavitation; Ischemic stroke; Microbubbles; Radiolabeled fibrinogen; Recombinant tissue plasminogen activator; Sonothrombolysis; Stable cavitation; Ultrasound

Indexed keywords

BLOOD; COMPLEX NETWORKS; DEGRADATION; PHOSPHOLIPIDS; TISSUE; ULTRASONICS;

EID: 84927574268     PISSN: 03015629     EISSN: 1879291X     Source Type: Journal    
DOI: 10.1016/j.ultrasmedbio.2014.12.007     Document Type: Article
Times cited : (72)

References (42)
  • 1
    • 84882428477 scopus 로고    scopus 로고
    • Interactions between ultrasound stimulated microbubbles and fibrin clots
    • Acconcia C., Leung B.Y.C., Hynynen K., Goertz D.E. Interactions between ultrasound stimulated microbubbles and fibrin clots. Appl Phys Lett 2013, 103:053701.
    • (2013) Appl Phys Lett , vol.103 , pp. 053701
    • Acconcia, C.1    Leung, B.Y.C.2    Hynynen, K.3    Goertz, D.E.4
  • 3
    • 79751529767 scopus 로고    scopus 로고
    • Microbubbles improve sonothrombolysis invitro and decrease hemorrhage invivo in a rabbit stroke model
    • Brown A.T., Flores R., Hamilton E., Roberson P.K., Borrelli M.J., Culp W.C. Microbubbles improve sonothrombolysis invitro and decrease hemorrhage invivo in a rabbit stroke model. Invest Radiol 2011, 46:202-207.
    • (2011) Invest Radiol , vol.46 , pp. 202-207
    • Brown, A.T.1    Flores, R.2    Hamilton, E.3    Roberson, P.K.4    Borrelli, M.J.5    Culp, W.C.6
  • 5
    • 0038076078 scopus 로고    scopus 로고
    • Inertial cavitation dose and hemolysis produced invitro with or without Optison
    • Chen W.S., Brayman A.A., Matula T.J., Crum L.A. Inertial cavitation dose and hemolysis produced invitro with or without Optison. Ultrasound Med Biol 2003, 29:725-737.
    • (2003) Ultrasound Med Biol , vol.29 , pp. 725-737
    • Chen, W.S.1    Brayman, A.A.2    Matula, T.J.3    Crum, L.A.4
  • 7
    • 27644539775 scopus 로고    scopus 로고
    • Significance of susceptibility vessel sign on T2*-weighted gradient echo imaging for identification of stroke subtypes
    • Cho K.H., Kim J.S., Kwon S.U., Cho A.H., Kang D.W. Significance of susceptibility vessel sign on T2*-weighted gradient echo imaging for identification of stroke subtypes. Stroke 2005, 36:2379-2383.
    • (2005) Stroke , vol.36 , pp. 2379-2383
    • Cho, K.H.1    Kim, J.S.2    Kwon, S.U.3    Cho, A.H.4    Kang, D.W.5
  • 8
    • 13244298176 scopus 로고    scopus 로고
    • Enhancement of enzymatic fibrinolysis with 2-MHz ultrasound and microbubbles
    • Cintas P., Nguyen F., Boneu B., Larrue V. Enhancement of enzymatic fibrinolysis with 2-MHz ultrasound and microbubbles. JThromb Haemost 2004, 2:1163-1166.
    • (2004) JThromb Haemost , vol.2 , pp. 1163-1166
    • Cintas, P.1    Nguyen, F.2    Boneu, B.3    Larrue, V.4
  • 13
    • 0030983613 scopus 로고    scopus 로고
    • Correlation of ultrasound-induced hemolysis with cavitation detector output invitro
    • Everbach E.C., Makin I.R., Azadniv M., Meltzer R.S. Correlation of ultrasound-induced hemolysis with cavitation detector output invitro. Ultrasound Med Biol 1997, 23:619-624.
    • (1997) Ultrasound Med Biol , vol.23 , pp. 619-624
    • Everbach, E.C.1    Makin, I.R.2    Azadniv, M.3    Meltzer, R.S.4
  • 15
    • 79959948167 scopus 로고    scopus 로고
