메뉴 건너뛰기




Volumn 64, Issue 6, 2014, Pages 423-429

Characterization of in-stent neointimal tissue components following drug-eluting stent implantation according to the phase of restenosis using a 40-MHz intravascular ultrasound imaging system

Author keywords

Angina pectoris; Coronary artery disease; Drug eluting stent; In stent restenosis; Neoatherosclerosis

Indexed keywords

ADULT; AGED; ANGIOCARDIOGRAPHY; ARTICLE; CARDIAC PATIENT; CLINICAL ARTICLE; COMPARATIVE STUDY; CONTROLLED STUDY; DRUG ELUTING STENT; FEMALE; FOLLOW UP; HUMAN; IN-STENT RESTENOSIS; INTRAVASCULAR ULTRASOUND; INTRAVASCULAR ULTRASOUND SYSTEM; MALE; NEOINTIMA; PERCUTANEOUS CORONARY INTERVENTION; RADIOFREQUENCY; STABLE ANGINA PECTORIS; TISSUE CHARACTERIZATION; CORONARY BLOOD VESSEL; DEVICES; ECHOGRAPHY; ENDOSCOPIC ECHOGRAPHY; POSTOPERATIVE PERIOD; RADIOGRAPHY; RESTENOSIS;

EID: 84926419452     PISSN: 09145087     EISSN: 18764738     Source Type: Journal    
DOI: 10.1016/j.jjcc.2014.03.001     Document Type: Article
Times cited : (12)

