메뉴 건너뛰기




Volumn 182, Issue 1-2, 2015, Pages 443-447

Fluorescence aggregation assay for the protein biomarker mucin 1 using carbon dot-labeled antibodies and aptamers

Author keywords

Antibody; Aptamer; Carbon dots; Fluorescence assay; Mucin 1 protein

Indexed keywords


EID: 84927130804     PISSN: 00263672     EISSN: 14365073     Source Type: Journal    
DOI: 10.1007/s00604-014-1386-3     Document Type: Article
Times cited : (53)

References (26)
  • 1
    • 84890468702 scopus 로고    scopus 로고
    • Paper-based microfluidic device with upconversion fluorescence assay
    • COI: 1:CAS:528:DC%2BC3sXhvV2ku7vJ
    • He M, Liu Z (2013) Paper-based microfluidic device with upconversion fluorescence assay. Anal Chem 85(24):11691–11694. doi:10.1021/ac403693g
    • (2013) Anal Chem , vol.85 , Issue.24 , pp. 11691-11694
    • He, M.1    Liu, Z.2
  • 2
    • 84888025210 scopus 로고    scopus 로고
    • Target-mediated consecutive endonuclease reactions for specific and sensitive homogeneous fluorescence assay of O-6-methylguanine-DNA methyltransferase
    • Dinh-Vu L, Zhou D-M, Tang L-J, Jiang J-H, Yu R-Q, Wang Y-Z (2013) Target-mediated consecutive endonuclease reactions for specific and sensitive homogeneous fluorescence assay of O-6-methylguanine-DNA methyltransferase. Anal Chim Acta 804:252–257. doi:10.1016/j.aca.2013.10.036
    • (2013) Anal Chim Acta , vol.804 , pp. 252-257
    • Dinh-Vu, L.1    Zhou, D.-M.2    Tang, L.-J.3    Jiang, J.-H.4    Yu, R.-Q.5    Wang, Y.-Z.6
  • 3
    • 84881332584 scopus 로고    scopus 로고
    • Sensitive detection of protein kinase A activity in cell lysates by peptide microarray-based assay
    • COI: 1:CAS:528:DC%2BC3sXhtFSntr7K
    • Li T, Liu X, Liu D, Wang Z (2013) Sensitive detection of protein kinase A activity in cell lysates by peptide microarray-based assay. Anal Chem 85(15):7033–7037. doi:10.1021/ac4010502
    • (2013) Anal Chem , vol.85 , Issue.15 , pp. 7033-7037
    • Li, T.1    Liu, X.2    Liu, D.3    Wang, Z.4
  • 4
    • 79953234821 scopus 로고    scopus 로고
    • Copper-mediated amplification allows readout of immunoassays by the naked eye
    • COI: 1:CAS:528:DC%2BC3MXktFWmt7Y%3D
    • Qu W, Liu Y, Liu D, Wang Z, Jiang X (2011) Copper-mediated amplification allows readout of immunoassays by the naked eye. Angew Chem Int Ed 50(15):3442–3445. doi:10.1002/anie.201006025
    • (2011) Angew Chem Int Ed , vol.50 , Issue.15 , pp. 3442-3445
    • Qu, W.1    Liu, Y.2    Liu, D.3    Wang, Z.4    Jiang, X.5
  • 5
    • 78449291887 scopus 로고    scopus 로고
    • Highly sensitive electrogenerated chemiluminescence biosensor in profiling protein kinase activity and inhibition using gold nanoparticle as signal transduction probes
    • COI: 1:CAS:528:DC%2BC3cXhtleitLjO
    • Xu S, Liu Y, Wang T, Li J (2010) Highly sensitive electrogenerated chemiluminescence biosensor in profiling protein kinase activity and inhibition using gold nanoparticle as signal transduction probes. Anal Chem 82(22):9566–9572. doi:10.1021/ac102296g
    • (2010) Anal Chem , vol.82 , Issue.22 , pp. 9566-9572
    • Xu, S.1    Liu, Y.2    Wang, T.3    Li, J.4
  • 6
    • 79956342101 scopus 로고    scopus 로고
