메뉴 건너뛰기




Volumn 22, Issue 5, 2015, Pages 899-904

Cortical screw trajectory for instrumentation and fusion in the setting of osteopathic compression fracture allows for percutaneous kyphoplasty for adjacent level compression fractures

Author keywords

Cortical screw trajectory; Degenerative spinal disease; Osteoporotic vertebral compression fracture; Spinal fixation

Indexed keywords

ANALGESIC AGENT;

EID: 84927176864     PISSN: 09675868     EISSN: 15322653     Source Type: Journal    
DOI: 10.1016/j.jocn.2014.09.025     Document Type: Article
Times cited : (9)

References (22)
  • 2
    • 34247194211 scopus 로고    scopus 로고
    • Incidence and economic burden of osteoporosis-related fractures in the United States, 2005-2025
    • R. Burge, B. Dawson-Hughes, and D.H. Solomon Incidence and economic burden of osteoporosis-related fractures in the United States, 2005-2025 J Bone Miner Res 22 2007 465 475
    • (2007) J Bone Miner Res , vol.22 , pp. 465-475
    • Burge, R.1    Dawson-Hughes, B.2    Solomon, D.H.3
  • 3
    • 64849089881 scopus 로고    scopus 로고
    • Cortical bone trajectory for lumbar pedicle screws
    • B.G. Santoni, R.A. Hynes, and K.C. McGilvray Cortical bone trajectory for lumbar pedicle screws Spine J 9 2009 366 373
    • (2009) Spine J , vol.9 , pp. 366-373
    • Santoni, B.G.1    Hynes, R.A.2    McGilvray, K.C.3
  • 4
    • 0027304350 scopus 로고
    • Static and cyclical biomechanical analysis of pedicle screw spinal constructs
    • B.W. Cunningham, J.C. Sefter, and Y. Shono Static and cyclical biomechanical analysis of pedicle screw spinal constructs Spine (Phila Pa 1976) 18 1993 1677 1688
    • (1993) Spine (Phila Pa 1976) , vol.18 , pp. 1677-1688
    • Cunningham, B.W.1    Sefter, J.C.2    Shono, Y.3
  • 5
    • 0029906135 scopus 로고    scopus 로고
    • The relative importance of vertebral bone density and disc degeneration in spinal flexibility and interbody implant performance. An in vitro study
    • T.R. Oxland, T. Lund, and B. Jost The relative importance of vertebral bone density and disc degeneration in spinal flexibility and interbody implant performance. An in vitro study Spine (Phila Pa 1976) 21 1996 2558 2569
    • (1996) Spine (Phila Pa 1976) , vol.21 , pp. 2558-2569
    • Oxland, T.R.1    Lund, T.2    Jost, B.3
  • 6
    • 22144464068 scopus 로고    scopus 로고
    • Trabecular architecture of lumbar vertebral pedicle
    • S. Inceoglu, A. Burghardt, and A. Akbay Trabecular architecture of lumbar vertebral pedicle Spine (Phila Pa 1976) 30 2005 1485 1490
    • (2005) Spine (Phila Pa 1976) , vol.30 , pp. 1485-1490
    • Inceoglu, S.1    Burghardt, A.2    Akbay, A.3
  • 7
    • 3342928907 scopus 로고    scopus 로고
    • Biomechanical study of pedicle screw fixation in severely osteoporotic bone
    • S.D. Cook, S.L. Salkeld, and T. Stanley Biomechanical study of pedicle screw fixation in severely osteoporotic bone Spine J 4 2004 402 408
    • (2004) Spine J , vol.4 , pp. 402-408
    • Cook, S.D.1    Salkeld, S.L.2    Stanley, T.3
  • 8
    • 78650294275 scopus 로고    scopus 로고
    • Instrumentation of the osteoporotic spine: Biomechanical and clinical considerations
    • K.E. Ponnusamy, S. Iyer, and G. Gupta Instrumentation of the osteoporotic spine: biomechanical and clinical considerations Spine J 11 2011 54 63
    • (2011) Spine J , vol.11 , pp. 54-63
    • Ponnusamy, K.E.1    Iyer, S.2    Gupta, G.3
  • 9
    • 0027365874 scopus 로고
    • Stability of transpedicle screwing for the osteoporotic spine. An in vitro study of the mechanical stability
    • K. Okuyama, K. Sato, and E. Abe Stability of transpedicle screwing for the osteoporotic spine. An in vitro study of the mechanical stability Spine (Phila Pa 1976) 18 1993 2240 2245
    • (1993) Spine (Phila Pa 1976) , vol.18 , pp. 2240-2245
    • Okuyama, K.1    Sato, K.2    Abe, E.3
  • 10
    • 0028034777 scopus 로고
    • Effects of bone mineral density on pedicle screw fixation
    • T.L. Halvorson, L.A. Kelley, and K.A. Thomas Effects of bone mineral density on pedicle screw fixation Spine (Phila Pa 1976) 19 1994 2415 2420
    • (1994) Spine (Phila Pa 1976) , vol.19 , pp. 2415-2420
    • Halvorson, T.L.1    Kelley, L.A.2    Thomas, K.A.3
  • 11
    • 33846669429 scopus 로고    scopus 로고
    • Cement augmentation of vertebral screws enhances the interface strength between interbody device and vertebral body
    • J.S. Tan, C.S. Bailey, and M.F. Dvorak Cement augmentation of vertebral screws enhances the interface strength between interbody device and vertebral body Spine (Phila Pa 1976) 32 2007 334 341
    • (2007) Spine (Phila Pa 1976) , vol.32 , pp. 334-341
    • Tan, J.S.1    Bailey, C.S.2    Dvorak, M.F.3
  • 12
    • 0025903474 scopus 로고
    • Importance of bone mineral density in instrumented spine fusions