References (24)
  • 1
    • 0037030658 scopus 로고    scopus 로고
    • Randomized Study with the Sirolimus-Coated Bx Velocity Balloon-Expandable Stent in the Treatment of Patients with de Novo Native Coronary Artery Lesions. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization
    • RAVEL Study Group
    • Morice M.C., Serruys P.W., Sousa J.E., Fajadet J., Ban Hayashi E., Perin M., Colombo A., Schuler G., Barragan P., Guagliumi G., Molnàr F., Falotico R. Randomized Study with the Sirolimus-Coated Bx Velocity Balloon-Expandable Stent in the Treatment of Patients with de Novo Native Coronary Artery Lesions. A randomized comparison of a sirolimus-eluting stent with a standard stent for coronary revascularization. N Engl J Med 2002, 346:1773-1780. RAVEL Study Group.
    • (2002) N Engl J Med , vol.346 , pp. 1773-1780
    • Morice, M.C.1    Serruys, P.W.2    Sousa, J.E.3    Fajadet, J.4    Ban Hayashi, E.5    Perin, M.6    Colombo, A.7    Schuler, G.8    Barragan, P.9    Guagliumi, G.10    Molnàr, F.11    Falotico, R.12
  • 3
    • 48749108425 scopus 로고    scopus 로고
    • Clinical presentation of patients with in-stent restenosis in the drug-eluting stent era
    • Lee M.S., Pessegueiro A., Zimmer R., Jurewitz D., Tobis J. Clinical presentation of patients with in-stent restenosis in the drug-eluting stent era. J Invasive Cardiol 2008, 20:401-403.
    • (2008) J Invasive Cardiol , vol.20 , pp. 401-403
    • Lee, M.S.1    Pessegueiro, A.2    Zimmer, R.3    Jurewitz, D.4    Tobis, J.5
  • 5
    • 24644465504 scopus 로고    scopus 로고
    • Late restenosis in patients receiving a polymer-coated sirolimus-eluting stent
    • Wessely R., Kastrati A., Schömig A. Late restenosis in patients receiving a polymer-coated sirolimus-eluting stent. Ann Intern Med 2005, 143:392-394.
    • (2005) Ann Intern Med , vol.143 , pp. 392-394
    • Wessely, R.1    Kastrati, A.2    Schömig, A.3
  • 6
  • 7
    • 73049110833 scopus 로고    scopus 로고
    • Characterisation of atherosclerotic plaque by spectral similarity of radiofrequency intravascular ultrasound signals
    • Sathyanarayana S., Carlier S., Li W., Thomas L. Characterisation of atherosclerotic plaque by spectral similarity of radiofrequency intravascular ultrasound signals. EuroIntervention 2009, 5:133-139.
    • (2009) EuroIntervention , vol.5 , pp. 133-139
    • Sathyanarayana, S.1    Carlier, S.2    Li, W.3    Thomas, L.4
  • 8
    • 65549111017 scopus 로고    scopus 로고
    • GFR Collaborators developing the Japanese equation for estimated GFR. Revised equations for estimated GFR from serum creatinine in Japan
    • Matsuo S., Imai E., Horio M., Yasuda Y., Tomita K., Nitta K., Yamagata K., Tomino Y., Yokoyama H., Hishida A. GFR Collaborators developing the Japanese equation for estimated GFR. Revised equations for estimated GFR from serum creatinine in Japan. Am J Kidney Dis 2009, 53:982-992.
    • (2009) Am J Kidney Dis , vol.53 , pp. 982-992
    • Matsuo, S.1    Imai, E.2    Horio, M.3    Yasuda, Y.4    Tomita, K.5    Nitta, K.6    Yamagata, K.7    Tomino, Y.8    Yokoyama, H.9    Hishida, A.10
  • 9
    • 0021916187 scopus 로고
    • The thrombolysis in myocardial infarction (TIMI) trial. Phase 1 findings. TIMI study group
    • The thrombolysis in myocardial infarction (TIMI) trial. Phase 1 findings. TIMI study group. N Engl J Med 1985, 312:932-936.
    • (1985) N Engl J Med , vol.312 , pp. 932-936
  • 11
    • 0035312809 scopus 로고    scopus 로고
    • American College of Cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents
    • Mintz G., Nissen S., Anderson W., Bailey S., Erbel R., Fitzgerald P., Pinto F., Rosenfield K., Siegel R., Tuzcu E., Yock P. American College of Cardiology clinical expert consensus document on standards for acquisition, measurement and reporting of intravascular ultrasound studies (IVUS). A report of the American College of Cardiology Task Force on Clinical Expert Consensus Documents. J Am Coll Cardiol 2001, 37:1478-1492.
    • (2001) J Am Coll Cardiol , vol.37 , pp. 1478-1492
    • Mintz, G.1    Nissen, S.2    Anderson, W.3    Bailey, S.4    Erbel, R.5    Fitzgerald, P.6    Pinto, F.7    Rosenfield, K.8    Siegel, R.9    Tuzcu, E.10    Yock, P.11
  • 12
    • 0037303940 scopus 로고    scopus 로고
    • Drug eluting stents: are human and animal studies comparable?
    • Virmani R., Kolodgie F.D., Farb A., Lafont A. Drug eluting stents: are human and animal studies comparable?. Heart 2003, 89:133-138.
    • (2003) Heart , vol.89 , pp. 133-138
    • Virmani, R.1    Kolodgie, F.D.2    Farb, A.3    Lafont, A.4
  • 13
    • 77953484204 scopus 로고    scopus 로고
    • Intriguing peri-strut low-intensity area detected by optical coherence tomography after coronary stent deployment
    • Teramoto T., Ikeno F., Otake H., Lyons J.K., van Beusekom H.M., Fearon W.F., Yeung A.C. Intriguing peri-strut low-intensity area detected by optical coherence tomography after coronary stent deployment. Circ J 2010, 74:1257-1259.
    • (2010) Circ J , vol.74 , pp. 1257-1259
    • Teramoto, T.1    Ikeno, F.2    Otake, H.3    Lyons, J.K.4    van Beusekom, H.M.5    Fearon, W.F.6    Yeung, A.C.7
  • 18
    • 65549161443 scopus 로고    scopus 로고
    • One step forward and two steps back with drug-eluting-stents: from preventing restenosis to causing late thrombosis and nouveau atherosclerosis
    • Nakazawa G., Vorpahl M., Finn A.V., Narula J., Virmani R. One step forward and two steps back with drug-eluting-stents: from preventing restenosis to causing late thrombosis and nouveau atherosclerosis. JACC Cardiovasc Imaging 2009, 2:625-628.
    • (2009) JACC Cardiovasc Imaging , vol.2 , pp. 625-628
    • Nakazawa, G.1    Vorpahl, M.2    Finn, A.V.3    Narula, J.4    Virmani, R.5
  • 20
    • 79851479830 scopus 로고    scopus 로고
    • Qualitative assessment of neointimal tissue after drug-eluting stent implantation: comparison between follow-up optical coherence tomography and intravascular ultrasound
    • Kwon S.W., Kim B.K., Kim T.H., Kim J.S., Ko Y.G., Choi D., Jang Y., Hong M.K. Qualitative assessment of neointimal tissue after drug-eluting stent implantation: comparison between follow-up optical coherence tomography and intravascular ultrasound. Am Heart J 2011, 161:367-372.
    • (2011) Am Heart J , vol.161 , pp. 367-372
    • Kwon, S.W.1    Kim, B.K.2    Kim, T.H.3    Kim, J.S.4    Ko, Y.G.5    Choi, D.6    Jang, Y.7    Hong, M.K.8
  • 21
    • 80355145182 scopus 로고    scopus 로고
    • Relationship between tissue characterisations with 40MHz intravascular ultrasound imaging and slow flow during coronary intervention
    • Utsunomiya M., Hara H., Sugi K., Nakamura M. Relationship between tissue characterisations with 40MHz intravascular ultrasound imaging and slow flow during coronary intervention. EuroIntervention 2011, 7:340-346.
    • (2011) EuroIntervention , vol.7 , pp. 340-346
    • Utsunomiya, M.1    Hara, H.2    Sugi, K.3    Nakamura, M.4
  • 22
    • 84874117511 scopus 로고    scopus 로고
    • Visualization of coronary plaque in arterial remodeling using a new 40-MHz intravascular ultrasound imaging system
    • Araki T., Nakamura M., Utsunomiya M., Sugi K. Visualization of coronary plaque in arterial remodeling using a new 40-MHz intravascular ultrasound imaging system. Catheter Cardiovasc Interv 2013, 81:471-480.
    • (2013) Catheter Cardiovasc Interv , vol.81 , pp. 471-480
    • Araki, T.1    Nakamura, M.2    Utsunomiya, M.3    Sugi, K.4
  • 23
    • 77951717666 scopus 로고    scopus 로고
    • Histology of highly echolucent regions in optical coherence tomography images from two patients with sirolimus-eluting stent restenosis
    • Nagai H., Ishibashi-Ueda H., Fujii K. Histology of highly echolucent regions in optical coherence tomography images from two patients with sirolimus-eluting stent restenosis. Catheter Cardiovasc Interv 2010, 75:961-963.
    • (2010) Catheter Cardiovasc Interv , vol.75 , pp. 961-963
    • Nagai, H.1    Ishibashi-Ueda, H.2    Fujii, K.3


* 이 정보는 Elsevier사의 SCOPUS DB에서 KISTI가 분석하여 추출한 것입니다.