    • Sensitive electrochemical immunosensor for the detection of cancer biomarker using quantum dot functionalized graphene sheets as labels
    • COI: 1:CAS:528:DC%2BC3MXmtlCqsb0%3D
    • Yang M, Javadi A, Gong S (2011) Sensitive electrochemical immunosensor for the detection of cancer biomarker using quantum dot functionalized graphene sheets as labels. Sensors Actuators B Chem 155(1):357–360. doi:10.1016/j.snb.2010.11.055
    • (2011) Sensors Actuators B Chem , vol.155 , Issue.1 , pp. 357-360
    • Yang, M.1    Javadi, A.2    Gong, S.3
  • 7
    • 84899065285 scopus 로고    scopus 로고
    • Carcino-embryonic antigen detection based on fluorescence resonance energy transfer between quantum dots and graphene oxide
    • COI: 1:CAS:528:DC%2BC2cXotlylu7o%3D
    • Zhou Z-M, Zhou J, Chen J, Yu R-N, Zhang M-Z, Song J-T, Zhao Y-D (2014) Carcino-embryonic antigen detection based on fluorescence resonance energy transfer between quantum dots and graphene oxide. Biosensor Bioelectron 59:397–403. doi:10.1016/j.bios.2014.04.002
    • (2014) Biosensor Bioelectron , vol.59 , pp. 397-403
    • Zhou, Z.-M.1    Zhou, J.2    Chen, J.3    Yu, R.-N.4    Zhang, M.-Z.5    Song, J.-T.6    Zhao, Y.-D.7
  • 8
    • 84875707702 scopus 로고    scopus 로고
    • Highly photoluminescent carbon dots for multicolor patterning, sensors, and bioimaging
    • COI: 1:CAS:528:DC%2BC3sXjtlarur0%3D
    • Zhu S, Meng Q, Wang L, Zhang J, Song Y, Jin H, Zhang K, Sun H, Wang H, Yang B (2013) Highly photoluminescent carbon dots for multicolor patterning, sensors, and bioimaging. Angew Chem Int Ed 52:3953–3957. doi:10.1002/anie.201300519
    • (2013) Angew Chem Int Ed , vol.52 , pp. 3953-3957
    • Zhu, S.1    Meng, Q.2    Wang, L.3    Zhang, J.4    Song, Y.5    Jin, H.6    Zhang, K.7    Sun, H.8    Wang, H.9    Yang, B.10
  • 10
    • 84902492810 scopus 로고    scopus 로고
    • Na(+)-functionalized carbon quantum dots: a new draw solute in forward osmosis for seawater desalination
    • COI: 1:CAS:528:DC%2BC2cXhtVagtLrO
    • Guo CX, Zhao D, Zhao Q, Wang P, Lu X (2014) Na(+)-functionalized carbon quantum dots: a new draw solute in forward osmosis for seawater desalination. Chem Commun 50(55):7318–7321. doi:10.1039/c4cc01603c
    • (2014) Chem Commun , vol.50 , Issue.55 , pp. 7318-7321
    • Guo, C.X.1    Zhao, D.2    Zhao, Q.3    Wang, P.4    Lu, X.5
  • 12
    • 84901745926 scopus 로고    scopus 로고
    • Synthesis-modification integration: one-step fabrication of boronic acid functionalized carbon dots for fluorescent blood sugar sensing
    • COI: 1:CAS:528:DC%2BC2cXlsFyksro%3D
    • Shen P, Xia Y (2014) Synthesis-modification integration: one-step fabrication of boronic acid functionalized carbon dots for fluorescent blood sugar sensing. Anal Chem 86(11):5323–5329. doi:10.1021/ac5001338
    • (2014) Anal Chem , vol.86 , Issue.11 , pp. 5323-5329
    • Shen, P.1    Xia, Y.2
  • 13
    • 84896538516 scopus 로고    scopus 로고
    • A novel immunosensor for squamous cell carcinoma antigen determination based on CdTe@Carbon dots nanocomposite electrochemiluminescence resonance energy transfer
    • COI: 1:CAS:528:DC%2BC2cXms1Cmsbg%3D