    • Microbubble-augmented ultrasound sonothrombolysis decreases intracranial hemorrhage in a rabbit model of acute ischemic stroke
    • Flores R., Hennings L.J., Lowery J.D., Brown A.T., Culp W.C. Microbubble-augmented ultrasound sonothrombolysis decreases intracranial hemorrhage in a rabbit model of acute ischemic stroke. Invest Radiol 2011, 46:419-424.
    • (2011) Invest Radiol , vol.46 , pp. 419-424
    • Flores, R.1    Hennings, L.J.2    Lowery, J.D.3    Brown, A.T.4    Culp, W.C.5
  • 17
    • 0025258575 scopus 로고
    • Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment
    • Holland C.K., Apfel R.E. Thresholds for transient cavitation produced by pulsed ultrasound in a controlled nuclei environment. JAcoust Soc Am 1990, 88:2059-2069.
    • (1990) JAcoust Soc Am , vol.88 , pp. 2059-2069
    • Holland, C.K.1    Apfel, R.E.2
  • 18
    • 33749525135 scopus 로고    scopus 로고
    • Correlation between inertial cavitation dose and endothelial cell damage invivo
    • Hwang J.H., Tu J., Brayman A.A., Matula T.J., Crum L.A. Correlation between inertial cavitation dose and endothelial cell damage invivo. Ultrasound Med Biol 2006, 32:1611-1619.
    • (2006) Ultrasound Med Biol , vol.32 , pp. 1611-1619
    • Hwang, J.H.1    Tu, J.2    Brayman, A.A.3    Matula, T.J.4    Crum, L.A.5
  • 19
    • 0006752634 scopus 로고
    • The forced bubble
    • Academic Press, London
    • Leighton T.G. The forced bubble. The acoustic bubble 1994, 287-438. Academic Press, London.
    • (1994) The acoustic bubble , pp. 287-438
    • Leighton, T.G.1
  • 22
    • 0030442881 scopus 로고    scopus 로고
    • Areview of invitro bioeffects of inertial ultrasonic cavitation from a mechanistic perspective
    • Miller M.W., Miller D.L., Brayman A.A. Areview of invitro bioeffects of inertial ultrasonic cavitation from a mechanistic perspective. Ultrasound Med Biol 1996, 22:1131-1154.
    • (1996) Ultrasound Med Biol , vol.22 , pp. 1131-1154
    • Miller, M.W.1    Miller, D.L.2    Brayman, A.A.3
  • 24
    • 0842267578 scopus 로고    scopus 로고
    • Differential pattern of tissue plasminogen activator-induced proximal middle cerebral artery recanalization among stroke subtypes
    • Molina C.A., Montaner J., Arenillas J.F., Ribo M., Rubiera M., Alvarez-Sabin J. Differential pattern of tissue plasminogen activator-induced proximal middle cerebral artery recanalization among stroke subtypes. Stroke 2004, 35:486-490.
    • (2004) Stroke , vol.35 , pp. 486-490
    • Molina, C.A.1    Montaner, J.2    Arenillas, J.F.3    Ribo, M.4    Rubiera, M.5    Alvarez-Sabin, J.6
  • 26
    • 28344448202 scopus 로고    scopus 로고
    • Fibrinogen and fibrin structure and functions
    • Mosesson M.W. Fibrinogen and fibrin structure and functions. JThromb Haemost 2005, 3:1894-1904.
    • (2005) JThromb Haemost , vol.3 , pp. 1894-1904
    • Mosesson, M.W.1
  • 28
    • 45949127155 scopus 로고
    • Acoustic cavitation
    • Neppiras E.A. Acoustic cavitation. Phys Rep 1980, 61:159-161.
    • (1980) Phys Rep , vol.61 , pp. 159-161
    • Neppiras, E.A.1
  • 29
    • 42549110330 scopus 로고    scopus 로고
    • Microbubble potentiated transcranial duplex ultrasound enhances IV thrombolysis in acute stroke