    • R.H. Wittenberg, M. Shea, and D.E. Swartz Importance of bone mineral density in instrumented spine fusions Spine (Phila Pa 1976) 16 1991 647 652
    • (1991) Spine (Phila Pa 1976) , vol.16 , pp. 647-652
    • Wittenberg, R.H.1    Shea, M.2    Swartz, D.E.3
  • 13
    • 0031419970 scopus 로고    scopus 로고
    • Structural characteristics of the pedicle and its role in screw stability
    • [discussion 2510]
    • T. Hirano, K. Hasegawa, and H.E. Takahashi Structural characteristics of the pedicle and its role in screw stability Spine (Phila Pa 1976) 22 1997 2504 2509 [discussion 2510]
    • (1997) Spine (Phila Pa 1976) , vol.22 , pp. 2504-2509
    • Hirano, T.1    Hasegawa, K.2    Takahashi, H.E.3
  • 14
    • 0035900949 scopus 로고    scopus 로고
    • Risk of new vertebral fracture in the year following a fracture
    • R. Lindsay, S.L. Silverman, and C. Cooper Risk of new vertebral fracture in the year following a fracture JAMA 285 2001 320 323
    • (2001) JAMA , vol.285 , pp. 320-323
    • Lindsay, R.1    Silverman, S.L.2    Cooper, C.3
  • 15
    • 34748879942 scopus 로고    scopus 로고
    • Percutaneous vertebral augmentation: An elevation in adjacent-level fracture risk in kyphoplasty as compared with vertebroplasty
    • B.M. Frankel, T. Monroe, and C. Wang Percutaneous vertebral augmentation: an elevation in adjacent-level fracture risk in kyphoplasty as compared with vertebroplasty Spine J 7 2007 575 582
    • (2007) Spine J , vol.7 , pp. 575-582
    • Frankel, B.M.1    Monroe, T.2    Wang, C.3
  • 16
    • 12144266672 scopus 로고    scopus 로고
    • Primary and secondary osteoporosis' incidence of subsequent vertebral compression fractures after kyphoplasty
    • J.S. Harrop, B. Prpa, and M.K. Reinhardt Primary and secondary osteoporosis' incidence of subsequent vertebral compression fractures after kyphoplasty Spine (Phila Pa 1976) 29 2004 2120 2125
    • (2004) Spine (Phila Pa 1976) , vol.29 , pp. 2120-2125
    • Harrop, J.S.1    Prpa, B.2    Reinhardt, M.K.3
  • 17
    • 84856690679 scopus 로고    scopus 로고
    • Subsequent vertebral fracture after vertebroplasty: Incidence and analysis of risk factors
    • Y.A. Li, C.L. Lin, and M.C. Chang Subsequent vertebral fracture after vertebroplasty: incidence and analysis of risk factors Spine (Phila Pa 1976) 37 2012 179 183
    • (2012) Spine (Phila Pa 1976) , vol.37 , pp. 179-183
    • Li, Y.A.1    Lin, C.L.2    Chang, M.C.3
  • 18
    • 0037648845 scopus 로고    scopus 로고
    • The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: Finite-element analysis
    • A. Polikeit, L.P. Nolte, and S.J. Ferguson The effect of cement augmentation on the load transfer in an osteoporotic functional spinal unit: finite-element analysis Spine (Phila Pa 1976) 28 2003 991 996
    • (2003) Spine (Phila Pa 1976) , vol.28 , pp. 991-996
    • Polikeit, A.1    Nolte, L.P.2    Ferguson, S.J.3
  • 19
    • 14944341603 scopus 로고    scopus 로고
    • Incidence of subsequent vertebral fracture after kyphoplasty
    • [discussion 227]
    • D. Fribourg, C. Tang, and P. Sra Incidence of subsequent vertebral fracture after kyphoplasty Spine (Phila Pa 1976) 29 2004 2270 2276 [discussion 227]
    • (2004) Spine (Phila Pa 1976) , vol.29 , pp. 2270-2276
    • Fribourg, D.1    Tang, C.2    Sra, P.3
  • 20
    • 77955385364 scopus 로고    scopus 로고
    • The biomechanics of pedicle screw-based instrumentation
    • W. Cho, S.K. Cho, and C. Wu The biomechanics of pedicle screw-based instrumentation J Bone Joint Surg Br 92 2010 1061 1065
    • (2010) J Bone Joint Surg Br , vol.92 , pp. 1061-1065
    • Cho, W.1    Cho, S.K.2    Wu, C.3
  • 21
    • 29044449457 scopus 로고    scopus 로고
    • Reduction of pain and fracture incidence after kyphoplasty: 1-year outcomes of a prospective controlled trial of patients with primary osteoporosis
    • I.A. Grafe, K. Da Fonseca, and J. Hillmeier Reduction of pain and fracture incidence after kyphoplasty: 1-year outcomes of a prospective controlled trial of patients with primary osteoporosis Osteoporos Int 16 2005 2005 2012
    • (2005) Osteoporos Int , vol.16 , pp. 2005-2012
    • Grafe, I.A.1    Da Fonseca, K.2    Hillmeier, J.3
  • 22
    • 62349121784 scopus 로고    scopus 로고
    • Efficacy and safety of balloon kyphoplasty compared with non-surgical care for vertebral compression fracture (FREE): A randomised controlled trial
    • D. Wardlaw, S.R. Cummings, and J. Van Meirhaeghe Efficacy and safety of balloon kyphoplasty compared with non-surgical care for vertebral compression fracture (FREE): a randomised controlled trial Lancet 373 2009 1016 1024
    • (2009) Lancet , vol.373 , pp. 1016-1024
    • Wardlaw, D.1    Cummings, S.R.2    Van Meirhaeghe, J.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.