    • Li S, Luo J, Yang X, Wan Y, Liu C (2014) A novel immunosensor for squamous cell carcinoma antigen determination based on CdTe@Carbon dots nanocomposite electrochemiluminescence resonance energy transfer. Sensors Actuators B Chem 197:43–49. doi:10.1016/j.snb.2014.02.066
    • (2014) Sensors Actuators B Chem , vol.197 , pp. 43-49
    • Li, S.1    Luo, J.2    Yang, X.3    Wan, Y.4    Liu, C.5
  • 14
    • 84899996937 scopus 로고    scopus 로고
    • Novel and green synthesis of high-fluorescent carbon dots originated from honey for sensing and imaging
    • COI: 1:CAS:528:DC%2BC2cXovVKhsLs%3D
    • Yang X, Zhuo Y, Zhu S, Luo Y, Feng Y, Dou Y (2014) Novel and green synthesis of high-fluorescent carbon dots originated from honey for sensing and imaging. Biosens Bioelectron 60:292–298. doi:10.1016/j.bios.2014.04.046
    • (2014) Biosens Bioelectron , vol.60 , pp. 292-298
    • Yang, X.1    Zhuo, Y.2    Zhu, S.3    Luo, Y.4    Feng, Y.5    Dou, Y.6
  • 15
    • 84902780939 scopus 로고    scopus 로고
    • Dual-peak electrogenerated chemiluminescence of carbon dots for iron ions detection
    • COI: 1:CAS:528:DC%2BC2cXos1Wmtrc%3D
    • Zhang P, Xue Z, Luo D, Yu W, Guo Z, Wang T (2014) Dual-peak electrogenerated chemiluminescence of carbon dots for iron ions detection. Anal Chem 86(12):5620–5623. doi:10.1021/ac5011734
    • (2014) Anal Chem , vol.86 , Issue.12 , pp. 5620-5623
    • Zhang, P.1    Xue, Z.2    Luo, D.3    Yu, W.4    Guo, Z.5    Wang, T.6
  • 16
    • 84885002104 scopus 로고    scopus 로고
    • Using graphene quantum dots as photoluminescent probes for protein kinase sensing
    • COI: 1:CAS:528:DC%2BC3sXhsVSitL%2FK
    • Wang Y, Zhang L, Liang R-P, Bai J-M, Qiu J-D (2013) Using graphene quantum dots as photoluminescent probes for protein kinase sensing. Anal Chem 85(19):9148–9155. doi:10.1021/ac401807b
    • (2013) Anal Chem , vol.85 , Issue.19 , pp. 9148-9155
    • Wang, Y.1    Zhang, L.2    Liang, R.-P.3    Bai, J.-M.4    Qiu, J.-D.5
  • 17
    • 78650777245 scopus 로고    scopus 로고
    • Label-free fluorescent detection of protein kinase activity based on the aggregation behavior of unmodified quantum dots
    • COI: 1:CAS:528:DC%2BC3cXhsFSktbjO
    • Xu X, Liu X, Nie Z, Pan Y, Guo M, Yao S (2011) Label-free fluorescent detection of protein kinase activity based on the aggregation behavior of unmodified quantum dots. Anal Chem 83:52–59. doi:10.1021/ac102786c
    • (2011) Anal Chem , vol.83 , pp. 52-59
    • Xu, X.1    Liu, X.2    Nie, Z.3    Pan, Y.4    Guo, M.5    Yao, S.6
  • 18
    • 70450247207 scopus 로고    scopus 로고
    • Mucins in cancer: function, prognosis and therapy
    • COI: 1:CAS:528:DC%2BD1MXhsVGlur7F
    • Kufe DW (2009) Mucins in cancer: function, prognosis and therapy. Nat Rev Cancer 9(12):874–885. doi:10.1038/nrc2761
    • (2009) Nat Rev Cancer , vol.9 , Issue.12 , pp. 874-885
    • Kufe, D.W.1
  • 20
    • 72949092920 scopus 로고    scopus 로고
    • Simple aqueous solution route to luminescent carbogenic dots from carbohydrates
    • COI: 1:CAS:528:DC%2BD1MXhtlKrsbjN
    • Peng H, Travas-Sejdic J (2009) Simple aqueous solution route to luminescent carbogenic dots from carbohydrates. Chem Mater 21(23):5563–5565. doi:10.1021/cm901593y
    • (2009) Chem Mater , vol.21 , Issue.23 , pp. 5563-5565
    • Peng, H.1    Travas-Sejdic, J.2
  • 21