    • Perren F., Loulidi J., Poglia D., Landis T., Sztajzel R. Microbubble potentiated transcranial duplex ultrasound enhances IV thrombolysis in acute stroke. JThromb Thrombolysis 2008, 25:219-223.
    • (2008) JThromb Thrombolysis , vol.25 , pp. 219-223
    • Perren, F.1    Loulidi, J.2    Poglia, D.3    Landis, T.4    Sztajzel, R.5
  • 32
    • 34249288983 scopus 로고    scopus 로고
    • Cavitational mechanisms in ultrasound-accelerated fibrinolysis
    • Prokop A.F., Soltani A., Roy R.A. Cavitational mechanisms in ultrasound-accelerated fibrinolysis. Ultrasound Med Biol 2007, 33:924-933.
    • (2007) Ultrasound Med Biol , vol.33 , pp. 924-933
    • Prokop, A.F.1    Soltani, A.2    Roy, R.A.3
  • 34
    • 77049120794 scopus 로고    scopus 로고
    • Long-term stability of recombinant tissue plasminogen activator at -80 C
    • Shaw G.J., Sperling M., Meunier J.M. Long-term stability of recombinant tissue plasminogen activator at -80 C. BMC Res Notes 2009, 2:117.
    • (2009) BMC Res Notes , vol.2 , pp. 117
    • Shaw, G.J.1    Sperling, M.2    Meunier, J.M.3
  • 36
    • 0029154850 scopus 로고
    • Albumin microbubble echo-contrast material as an enhancer for ultrasound accelerated thrombolysis
    • Tachibana K., Tachibana S. Albumin microbubble echo-contrast material as an enhancer for ultrasound accelerated thrombolysis. Circulation 1995, 92:1148-1150.
    • (1995) Circulation , vol.92 , pp. 1148-1150
    • Tachibana, K.1    Tachibana, S.2
  • 37
    • 0026520542 scopus 로고
    • Pharmacokinetics and fibrin specificity of alteplase during accelerated infusions in acute myocardial infarction
    • Tanswell P., Tebbe U., Neuhaus K.L., Glasle-Schwarz L., Wojcik J., Seifried E. Pharmacokinetics and fibrin specificity of alteplase during accelerated infusions in acute myocardial infarction. JAm Coll Cardiol 1992, 19:1071-1075.
    • (1992) JAm Coll Cardiol , vol.19 , pp. 1071-1075
    • Tanswell, P.1    Tebbe, U.2    Neuhaus, K.L.3    Glasle-Schwarz, L.4    Wojcik, J.5    Seifried, E.6
  • 38
    • 78149317618 scopus 로고    scopus 로고
    • Invivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice
    • Tung Y.S., Vlachos F., Choi J.J., Deffieux T., Selert K., Konofagou E.E. Invivo transcranial cavitation threshold detection during ultrasound-induced blood-brain barrier opening in mice. Phys Med Biol 2010, 55:6141-6155.
    • (2010) Phys Med Biol , vol.55 , pp. 6141-6155
    • Tung, Y.S.1    Vlachos, F.2    Choi, J.J.3    Deffieux, T.4    Selert, K.5    Konofagou, E.E.6
  • 39
    • 34250692159 scopus 로고    scopus 로고
    • Structure of fibrin: Impact on clot stability
    • Weisel J.W. Structure of fibrin: Impact on clot stability. JThromb Haemost 2007, 5(Suppl 1):116-124.
    • (2007) JThromb Haemost , vol.5 , pp. 116-124
    • Weisel, J.W.1
  • 40
    • 44149102122 scopus 로고    scopus 로고
    • Ultrasound, cavitation bubbles and their interaction with cells
    • Wu J., Nyborg W.L. Ultrasound, cavitation bubbles and their interaction with cells. Adv Drug Deliv Rev 2008, 60:1103-1116.
    • (2008) Adv Drug Deliv Rev , vol.60 , pp. 1103-1116
    • Wu, J.1    Nyborg, W.L.2


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.