    • 84884812141 scopus 로고    scopus 로고
    • Highly photoluminescent amino-functionalized graphene quantum dots used for sensing copper ions
    • COI: 1:CAS:528:DC%2BC3sXht1Crt7zP
    • Sun H, Gao N, Wu L, Ren J, Wei W, Qu X (2013) Highly photoluminescent amino-functionalized graphene quantum dots used for sensing copper ions. Chem Eur J 19(40):13362–13368. doi:10.1002/chem.201302268
    • (2013) Chem Eur J , vol.19 , Issue.40 , pp. 13362-13368
    • Sun, H.1    Gao, N.2    Wu, L.3    Ren, J.4    Wei, W.5    Qu, X.6
  • 22
    • 84875228323 scopus 로고    scopus 로고
    • Carbon dots-based fluorescent probes for sensitive and selective detection of iodide
    • COI: 1:CAS:528:DC%2BC3sXktleku74%3D
    • Du F, Zeng F, Ming Y, Wu S (2013) Carbon dots-based fluorescent probes for sensitive and selective detection of iodide. Microchim Acta 180:453–460. doi:10.1007/s00604-013-0954-2
    • (2013) Microchim Acta , vol.180 , pp. 453-460
    • Du, F.1    Zeng, F.2    Ming, Y.3    Wu, S.4
  • 23
    • 84859340334 scopus 로고    scopus 로고
    • Electrochemiluminescent detection of mucin 1 protein and MCF-7 cancer cells based on the resonance energy transfer
    • COI: 1:CAS:528:DC%2BC38XkvFSjtrw%3D
    • Wei W, Li DF, Pan XH, Liu SQ (2012) Electrochemiluminescent detection of mucin 1 protein and MCF-7 cancer cells based on the resonance energy transfer. Analyst 137:2101–2106. doi:10.1039/c2an35059a
    • (2012) Analyst , vol.137 , pp. 2101-2106
    • Wei, W.1    Li, D.F.2    Pan, X.H.3    Liu, S.Q.4
  • 24
    • 84887193021 scopus 로고    scopus 로고
    • Novel electrochemical aptamer biosensor based on an enzyme–gold nanoparticle dual label for the ultrasensitive detection of epithelial tumour marker MUC1
    • COI: 1:CAS:528:DC%2BC3sXhvFWitr3E
    • Hu R, Wen W, Wang Q, Xiong H, Zhang X, Gu H, Wang S (2014) Novel electrochemical aptamer biosensor based on an enzyme–gold nanoparticle dual label for the ultrasensitive detection of epithelial tumour marker MUC1. Biosensor Bioelectron 53:384–389. doi:10.1016/j.bios.2013.10.015
    • (2014) Biosensor Bioelectron , vol.53 , pp. 384-389
    • Hu, R.1    Wen, W.2    Wang, Q.3    Xiong, H.4    Zhang, X.5    Gu, H.6    Wang, S.7
  • 25
    • 84857803799 scopus 로고    scopus 로고
    • A graphene oxide-based fluorescent aptasensor for the turn-on detection of epithelial tumor marker mucin 1
    • COI: 1:CAS:528:DC%2BC38XjtFyrurc%3D
    • He Y, Lin Y, Tang H, Pang D (2012) A graphene oxide-based fluorescent aptasensor for the turn-on detection of epithelial tumor marker mucin 1. Nanoscale 4:2054–2059. doi:10.1039/C2NR12061E
    • (2012) Nanoscale , vol.4 , pp. 2054-2059
    • He, Y.1    Lin, Y.2    Tang, H.3    Pang, D.4
  • 26
    • 68049104230 scopus 로고    scopus 로고
    • Aptamer-based detection of epithelial tumor marker ucin 1 with quantum dot-based fluorescence readout
    • Cheng AKH, Su H, Wang YA, Yu H-Z (2009) Aptamer-based detection of epithelial tumor marker ucin 1 with quantum dot-based fluorescence readout. Anal Chem 81:8130–8139. doi:10.1021/ac901223q
    • (2009) Anal Chem , vol.81 , pp. 8130-8139
    • Cheng, A.K.H.1    Su, H.2    Wang, Y.A.3    Yu, H.-Z.4


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.